Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
1.
Front Immunol ; 15: 1362995, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38596676

RESUMO

Introduction: Common Variable Immunodeficiency (CVID) patients are characterized by hypogammaglobulinemia and poor response to vaccination due to deficient generation of memory and antibody-secreting B cells. B lymphocytes are essential for the development of humoral immune responses, and mitochondrial function, hreactive oxygen species (ROS) production and autophagy are crucial for determining B-cell fate. However, the role of those basic cell functions in the differentiation of human B cells remains poorly investigated. Methods: We used flow cytometry to evaluate mitochondrial function, ROS production and autophagy processes in human naïve and memory B-cell subpopulations in unstimulated and stimulated PBMCs cultures. We aimed to determine whether any alterations in these processes could impact B-cell fate and contribute to the lack of B-cell differentiation observed in CVID patients. Results: We described that naïve CD19+CD27- and memory CD19+CD27+ B cells subpopulations from healthy controls differ in terms of their dependence on these processes for their homeostasis, and demonstrated that different stimuli exert a preferential cell type dependent effect. The evaluation of mitochondrial function, ROS production and autophagy in naïve and memory B cells from CVID patients disclosed subpopulation specific alterations. Dysfunctional mitochondria and autophagy were more prominent in unstimulated CVID CD19+CD27- and CD19+CD27+ B cells than in their healthy counterparts. Although naïve CD19+CD27- B cells from CVID patients had higher basal ROS levels than controls, their ROS increase after stimulation was lower, suggesting a disruption in ROS homeostasis. On the other hand, memory CD19+CD27+ B cells from CVID patients had both lower ROS basal levels and a diminished ROS production after stimulation with anti-B cell receptor (BCR) and IL-21. Conclusion: The failure in ROS cell signalling could impair CVID naïve B cell activation and differentiation to memory B cells. Decreased levels of ROS in CVID memory CD19+CD27+ B cells, which negatively correlate with their in vitro cell death and autophagy, could be detrimental and lead to their previously demonstrated premature death. The final consequence would be the failure to generate a functional B cell compartment in CVID patients.


Assuntos
Imunodeficiência de Variável Comum , Humanos , Espécies Reativas de Oxigênio/metabolismo , Membro 7 da Superfamília de Receptores de Fatores de Necrose Tumoral/metabolismo , Linfócitos B , Antígenos CD19/metabolismo , Autofagia , Mitocôndrias/metabolismo
2.
Biosens Bioelectron ; 257: 116341, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38677019

RESUMO

Origami biosensors leverage paper foldability to develop total analysis systems integrated in a single piece of paper. This capability can also be utilized to incorporate additional features that would be difficult to achieve with rigid substrates. In this article, we report a new design for 3D origami biosensors called OriPlex, which leverages the foldability of filter paper for the multiplexed detection of bacterial pathogens. OriPlex immunosensors detect pathogens by folding nanoparticle reservoirs containing different types of nanoprobes. This releases antibody-coated nanoparticles in a central channel where targets are captured through physical interactions. The OriPlex concept was demonstrated by detecting the respiratory pathogens Pseudomonas aeruginosa (PA) and Klebsiella pneumoniae (KP) with a limit of detection of 3.4·103 cfu mL-1 and 1.4·102 cfu mL-1, respectively, and with a turn-around time of 25 min. Remarkably, the OriPlex biosensors allowed the multiplexed detection of both pathogens spiked into real bronchial aspirate (BAS) samples at a concentration of 105 cfu mL-1 (clinical infection threshold), thus demonstrating their suitability for diagnosing lower tract respiratory infections. The results shown here pave the way for implementing OriPlex biosensors as a screening test for detecting superbugs requiring personalized antibiotics in suspected cases of nosocomial pneumonia.


Assuntos
Técnicas Biossensoriais , Klebsiella pneumoniae , Pseudomonas aeruginosa , Técnicas Biossensoriais/métodos , Klebsiella pneumoniae/isolamento & purificação , Pseudomonas aeruginosa/isolamento & purificação , Humanos , Limite de Detecção , Infecções por Pseudomonas/diagnóstico , Infecções por Pseudomonas/microbiologia , Desenho de Equipamento , Infecções por Klebsiella/diagnóstico , Infecções por Klebsiella/microbiologia , Infecções Respiratórias/microbiologia , Infecções Respiratórias/diagnóstico , Nanopartículas/química , Imunoensaio/métodos
3.
Sci Rep ; 14(1): 2966, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38316832

RESUMO

This paper introduces the design of a reconfigurable transmitarray operating within the D-band frequency range (110-170 GHz). The transmitarray unit cell is composed of three metal layers and two quartz dielectric substrates. It achieves a 1-bit phase shift resolution through the alternating states of two innovative switches integrated into the active transmitting patch of the unit cell. To address the challenge of miniaturization in the D-band, compact switches compatible with the proposed unit cell dimensions are introduced. These switches are constructed using phase change materials (PCM) that change between amorphous and crystalline states when exposed to heat. The paper includes a full-wave simulation of the unit cell, demonstrating an insertion loss below 1.5 dB across a wide frequency band of 27%. Additionally, a 10 [Formula: see text] 10 elements transmitarray is synthesized using a numerical tool and its theoretical results are compared to full-wave electromagnetic simulations for validation purposes. The results indicate that by incorporating the proposed switches into the unit cell, the transmitarray achieves promising reconfiguration capabilities within the D-band. Moreover, the paper presents the architecture of a command line designed to bias the PCM switches. Notably, this command line represents a novel approach, as it enables individual biasing of each PCM switch using direct current (DC). The influence of these command lines on the transmitarray's performance is thoroughly investigated. Although there is a compromise in the 1-dB gain bandwidth, the overall behavior of the transmitarray remains encouraging.

4.
Mikrochim Acta ; 190(11): 441, 2023 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-37845505

RESUMO

Detecting sputum pyocyanin (PYO) with a competitive immunoassay is a promising approach for diagnosing Pseudomonas aeruginosa respiratory infections. However, it is not possible to perform a negative control to evaluate matrix-effects in competitive immunoassays, and the highly complex sputum matrix often interferes with target detection. Here, we show that these issues are alleviated by performing competitive immunoassays with a paper biosensor. The biosensing platform consists of a paper reservoir, which contains antibody-coated gold nanoparticles, and a substrate containing a competing recognition element, which is a piece of paper modified with an albumin-antigen conjugate. Detection of PYO with a limit of detection of 4.7·10-3 µM and a dynamic range between 4.7·10-1 µM and 47.6 µM is accomplished by adding the sample to the substrate with the competing element and pressing the reservoir against it for 5 min. When tested with patient samples, the biosensor was able to qualitatively differentiate spiked from non-spiked samples, whereas ELISA did not show a clear cut-off between them. Furthermore, the relative standard deviation was lower when determining sputum with the paper-based biosensor. These features, along with a mild liquefaction step that circumvents the use of harsh chemicals or instruments, make our biosensor a good candidate for diagnosing Pseudomonas infections at the bedside through the detection of sputum PYO.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Infecções por Pseudomonas , Humanos , Piocianina/análise , Escarro/química , Ouro , Infecções por Pseudomonas/diagnóstico , Imunoensaio
5.
Analyst ; 148(19): 4837-4843, 2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37622408

RESUMO

Pseudomonas aeruginosa (P. aeruginosa) is a pathogen that persistently colonizes the respiratory tract of patients with chronic lung diseases. The risk of acquiring a chronic P. aeruginosa infection can be minimized by rapidly detecting the pathogen in the patient's airways and promptly administrating adequate antibiotics. However, the rapid detection of P. aeruginosa in the lungs involves the analysis of sputum, which is a highly complex matrix that is not always available. Here, we propose an alternative diagnosis based on analyzing breath aerosols. In this approach, nanoparticle immunosensors identify bacteria adhered to the polypropylene layer of a surgical facemask that was previously worn by the patient. A polypropylene processing protocol was optimized to ensure the efficient capture and analysis of the target pathogen. The proposed analytical platform has a theoretical limit of detection of 105 CFU mL-1 in aerosolized mock samples, and a dynamic range between 105 and 108 CFU mL-1. When tested with facemasks worn by patients, the biosensors were able to detect chronic and acute P. aeruginosa lung infections, and to differentiate them from respiratory infections caused by other pathogens. The results shown here pave the way to diagnose Pseudomonas infections at the bedside, as well as to identify the progress from chronic to acute infection.


Assuntos
Técnicas Biossensoriais , Fibrose Cística , Infecções por Pseudomonas , Humanos , Pseudomonas aeruginosa , Máscaras/efeitos adversos , Polipropilenos , Imunoensaio , Pulmão , Infecções por Pseudomonas/diagnóstico , Infecções por Pseudomonas/microbiologia
6.
Int Orthop ; 47(4): 983-993, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36752846

RESUMO

PURPOSE: Extensor mechanism disruption following total knee arthroplasty has a prevalence ranging from 0.3 to 3%. Its management is challenging, especially in case of associated infection of the prosthetic implant. Surgical options are limited due to the septic process, and the use of allograft or synthetic mesh are not recommended. The aim of this study was to report clinical outcomes, complications, survival, and surgical technique of medial gastrocnemius flap for the treatment of extensor mechanism disruptions associated with periprosthetic knee infection. METHODS: This is a retrospective study from a prospectively collected arthroplasty registry from 2012 to 2019. Patients who received the gastrocnemius flap in the setting of a two-stage knee replacement for periprosthetic infection were included. Results of physical examination, Knee Society Score, Oxford Knee Score, and measurement of the range of motion registered pre-operatively were compared to those obtained at last follow-up. Survival was analysed through Kaplan-Meier curve. RESULTS: A total of 15 patients were included, with a mean age of 63.4 years (range 36-77). The reconstruction of the extensor mechanism demonstrated a success rate of 73.3%. The mean extension lag at final follow-up was 7.5° (range, 0-30). The mean Knee Society Score and Oxford Knee Score improved from 29.0 (range, 21-36) and 17.5 (range, 13-22) respectively, to 82.9 (range, 74-89) and 36.0 (range, 33-39). CONCLUSION: Medial gastrocnemius rotational flap is a reliable option for joint and limb salvage in case of periprosthetic knee infection associated with wide soft tissue degeneration and extensor mechanism disruption. The technique and surgical protocol presented in this study are reproducible and guaranteed good clinical outcomes and infection control.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Seguimentos , Resultado do Tratamento , Músculo Esquelético/cirurgia , Articulação do Joelho/cirurgia , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Prótese do Joelho/efeitos adversos , Reoperação
7.
Arch Orthop Trauma Surg ; 143(3): 1361-1370, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35028707

RESUMO

PURPOSE: The purposes of this study were to determine demographics and characteristics of patients who underwent spacer exchange for persistent infection in the setting of two-stage arthroplasty for periprosthetic joint infection, to describe the microbiology of pathogens involved, to analyze survivorship free from infection in these patients. METHODS: The institutional prospectively collected database was reviewed to enroll patients with minimum 2 years follow-up. Patients who underwent two-stage procedure for septic arthritis were excluded, as were patients who had spacer fracture or dislocation. RESULTS: A total of 34 patients (41 procedures) were included. Mean age was 65.0 ± 12.8 years. Mean follow-up was 53.4 ± 24.8 months. Mean number of previous procedures was 3.6 ± 1.2. A total of 27 (79.4%) patients underwent final reimplantation. The most frequently isolated pathogen in spacer exchange was Staphylococcus epidermidis (10 cases, 28.6%). Polymicrobial cultures were obtained from 9 (25.71%) patients, 10 (28.6%) presented culture-negative infections. A total of 11 (32.4%) resistant pathogens were isolated, and 16 (47.0%) difficult to treat pathogens were detected. Eradication rate was 78.8%. Overall survivorship of implants after final reimplantation was 72.8% at 51.8 months. CONCLUSION: Surgeons should be aware that subjects necessitating spacer exchange often present multiple comorbidities, previous staged revision failures, soft-tissue impairment and difficult to treat infection. In these patients, spacer exchange provides good clinical results and infection eradication, preventing arthrodesis or amputation.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Artroplastia do Joelho , Infecções Relacionadas à Prótese , Humanos , Pessoa de Meia-Idade , Idoso , Artroplastia do Joelho/métodos , Infecção Persistente , Infecções Relacionadas à Prótese/cirurgia , Artroplastia de Quadril/métodos , Artrite Infecciosa/cirurgia , Reoperação/métodos , Estudos Retrospectivos , Antibacterianos/uso terapêutico , Resultado do Tratamento
8.
Biol Proced Online ; 24(1): 17, 2022 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-36396988

RESUMO

BACKGROUND: Phenotyping sputum-resident leukocytes and evaluating their functional status are essential analyses for exploring the cellular basis of pathological processes in the lungs, and flow cytometry is widely recognized as the gold-standard technique to address them. However, sputum-resident leukocytes are found in respiratory samples which need to be liquefied prior to cytometric analysis. Traditional liquefying procedures involve the use of a reducing agent such as dithiothreitol (DTT) in temperature-controlled conditions, which does not homogenize respiratory samples efficiently and impairs cell viability and functionality. METHODS: Here we propose an enzymatic method that rapidly liquefies samples by means of generating O2 bubbles with endogenous catalase. Sputum specimens from patients with suspected pulmonary infection were treated with DTT, the enzymatic method or PBS. We used turbidimetry to compare the liquefaction degree and cell counts were determined using a hemocytometer. Finally, we conducted a comparative flow cytometry study for evaluating frequencies of sputum-resident neutrophils, eosinophils and lymphocytes and their activation status after liquefaction. RESULTS: Enzymatically treated samples were better liquefied than those treated with DTT or PBS, which resulted in a more accurate cytometric analysis. Frequencies of all cell subsets analyzed within liquefied samples were comparable between liquefaction methods. However, the gentle cell handling rendered by the enzymatic method improves cell viability and retains in vivo functional characteristics of sputum-resident leukocytes (with regard to HLA-DR, CD63 and CD11b expression). CONCLUSION: In conclusion, the proposed enzymatic liquefaction method improves the cytometric analysis of respiratory samples and leaves the cells widely untouched for properly addressing functional analysis of lung leukocytes.

9.
Sens Actuators B Chem ; 373: 132638, 2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36124254

RESUMO

Stratifying patients according to disease severity has been a major hurdle during the COVID-19 pandemic. This usually requires evaluating the levels of several biomarkers, which may be cumbersome when rapid decisions are required. In this manuscript we show that a single nanoparticle aggregation test can be used to distinguish patients that require intensive care from those that have already been discharged from the intensive care unit (ICU). It consists of diluting a platelet-free plasma sample and then adding gold nanoparticles. The nanoparticles aggregate to a larger extent when the samples are obtained from a patient in the ICU. This changes the color of the colloidal suspension, which can be evaluated by measuring the pixel intensity of a photograph. Although the exact factor or combination of factors behind the different aggregation behavior is unknown, control experiments demonstrate that the presence of proteins in the samples is crucial for the test to work. Principal component analysis demonstrates that the test result is highly correlated to biomarkers of prognosis and inflammation that are commonly used to evaluate the severity of COVID-19 patients. The results shown here pave the way to develop nanoparticle aggregation assays that classify COVID-19 patients according to disease severity, which could be useful to de-escalate care safely and make a better use of hospital resources.

10.
Anal Chem ; 94(26): 9442-9449, 2022 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-35748103

RESUMO

Infections caused by bacteria that produce ß-lactamases (BLs) are a major problem in hospital settings. The phenotypic detection of these bacterial strains requires culturing samples prior to analysis. This procedure may take up to 72 h, and therefore it cannot be used to guide the administration of the first antibiotic regimen. Here, we propose a multisensor for identifying pathogens bearing different types of ß-lactamases above the infectious dose threshold within 90 min that does not require culturing samples. Instead, bacterial cells are preconcentrated in the cellulose scaffold of a paper-based multisensor. Then, 12 assays are performed in parallel to identify whether the pathogens produce carbapenemases and/or cephalosporinases, including metallo-ß-lactamases, extended-spectrum ß-lactamases (ESBLs), and AmpC enzymes. The multisensor generates an array of colored spots that can be quantified with image processing software and whose interpretation leads to the detection of the different enzymes depending on their specificity toward the hydrolysis of certain antibiotics, and/or their pattern of inhibition or cofactor activation. The test was validated for the diagnosis of urinary tract infections. The inexpensive paper platform along with the uncomplicated colorimetric readout makes the proposed prototypes promising for developing fully automated platforms for streamlined clinical diagnosis.


Assuntos
Cefalosporinase , Colorimetria , Antibacterianos/farmacologia , Bactérias , Proteínas de Bactérias , Testes de Sensibilidade Microbiana , beta-Lactamases/análise
11.
Sensors (Basel) ; 22(5)2022 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-35271026

RESUMO

Measuring the colorimetric signals produced by the biospecific accumulation of colorimetric probes and recording the results is a key feature for next-generation paper-based rapid tests. Manual processing of these tests is time-consuming and prone to a loss of accuracy when interpreting faint and patchy signals. Proprietary, closed-source readers and software companies offering automated smartphone-based assay readings have both been criticized for interoperability issues. Here, we introduce a minimal reader prototype composed of open-source hardware and open-source software that has the benefits of automatic assay quantification while avoiding the interoperability issues associated with closed-source readers. An image-processing algorithm was developed to automate the selection of an optimal region of interest and measure the average pixel intensity. When used to quantify signals produced by lateral flow immunoassays for detecting antibodies against SARS-CoV-2, results obtained with the proposed algorithm were comparable to those obtained with a manual method but with the advantage of improving the precision and accuracy when quantifying small spots or faint and patchy signals.


Assuntos
Técnicas Biossensoriais , COVID-19 , COVID-19/diagnóstico , Colorimetria/métodos , Humanos , Imunoensaio/métodos , SARS-CoV-2
12.
Arch Orthop Trauma Surg ; 142(11): 3437-3448, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34633511

RESUMO

BACKGROUND: Total knee arthroplasty is a reliable procedure able to reduce pain and disability in patients suffering from osteoarthritis. However, a considerable percentage of patients still experiences unsatisfactory results. Medial pivot total knee arthroplasty has been introduced in the clinical practice to overcome problems related with classic design implants and better mimic native knee kinematics. The aim of this study was to analyze survivorship and clinical and radiographic outcomes of medial pivot implants. METHODS: A systematic research was conducted in eight different databases. Thirty-four studies met the inclusion criteria and were included in the analysis. Data on objective and patients-reported outcomes, radiographic alignment, and survivorship were collected and analyzed. Revision rate was expressed as revision per 100 components years. RESULT: A total of 3377 procedures were included. Mean follow-up was 85.7 months (range, 12-182). The revision per 100 components years was 0.19, which corresponds to a revision rate of 1.9% after 10 years. Mean post-operative range of motion was 117.3 ± 0.4°. Mean clinical and functional Knee Society Score were, respectively, 85.9 ± 1.1 and 84.7 ± 3.5 at final follow-up. Post-operative femorotibial alignment was 177.1 ± 0.5°. Alfa and beta angles were 95.7 ± 0.1° and 89.2 ± 0.1°, respectively. Gamma and delta angles were 2.3 ± 0.6° and 86.7 ± 0.4°. CONCLUSION: Medial pivoting implants provided excellent survivorship and low revision rate, as well as good-to-excellent results in term of objective and patient-reported clinical outcomes, and reliable correction of radiographic parameters. More high-quality studies with long-term follow-up are needed to clarify the role of medial pivoting implants.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/métodos , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Amplitude de Movimento Articular , Estudos Retrospectivos , Sobrevivência
13.
Neuron ; 110(4): 627-643.e9, 2022 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-34921780

RESUMO

Although many neuronal membrane proteins undergo proteolytic cleavage, little is known about the biological significance of neuronal ectodomain shedding (ES). Here, we show that the neuronal sheddome is detectable in human cerebrospinal fluid (hCSF) and is enriched in neurodevelopmental disorder (NDD) risk factors. Among shed synaptic proteins is the ectodomain of CNTNAP2 (CNTNAP2-ecto), a prominent NDD risk factor. CNTNAP2 undergoes activity-dependent ES via MMP9 (matrix metalloprotease 9), and CNTNAP2-ecto levels are reduced in the hCSF of individuals with autism spectrum disorder. Using mass spectrometry, we identified the plasma membrane Ca2+ ATPase (PMCA) extrusion pumps as novel CNTNAP2-ecto binding partners. CNTNAP2-ecto enhances the activity of PMCA2 and regulates neuronal network dynamics in a PMCA2-dependent manner. Our data underscore the promise of sheddome analysis in discovering neurobiological mechanisms, provide insight into the biology of ES and its relationship with the CSF, and reveal a mechanism of regulation of Ca2+ homeostasis and neuronal network synchrony by a shed ectodomain.


Assuntos
Transtorno do Espectro Autista , Proteínas de Membrana , Proteínas do Tecido Nervoso , ATPases Transportadoras de Cálcio da Membrana Plasmática , Transtorno do Espectro Autista/líquido cefalorraquidiano , Transtorno do Espectro Autista/genética , Transtorno do Espectro Autista/metabolismo , Membrana Celular/metabolismo , Homeostase , Humanos , Proteínas de Membrana/metabolismo , Proteínas do Tecido Nervoso/metabolismo , Neurônios/metabolismo , ATPases Transportadoras de Cálcio da Membrana Plasmática/líquido cefalorraquidiano , ATPases Transportadoras de Cálcio da Membrana Plasmática/genética , ATPases Transportadoras de Cálcio da Membrana Plasmática/metabolismo , Transdução de Sinais
14.
ACS Sens ; 6(12): 4443-4450, 2021 12 24.
Artigo em Inglês | MEDLINE | ID: mdl-34793672

RESUMO

Hyperdegranulation of neutrophilic granulocytes is a common finding in sepsis that directly contributes to the heightened immune response leading to organ dysfunction. Currently, cell degranulation is detected by flow cytometry, which requires large infrastructure that is not always available at the point of care. Here, we propose a plasmonic assay for detecting the degranulation status of septic cells colorimetrically. It is based on triggering the aggregation of gold nanoparticles with cationic granule proteins. Cells from septic patients contain fewer granules and therefore release less cationic proteins than healthy cells. This results in red-colored assays than can be easily detected by eye. The assay can selectively detect cationic granule proteins even in the presence of an excess of unrelated proteins, which is key to detect degranulation with high specificity. Coupling this signal generation mechanism with a magnetic purification step enabled the identification of septic cells with the same performance as flow cytometry. This makes the proposed method a promising alternative for diagnosing sepsis in decentralized healthcare schemes.


Assuntos
Nanopartículas Metálicas , Sepse , Bioensaio , Colorimetria , Ouro , Humanos , Sepse/diagnóstico
15.
Analyst ; 146(21): 6537-6546, 2021 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-34581315

RESUMO

Lung IL-6 is a promising biomarker for predicting respiratory failure during pulmonary infections. This biomarker is found in respiratory samples which need to be liquefied prior to analysis. Traditional liquefying methods use reducing agents such as dithiothreitol (DTT). However, DTT impairs immunodetection and does not liquefy highly viscous samples. We propose an enzymatic method that liquefies samples by means of generating O2 bubbles with endogenous catalase. Low respiratory tract specimens from 48 mechanically ventilated patients (38 with SARS-CoV-2 infection) were treated with DTT or with the enzymatic method. We used turbidimetry to compare the liquefaction degree and IL-6 was quantified with ELISA. Finally, we used AUC-ROC, time-to-event and principal component analysis to evaluate the association between respiratory compromise or local inflammation and IL-6 determined with both methods. Enzymatically treated samples were better liquefied than those reduced by DTT, which resulted in higher ELISA signals. Lung IL-6 levels obtained with the enzymatic procedure were negatively correlated with the oxygenation index (PaO2/FiO2) and the time of mechanical ventilation. The proposed enzymatic liquefaction method improves the sensitivity for lung IL-6 detection in respiratory samples, which increases its predictive power as a biomarker for evaluating respiratory compliance.


Assuntos
COVID-19 , Interleucina-6 , Humanos , Pulmão , Respiração Artificial , SARS-CoV-2
16.
Sens Actuators B Chem ; 345: 130347, 2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34188360

RESUMO

Detecting SARS-CoV-2 antigens in respiratory tract samples has become a widespread method for screening new SARS-CoV-2 infections. This requires a nasopharyngeal swab performed by a trained healthcare worker, which puts strain on saturated healthcare services. In this manuscript we describe a new approach for non-invasive COVID-19 diagnosis. It consists of using mobile biosensors for detecting viral antigens trapped in surgical face masks worn by patients. The biosensors are made of filter paper containing a nanoparticle reservoir. The nanoparticles transfer from the biosensor to the mask on contact, where they generate colorimetric signals that are quantified with a smartphone app. Sample collection requires wearing a surgical mask for 30 min, and the total assay time is shorter than 10 min. When tested in a cohort of 27 patients with mild or no symptoms, an area under the receiving operating curve (AUROC) of 0.99 was obtained (96.2 % sensitivity and 100 % specificity). Serial measurements revealed a high sensitivity and specificity when masks were worn up to 6 days after diagnosis. Surgical face masks are inexpensive and widely available, which makes this approach easy to implement anywhere. The excellent sensitivity, even when tested with asymptomatic patient samples, along with the mobile detection scheme and non-invasive sampling procedure, makes this biosensor design ideal for mass screening.

17.
Int Orthop ; 45(7): 1683-1691, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33774699

RESUMO

PURPOSE: Septic arthritis of the native joint is challenging for orthopedic surgeons because it may lead to wide bone defects and severe impairment of joint function. This study aimed to analyze clinical functional outcomes, the rate of infection eradication, and survival of implants of patients who underwent two-stage arthroplasty for septic arthritis of the hip and knee. METHODS: A retrospective single-centre analysis was conducted of patients treated for septic arthritis of the hip and knee joints through a two-stage surgery between 2012 and 2015. Clinical and radiological records were gathered from the prospectively collected Institutional Arthroplasty Registry. Patients' pre-operative Harris hip scores and Knee Society scores were compared with those obtained at the latest follow-up. Kaplan-Meier curves were generated to assess survival of implants. RESULTS: Forty-seven patients were included. The mean follow-up was 85.2 ± 15.4 months. The Harris hip score improved from 39.4 ± 9.9 to 84.5 ± 10.8 points (p < 0.001). The Knee Society score improved from 40.7 ± 8.4 to 86.0 ± 7.8 points (p < 0.001). Knee Society score-function increased from 25.7 ± 14.2 to 85.4 ± 23.4 points (p < 0.001). The infection eradication rates were 92.0% and 90.9% in patients who underwent hip and knee operation, respectively (p = 0.891). Overall survivorship of implants after the second stage was 93.6%. CONCLUSIONS: Two-stage arthroplasty provides good to excellent clinical outcomes in cases of active septic arthritis of the hip and the knee, high rates of infection control, and implant survival.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Artroplastia do Joelho , Artrite Infecciosa/epidemiologia , Artrite Infecciosa/cirurgia , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Seguimentos , Humanos , Reoperação , Estudos Retrospectivos , Sobrevivência
18.
Anal Chem ; 93(12): 5259-5266, 2021 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-33733739

RESUMO

Lung-secreted IgG and IgM antibodies are valuable biomarkers for monitoring the local immune response against respiratory infections. These biomarkers are found in lower airway secretions that need to be liquefied prior to analysis. Traditional methods for sample liquefaction rely on reducing disulfide bonds, which may damage the structure of the biomarkers and hamper their immunodetection. Here, we propose an alternative enzymatic method that uses O2 bubbles generated by endogenous catalase enzymes in order to liquefy respiratory samples. The proposed method is more efficient for liquefying medium- and high-viscosity samples and does not fragment the antibodies. This prevents damage to antigen recognition domains and recognition sites for secondary antibodies that can decrease the signal of immunodetection techniques. The suitability of the enzymatic method for detecting antibodies in respiratory samples is demonstrated by detecting anti-SARS-CoV-2 IgG and IgM to viral N-protein with gold standard ELISA in bronchial aspirate specimens from a multicenter cohort of 44 COVID-19 patients. The enzymatic detection sharply increases the sensitivity toward IgG and IgM detection compared to the traditional approach based on liquefying samples with dithiothreitol. This improved performance could reveal new mechanisms of the early local immune response against respiratory infections that may have gone unnoticed with current sample treatment methods.


Assuntos
Anticorpos Antivirais/imunologia , COVID-19/imunologia , Imunoglobulina G/imunologia , Imunoglobulina M/imunologia , Pulmão/imunologia , SARS-CoV-2/imunologia , Ensaio de Imunoadsorção Enzimática , Humanos , Limite de Detecção
19.
Sens Actuators B Chem ; 330: 129333, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33519090

RESUMO

Decentralizing COVID-19 care reduces contagions and affords a better use of hospital resources. We introduce biosensors aimed at detecting severe cases of COVID-19 in decentralized healthcare settings. They consist of a paper immunosensor interfaced with a smartphone. The immunosensors have been designed to generate intense colorimetric signals when the sample contains ultralow concentrations of IL-6, which has been proposed as a prognosis biomarker of COVID-19. This is achieved by combining a paper-based signal amplification mechanism with polymer-filled reservoirs for dispensing antibody-decorated nanoparticles and a bespoken app for color quantification. With this design we achieved a low limit of detection (LOD) of 10-3 pg mL-1 and semi-quantitative measurements in a wide dynamic range between 10-3 and 102 pg mL-1 in PBS. The assay time is under 10 min. The low LOD allowed us to dilute blood samples and detect IL-6 with an LOD of 1.3 pg mL-1 and a dynamic range up to 102 pg mL-1. Following this protocol, we were able to stratify COVID-19 patients according to different blood levels of IL-6. We also report on the detection of IL-6 in respiratory samples (bronchial aspirate, BAS) from COVID-19 patients. The test could be easily adapted to detect other cytokines such as TNF-α and IL-8 by changing the antibodies decorating the nanoparticles accordingly. The ability of detecting cytokines in blood and respiratory samples paves the way for monitoring local inflammation in the lungs as well as systemic inflammation levels in the body.

20.
Analyst ; 145(24): 7916-7921, 2021 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-33020772

RESUMO

Urinary tract infections (UTI) have a high prevalence and can yield poor patient outcomes if they progress to urosepsis. Here we introduce mobile origami biosensors that detect UTIs caused by E. coli at the bedside in less than 7 minutes. The origami biosensors are made of a single piece of paper that contains antibody-decorated nanoparticles. When the urine sample contains E. coli, the biosensors generate colored spots on the paper strip. These are then quantified with a mobile app that calculates the pixel intensity in real time. The tests are highly specific and do not cross-react with other common uropathogens. Furthermore, the biosensors only yielded one false negative result when queried with a panel containing 57 urine samples from patients, which demonstrates that they have excellent sensitivity and specificity. This, along with the rapid assay time and smartphone-based detection, makes them useful for aiding in the diagnosis of UTIs at the point of care.


Assuntos
Técnicas Biossensoriais , Infecções por Escherichia coli , Infecções Urinárias , Escherichia coli , Infecções por Escherichia coli/diagnóstico , Humanos , Imunoensaio , Infecções Urinárias/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA