Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
1.
J Electrocardiol ; 85: 37-38, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38830293

RESUMO

We present the case of a 60-year-old male patient who was admitted to our hospital after experiencing a syncopal episode. First ECGs showed sinus rhythm with polymorphic premature ventricular complexes and later ventricular tachycardia with a left bundle branch block morphology were recorded. Imaging with TEE and MRI revealed a space-occupying lesion in the left ventricle, which was ultimately identified as a rare cardiac metastasis of renal cell carcinoma. Treatment was initiated with monoclonal antibodies resulting in lesion regression. This case highlights the importance of comprehensive diagnostic in patients with history of malignancy.

2.
Herzschrittmacherther Elektrophysiol ; 35(2): 155-164, 2024 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-38748284

RESUMO

The implantation of electrodes for cardiac implantable electronic devices (CIED) requires profound technical understanding and precise execution. The positioning of electrodes in the right ventricle and atrium has significant implications for patient safety and the effectiveness of CIED therapy. Particular focus is given to the distinction between apical and septal stimulation in ventricular positioning. Based on current data, this article provides a practice-oriented guide that leads implanters through the individual steps of electrode positioning. The implantation of electrodes for physiological stimulation (cardiac resynchronization therapy, CRT, and conduction system pacing, CSP) is not addressed in this article.


Assuntos
Desfibriladores Implantáveis , Eletrodos Implantados , Marca-Passo Artificial , Humanos , Implantação de Prótese/métodos , Cirurgia Assistida por Computador/instrumentação , Medicina Baseada em Evidências
3.
Artigo em Inglês | MEDLINE | ID: mdl-38573537

RESUMO

BACKGROUND: Vascular complications are a common occurrence during atrial fibrillation ablation. Observational studies indicate that the utilization of ultrasound (US)-guided puncture may decrease the incidence of vascular complications; however, its routine use is not established in many centres. METHODS: Patients undergoing catheter ablation for atrial fibrillation were included sequentially. All patients receiving US-guided punctures were prospectively enrolled (US group), while patients who underwent the procedure with standard puncture technique served as control group (No-US group). Periprocedural vascular complications requiring intervention within 30 days of the procedure were defined as the primary endpoint. RESULTS: A total of 599 patients (average age: 69 ± 11 years, 62.9% male) were analysed. The incidence of vascular complications was lower with the US-guided puncture than with the anatomic landmark-guided puncture (14/299 [4.7%] vs. 27/300 [9%], p = 0.036). The US-guided vascular access significantly reduced the rate of false aneurysms (3/299 [1%] vs. 12/300 [4%], p = 0.019). In addition, the occurrence of arteriovenous fistula (2/299 [0.7%] vs. 4/300 [1.3%], p = 0.686) and haematoma requiring treatment (9/299 [3%] vs. 11/300 [3.7%], p = 0.655) were also lower in the US group. US-guided puncture did not prolong the procedure time (mean procedure time: 57.48 ± 24.47 min vs. 56.09 ± 23.36 min, p = 0.478). Multivariate regression analysis identified female gender (OR 2.079, CI 95% 1.096-3.945, p = 0.025) and conventional vascular access (OR 2.079, CI 95% 1.025-3.908, p = 0.042) as predictors of vascular complications. CONCLUSIONS: The implementation of US-guided vascular access for left atrial catheter ablation resulted in a significant decrease of the overall vascular complication rate.

5.
JACC Clin Electrophysiol ; 10(4): 698-708, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38340118

RESUMO

BACKGROUND: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology with high procedural safety and efficiency for pulmonary vein isolation (PVI). Premarket data showed high PVI durability during mandatory remapping studies. Data on lesion durability in real-world patients with clinically indicated redo procedures are scarce. OBJECTIVES: This study sought to report PVI durability rates in patients undergoing a clinically indicated redo procedure after an index PVI using PFA. METHODS: Patients from 7 European centers undergoing an index PVI using PFA were included the EU-PORIA (European Real-world Outcomes With Pulsed Field Ablation in Patients With Symptomatic Atrial Fibrillation) registry. In patients with subsequent left atrial redo procedures due to arrhythmia recurrence, 3-dimensional electroanatomical maps were acquired. PVI durability was assessed on a per-vein and per-patient level, and sites of reconnections and predictors of lesion durability were identified. RESULTS: Of 1,184 patients (62% paroxysmal atrial fibrillation) undergoing an index PVI using PFA, 272 (23%) had an arrhythmia recurrence. Of these, 144 (53%) underwent a left atrial redo procedure a median of 7 (Q1-Q3: 5-10) months after the first ablation. Three-dimensional electroanatomical maps identified 404 of 567 pulmonary veins (71%) with durable isolation. In 54 patients (38%), all pulmonary veins were durably isolated. Prior operator experience with cryoballoon ablation was associated with a higher PVI durability compared to operators with only point-by-point radiofrequency experience (76% vs 60%; P < 0.001). Neither the operators' cumulative experience in atrial fibrillation ablation (≤5 vs >5 years) nor the size of the PFA device used (31 mm vs 35 mm) had an impact on subsequent lesion durability (both P > 0.50). CONCLUSIONS: In 144 patients with arrhythmia recurrence after PFA PVI, durable isolation was observed in 71% of the pulmonary veins during the redo procedure, and 38% of all patients showed durable isolation of all veins.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Sistema de Registros , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Idoso , Europa (Continente) , Resultado do Tratamento , Recidiva , Reoperação/estatística & dados numéricos
6.
Herzschrittmacherther Elektrophysiol ; 35(1): 83-90, 2024 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-38289503

RESUMO

Cardiovascular implantable electronic devices (CIED) are an important part of modern cardiology and careful perioperative planning of these procedures is necessary. All information relevant to the indication, the procedure, and the education of the patient must be available prior to surgery. This provides the basis for appropriate device selection. Preoperative antibiotic prophylaxis and perioperative anticoagulation management are essential to prevent infection. After surgery, postoperative monitoring, telemetric control, and device-based diagnostics are required before discharge. These processes need to be adapted to the increasing trend towards outpatient care. This review summarises perioperative management based on practical considerations.


Assuntos
Cardiologia , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos
7.
J Interv Card Electrophysiol ; 67(3): 493-501, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37505337

RESUMO

BACKGROUND: Cryoballoon ablation is a well-established anatomical approach for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Although widely adopted, regional variations in standards of care have not been well characterized. METHODS: Patients with AF were enrolled in the Cryo Global Registry (NCT02752737) from May 2016 to Sept 2021 at 128 sites in 37 countries and treated with cryoballoon ablation according to local clinical practice. Baseline patient and procedural characteristics were summarized for 8 regions (Central Asia & Russia, East Asia, Europe, Middle East, North America, South Africa, South America, and Southeast Asia). Serious procedure-related adverse events (SAEs) were evaluated in a subset of patients with ≥ 7 days of follow-up. RESULTS: A total of 3,680 patients undergoing initial PVI for AF were included. Cryoballoon ablation was commonly performed in patients with paroxysmal AF. Mean age ranged from 47 ± 12 years in the Middle East to 64 ± 11 years in East Asia. Mean procedure time was ≤ 95 min in all regions. Average freeze duration ranged from 153 ± 41 s in Southeast Asia to 230 ± 29 s in Central Asia & Russia. Acute procedural success was ≥ 94.7% in all geographies. In 3,126 subjects with ≥ 7 days of follow-up, 122 procedure-related SAEs were reported in 111 patients (3.6%) and remained low in all regions. One procedure-related death was reported during data collection. CONCLUSIONS: Despite regional variations in patient selection and procedural characteristics, PVI using cryoballoon ablation was performed with high acute success and short procedural times around the world. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT02752737.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Adulto , Pessoa de Meia-Idade , Resultado do Tratamento , Seleção de Pacientes , Criocirurgia/métodos , Sistema de Registros , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Recidiva
8.
Artigo em Inglês | MEDLINE | ID: mdl-38082096

RESUMO

BACKGROUND: Limited information is available on the safety and efficacy of cryoballoon ablation (CBA) in elderly patients with atrial fibrillation (AF). Moreover, global utilization of CBA in this population (≥ 80 years old) has not been reported. This study's objectives were to determine the use, efficacy, and safety of CBA to treat octogenarians suffering from AF. METHODS: In this sub-analysis of the Cryo Global Registry, 12-month outcomes of treating AF via CBA in octogenarians were compared to patients < 80 years old. Efficacy was evaluated as time to a ≥ 30 s atrial arrhythmia (AA) recurrence. Healthcare utilization was determined via repeat ablations and hospitalizations. Improvement upon disease burden was evaluated through patient reporting of symptoms and the EQ-5D-3L quality of life (QoL) survey. RESULTS: The octogenarian cohort (n = 101) had a higher prevalence of females (51.5% vs 35.7%) and CHA2DS2-VASc scores (4.2 ± 1.3 vs 2.0 ± 1.5) compared to the control cohort (n = 1573, both p < 0.01). Even when adjusting for baseline characteristics and antiarrhythmic drug usage, freedom from AA recurrence at 12 months (80.6% vs 78.9%, HRadj:0.97 [95% CI:0.59-1.58], p = 0.90) was comparable between octogenarians and control, respectively. Similar serious adverse event rates were observed between octogenarians (5.0%) and control (3.2%, p = 0.38). The groups did not differ in healthcare utilization nor reduction of AF-related symptoms from baseline to follow-up, but both experienced an improvement in QoL at 12 months. CONCLUSIONS: Despite more age-related comorbidities, CBA is a safe and effective treatment for AF in octogenarians, with efficacy and adverse events rates akin to ablations performed in younger patients. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT02752737.

9.
J Cardiovasc Electrophysiol ; 34(12): 2425-2433, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37767744

RESUMO

INTRODUCTION: Pulsed field ablation (PFA) is a new ablation technology for atrial fibrillation (AF). Data regarding early recurrences of atrial tachyarrhythmia (ERAT) after PFA-pulmonary vein isolation (PVI) are sparse. METHODS: Consecutive patients with symptomatic AF were enrolled to undergo PFA-PVI. A dedicated catheter delivering bipolar energy (1.9-2.0 kV) was used. Late recurrence (LR) was defined as documented AF/atrial tachycardia (AT) lasting more than 30 s after a 90-day blanking period. RESULTS: Two hundred and thirty-one patients (42% female, age 69 ± 12, 55% paroxysmal AF [PAF]) were included in this analysis. Median follow-up time was 367 days (interquartile range: 253-400). Forty-six patients (21%) experienced ERAT after a median of 23 days (46% in PAF and 54% in persistent AF [persAF]). Kaplan-Meier estimated freedom of AF/AT was 74.2% at 1 year, 81.8% for PAF, and 64.8% for persAF (p = .0079). Of patients experiencing ERAT, an LR was observed in 54%. There was no significant difference of LR between those who presented with very early ERAT (0-45 days) and those with ERAT (46-90 days) (p = .57). In multivariate analysis, ERAT (hazard ratio [HR]: 3.370; 95% confidence interval [95% CI]: 1.851-6.136; p < .001) and female sex (HR: 2.048; 95% CI: 1.114-3.768; p = .021) were the only independent predictors for LR. CONCLUSIONS: ERAT could be recorded in 21% of patients after PFA-PVI and was an independent predictor for LR. We found no difference in the rate of LRs among patients experiencing ERAT before or after 45 days.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Fatores de Tempo , Recidiva , Átrios do Coração , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia
10.
JACC Clin Electrophysiol ; 9(9): 1864-1875, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37480870

RESUMO

BACKGROUND: Although the autonomic reaction such as bradycardia is observed frequently during pulsed-field ablation (PFA)-guided pulmonary vein isolation (PVI), its mechanism and effect on the adjacent intrinsic cardiac autonomic nervous system (ICANS) are unclear. OBJECTIVES: This study aimed to reveal the clinical impact of PFA on ICANS by investigating the serum S100 increase (ΔS100), a well-known denervation relevant biomarker. METHODS: Pre- and postprocedural serum S100 analyses were systematically conducted in patients undergoing PVI using either the pentaspline PFA or cryoballoon ablation (CBA) system. ΔS100 release kinetics were compared between both technologies. Cerebral magnetic resonance imaging was conducted to eliminate the effect of central nervous system release. RESULTS: A total of 97 patients (PFA: n = 54 and CBA: n = 43) were enrolled. Overall S100 increased in both groups with a lower amount in PFA (0.035 µg/L; IQR: 0.02-0.063 µg/L) compared with CBA (0.12 µg/L; IQR: 0.09-0.17 µg/L; P < 0.0001). In cerebral magnetic resonance imaging, silent emboli were detected in 10 patients (18.5%) in PFA and 7 patients (16.3%) in CBA (P = 0.773). Even after excluding patients with cerebral emboli, ΔS100 was lower in PFA. During PFA PVI, 30 patients (56%) demonstrated transient bradycardia in 70 of 210 PVs (35%). ΔS100 was similar between patients with or without transient bradycardia. CONCLUSIONS: We report a significantly lower S100 release following PFA PVI vs CBA PVI even if silent cerebral emboli were excluded. Notably, vagal response during PFA was not associated with S100 release. These observations are in line with lower nervous tissue destruction of PFA compared with CBA.


Assuntos
Embolia Intracraniana , Veias Pulmonares , Humanos , Bradicardia , Veias Pulmonares/cirurgia , Coração , Sistema Nervoso Autônomo
11.
J Interv Card Electrophysiol ; 66(3): 711-722, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36331681

RESUMO

BACKGROUND: Cryoballoon ablation (CBA) is an effective first-line treatment for symptomatic atrial fibrillation (AF), as recently demonstrated by three randomized trials. This sub-analysis of the Cryo Global Registry aims to examine current clinical practices of first-line CBA. METHODS: AF patients treated with first-line CBA were compared to CBA in antiarrhythmic drug (AAD)-refractory patients at 12 months. Efficacy was examined using time-to-first atrial arrhythmia recurrence following a 90-day blanking period. Healthcare utilization was evaluated by repeat ablations and hospitalizations. Disease burden was examined by assessing quality of life (QOL) and patients' reporting of symptoms. RESULTS: Of 1394 patients, 433 (31.1%) were treated with first-line CBA, which was more frequent in high-volume centers. Serious procedure-related adverse event rates were similar. Efficacy at 12 months was higher in the first-line group (87.8 vs. 81.6%, HRunadj 0.64 (95% CI 0.47-0.88); p < 0.01) regardless of the centers' CBA experience; when controlling for baseline characteristics, the difference was not significant (HRadj 0.87 (95% CI 0.56-1.37); p = 0.55). No difference was observed in repeat ablations and hospitalizations between cohorts. First-line patients experienced a larger mean reduction in symptoms and were prescribed AADs at a lower rate at 12-month follow-up (9.7 vs. 29.9%). QOL improved in both cohorts from baseline to 12 months with no significant difference between groups (p = 0.29). CONCLUSIONS: In this global real-world experience, first-line CBA in patients with symptomatic AF is effective, with a larger symptom reduction compared with CBA after AAD failure and without a difference in healthcare utilization at mid-term follow-up. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT02752737.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Humanos , Antiarrítmicos/uso terapêutico , Efeitos Psicossociais da Doença , Criocirurgia/efeitos adversos , Aceitação pelo Paciente de Cuidados de Saúde , Qualidade de Vida , Recidiva , Resultado do Tratamento
12.
Europace ; 25(2): 433-440, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36427201

RESUMO

AIMS: Pulsed-field ablation (PFA) can offer a novel perspective for atrial fibrillation (AF) ablation. We aimed to characterize the incidence of pulmonary vein (PV) reconnection, types of recurrent atrial tachyarrhythmia (ATa) and lesion quality after PFA-guided PV isolation (PVI). METHODS AND RESULTS: Patients undergoing second ablation for recurrent ATa following the initial PVI using the pentaspline PFA catheter were investigated. The rate of PV reconnection, the features of recurrent ATa, and the amount of isolated posterior wall (PW) surface area (ISAPW%) (ratio of the isolated- to total surface area on PW) were analyzed. RESULTS: Among 360 patients treated with PFA, 25 patients (paroxysmal AF, n = 19) with 99 PVs underwent a second procedure 6.1 ± 4.0 months after the initial procedure. The rate of PV reconnection was 9.1% (9 PVs). Patients presented with atrial tachycardia (AT) (n = 16), AF (n = 8) and typical atrial flutter (n = 1). The mechanism of all but one AT was macro-reentry. The critical isthmus was found to be linked to the initial lesion set at the left atrial (LA) PW in eight patients and linked to pre-existing substrate at the LA anterior wall in four patients. One AT had a focal origin at the septum. In three patients, AT were unmappable. Mean ISAPW% was 72.7 ± 19.0%. CONCLUSION: We revealed a remarkable low reconnection rate with a large antral lesion at the PW after pentaspline PFA catheter-guided PVI. However, macro-reentrant AT with a critical isthmus at the LAPW linked to the PVI lesion set was commonly observed.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva , Resultado do Tratamento
13.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38163951

RESUMO

AIMS: Pericardial tamponade (PT) is the most frequent severe complication during electrophysiology (EP) procedures and requires immediate, co-ordinated, and effective treatment. However, multiple aspects of PT treatment are either not standardized or are under ongoing debate. METHODS AND RESULTS: An online questionnaire consisting of 26 multiple-choice questions was sent out to the European Heart Rhythm (EHRA) Research Network and also distributed via social media outputs. The EHRA survey was conducted between May and June 2023. A total of 213 replies were received from European (87%) and non-European countries. Ninety per cent of all participants perform interventions in dedicated EP labs equipped with different ablation platforms. In case of PT, most participants use X-ray as the main imaging modality guiding pericardial puncture, predominantly aiming for an anterior puncture site. Sheaths of different sizes are introduced into the pericardial space (84.3%), followed by a pigtail catheter. Application of protamine is an established but variable step in the majority (84.6%). Novel oral anticoagulants (NOAC) antidotes are not used by 73.3% of participants, while 15.2% routinely apply them. Re-transfusion of aspirated blood is performed by 72.1% [before protamine administration (18.2%), after protamine administration (13.5%), if pericardial effusion cannot be controlled (40.4%)]. A total of 72.4% re-transfuse without blood filter systems. A decision for surgical intervention is mostly taken if bleeding continues despite all interventional measures. CONCLUSION: The current survey demonstrates that the management of PT is heterogeneous among centres. The findings of this survey may help to guide operators in their treatment and decisions in the setting of PT.


Assuntos
Anticoagulantes , Tamponamento Cardíaco , Humanos , Anticoagulantes/uso terapêutico , Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/prevenção & controle , Inquéritos e Questionários , Protaminas , Eletrofisiologia
14.
Herzschrittmacherther Elektrophysiol ; 33(4): 467-475, 2022 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-36342506

RESUMO

In this article, typical characteristics of focal atrial tachycardias are described and a systematic approach regarding diagnostics and treatment options in the field of invasive cardiac electrophysiology (EP) is presented. Subjects of this article include the definition of focal atrial tachycardias, knowledge about localizing the origin of such, and guidance on how to approach an invasive EP study (e.g., administration of medication during the EP study to provoke tachycardias). Further, descriptions will be found on how to localize the origin of focal atrial tachycardias with the help of the 12-lead ECG and invasive three-dimensional mapping to successfully treat focal atrial tachycardias with catheter ablation.


Assuntos
Ablação por Cateter , Taquicardia Atrial Ectópica , Humanos , Ablação por Cateter/métodos , Taquicardia/cirurgia , Eletrocardiografia/métodos
16.
Herzschrittmacherther Elektrophysiol ; 33(3): 341-350, 2022 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-35986095

RESUMO

In contrast to typical atrial flutter, atypical atrial flutter is a heterogeneous group of right and left atrial macro- or localized reentry tachycardias whose critical component for maintaining tachycardia is not the cavotricuspid isthmus. Atypical atrial flutter occurs more frequently after previous catheter ablation and after cardiac surgery. The intraprocedural success rate during ablation is high, although the recurrence rate depends on structural changes in the atria as well as the underlying mechanism. This article provides an overview of the mechanisms as well as mapping and ablation strategies of the most common forms of right and left atrial atypical atrial flutter. This article is part of the "EP Basics" series for targeted continuing education in invasive electrophysiology. Basics, clinic and therapy of atypical atrial flutter are presented with focus on clinically relevant aspects. Procedures and findings of invasive electrophysiological diagnostics and ablation treatment are the focus of this article.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Humanos , Taquicardia/cirurgia
18.
Circ Arrhythm Electrophysiol ; 15(6): e010817, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35617232

RESUMO

BACKGROUND: Pulsed field ablation represents an energy source specific for ablation of cardiac arrhythmias including atrial fibrillation. The aim of the study was to describe the adoption and the process of streamlining procedures with a new ablation technology. METHODS: All-comer atrial fibrillation patients (n=191; mean age 69±12 years) underwent catheter ablation with a pulsed field ablation ablation device exclusively using analog-sedation. In the validation phase (n=25), device electrogram quality was compared with a circular mapping catheter to assess pulmonary vein isolation and esophageal temperature monitoring was used. In the streamline phase (n=166), a single-catheter approach was implemented. Postprocedural cerebral magnetic resonance imaging was performed in 53 patients. In 52 patients, esophageal endoscopy was performed at day 1 after the procedure. Follow-up was performed using 72 hours Holter ECGs. RESULTS: On a pulmonary vein basis, pulmonary vein isolation rate was 100% including a single shot isolation rate of 99.5%. The electrogram information of the pulsed field ablation catheter and the circular mapping catheter were 100% congruent. Neither esophageal temperature rises nor esophageal thermal injury were observed. Two minor strokes occurred, presumable due to air embolism during catheter exchanges through the large bore sheath (13.8 F ID). In the streamline phase, reduced procedure times (46±14 versus 38±13 minutes, P=0.004), no further strokes and a low incidence of silent cerebral injury (10/53 patients; 19%) were noted. During short-term follow-up, 17/191 patients (9%) had a atrial tachyarrhythmia recurrence. CONCLUSIONS: The pulsed field ablation device allows for simple and safe simple single shot pulmonary vein isolation using standard sedation protocols. Procedural speed and efficacy are remarkable and streamlining measures have added safety.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
19.
JACC Case Rep ; 4(5): 301-305, 2022 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-35257107

RESUMO

Persistent left superior vena cava (PLSVC) is a known arrhythmogenesis site in patients with atrial fibrillation. However, the optimal PLSVC isolation approach has remained unclear because of the potential risk of complications. The current study reports 2 cases of successful electrical PLSVC isolation using pulsed field ablation. (Level of Difficulty: Intermediate.).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA