Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Transplant Proc ; 50(2): 374-381, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29579807

RESUMO

BACKGROUND: In 2011, the European Directorate for the Quality of Medicines & Healthcare of the Council of Europe launched a 3-year collaborative project to address the organ shortage and improve access to transplant health services in Council of Europe member states in the Black Sea area (Armenia, Azerbaijan, Bulgaria, Georgia, Moldova, Romania, Turkey, Ukraine, and the Russian Federation) through the development of safe and ethical donation and transplantation programs. OBJECTIVE: Support the development of donation and transplantation programs through close interstate cooperation between national health organizations and relevant stakeholders. METHODOLOGY: Several work packages (WP) were established: WP1, project coordination (European Directorate for the Quality of Medicines & Healthcare); WP2, development and implementation of an effective legislative and financial framework (Czech Republic and France); WP3, establishment of National Transplant Authorities (Italy and Portugal); and WP4, clinical practices (DTI Foundation). Data collection, surveys, and expert visits allowed for the collection of first-hand information from each participant country at national, regional, and hospital levels. RESULTS: Data analysis showed the positive impact of the project represented by a tendency to increase the total donation rates (per million people) in the participant countries (2011 vs 2013): Azerbaijan, +7.3; Armenia, -0.7; Georgia, +3.3; Bulgaria, +0.9; Moldova, +2.5; Ukraine:, +0.8; Romania, +2.3; and Turkey, +2.7. CONCLUSIONS: Increases in total donation rates are the result of a number of initiatives in the Black Sea area, including the stepwise implementation of legislative, organizational and institutional country-specific recommendations tailored by the CoE, efforts of the respective Ministries of Health in each country and synergism with other European projects in the region. These countries should invest further in implementing the recommendations that emerged from this project to improve their organ donation and transplantation programs and progress toward self-sufficiency.


Assuntos
Cooperação Internacional , Obtenção de Tecidos e Órgãos/organização & administração , Transplantes/provisão & distribuição , Mar Negro , França , Humanos , Itália , Moldávia , Portugal , Romênia , Turquia
2.
Br J Radiol ; 87(1037): 20130780, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24641347

RESUMO

OBJECTIVE: Obtaining new details of radial motion of left ventricular (LV) segments using velocity-encoding cardiac MRI. METHODS: Cardiac MR examinations were performed on 14 healthy volunteers aged between 19 and 26 years. Cine images for navigator-gated phase contrast velocity mapping were acquired using a black blood segmented κ-space spoiled gradient echo sequence with a temporal resolution of 13.8 ms. Peak systolic and diastolic radial velocities as well as radial velocity curves were obtained for 16 ventricular segments. RESULTS: Significant differences among peak radial velocities of basal and mid-ventricular segments have been recorded. Particular patterns of segmental radial velocity curves were also noted. An additional wave of outward radial movement during the phase of rapid ventricular filling, corresponding to the expected timing of the third heart sound, appeared of particular interest. CONCLUSION: The technique has allowed visualization of new details of LV radial wall motion. In particular, higher peak systolic radial velocities of anterior and inferior segments are suggestive of a relatively higher dynamics of anteroposterior vs lateral radial motion in systole. Specific patterns of radial motion of other LV segments may provide additional insights into LV mechanics. ADVANCES IN KNOWLEDGE: The outward radial movement of LV segments impacted by the blood flow during rapid ventricular filling provides a potential substrate for the third heart sound. A biphasic radial expansion of the basal anteroseptal segment in early diastole is likely to be related to the simultaneous longitudinal LV displacement by the stretched great vessels following repolarization and their close apposition to this segment.


Assuntos
Ruídos Cardíacos/fisiologia , Imagem Cinética por Ressonância Magnética/métodos , Função Ventricular Esquerda/fisiologia , Adulto , Diástole/fisiologia , Voluntários Saudáveis , Humanos , Masculino , Sístole/fisiologia
3.
Br J Radiol ; 86(1031): 20130326, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24133098

RESUMO

OBJECTIVE: Obtaining new details for rotational motion of left ventricular (LV) segments using velocity encoding cardiac MR and correlating the regional motion patterns to LV insertion sites. METHODS: Cardiac MR examinations were performed on 14 healthy volunteers aged between 19 and 26 years. Peak rotational velocities and circumferential velocity curves were obtained for 16 ventricular segments. RESULTS: Reduced peak clockwise velocities of anteroseptal segments (i.e. Segments 2 and 8) and peak counterclockwise velocities of inferoseptal segments (i.e. Segments 3 and 9) were the most prominent findings. The observations can be attributed to the LV insertion sites into the right ventricle, limiting the clockwise rotation of anteroseptal LV segments and the counterclockwise rotation of inferoseptal segments as viewed from the apex. Relatively lower clockwise velocities of Segment 5 and counterclockwise velocities of Segment 6 were also noted, suggesting a cardiac fixation point between these two segments, which is in close proximity to the lateral LV wall. CONCLUSION: Apart from showing different rotational patterns of LV base, mid ventricle and apex, the study showed significant differences in the rotational velocities of individual LV segments. Correlating regional wall motion with known orientation of myocardial aggregates has also provided new insights into the mechanisms of LV rotational motions during a cardiac cycle. ADVANCES IN KNOWLEDGE: LV insertion into the right ventricle limits the clockwise rotation of anteroseptal LV segments and the counterclockwise rotation of inferoseptal segments adjacent to the ventricular insertion sites. The pattern should be differentiated from wall motion abnormalities in cardiac pathology.


Assuntos
Função Ventricular Esquerda/fisiologia , Adulto , Feminino , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética , Masculino , Valores de Referência , Rotação , Adulto Jovem
4.
Br J Radiol ; 86(1026): 20130084, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23520226

RESUMO

OBJECTIVE: To compare the sensitivity of gastro-oesophageal reflux (GOR) scintigraphy at 5-s and 60-s frame acquisition rates. METHODS: GOR scintigraphy of 50 subjects (1 month-20 years old, mean 42 months) were analysed concurrently using 5-s and 60-s acquisition frames. Reflux episodes were graded as low if activity was detected in the distal half of the oesophagus and high if activity was detected in its upper half or in the oral cavity. For comparison purposes, detected GOR in any number of 5-s frames corresponding to one 60-s frame was counted as one episode. RESULTS: A total of 679 episodes of GOR to the upper oesophagus were counted using a 5-s acquisition technique. Only 183 of such episodes were detected on 60-s acquisition images. To the lower oesophagus, a total of 1749 GOR episodes were detected using a 5-s acquisition technique and only 1045 episodes using 60-s acquisition frames (these also included the high-level GOR on 5-s frames counted as low level on 60-s acquisition frames). 10 patients had high-level GOR episodes that were detected only using a 5-s acquisition technique, leading to a different diagnosis in these patients. No correlation between the number of reflux episodes and the gastric emptying rates was noted. CONCLUSION: The 5-s frame acquisition technique is more sensitive than the 60-s frame acquisition technique for detecting both high- and low-level GOR. ADVANCES IN KNOWLEDGE: Brief GOR episodes with a relatively low number of radioactive counts are frequently indistinguishable from intense background activity on 60-s acquisition frames.


Assuntos
Refluxo Gastroesofágico/diagnóstico por imagem , Monitorização Fisiológica/métodos , Adolescente , Animais , Criança , Pré-Escolar , Progressão da Doença , Impedância Elétrica , Monitoramento do pH Esofágico , Feminino , Refluxo Gastroesofágico/fisiopatologia , Humanos , Lactente , Recém-Nascido , Masculino , Leite , Cintilografia , Sensibilidade e Especificidade , Adulto Jovem
5.
Appl Opt ; 38(19): 3993-4000, 1999 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-18323874

RESUMO

The spatial impulse response of antenna-coupled infrared detectors with dimensions comparable with the wavelength is obtained from a two-dimensional scan of a tightly focused CO(2)-laser beam. The method uses an experimental setup with submicrometer resolution and an iterative deconvolution algorithm. The measured spatial response is compared with numerically computed near-field distributions of a dipole antenna, with good agreement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA