Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Phys Rev Lett ; 132(13): 135101, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38613280

RESUMO

We report observations of nonlinear two-plasmon decay instabilities (TPDIs) of a high-power microwave beam, a process similar to half-harmonic generation in optics, during electron cyclotron resonance heating in a tokamak. TPDIs are found to occur regularly in the plasma edge due to wave trapping in density fluctuations for various confinement modes, and the frequencies of both observed daughter waves agree with modeling. Emissions from a cascade of subsequent decays, which indicate a generation of ion Bernstein waves, are correlated with fast-ion generation. This emphasizes the limitations of standard linear microwave propagation models and possibly paves the way for novel microwave applications in plasmas.

2.
Rev Sci Instrum ; 94(10)2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37801369

RESUMO

In this paper, a diagnostic for the measurement of the electron cyclotron emission (ECE) from non-thermal electrons in magnetically confined fusion plasmas is presented. The diagnostic employs a vertical viewing line of sight that allows us to directly infer the energy of the emitting electrons. Previous incarnations of this diagnostic on other machines have been limited by refraction, which can cause stray radiation to enter the line of sight, polluting the signal. By tuning the toroidal magnetic field on the Tokamak à Configuration Variable, TCV, and by carefully selecting the range of frequencies that are used to measure the ECE spectrum, refraction can be mitigated and background radiation power reduced to below the noise power of the instrumentation. A novel technique for calibrating the diagnostic based on plasma measurements and modeling has been developed. The paper will describe the Vertical ECE (V-ECE) diagnostic on TCV, the calibration method, and the first results from the measurements.

3.
Acta Ortop Mex ; 37(1): 2-8, 2023.
Artigo em Espanhol | MEDLINE | ID: mdl-37857390

RESUMO

INTRODUCTION: in patients with anterior glenohumeral (GH) instability together with an off-track or engaging Hill-Sachs (HS) defect, Bankart-remplissage (B-R) surgery reduces the recurrence rate when compared to Bankart (B) surgery alone. There is controversy regarding whether the recurrence rate also decreases in patients with on-track or non-engaging Hill-Sachs defects. OBJECTIVE: to compare the recurrence rate and clinical evolution of patients with anterior glenohumeral instability with 'on-track' Hill-Sachs defect treated with either B or B-R surgery. MATERIAL AND METHODS: non-randomized, retrospective, single-center cohort study of patients with anterior glenohumeral instability and on-track Hill-Sachs defect, operated between January 2010 and December 2018. Patients operated with B versus B-R were compared. Recurrence, complications and re-operation were recorded. In addition, VAS, SSV, WOSI and qDASH scores were obtained and compared in both groups. RESULTS: of the 105 patients who met the inclusion criteria, 78 (74.3%) patients had a complete follow-up (52 B and 26 B-R, 4.3 years median follow-up). There was a higher recurrence rate in group B compared to B-R, with this difference not reaching statistical significance (17.3% vs 7.7%, p = 0.21). There were no significant differences in residual pain, feeling of instability, complications or VAS, qDASH, SSV or WOSI scores between both groups. In the subgroup analysis, patients who practiced contact sports and were operated with B showed higher recurrence rates (24.1% vs 0%, p = 0.08) and complications (41.4% vs 18.2%, p = 0.16) when compared to B + R, although these differences were not significant. CONCLUSION: there were no significant differences in recurrence rates and functional evolution between patients with anterior glenohumeral instability operated with B or B-R surgery. Comparative, prospective studies should be performed to establish definitive recommendations.


INTRODUCCIÓN: en pacientes con inestabilidad glenohumeral (GH) anterior con defecto de Hill-Sachs (HS) off-track o enganchante, Bankart-remplissage (B + R) reduce tasa de recurrencia en comparación a Bankart aislado (B). Hay controversia si tasa de recurrencia también disminuye en pacientes con defecto de HS on-track o no enganchantes. OBJETIVO: comparar la tasa de recurrencia y evolución clínica entre la cirugía de B versus B-R en pacientes operados por inestabilidad glenohumeral anterior con defecto de Hill-Sachs on-track. MATERIAL Y MÉTODOS: estudio de cohorte, no randomizado, retrospectivo y unicéntrico, en pacientes operados por inestabilidad glenohumeral anterior, entre Enero 2010 y Diciembre de 2018. Se incluyen sólo pacientes con defecto de Hill-Sachs on-track. Fueron comparados pacientes operados con cirugía de B versus B + R. Se consigna recurrencia, complicación, reoperación y sensación de inestabilidad. Además, se realizan y comparan puntajes de EVA, SSV, WOSI y qDASH. RESULTADOS: de los 105 pacientes que cumplieron criterios de inclusión, 78 (74.3%) realizaron seguimiento completo (52 B y 26 B + R, 4.3 años mediana de seguimiento). Hubo mayor tasa de recurrencia en grupo B en comparación a B + R, siendo esta diferencia no significativa (17.3% versus 7.7%, p = 0.21). No hubo diferencia significativa en dolor residual, sensación de inestabilidad residual, complicaciones o puntajes de escala EVA, qDASH, SSV ni WOSI. En análisis por subgrupo, pacientes con deportes de contacto, B tienen mayor tasa de recurrencia (24.1% versus 0%, p = 0.08) y complicaciones comparadas con B + R (41.4% versus 18.2%, p = 0.16), siendo estas diferencias no significativas. CONCLUSIÓN: no hubo diferencias significativas en tasa de recurrencia y evolución funcional entre cirugía de Bankart aislado o Bankart-remplissage para inestabilidad glenohumeral anterior asociada a defecto de Hill-Sachs on-track. Estudios comparativos, prospectivos deben realizarse para establecer recomendaciones definitivas.


Assuntos
Lesões de Bankart , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Articulação do Ombro/cirurgia , Estudos de Coortes , Luxação do Ombro/cirurgia , Estudos Retrospectivos , Ombro , Estudos Prospectivos , Instabilidade Articular/cirurgia , Instabilidade Articular/etiologia , Artroscopia , Lesões de Bankart/cirurgia , Recidiva
8.
Rev Sci Instrum ; 90(12): 123501, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31893830

RESUMO

This article describes the realization of a novel approach to short pulse (∼1 ns) reflectometry (SPR) recently implemented in the tokamak configuration variable tokamak. Taking advantage of a fast arbitrary waveform generator and vector-network-analyzer extension modules, the design offers flexibility regarding pulse output frequency, duration, and repetition rate. Such flexibility allows the instrument to overcome traditional SPR spatial sampling limitations while reducing hardware complexity. In order to measure the group-delay of nanosecond-scale pulses, both traditional analog and novel digital sampling techniques have been explored. A group-delay range resolution of 17 ps (2.6 mm) in average over the V-band has been achieved with both timing techniques against a waveguide mirror featuring 10 dB power fluctuations. Direct pulse sampling during L-mode plasmas shows that reflected pulse widths increase only by 4% in average. However, pulse width dispersion does occur in L-mode plasmas and leads to an increase in the group-delay uncertainty up to 40 ps (6 mm). Raw histograms of group-delay data show interesting qualitative changes from the L mode to the H-mode. Frequency spectra of group-delay data allow the identification of macroscopic density fluctuations as well as edge quasicoherent modes during edge-localized mode-free H-modes. Finally, fast changes to the density profile have been measured with microsecond time resolution and subcentimeter spatial resolution in both O and X-mode polarizations.

9.
Rev Sci Instrum ; 89(8): 083503, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30184720

RESUMO

A variable configuration V-band heterodyne Doppler back-scattering diagnostic has been recently made operational in the tokamak à configuration variable. This article describes the hardware setup options, flexible quasi-optical launcher antenna, data-analysis techniques, and first data. The diagnostic uses a fast arbitrary waveform generator as the main oscillator and commercial vector network analyzer extension modules as the main mm-wave hardware. It allows sweepable single or multi-frequency operation. A flexible quasi-optical launcher antenna allows 3D poloidal (10°-58°) and toroidal (-180° to 180°) steering of the beam with 0.2° accuracy. A pair of fast HE11 miter-bend polarizers allow flexible coupling to either O or X mode and programmable polarization changes during the shot. These have been used to measure the magnetic-field pitch angle in the edge of the plasma by monitoring the backscattered signal power. Ray-tracing simulations reveal an available k⊥ range between 3 and 16 cm-1 with a resolution of 2-4 cm-1. Perpendicular rotation velocity estimates compare well against ExB plasma poloidal rotation estimates from charge exchange recombination spectroscopy.

10.
Rev Sci Instrum ; 87(11): 11E118, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910353

RESUMO

A tangential viewing phase contrast imaging system is being designed for the JT-60SA tokamak to investigate microturbulence. In order to obtain localized information on the turbulence, a spatial-filtering technique is applied, based on magnetic shearing. The tangential viewing geometry enhances the radial localization. The probing laser beam is injected tangentially and traverses the entire plasma region including both low and high field sides. The spatial resolution for an Internal Transport Barrier discharge is estimated at 30%-70% of the minor radius at k = 5 cm-1, which is the typical expected wave number of ion scale turbulence such as ion temperature gradient/trapped electron mode.

11.
Nat Commun ; 3: 624, 2012 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-22233634

RESUMO

Virtually collisionless magnetic mirror-trapped energetic ion populations often partially stabilize internally driven magnetohydrodynamic disturbances in the magnetosphere and in toroidal laboratory plasma devices such as the tokamak. This results in less frequent but dangerously enlarged plasma reorganization. Unique to the toroidal magnetic configuration are confined 'circulating' energetic particles that are not mirror trapped. Here we show that a newly discovered effect from hybrid kinetic-magnetohydrodynamic theory has been exploited in sophisticated phase space engineering techniques for controlling stability in the tokamak. These theoretical predictions have been confirmed, and the technique successfully applied in the Joint European Torus. Manipulation of auxiliary ion heating systems can create an asymmetry in the distribution of energetic circulating ions in the velocity orientated along magnetic field lines. We show the first experiments in which large sawtooth collapses have been controlled by this technique, and neoclassical tearing modes avoided, in high-performance reactor-relevant plasmas.

12.
G Chir ; 31(5): 233-5, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20615366

RESUMO

We report a case of acute relapsing pancreatitis associated with pancreas divisum, who underwent major papilla sphincterotomy after failed minor papilla cannulation. Long-term results were satisfactory. The possible explanations of the efficacy of major papilla endoscopic resection in this particular case are discussed.


Assuntos
Ampola Hepatopancreática/cirurgia , Pâncreas/anormalidades , Pancreatite/etiologia , Pancreatite/cirurgia , Esfinterotomia Endoscópica , Idoso , Colangiopancreatografia Retrógrada Endoscópica/métodos , Colangiopancreatografia por Ressonância Magnética/métodos , Feminino , Humanos , Ductos Pancreáticos/anormalidades , Pancreatite/diagnóstico , Recidiva , Stents , Resultado do Tratamento
13.
Phys Rev Lett ; 105(15): 155003, 2010 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-21230915

RESUMO

An edge-localized mode (ELM) H-mode regime, supported by electron cyclotron heating, has been successfully established in a "snowflake" (second-order null) divertor configuration for the first time in the TCV tokamak. This regime exhibits 2 to 3 times lower ELM frequency and 20%-30% increased normalized ELM energy (ΔWELM/Wp) compared to an identically shaped, conventional single-null diverted H mode. Enhanced stability of mid- to high-toroidal-mode-number ideal modes is consistent with the different snowflake ELM phenomenology. The capability of the snowflake to redistribute the edge power on the additional strike points has been confirmed experimentally.

14.
Endoscopy ; 41(5): 421-6, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19418396

RESUMO

BACKGROUND AND STUDY AIMS: Bleeding and perforation are major complications of endoscopic submucosal dissection (ESD) for early gastric cancer (EGC), but post-ESD stenosis represents a severe delayed complication that can result in clinical symptoms such as dysphagia and nausea. The aims of this study were to determine the risk factors and evaluate the clinical treatment for post-ESD stenosis. METHODS: A total of 2011 EGCs resected by ESD at our institution between 2000 and 2005 were reviewed retrospectively. Resection was defined as cardiac when any mucosal defect was located in the squamocolumnar junction, and as pyloric when any mucosal defect was located < 1 cm from the pylorus ring. Post-ESD stenosis was defined when a standard endoscope could not be passed through the stenosis. We examined the incidence of post-ESD stenosis, its relationship with relevant factors, and the clinical course of post-ESD stenosis patients. RESULTS: Post-ESD stenosis occurred with seven of 41 cardiac resections (17 %) and eight of 115 pyloric resections (7 %). Circumferential extent of the mucosal defect of > 3/4 and longitudinal extent > 5 cm were each significantly related to occurrence of post-ESD stenosis with both cardiac and pyloric resections. All 15 affected patients were successfully treated by endoscopic balloon dilation. CONCLUSIONS: A circumferential extent of the mucosal defect of > 3/4 or longitudinal extent of > 5 cm in length were both demonstrated to be risk factors for post-ESD stenosis, in both cardiac and pyloric resections, and endoscopic balloon dilation was shown to be effective in treating post-ESD stenosis.


Assuntos
Cárdia/cirurgia , Cateterismo/métodos , Mucosa Gástrica/cirurgia , Gastroscopia/métodos , Complicações Pós-Operatórias/terapia , Lesões Pré-Cancerosas/cirurgia , Antro Pilórico/cirurgia , Estenose Pilórica/terapia , Neoplasias Gástricas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Lesões Pré-Cancerosas/patologia , Estenose Pilórica/etiologia , Fatores de Risco , Neoplasias Gástricas/patologia , Adulto Jovem
15.
Phys Rev Lett ; 102(6): 065005, 2009 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-19257598

RESUMO

The sawtooth control mechanism in plasmas employing off-axis toroidally propagating ion cyclotron resonance waves in tokamaks is reinvestigated. The radial drift excursion of energetic passing ions distributed asymmetrically in the velocity parallel to the magnetic field determines stability when the rational q=1 surface resides within a narrow region centered about the shifted fundamental cyclotron resonance.

16.
Rev Sci Instrum ; 79(10): 10F501, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044646

RESUMO

Plasmas, both in the laboratory and in space, are often not in thermodynamic equilibrium, and the plasma electron distribution function is accordingly non-Maxwellian. Suprathermal electron tails can be generated by external drives, such as rf waves and electric fields, or internal ones, such as instabilities and magnetic reconnection. The variety and importance of the phenomena in which suprathermal electrons play a significant role explains an enduring interest in diagnostic techniques to investigate their properties and dynamics. X-ray bremsstrahlung emission has been studied in hot magnetized plasmas for well over two decades, flanked progressively by electron-cyclotron emission in geometries favoring the high-energy end of the distribution function (high-field-side, vertical, oblique emission), by electron-cyclotron absorption, by spectroscopic techniques, and at lower temperatures, by Langmuir probes and electrostatic analyzers. Continuous progress in detector technology and in measurement and analysis techniques, increasingly sophisticated layouts (multichannel and tomographic systems, imaging geometries), and highly controlled suprathermal generation methods (e.g., perturbative rf modulation) have all been brought to bear in recent years on an increasingly detailed, although far from complete, understanding of suprathermal electron dynamics.

17.
Rev Sci Instrum ; 79(10): 10F504, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044649

RESUMO

Electron cyclotron resonance heating and electron cyclotron current drive, disruptive events, and sawtooth activity are all known to produce suprathermal electrons in fusion devices, motivating increasingly detailed studies of the generation and dynamics of this suprathermal population. Measurements have been performed in the past years in the tokamak a configuration variable (TCV) tokamak using a single pinhole hard-x-ray (HXR) camera and electron-cyclotron-emission radiometers, leading, in particular, to the identification of the crucial role of spatial transport in the physics of ECCD. The observation of a poloidal asymmetry in the emitted suprathermal bremsstrahlung radiation motivates the design of a proposed new tomographic HXR spectrometer reported in this paper. The design, which is based on a compact modified Soller collimator concept, is being aided by simulations of tomographic reconstruction. Quantitative criteria have been developed to optimize the design for the greatly variable shapes and positions of TCV plasmas.

18.
Phys Rev Lett ; 94(10): 105002, 2005 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-15783491

RESUMO

Improved electron energy confinement in tokamak plasmas, related to internal transport barriers, has been linked to nonmonotonic current density profiles. This is difficult to prove experimentally since usually the current profiles evolve continuously and current injection generally requires significant input power. New experiments are presented, in which the inductive current is used to generate positive and negative current density perturbations in the plasma center, with negligible input power. These results demonstrate unambiguously for the first time that the electron confinement can be modified significantly solely by perturbing the current density profile.

19.
Phys Rev Lett ; 93(21): 215001, 2004 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-15601020

RESUMO

Clear evidence is reported for the first time of a rapid localized reduction of core electron energy diffusivity during the formation of an electron internal-transport barrier. The transition occurs rapidly (approximately = 3 ms), during a slow (approximately = 200 ms) self-inductive evolution of the magnetic shear. This crucial observation, and the correlation of the transition with the time and location of the magnetic shear reversal, lend support to models attributing the reduced transport to the local properties of a zero-shear region, in contrast to models predicting a gradual reduction due to a weak or negative shear.

20.
Phys Rev Lett ; 92(23): 235004, 2004 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-15245165

RESUMO

In a tokamak fusion reactor the energetic alpha particles will transiently stabilize the magnetohydrodynamic activity causing sawtooth oscillations. The crash events terminating long sawtooth free periods can provide seed islands for neoclassical tearing modes [Phys. Rev. Lett. 88, 105001 (2002)]]. To shorten the sawtooth periods localized current drive near the q=1 surface is a possibility. This Letter provides the first experimental evidence for the effectiveness of this method in the different physics regime associated with fast-ion-induced long sawteeth on the JET tokamak.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA