Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 45(4): 1603-1613, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29389017

RESUMO

PURPOSE: Application of advanced imaging techniques, such as PET and x ray CT, can potentially improve detection of breast cancer. Unfortunately, both modalities have challenges in the detection of some lesions. The combination of the two techniques, however, could potentially lead to an overall improvement in diagnostic breast imaging. The purpose of this investigation is to test the basic performance of a new dedicated breast-PET/CT. METHODS: The PET component consists of a rotating pair of detectors. Its performance was evaluated using the NEMA NU4-2008 protocols. The CT component utilizes a pulsed x ray source and flat panel detector mounted on the same gantry as the PET scanner. Its performance was assessed using specialized phantoms. The radiation dose to a breast during CT imaging was explored by the measurement of free-in-air kerma and air kerma measured at the center of a 16 cm-diameter PMMA cylinder. Finally, the combined capabilities of the system were demonstrated by imaging of a micro-hot-rod phantom. RESULTS: Overall, performance of the PET component is comparable to many pre-clinical and other dedicated breast-PET scanners. Its spatial resolution is 2.2 mm, 5 mm from the center of the scanner using images created with the single-sliced-filtered-backprojection algorithm. Peak NECR is 24.6 kcps; peak sensitivity is 1.36%; the scatter fraction is 27%. Spatial resolution of the CT scanner is 1.1 lp/mm at 10% MTF. The free-in-air kerma is 2.33 mGy, while the PMMA-air kerma is 1.24 mGy. Finally, combined imaging of a micro-hot-rod phantom illustrated the potential utility of the dual-modality images produced by the system. CONCLUSION: The basic performance characteristics of a new dedicated breast-PET/CT scanner are good, demonstrating that its performance is similar to current dedicated PET and CT scanners. The potential value of this system is the capability to produce combined duality-modality images that could improve detection of breast disease. The next stage in development of this system is testing with more advanced phantoms and human subjects.


Assuntos
Mama/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Desenho de Equipamento , Imagens de Fantasmas , Reprodutibilidade dos Testes
2.
Nucl Instrum Methods Phys Res A ; 788: 86-94, 2015 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-33173251

RESUMO

Conventional PET systems can be augmented with additional detectors placed in close proximity of the region of interest. We developed a high resolution PET insert module to evaluate the added benefit of such a combination. The insert module consists of two back-to-back 1 mm thick silicon sensors, each segmented into 1040 1 mm2 pads arranged in a 40 by 26 array. A set of 16 VATAGP7.1 ASICs and a custom assembled data acquisition board were used to read out the signal from the insert module. Data were acquired in slice (2D) geometry with a Jaszczak phantom (rod diameters of 1.2-4.8 mm) filled with 18F-FDG and the images were reconstructed with ML-EM method. Both data with full and limited angular coverage from the insert module were considered and three types of coincidence events were combined. The ratio of high-resolution data that substantially improves quality of the reconstructed image for the region near the surface of the insert module was estimated to be about 4%. Results from our previous studies suggest that such ratio could be achieved at a moderate technological expense by using an equivalent of two insert modules (an effective sensor thickness of 4 mm).

3.
Nucl Instrum Methods Phys Res A ; 570(3): 543-555, 2007 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-18084629

RESUMO

A very high resolution small animal positron emission tomograph (PET) which can achieve sub-millimeter spatial resolution is being developed using silicon pad detectors. The prototype PET for a single slice instrument consists of two 1 mm thick silicon pad detectors, each containing a 32 x 16 array of 1.4 mm x 1.4 mm pads read out with four VATAGP3 chips which have 128 channels low-noise self triggering ASIC in each chip, coincidence units, a source turntable and tungsten slice collimator. The silicon detectors were located edgewise on opposite sides of a 4 cm field-of-view to maximize efficiency. Energy resolution is dominated by electronic noise, which is 0.98% (1.38 keV) FWHM at 140.5 keV. Coincidence timing resolution is 82.1 ns FWHM and coincidence efficiency was measured to be 1.04 x 10(-3) % from two silicon detectors with annihilation photons of (18)F source Image data were acquired and reconstructed using conventional 2-D filtered-back projection (FBP) and a maximum likelihood expectation maximization (ML-EM) method. Image resolution of approximately 1.45 mm FWHM is obtained from 1-D profile of 1.1 mm diameter (18)F line source image. Even better resolution can be obtained with smaller detector element sizes. While many challenges remain in scaling up the instrument to useful efficiency including densely packed detectors and significantly improved timing resolution, performance of the test setup in terms of easily achieving submillimeter resolution is compelling.

4.
Phys Med Biol ; 52(15): 4653-77, 2007 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-17634656

RESUMO

A small animal positron emission tomography (PET) instrument using a high-resolution solid-state detector insert in a conventional PET system was investigated for its potential to achieve sub-millimeter spatial resolution for mouse imaging. Monte Carlo simulations were used to estimate the effect of detector configurations (thickness, length and radius) on sensitivity. From this initial study, a PET system having an inner cylindrical silicon detector (4 cm ID, 4 cm length and 1.6 cm thickness composed of 16 layers of 300 microm x 300 microm x 1 mm pads), for scattering, surrounded by an outer cylindrical BGO scintillation detector (17.6 cm ID, 16 cm length and 2 cm thickness segmented into 3 mm x 3 mm x 20 mm crystals), for capture was evaluated in detail. In order to evaluate spatial resolution, sensitivity and image quality of the PET system, 2D images of multiple point and cylinder sources were reconstructed with the simulation data including blurring from positron range and annihilation photon acollinearity using filtered backprojection (FBP). Simulation results for (18)F demonstrate 340 microm FWHM at the center of the field of view with 1.0% sensitivity from the coincidence of single scattering events in both silicon detectors and 1.0 mm FWHM with 9.0% sensitivity from the coincidence of single scattering in the silicon and full energy absorption of the second photon in the BGO detector.


Assuntos
Desenho Assistido por Computador , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/veterinária , Radiometria/instrumentação , Silício/efeitos da radiação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transdutores
5.
Phys Med Biol ; 52(10): 2807-26, 2007 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-17473353

RESUMO

A very high resolution positron emission tomography (PET) scanner for small animal imaging based on the idea of inserting a ring of high-granularity solid-state detectors into a conventional PET scanner is under investigation. A particularly interesting configuration of this concept, which takes the form of a degenerate Compton camera, is shown capable of providing sub-millimeter resolution with good sensitivity. We present a Compton PET system and estimate its performance using a proof-of-concept prototype. A prototype single-slice imaging instrument was constructed with two silicon detectors 1 mm thick, each having 512 1.4 mm x 1.4 mm pads arranged in a 32 x 16 array. The silicon detectors were located edgewise on opposite sides and flanked by two non-position sensitive BGO detectors. The scanner performance was measured for its sensitivity, energy, timing, spatial resolution and resolution uniformity. Using the experimental scanner, energy resolution for the silicon detectors is 1%. However, system energy resolution is dominated by the 23% FWHM BGO resolution. Timing resolution for silicon is 82.1 ns FWHM due to time-walk in trigger devices. Using the scattered photons, time resolution between the BGO detectors is 19.4 ns FWHM. Image resolution of 980 microm FWHM at the center of the field-of-view (FOV) is obtained from a 1D profile of a 0.254 mm diameter (18)F line source image reconstructed using the conventional 2D filtered back-projection (FBP). The 0.4 mm gap between two line sources is resolved in the image reconstructed with both FBP and the maximum likelihood expectation maximization (ML-EM) algorithm. The experimental instrument demonstrates sub-millimeter resolution. A prototype having sensitivity high enough for initial small animal images can be used for in vivo studies of small animal models of metabolism, molecular mechanism and the development of new radiotracers.


Assuntos
Tomografia por Emissão de Pósitrons/instrumentação , Silício/química , Animais , Desenho de Equipamento
6.
Phys Med Biol ; 49(4): 617-38, 2004 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-15005169

RESUMO

In this paper, we present a novel approach to scintimammography that is based on the Compton camera principle. We analyse the performance of our scheme using Monte Carlo simulations. In particular, we evaluate the detection efficiency, spatial resolution and lesion visibility of the system at several gamma photon energies. The simulation results show that the proposed technique achieves an absolute detection efficiency of 0.03 and a full width at half maximum resolution of 3.8 mm at 141 keV photon energy for point sources 2.5 cm deep in a 5 cm thick breast phantom using 5 mm thick silicon detectors. Furthermore, our approach shows good performance in lesion detection, especially at high gamma photon energies, where mechanically collimated systems perform poorly due to severe septal penetration. With total collected counts of 1.35 million, equivalent to a 30 s acquisition time for an activity concentration level of 3.7 kBq ml(-1) (100 nCi cm(-3)) in normal breast tissue, and a tumour-to-background ratio of 8:1, our system can clearly reveal an 8 mm diameter tumour that is located 2.5 cm deep in a 500 ml breast phantom. We also present a simulation-based quantitative performance comparison between the proposed scintimammographic system and the compact collimated scintimammographic system in the task of lesion detection under a clinical imaging situation using a non-prewhitening matched filter observer model. Our comparison demonstrates that for the same imaging time, the two systems have a comparable performance in detecting an 8 mm tumour at 141 keV, with the proposed system performing marginally better. However, the proposed scintimammographic system clearly outperforms the compact collimated counterpart in the detection of a 5 mm tumour. We also investigate the contribution of scatter and direct radiation from adjacent organs. We find that the background contribution of liver to the right breast is 30% at 141 keV, which can be reduced to 4.8% with shielding.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Câmaras gama , Mamografia/métodos , Método de Monte Carlo , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Fótons , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA