Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
1.
Sci Rep ; 14(1): 8554, 2024 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609397

RESUMO

Cold water immersion (CWI) involves rapid cooling of the body, which, in healthy individuals, triggers a defence response to an extreme stimulus, to which the body reacts with stress. The aim of the study was to determine the effect of CWI on hemorheological blood indicators. The study group consisted of 13 young males. Blood samples were collected before and after CWI. The assessed parameters included the complete blood count, fibrinogen, hs-C-reactive protein (CRP), proteinogram, and blood rheology factors, such as erythrocyte elongation index (EI), half-time of total aggregation, and aggregation index. Additionally, the effect of reduced temperature on primary human vascular endothelium was investigated in vitro. CWI resulted in the decrease of body temperature to 31.55 ± 2.87 °C. After CWI, neutrophil count and mean corpuscular volume (MCV) were significantly increased in the study group, while lymphocyte count was significantly decreased. Significantly higher levels of total blood protein and albumin concentration were detected after the immersion. Among hemorheological characteristics, erythrocyte EIs at shear stress values ranging from 2.19 to 60.30 Pa were significantly lower after CWI. No significant changes in other rheological, morphological or biochemical parameters were observed. In vitro, human umbilical vein endothelial cells responded to 3 h of temperature decrease to 25 °C with unchanged viability, but increased recruitment of THP-1 monocytic cells and changes in cell morphology were observed. This was the first study to evaluate the effect of single CWI on rheological properties of blood in healthy young men. The results indicate that a single CWI may increase blood protein concentrations and worsen erythrocyte deformability parameters.


Assuntos
Hemorreologia , Imersão , Masculino , Humanos , Contagem de Leucócitos , Proteína C-Reativa , Células Endoteliais da Veia Umbilical Humana
2.
Int J Nanomedicine ; 19: 1645-1666, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38406599

RESUMO

Purpose: In this study, a detailed characterization of a rabbit model of atherosclerosis was performed to assess the optimal time frame for evaluating plaque vulnerability using superparamagnetic iron oxide nanoparticle (SPION)-enhanced magnetic resonance imaging (MRI). Methods: The progression of atherosclerosis induced by ballooning and a high-cholesterol diet was monitored using angiography, and the resulting plaques were characterized using immunohistochemistry and histology. Morphometric analyses were performed to evaluate plaque size and vulnerability features. The accumulation of SPIONs (novel dextran-coated SPIONDex and ferumoxytol) in atherosclerotic plaques was investigated by histology and MRI and correlated with plaque age and vulnerability. Toxicity of SPIONDex was evaluated in rats. Results: Weak positive correlations were detected between plaque age and intima thickness, and total macrophage load. A strong negative correlation was observed between the minimum fibrous cap thickness and plaque age as well as the mean macrophage load. The accumulation of SPION in the atherosclerotic plaques was detected by MRI 24 h after administration and was subsequently confirmed by Prussian blue staining of histological specimens. Positive correlations between Prussian blue signal in atherosclerotic plaques, plaque age, and macrophage load were detected. Very little iron was observed in the histological sections of the heart and kidney, whereas strong staining of SPIONDex and ferumoxytol was detected in the spleen and liver. In contrast to ferumoxytol, SPIONDex administration in rabbits was well tolerated without inducing hypersensitivity. The maximum tolerated dose in rat model was higher than 100 mg Fe/kg. Conclusion: Older atherosclerotic plaques with vulnerable features in rabbits are a useful tool for investigating iron oxide-based contrast agents for MRI. Based on the experimental data, SPIONDex particles constitute a promising candidate for further clinical translation as a safe formulation that offers the possibility of repeated administration free from the risks associated with other types of magnetic contrast agents.


Assuntos
Aterosclerose , Compostos Férricos , Ferrocianetos , Nanopartículas de Magnetita , Placa Aterosclerótica , Coelhos , Ratos , Animais , Meios de Contraste/química , Placa Aterosclerótica/induzido quimicamente , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Óxido Ferroso-Férrico , Nanopartículas de Magnetita/química , Aterosclerose/induzido quimicamente , Aterosclerose/diagnóstico por imagem , Aterosclerose/patologia , Imageamento por Ressonância Magnética/métodos
4.
Molecules ; 28(20)2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37894531

RESUMO

BACKGROUND: Whey protein isolate (WPI) is a by-product from the dairy industry, whose main component is ß-lactoglobulin. Upon heating, WPI forms a hydrogel which can both support controlled drug delivery and enhance the proliferation and osteogenic differentiation of bone-forming cells. This study makes a novel contribution by evaluating the ability of WPI hydrogels to support the growth of endothelial cells, which are essential for vascularization, which in turn is a pre-requisite for bone regeneration. METHODS: In this study, the proliferation and antioxidant levels in human umbilical vascular endothelial cells (HUVECs) cultured with WPI supplementation were evaluated using real-time cell analysis and flow cytometry. Further, the attachment and growth of HUVECs seeded on WPI-based hydrogels with different concentrations of WPI (15%, 20%, 30%, 40%) were investigated. RESULTS: Supplementation with WPI did not affect the viability or proliferation of HUVECs monitored with real-time cell analysis. At the highest used concentration of WPI (500 µg/mL), a slight induction of ROS production in HUVECs was detected as compared with control samples, but it was not accompanied by alterations in cellular thiol levels. Regarding WPI-based hydrogels, HUVEC adhered and spread on all samples, showing good metabolic activity. Notably, cell number was highest on samples containing 20% and 30% WPI. CONCLUSIONS: The demonstration of the good compatibility of WPI hydrogels with endothelial cells in these experiments is an important step towards promoting the vascularization of hydrogels upon implantation in vivo, which is expected to improve implant outcomes in the future.


Assuntos
Células Endoteliais , Osteogênese , Humanos , Proteínas do Soro do Leite/farmacologia , Hidrogéis/farmacologia , Diferenciação Celular , Alicerces Teciduais
5.
Bioengineering (Basel) ; 10(7)2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37508876

RESUMO

The traditional 3D culture systems in vitro lack the biological and mechanical spatiotemporal stimuli characteristic to native tissue development. In our study, we combined porous polysaccharide-based hydrogel scaffolds with a bioreactor-type perfusion device that generates favorable mechanical stresses while enhancing nutrient transfers. MC3T3E1 mouse osteoblasts were seeded in the scaffolds and cultivated for 3 weeks under dynamic conditions at a perfusion rate of 10 mL min-1. The spatial distribution of the cells labeled with superparamagnetic iron oxide nanoparticles was visualized by MRI. Confocal microscopy was used to assess cell numbers, their distribution inside the scaffolds, cell viability, and proliferation. The oxygen diffusion coefficient in the hydrogel was measured experimentally. Numerical simulations of the flow and oxygen transport within the bioreactor were performed using a lattice Boltzmann method with a two-relaxation time scheme. Last, the influence of cell density and spheroid size on cell oxygenation was investigated. The cells spontaneously organized into spheroids with a diameter of 30-100 µm. Cell viability remained unchanged under dynamic conditions but decreased under static culture. The cell proliferation (Ki67 expression) in spheroids was not observed. The flow simulation showed that the local fluid velocity reached 27 mm s-1 at the height where the cross-sectional area of the flow was the smallest. The shear stress exerted by the fluid on the scaffolds may locally rise to 100 mPa, compared with the average value of 25 mPa. The oxygen diffusion coefficient in the hydrogel was 1.6×10-9 m2 s-1. The simulation of oxygen transport and consumption confirmed that the cells in spheroids did not suffer from hypoxia when the bioreactor was perfused at 10 mL min-1, and suggested the existence of optimal spheroid size and spacing for appropriate oxygenation. Collectively, these findings enabled us to define the optimal conditions inside the bioreactor for an efficient in vitro cell organization and survival in spheroids, which are paramount to future applications with organoids.

7.
Int J Nanomedicine ; 18: 2071-2086, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37113796

RESUMO

Introduction: One of the major challenges in the clinical translation of nanoparticles is the development of formulations combining favorable efficacy and optimal safety. In the past, iron oxide nanoparticles have been introduced as an alternative for gadolinium-containing contrast agents; however, candidates available at the time were not free from adverse effects. Methods: Following the development of a potent iron oxide-based contrast agent SPIONDex, we now performed a systematic comparison of this formulation with the conventional contrast agent ferucarbotran and with ferumoxytol, taking into consideration their physicochemical characteristics, bio- and hemocompatibility in vitro and in vivo, as well as their liver imaging properties in rats. Results: The results demonstrated superior in vitro cyto-, hemo- and immunocompatibility of SPIONDex in comparison to the other two formulations. Intravenous administration of ferucarbotran or ferumoxytol induced strong complement activation-related pseudoallergy in pigs. In contrast, SPIONDex did not elicit any hypersensitivity reactions in the experimental animals. In a rat model, comparable liver imaging properties, but a faster clearance was demonstrated for SPIONDex. Conclusion: The results indicate that SPIONDex possess an exceptional safety compared to the other two formulations, making them a promising candidate for further clinical translation.


Assuntos
Meios de Contraste , Nanopartículas de Magnetita , Ratos , Animais , Suínos , Óxido Ferroso-Férrico , Segurança do Paciente , Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita/toxicidade
8.
J Biol Eng ; 17(1): 20, 2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36915145

RESUMO

BACKGROUND: In this study, two types of polyurethane-based cylindrical multilayered grafts with internal diameters ≤ 6 mm were produced by the solution blow spinning (SBS) method. The main aim was to create layered-wall prostheses differing in their luminal surface morphology. Changing the SBS process parameters, i.e. working distance, rotational speed, volume, and concentration of the polymer solution allowed to obtain structures with the required morphologies. The first type of prostheses, termed Nano, possessed nanofibrous luminal surface, and the second type, Micro, presented morphologically diverse luminal surface, with both solid and microfibrous areas. RESULTS: The results of mechanical tests confirmed that designed prostheses had high flexibility (Young's modulus value of about 2.5 MPa) and good tensile strength (maximum axial load value of about 60 N), which meet the requirements for vascular prostheses. The influence of the luminal surface morphology on platelet adhesion and the attachment of endothelial cells was investigated. Both surfaces did not cause hemolysis in contact with blood, the percentage of platelet-occupied area for Nano and Micro surfaces was comparable to reference polytetrafluoroethylene (PTFE) surface. However, the change in morphology of surface-adhered platelets between Nano and Micro surfaces was visible, which might suggest differences in their activation level. Endothelial coverage after 1, 3, and 7 days of culture on flat samples (2D model) was higher on Nano prostheses as compared with Micro scaffolds. However, this effect was not seen in 3D culture, where cylindrical prostheses were colonized using magnetic seeding method. CONCLUSIONS: We conclude the produced scaffolds meet the material and mechanical requirements for vascular prostheses. However, changing the morphology without changing the chemical modification of the luminal surface is not sufficient to achieve the appropriate effectiveness of endothelialization in the 3D model.

9.
Biomacromolecules ; 24(3): 1497-1510, 2023 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-36786807

RESUMO

This study aimed to develop a suitable hydrogel-based 3D platform to support long-term culture of primary endothelial cells (ECs) and fibroblasts. Two hydrogel systems based on allyl-modified gelatin (gelAGE), G1MM and G2LH, were cross-linked via thiol-ene click reaction with a four-arm thiolated polyethylene glycol (PEG-4-SH). Compared to G1MM, the G2LH hydrogel was characterized by the lower polymer content and cross-linking density with a softer matrix and homogeneous and open porosity. Cell viability in both hydrogels was comparable, although the G2LH-based platform supported better F-actin organization, cell-cell interactions, and collagen and fibronectin production. In co-cultures, early morphogenesis leading to tubular-like structures was observed within 2 weeks. Migration of fibroblasts out of spheroids embedded in the G2LH hydrogels started after 5 days of incubation. Taken together, the results demonstrated that the G2LH hydrogel fulfilled the demands of both ECs and fibroblasts to enable long-term culture and matrix remodeling.


Assuntos
Células Endoteliais , Hidrogéis , Humanos , Hidrogéis/química , Fibroblastos , Colágeno/química , Gelatina/química , Polietilenoglicóis/química
11.
Biomolecules ; 12(9)2022 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-36139035

RESUMO

Biosensor-integrated drug delivery systems are innovative devices in the health area, enabling continuous monitoring and drug administration. The use of smart polymer, bioMEMS, and electrochemical sensors have been extensively studied for these systems, especially for chronic diseases such as diabetes mellitus, cancer and cardiovascular diseases as well as advances in regenerative medicine. Basically, the technology involves sensors designed for the continuous analysis of biological molecules followed by drug release in response to specific signals. The advantages include high sensitivity and fast drug release. In this work, the main advances of biosensor-integrated drug delivery systems as new biomedical materials to improve the patients' quality of life with chronic diseases are discussed.


Assuntos
Técnicas Biossensoriais , Polímeros Responsivos a Estímulos , Doença Crônica , Sistemas de Liberação de Medicamentos , Humanos , Preparações Farmacêuticas , Qualidade de Vida
12.
Biomater Adv ; 134: 112544, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35525759

RESUMO

Rapid endothelialization helps overcome the limitations of small-diameter vascular grafts. To develop biomimetic non-thrombogenic coatings supporting endothelialization, medical-grade polyurethane (PU) nanofibrous mats and tubular scaffolds with a diameter below 6 mm prepared by solution blow spinning were coated with polydopamine (PDA), or PDA and gelatin (PDA/Gel). The scaffolds were characterized by scanning electron microscopy, porosity measurement, tensile testing, wettability, Fourier Transform Infrared spectroscopy, and termogravimetric analysis, followed by the measurement of coating stability on the tubular scaffolds. The effect of coating on scaffold endothelialization and hemocompatibility was evaluated using human umbilical vein endothelial cells (HUVECs) and human platelets, showing low numbers of adhering platelets and significantly higher numbers of HUVECs on PDA- and PDA/Gel-coated mats compared to control samples. Tubular PU scaffolds and commercial ePTFE prostheses coated with PDA or PDA/Gel were colonized with HUVECs using radial magnetic cell seeding. PDA/Gel-coated samples achieved full endothelial coverage within 1-3 days post-endothelialization. Altogether, PDA and PDA/Gel coating significantly enhance the endothelialization on the flat surfaces, tubular small-diameter scaffolds, and commercial vascular prostheses. The presented approach constitutes a fast and efficient method of improving scaffold colonization with endothelial cells, expected to work equally well upon implantation.


Assuntos
Materiais Revestidos Biocompatíveis , Gelatina , Prótese Vascular , Materiais Revestidos Biocompatíveis/química , Gelatina/farmacologia , Células Endoteliais da Veia Umbilical Humana , Humanos , Indóis , Polímeros , Poliuretanos/química
13.
Cancer Med ; 11(24): 4743-4755, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35578404

RESUMO

BACKGROUND: Extramedullary plasmacytoma (EMP) is a solitary tumor consisting of neoplastic plasma cells, with very little to no bone marrow involvement. EMPs are usually located in the head and neck region, but can also occur along the digestive tract, in lungs, or extremities. METHODS: Following our publication on EMP, which appeared in 1999 (Cancer 85:2305-14), we conducted a literature search for EMP-related reports published between 1999 and 2021. The documented cases, as well as 14 of our own patients from the ENT Clinic Erlangen, were extensively analyzed. RESULTS: Between 1998 and 2021, 1134 patients with EMP were reported, for whom information about the tumor localization was available. Among those, 62.4% had EMP in the head and neck area and 37.6% in other body regions. Data on therapy were reported in 897 patients, including 34.3% who received radiation, 28.1% surgery, 22.6% a combination of surgery and radiation, and 15.9% another therapy. In 76.9% patients no recurrence or transformation to multiple myeloma (MM) was reported, 12.8% showed local recurrence and 10.2% developed MM. Radiotherapy alone was associated with a tendency for increased occurrence of MM. In patients with EMP of head and neck area, combination therapy (surgery and radiation) resulted in a 5-year overall survival rate of 98.3%, surgery alone of 92.4%, and radiotherapy of 92.7%. CONCLUSIONS: Collectively, our analyses indicate that surgical resection alone can achieve long-term tumor control in patients with EMP, if the tumor can be removed within safe limits without causing serious functional impairment. However, if this is not certain, either radiation or a combination of surgery and radiation therapy is suggested as an effective means of local tumor control.


Assuntos
Mieloma Múltiplo , Plasmocitoma , Humanos , Plasmocitoma/patologia , Seguimentos , Taxa de Sobrevida , Terapia Combinada
14.
Int J Nanomedicine ; 17: 2139-2163, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35599750

RESUMO

Label-free detection of nanoparticles is essential for a thorough evaluation of their cellular effects. In particular, nanoparticles intended for medical applications must be carefully analyzed in terms of their interactions with cells, tissues, and organs. Since the labeling causes a strong change in the physicochemical properties and thus also alters the interactions of the particles with the surrounding tissue, the use of fluorescently labeled particles is inadequate to characterize the effects of unlabeled particles. Further, labeling may affect cellular uptake and biocompatibility of nanoparticles. Thus, label-free techniques have been recently developed and implemented to ensure a reliable characterization of nanoparticles. This review provides an overview of frequently used label-free visualization techniques and highlights recent studies on the development and usage of microscopy systems based on reflectance, darkfield, differential interference contrast, optical coherence, photothermal, holographic, photoacoustic, total internal reflection, surface plasmon resonance, Rayleigh light scattering, hyperspectral and reflectance structured illumination imaging. Using these imaging modalities, there is a strong enhancement in the reliability of experiments concerning cellular uptake and biocompatibility of nanoparticles, which is crucial for preclinical evaluations and future medical applications.


Assuntos
Microscopia , Nanopartículas , Nanopartículas/química , Reprodutibilidade dos Testes , Ressonância de Plasmônio de Superfície
15.
Adv Mater ; 34(28): e2200653, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35595711

RESUMO

A facile and flexible approach for the integration of biomimetically branched microvasculature within bulk hydrogels is presented. For this, sacrificial scaffolds of thermoresponsive poly(2-cyclopropyl-2-oxazoline) (PcycloPrOx) are created using melt electrowriting (MEW) in an optimized and predictable way and subsequently placed into a customized bioreactor system, which is then filled with a hydrogel precursor solution. The aqueous environment above the lower critical solution temperature (LCST) of PcycloPrOx at 25 °C swells the polymer without dissolving it, resulting in fusion of filaments that are deposited onto each other (print-and-fuse approach). Accordingly, an adequate printing pathway design results in generating physiological-like branchings and channel volumes that approximate Murray's law in the geometrical ratio between parent and daughter vessels. After gel formation, a temperature decrease below the LCST produces interconnected microchannels with distinct inlet and outlet regions. Initial placement of the sacrificial scaffolds in the bioreactors in a pre-defined manner directly yields perfusable structures via leakage-free fluid connections in a reproducible one-step procedure. Using this approach, rapid formation of a tight and biologically functional endothelial layer, as assessed not only through fluorescent dye diffusion, but also by tumor necrosis factor alpha (TNF-α) stimulation, is obtained within three days.


Assuntos
Hidrogéis , Alicerces Teciduais , Endotélio , Hidrogéis/química , Microvasos , Impressão Tridimensional , Engenharia Tecidual/métodos , Alicerces Teciduais/química
18.
Nanomaterials (Basel) ; 11(9)2021 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-34578651

RESUMO

In recent years, many promising nanotechnological approaches to biomedical research have been developed in order to increase implementation of regenerative medicine and tissue engineering in clinical practice. In the meantime, the use of nanomaterials for the regeneration of diseased or injured tissues is considered advantageous in most areas of medicine. In particular, for the treatment of cardiovascular, osteochondral and neurological defects, but also for the recovery of functions of other organs such as kidney, liver, pancreas, bladder, urethra and for wound healing, nanomaterials are increasingly being developed that serve as scaffolds, mimic the extracellular matrix and promote adhesion or differentiation of cells. This review focuses on the latest developments in regenerative medicine, in which iron oxide nanoparticles (IONPs) play a crucial role for tissue engineering and cell therapy. IONPs are not only enabling the use of non-invasive observation methods to monitor the therapy, but can also accelerate and enhance regeneration, either thanks to their inherent magnetic properties or by functionalization with bioactive or therapeutic compounds, such as drugs, enzymes and growth factors. In addition, the presence of magnetic fields can direct IONP-labeled cells specifically to the site of action or induce cell differentiation into a specific cell type through mechanotransduction.

20.
Int J Mol Sci ; 22(8)2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33923700

RESUMO

Hydroxyapatite- or calcium phosphate-coated iron oxide nanoparticles have a high potential for use in many biomedical applications. In this study, a co-precipitation method for the synthesis of hydroxyapatite-coated nanoparticles (SPIONHAp), was used. The produced nanoparticles have been characterized by dynamic light scattering, X-ray diffraction, vibrating sample magnetometry, Fourier transform infrared spectrometry, atomic emission spectroscopy, scanning electron microscopy, transmission electron microscopy, selected area diffraction, and energy-dispersive X-ray spectroscopy. The results showed a successful synthesis of 190 nm sized particles and their stable coating, resulting in SPIONHAp. Potential cytotoxic effects of SPIONHAp on EL4, THP-1, and Jurkat cells were tested, showing only a minor effect on cell viability at the highest tested concentration (400 µg Fe/mL). The results further showed that hydroxyapatite-coated SPIONs can induce minor TNF-α and IL-6 release by murine macrophages at a concentration of 100 µg Fe/mL. To investigate if and how such particles interact with other substances that modulate the immune response, SPIONHAp-treated macrophages were incubated with LPS (lipopolysaccharides) and dexamethasone. We found that cytokine release in response to these potent pro- and anti-inflammatory agents was modulated in the presence of SPIONHAp. Knowledge of this behavior is important for the management of inflammatory processes following in vivo applications of this type of SPIONs.


Assuntos
Interleucina-6/metabolismo , Nanopartículas Magnéticas de Óxido de Ferro/química , Fator de Necrose Tumoral alfa/metabolismo , Animais , Células da Medula Óssea/efeitos dos fármacos , Células da Medula Óssea/metabolismo , Células Cultivadas , Durapatita/química , Humanos , Células Jurkat , Lipopolissacarídeos/toxicidade , Macrófagos/efeitos dos fármacos , Macrófagos/metabolismo , Nanopartículas Magnéticas de Óxido de Ferro/toxicidade , Camundongos , Camundongos Endogâmicos C57BL , Células THP-1
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA