Assuntos
Injúria Renal Aguda , COVID-19 , Humanos , Injúria Renal Aguda/etiologia , COVID-19/complicações , SARS-CoV-2 , Masculino , IdosoRESUMO
Dialysis patients are a risk group for SARS-CoV-2 infection and possibly further complications, but we have little information. The aim of this paper is to describe the experience of the first month of the SARS-CoV-2 pandemic in a hospital haemodialysis (HD) unit serving the district of Madrid with the second highest incidence of COVID-19 (almost 1,000 patients in 100,000h). In the form of a diary, we present the actions undertaken, the incidence of COVID-19 in patients and health staff, some clinical characteristics and the results of screening all the patients in the unit. We started with 90 patients on HD: 37 (41.1%) had COVID-19, of whom 17 (45.9%) were diagnosed through symptoms detected in triage or during the session, and 15 (40.5%) through subsequent screening of those who, until that time, had not undergone SARS-CoV-2 PCR testing. Fever was the most frequent symptom, 50% had lymphopenia and 18.4% <95% O2 saturation. Sixteen (43.2%) patients required hospital admission and 6 (16.2%) died. We found a cluster of infection per shift and also among those using public transport. In terms of staff, of the 44 people involved, 15 (34%) had compatible symptoms, 4 (9%) were confirmed as SARS-CoV-2 PCR cases by occupational health, 9 (20%) required some period of sick leave, temporary disability to work (ILT), and 5 were considered likely cases. CONCLUSIONS: We detected a high prevalence of COVID-19 with a high percentage detected by screening; hence the need for proactive diagnosis to stop the pandemic. Most cases are managed as outpatients, however severe symptoms are also appearing and mortality to date is 16.2%. In terms of staff, 20% have required sick leave in relation to COVID-19.
Assuntos
Infecções Assintomáticas/epidemiologia , Betacoronavirus , Infecções por Coronavirus/epidemiologia , Pessoal de Saúde/estatística & dados numéricos , Unidades Hospitalares de Hemodiálise/estatística & dados numéricos , Pandemias , Pneumonia Viral/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19 , Protocolos Clínicos , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/tratamento farmacológico , Feminino , Pessoal de Saúde/organização & administração , Unidades Hospitalares de Hemodiálise/organização & administração , Humanos , Incidência , Linfopenia/epidemiologia , Masculino , Pessoa de Meia-Idade , Pneumonia Viral/diagnóstico , Pneumonia Viral/tratamento farmacológico , Prevalência , SARS-CoV-2 , Espanha/epidemiologia , Avaliação de Sintomas , Fatores de Tempo , Triagem/métodos , Adulto JovemRESUMO
BACKGROUND/AIMS: A recent alert from Spanish health authorities warned of a higher incidence of reported hypersensitivity reactions to hemodialysis membranes with polysulfone, in the 2017 review of acute reactions to dialyzers found only published reports in the 21st century on polysulfone and its derivatives. The aim is to assess/evaluate the current incidence and characteristics of hypersensitivity reactions in hemodialysis patients. METHODS: A retrospective multicentre study in 9 Spanish hospitals evaluated patients in whom a hypersensitivity reaction required a change in dialyzer membrane. RESULTS: A total of 37 patients out of 1561 (2.37%) had hypersensitivity reactions and clinical, epidemiological and analytical data were available for 33 patients (2.11%). The membranes involved were polysulfone (n=23), polynephron (n=8), polyethersulfone (n=1) and polyacrylonitrile (n=1). This distribution reflected the frequency of use of membranes in the participating dialysis units. The reactions were described as type A in 18 cases and type B in 15 cases. There were no significant differences between the two types in clinical symptoms, the composition of the membrane involved, the method of sterilization, the season, or the time during the session in which they occurred. The most frequent symptom was dyspnea/breathlessness (64% of reactions). Eosinophilia was common (74%). 54% of the reactions occurred within the first 30 minutes of hemodialysis, 64% occurred during the first year of dialysis, and 54% required discontinuation of dialysis session. Cellulose triacetate was used as an alternative dialyzer in 78% of the cases. CONCLUSION: The incidence of hypersensitivity reactions was in the range found in reports from 20 years ago and is observed associated with synthetic membranes, not just polysulfones. Cellulose triacetate appears to be a good alternative for these patients.