Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Am Coll Cardiol ; 71(17): 1841-1853, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29699609

RESUMO

BACKGROUND: The risk of surgical mitral valve replacement in patients with severe mitral annular calcification (MAC) is high. Several patients worldwide with severe MAC have been treated successfully with transcatheter mitral valve replacement (TMVR) using balloon-expandable aortic transcatheter valves. The TMVR in MAC Global Registry is a multicenter registry that collects data on outcomes of these procedures. OBJECTIVES: The goal of this study was to evaluate 1-year outcomes in this registry. METHODS: This study was a multicenter retrospective review of clinical outcomes. RESULTS: A total of 116 extreme surgical risk patients with severe MAC underwent TMVR; 106 had a procedure date >1 year before data-lock and were included in the analysis. Their mean age was 73 ± 12 years, and 68% were female. The mean Society of Thoracic Surgeons score was 15.3 ± 11.6%, and 90% were in New York Heart Association functional class III or IV. Thirty-day and 1-year all-cause mortality was 25% and 53.7%, respectively. Most patients who survived 30 days were alive at 1 year (49 of 77 [63.6%]), and the majority (71.8%) were in New York Heart Association functional class I or II. Echocardiography data at 1 year were available in 34 patients. Mean left ventricular ejection fraction was 58.6 ± 11.2%, mean mitral valve area was 1.9 ± 0.5 cm2, mean mitral gradient was 5.8 ± 2.2 mm Hg, and 75% had zero or trace mitral regurgitation. CONCLUSIONS: TMVR with balloon-expandable aortic valves in extreme surgical risk patients with severe MAC is feasible but associated with high 30-day and 1-year mortality. Most patients who survive the 30-day post-procedural period are alive at 1 year and have sustained improvement of symptoms and transcatheter valve performance. The role of TMVR in patients with MAC requires further evaluation in clinical trials.


Assuntos
Procedimentos Endovasculares/mortalidade , Implante de Prótese de Valva Cardíaca/mortalidade , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/mortalidade , Valva Mitral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Anuloplastia da Valva Mitral/efeitos adversos , Estudos Retrospectivos , Obstrução do Fluxo Ventricular Externo/etiologia
2.
JACC Cardiovasc Interv ; 9(13): 1361-71, 2016 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-27388824

RESUMO

OBJECTIVES: This study sought to evaluate the outcomes of the early experience of transcatheter mitral valve replacement (TMVR) with balloon-expandable valves in patients with severe mitral annular calcification (MAC) and reports the first large series from a multicenter global registry. BACKGROUND: The risk of surgical mitral valve replacement in patients with severe MAC is high. There are isolated reports of successful TMVR with balloon-expandable valves in this patient population. METHODS: We performed a multicenter retrospective review of clinical outcomes of patients with severe MAC undergoing TMVR. RESULTS: From September 2012 to July of 2015, 64 patients in 32 centers underwent TMVR with compassionate use of balloon-expandable valves. Mean age was 73 ± 13 years, 66% were female, and mean Society of Thoracic Surgeons score was 14.4 ± 9.5%. The mean mitral gradient was 11.45 ± 4.4 mm Hg and the mean mitral area was 1.18 ± 0.5 cm(2). SAPIEN valves (Edwards Lifesciences, Irvine, California) were used in 7.8%, SAPIEN XT in 59.4%, SAPIEN 3 in 28.1%, and Inovare (Braile Biomedica, Brazil) in 4.7%. Access was transatrial in 15.6%, transapical in 43.8%, and transseptal in 40.6%. Technical success according to Mitral Valve Academic Research Consortium criteria was achieved in 46 (72%) patients, primarily limited by the need for a second valve in 11 (17.2%). Six (9.3%) had left ventricular tract obstruction with hemodynamic compromise. Mean mitral gradient post-procedure was 4 ± 2.2 mm Hg, paravalvular regurgitation was mild or absent in all. Thirty-day all-cause mortality was 29.7% (cardiovascular = 12.5% and noncardiac = 17.2%); 84% of the survivors with follow-up data available were in New York Heart Association functional class I or II at 30 days (n = 25). CONCLUSIONS: TMVR with balloon-expandable valves in patients with severe MAC is feasible but may be associated with significant adverse events. This strategy might be an alternative for selected high-risk patients with limited treatment options.


Assuntos
Calcinose/cirurgia , Cateterismo Cardíaco/métodos , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Valvuloplastia com Balão , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Europa (Continente) , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , América do Norte , Seleção de Pacientes , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , América do Sul , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
J Robot Surg ; 6(4): 345-8, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27628476

RESUMO

Diaphragmatic paralysis is an uncommon condition characterized by significant elevation of a hemidiaphragm, and can cause dyspnea. The goal of diaphragm plication is to improve dyspnea by correcting the dysfunctional movement of a diaphragm during inspiration. Minimally invasive thoracoscopic diaphragm plication has been widely used and has been reported to lead to significant improvements in dyspnea and postoperative pulmonary function. Advantages of thoracoscopic plication compared to open thoracotomy are less postoperative pain and shorter hospitalization, yet technical difficulties due to limited workspace afforded by the ribcage and the elevated hemidiaphragm have been a major drawback in using the thoracoscopic approach for this disorder. We describe our experience with robotic thoracoscopic plication for the treatment of diaphragmatic paralysis. This is, to our knowledge, the first report of this kind.

5.
J Robot Surg ; 6(4): 355-7, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27628478

RESUMO

In this manuscript we report a case of fully robotic thoracoscopic resection of intralobar pulmonary sequestration. The Da Vinci robot provides surgeons with great three-dimensional visualization and enhanced dexterity. This enables a safer, more precise dissection of sequestered pulmonary tissue. Robotic technology may result in fewer complications and less conversions to open surgery in cases of pulmonary sequestration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA