Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Radiat Oncol ; 16(1): 81, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33933118

RESUMO

INTRODUCTION: The current phase III EORTC 1420 Best-of trial (NCT02984410) compares the swallowing function after transoral surgery versus intensity modulated radiotherapy (RT) in patients with early-stage carcinoma of the oropharynx, supraglottis and hypopharynx. We report the analysis of the Benchmark Case (BC) procedures before patient recruitment with special attention to dysphagia/aspiration related structures (DARS). MATERIALS AND METHODS: Submitted RT volumes and plans from participating centers were analyzed and compared against the gold-standard expert delineations and dose distributions. Descriptive analysis of protocol deviations was conducted. Mean Sorensen-Dice similarity index (mDSI) and Hausdorff distance (mHD) were applied to evaluate the inter-observer variability (IOV). RESULTS: 65% (23/35) of the institutions needed more than one submission to achieve Quality assurance (RTQA) clearance. OAR volume delineations were the cause for rejection in 53% (40/76) of cases. IOV could be improved in 5 out of 12 OARs by more than 10 mm after resubmission (mHD). Despite this, final IOV for critical OARs in delineation remained significant among DARS by choosing an aleatory threshold of 0.7 (mDSI) and 15 mm (mHD). CONCLUSIONS: This is to our knowledge the largest BC analysis among Head and neck RTQA programs performed in the framework of a prospective trial. Benchmarking identified non-common OARs and target delineations errors as the main source of deviations and IOV could be reduced in a significant number of cases after this process. Due to the substantial resources involved with benchmarking, future benchmark analyses should assess fully the impact on patients' clinical outcome.


Assuntos
Benchmarking/métodos , Neoplasias Hipofaríngeas/radioterapia , Órgãos em Risco/efeitos da radiação , Neoplasias Orofaríngeas/radioterapia , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Supraglotite/radioterapia , Ensaios Clínicos Fase III como Assunto , Humanos , Neoplasias Hipofaríngeas/patologia , Variações Dependentes do Observador , Neoplasias Orofaríngeas/patologia , Prognóstico , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Supraglotite/patologia
2.
Radiother Oncol ; 161: 35-39, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33872641

RESUMO

PURPOSE: To externally validate previously published Normal Tissue Complication Probability (NTCP) models developed by separate teams for grade 3 oral mucositis (g3OM). MATERIALS AND METHODS: Two models were validated: a logistic model, based on 144 head and neck cancer (HNC) patients receiving induction chemotherapy followed by chemo-IMRT; a multivariable logistic model for prediction of g3OM for 253 patients receiving radical treatment for the head and neck squamous cell carcinoma (HNSCC). The EORTC HNCG-ROG 1219 DAHANCA trial dataset, consisting of 169 patients was used as the validation cohort. This cohort was treated with accelerated fractionated chemo-IMRT, with/without the hypoxic radiosensitizer Nimorazole for HNSCC. External validity was assessed using the scaled Brier score. Calibration was assessed in terms of calibration curves as well as measures of mean and weak calibration. Hosmer-Lemeshow was used for goodness-of-fit test. Discrimination was calculated using the area under the receiver operating curve (AUC-ROC). RESULTS: The prevalence of g3OM in the validation cohort (35.5%) was similar to that of two development cohorts, i.e. 38.7% and 31.9% for Bhide logistic and Otter multivariable logistic models respectively. The scaled Brier scores showed good overall model performance. Perfect calibration was observed in the prevalence range of 20% to 40%. AUC-ROC was acceptable in external validation (0.67). The Hosmer-Lemeshow test showed good agreement between predicted and observed outcomes for two models. CONCLUSION: The NTCP models were validated and lead to valid predictions in a wide range of diverse treatment techniques and patient characteristics, also when Nimorazole is added as hypoxic radiosensitizer.


Assuntos
Neoplasias de Cabeça e Pescoço , Estomatite , Estudos de Coortes , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Probabilidade , Carcinoma de Células Escamosas de Cabeça e Pescoço/radioterapia
3.
Phys Med Biol ; 59(19): 5849-71, 2014 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-25207724

RESUMO

In this work, we present experimental results of a prompt gamma camera for real-time proton beam range verification. The detection system features a pixelated Cerium doped lutetium based scintillation crystal, coupled to Silicon PhotoMultiplier arrays, read out by dedicated electronics. The prompt gamma camera uses a knife-edge slit collimator to produce a 1D projection of the beam path in the target on the scintillation detector. We designed the detector to provide high counting statistics and high photo-detection efficiency for prompt gamma rays of several MeV. The slit design favours the counting statistics and could be advantageous in terms of simplicity, reduced cost and limited footprint. We present the description of the realized gamma camera, as well as the results of the characterization of the camera itself in terms of imaging performance. We also present the results of experiments in which a polymethyl methacrylate phantom was irradiated with proton pencil beams in a proton therapy center. A tungsten slit collimator was used and prompt gamma rays were acquired in the 3-6 MeV energy range. The acquisitions were performed with the beam operated at 100 MeV, 160 MeV and 230 MeV, with beam currents at the nozzle exit of several nA. Measured prompt gamma profiles are consistent with the simulations and we reached a precision (2σ) in shift retrieval of 4 mm with 0.5 × 10(8), 1.4 × 10(8) and 3.4 × 10(8) protons at 100, 160 and 230 MeV, respectively. We conclude that the acquisition of prompt gamma profiles for in vivo range verification of proton beam with the developed gamma camera and a slit collimator is feasible in clinical conditions. The compact design of the camera allows its integration in a proton therapy treatment room and further studies will be undertaken to validate the use of this detection system during treatment of real patients.


Assuntos
Diagnóstico por Imagem , Raios gama , Imagens de Fantasmas , Terapia com Prótons/métodos , Radiometria/instrumentação , Radioterapia Assistida por Computador/instrumentação , Contagem de Cintilação/métodos , Câmaras gama , Humanos , Contagem de Cintilação/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA