Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 12(3)2022 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-35323420

RESUMO

Continuous blood pressure (BP) measurement is crucial for long-term cardiovascular monitoring, especially for prompt hypertension detection. However, most of the continuous BP measurements rely on the pulse transit time (PTT) from multiple-channel physiological acquisition systems that impede wearable applications. Recently, wearable and smart health electronics have become significant for next-generation personalized healthcare progress. This study proposes an intelligent single-channel bio-impedance system for personalized BP monitoring. Compared to the PTT-based methods, the proposed sensing configuration greatly reduces the hardware complexity, which is beneficial for wearable applications. Most of all, the proposed system can extract the significant BP features hidden from the measured bio-impedance signals by an ultra-lightweight AI algorithm, implemented to further establish a tailored BP model for personalized healthcare. In the human trial, the proposed system demonstrates the BP accuracy in terms of the mean error (ME) and the mean absolute error (MAE) within 1.7 ± 3.4 mmHg and 2.7 ± 2.6 mmHg, respectively, which agrees with the criteria of the Association for the Advancement of Medical Instrumentation (AAMI). In conclusion, this work presents a proof-of-concept for an AI-based single-channel bio-impedance BP system. The new wearable smart system is expected to accelerate the artificial intelligence of things (AIoT) technology for personalized BP healthcare in the future.


Assuntos
Inteligência Artificial , Determinação da Pressão Arterial , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Impedância Elétrica , Humanos , Fotopletismografia , Análise de Onda de Pulso
2.
Sensors (Basel) ; 21(5)2021 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-33668822

RESUMO

Continuous hemodynamic monitoring is important for long-term cardiovascular healthcare, especially in hypertension. The impedance plethysmography (IPG) based carotid pulse sensing is a non-invasive diagnosis technique for measuring pulse signals and further evaluating the arterial conditions of the patient such as continuous blood pressure (BP) monitoring. To reach the high-resolution IPG-based carotid pulse detection for cardiovascular applications, this study provides an optimized measurement parameter in response to obvious pulsation from the carotid artery. The influence of the frequency of excitation current, electrode cross-sectional area, electrode arrangements, and physiological site of carotid arteries on IPG measurement resolution was thoroughly investigated for optimized parameters. In this study, the IPG system was implemented and installed on the subject's neck above the carotid artery to evaluate the measurement parameters. The measurement results within 6 subjects obtained the arterial impedance variation of 2137 mΩ using the optimized measurement conditions, including excitation frequency of 50 kHz, a smaller area of 2 cm2, electrode spacing of 4 cm and 1.7 cm for excitation and sensing functions, and location on the left side of the neck. The significance of this study demonstrates an optimized measurement methodology of IPG-based carotid pulse sensing that greatly improves the measurement quality in cardiovascular monitoring.


Assuntos
Determinação da Pressão Arterial , Análise de Onda de Pulso , Pressão Sanguínea , Impedância Elétrica , Humanos , Pletismografia de Impedância , Pulso Arterial
3.
Biosens Bioelectron ; 179: 113060, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33571936

RESUMO

BACKGROUND: Electrophysiological sensing of cardiomyocytes (CMs) in optogenetic preparations applies various techniques, such as patch-clamp, microelectrode array, and optical mapping. However, challenges remain in decreasing the cost, system dimensions, and operating skills required for these technologies. OBJECTIVE: This study developed a low-cost, portable impedance plethysmography (IPG)-based electrophysiological measurement of cultured CMs for optogenetic applications. METHODS: To validate the efficacy of the proposed sensor, optogenetic stimulation with different pacing cycle lengths (PCL) was performed to evaluate whether the channelrhodopsin-2 (ChR2)-expressing CM beating rhythm measured by the IPG sensor was consistent with biological responses. RESULTS: The experimental results show that the CM field potential was synchronized with external optical pacing with PCLs ranging from 250 ms to 1000 ms. Moreover, irregular fibrillating waveforms induced by CM arrhythmia were detected after overdrive optical pacing. Through the combined evidence of the theoretical model and experimental results, this study confirmed the feasibility of long-term electrophysiological sensing for optogenetic CMs. CONCLUSION: This study proposes an IPG-based sensor that is low-cost, portable, and requires low-operating skills to perform real-time CM field potential measurement in response to optogenetic stimulation. SIGNIFICANCE: This study demonstrates a new methodology for convenient electrophysiological sensing of CMs in optogenetic applications.


Assuntos
Técnicas Biossensoriais , Optogenética , Potenciais de Ação , Arritmias Cardíacas , Channelrhodopsins/genética , Humanos , Miócitos Cardíacos
4.
BMC Bioinformatics ; 17(Suppl 19): 514, 2016 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-28155663

RESUMO

BACKGROUND: Bacterial tyrosine-kinases (BY-kinases), which play an important role in numerous cellular processes, are characterized as a separate class of enzymes and share no structural similarity with their eukaryotic counterparts. However, in silico methods for predicting BY-kinases have not been developed yet. Since these enzymes are involved in key regulatory processes, and are promising targets for anti-bacterial drug design, it is desirable to develop a simple and easily interpretable predictor to gain new insights into bacterial tyrosine phosphorylation. This study proposes a novel SCMBYK method for predicting and characterizing BY-kinases. RESULTS: A dataset consisting of 797 BY-kinases and 783 non-BY-kinases was established to design the SCMBYK predictor, which achieved training and test accuracies of 97.55 and 96.73%, respectively. Furthermore, the leave-one-phylum-out method was used to predict specific bacterial phyla hosts of target sequences, gaining 97.39% average test accuracy. After analyzing SCMBYK-derived propensity scores, four characteristics of BY-kinases were determined: 1) BY-kinases tend to be composed of α-helices; 2) the amino-acid content of extracellular regions of BY-kinases is expected to be dominated by residues such as Val, Ile, Phe and Tyr; 3) BY-kinases structurally resemble nuclear proteins; 4) different domains play different roles in triggering BY-kinase activity. CONCLUSIONS: The SCMBYK predictor is an effective method for identification of possible BY-kinases. Furthermore, it can be used as a part of a novel drug repurposing method, which recognizes putative BY-kinases and matches them to approved drugs. Among other results, our analysis revealed that azathioprine could suppress the virulence of M. tuberculosis, and thus be considered as a potential antibiotic for tuberculosis treatment.


Assuntos
Bactérias/enzimologia , Proteínas de Bactérias/química , Dipeptídeos/química , Proteínas Tirosina Quinases/química , Software , Tirosina/química , Bases de Dados de Proteínas , Pontuação de Propensão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA