Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
8.
J Spec Pediatr Nurs ; 19(1): 68-79, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24393228

RESUMO

PURPOSE: The purpose of this study was to compare the accuracy and predictive validity of pH, bilirubin, and CO2 in identifying gastric tube placement errors in children. DESIGN AND METHODS: After the tube was inserted into 276 children, the CO2 monitor reading was obtained. Fluid was then aspirated to test pH and bilirubin. RESULTS: Lack of ability to obtain tube aspirate was the best predictor of NG/OG placement errors with a sensitivity of 34.9% and a positive predictive value of 66.7%. Measuring pH, bilirubin, and CO2 of tube aspirate was less helpful. PRACTICE IMPLICATIONS: Healthcare providers should suspect NG/OG tube misplacement when no fluid is aspirated.


Assuntos
Intubação Gastrointestinal , Bilirrubina/metabolismo , Líquidos Corporais , Dióxido de Carbono/metabolismo , Criança , Humanos , Concentração de Íons de Hidrogênio , Intubação Gastrointestinal/métodos , Intubação Gastrointestinal/enfermagem , Erros Médicos , Enfermagem Pediátrica , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade
9.
AJR Am J Roentgenol ; 202(2): 426-31, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24450687

RESUMO

OBJECTIVE: The objective of our study was to attempt to optimize the level of hybrid iterative reconstruction (HIR) in pediatric body CT. MATERIALS AND METHODS: One hundred consecutive chest or abdominal CT examinations were selected. For each examination, six series were obtained: one filtered back projection (FBP) and five HIR series (iDose(4)) levels 2-6. Two pediatric radiologists, blinded to noise measurements, independently chose the optimal HIR level and then rated series quality. We measured CT number (mean in Hounsfield units) and noise (SD in Hounsfield units) changes by placing regions of interest in the liver, muscles, subcutaneous fat, and aorta. A mixed-model analysis-of-variance test was used to analyze correlation of noise reduction with the optimal HIR level compared with baseline FBP noise. RESULTS: One hundred CT examinations were performed of 88 patients (52 females and 36 males) with a mean age of 8.5 years (range, 19 days-18 years); 12 patients had both chest and abdominal CT studies. Radiologists agreed to within one level of HIR in 92 of 100 studies. The mean quality rating was significantly higher for HIR than FBP (3.6 vs 3.3, respectively; p < 0.01). HIR caused minimal (0-0.2%) change in CT numbers. Noise reduction varied among structures and patients. Liver noise reduction positively correlated with baseline noise when the optimal HIR level was used (p < 0.01). HIR levels were significantly correlated with body weight and effective diameter of the upper abdomen (p < 0.01). CONCLUSION: HIR, such as iDose(4), improves the quality of body CT scans of pediatric patients by decreasing noise; HIR level 3 or 4 is optimal for most studies. The optimal HIR level was less effective in reducing liver noise in children with lower baseline noise.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Radiografia Abdominal , Radiografia Torácica
10.
Acad Radiol ; 20(10): 1297-300, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24029062

RESUMO

RATIONALE AND OBJECTIVES: The recent increasing utilization of imaging has increased the population exposure to ionizing radiation. With increasing knowledge of the potential harm of radiation exposure, efforts should be made to minimize patient radiation whenever possible, especially in young children. The purpose of this study was to use the exposure index (EI) standard to assess the potential for reducing radiation dose to babies by removing a soft comfort pad, often placed underneath the baby. The pad is located between the baby and the image detector plate. As such it absorbs x-rays that have already passed through the baby but have not yet reached the imaging detector plate. MATERIALS AND METHODS: Using a thoracic infant phantom and fixed exposure factors, we measured the percentage of the radiation exiting a neonatal chest phantom that was absorbed/attenuated by the comfort pad, before it hit the detector to create the image. We studied comfort pads of 4 different thicknesses, ranging from 0.5″ to 8″. RESULTS: Radiation beam attenuation, ranging from 12% to 72.1%, was found with all comfort pads, with increased x-ray beam attenuation occurring with increasing pad thickness. CONCLUSIONS: The study shows that comfort pads cause a high attenuation of the radiation beam, after it exits the chest phantom. As such, removal of the pads prior to radiographic exposure of babies is a method of potentially reducing patient radiation exposure in the newborn nursery.


Assuntos
Roupas de Cama, Mesa e Banho , Posicionamento do Paciente/instrumentação , Equipamentos de Proteção , Doses de Radiação , Proteção Radiológica/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Ecrans Intensificadores para Raios X , Carga Corporal (Radioterapia) , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Recém-Nascido , Masculino , Posicionamento do Paciente/métodos , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos
12.
Lancet Oncol ; 13(12): 1218-24, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23099009

RESUMO

BACKGROUND: Plexiform neurofibromas are slow-growing chemoradiotherapy-resistant tumours arising in patients with neurofibromatosis type 1 (NF1). Currently, there are no viable therapeutic options for patients with plexiform neurofibromas that cannot be surgically removed because of their proximity to vital body structures. We undertook an open-label phase 2 trial to test whether treatment with imatinib mesylate can decrease the volume burden of clinically significant plexiform neurofibromas in patients with NF1. METHODS: Eligible patients had to be aged 3-65 years, and to have NF1 and a clinically significant plexiform neurofibroma. Patients were treated with daily oral imatinib mesylate at 220 mg/m(2) twice a day for children and 400 mg twice a day for adults for 6 months. The primary endpoint was a 20% or more reduction in plexiform size by sequential volumetric MRI imaging. Clinical data were analysed on an intention-to-treat basis; a secondary analysis was also done for those patients able to take imatinib mesylate for 6 months. This trial is registered with ClinicalTrials.gov, number NCT01673009. FINDINGS: Six of 36 patients (17%, 95% CI 6-33), enrolled on an intention-to-treat basis, had an objective response to imatinib mesylate, with a 20% or more decrease in tumour volume. Of the 23 patients who received imatinib mesylate for at least 6 months, six (26%, 95% CI 10-48) had a 20% or more decrease in volume of one or more plexiform tumours. The most common adverse events were skin rash (five patients) and oedema with weight gain (six). More serious adverse events included reversible grade 3 neutropenia (two), grade 4 hyperglycaemia (one), and grade 4 increases in aminotransferase concentrations (one). INTERPRETATION: Imatinib mesylate could be used to treat plexiform neurofibromas in patients with NF1. A multi-institutional clinical trial is warranted to confirm these results. FUNDING: Novartis Pharmaceuticals, the Indiana University Simon Cancer Centre, and the Indiana University Herman B Wells Center for Pediatric Research.


Assuntos
Antineoplásicos/uso terapêutico , Neurofibroma Plexiforme/tratamento farmacológico , Neurofibromatose 1/complicações , Piperazinas/uso terapêutico , Inibidores de Proteínas Quinases/uso terapêutico , Pirimidinas/uso terapêutico , Adolescente , Adulto , Benzamidas , Criança , Pré-Escolar , Feminino , Humanos , Mesilato de Imatinib , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neurofibroma Plexiforme/complicações , Neurofibroma Plexiforme/patologia , Adulto Jovem
13.
Am J Med Genet A ; 158A(9): 2309-16, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22927185

RESUMO

In this report, we describe two siblings with short stature and severe lateral tibial bowing. In the younger sibling, the bowing was bilateral, while in the older sib, it was unilateral. However, both showed bilateral abnormalities of the distal tibial epiphyses and growth plates. Pseudoarthrosis of the left distal tibial metaphysis and subsequent spontaneous resolution of the abnormality occurred in the younger sibling. The fibulas of both children were of normal diameter and were straight, except for the distal ends. Surgery has almost completely corrected the lower leg bowing in both patients. The type of tibial bowing seen in these children can be associated with a number of syndromes, such as neurofibromatosis type I, Weismann-Netter syndrome, and a variety of environmental caused disorders, such as vitamin D deficient rickets. However, the severity of the bowing present in our patients and the absence of other clinical features differentiates this condition from those reported in the literature. We posit that the condition in the children presented here represents an as yet undescribed syndrome, which is likely to be of genetic origin.


Assuntos
Estatura , Irmãos , Tíbia/fisiopatologia , Criança , Feminino , Humanos , Radiografia , Tíbia/diagnóstico por imagem
14.
Pediatr Radiol ; 42(10): 1218-22, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22722872

RESUMO

BACKGROUND: We observed bone marrow signal changes (BMSC) in patients with plexiform neurofibromas after treatment with imatinib mesylate (Gleevec). OBJECTIVE: To evaluate the pattern and natural history of BMSC. MATERIALS AND METHODS: The data were obtained from a pilot study of imatinib mesylate in patients with plexiform neurofibromas. All patients underwent baseline and sequential whole-body STIR 1.5-T MRI after treatment. The bone marrow signal on MRI was evaluated for abnormalities, location and pattern, and any change on follow-up studies. RESULTS: The study group included 16 patients (8 males) with a median age of 14 years (range 4 to 25 years). The mean whole-body MRI follow-up duration was 1.9 years. Of the 16 patients, 14 (88%) developed BMSC. The signal change was asymmetrical in 9 of the 14 patients (64%). The appendicular skeleton was involved in all 14 patients and the axial skeleton in 3 patients (21%). BMSC was followed in 13 patients and decreased signal was seen in 9 patients (69%) after a mean duration of 1.3 years of treatment (range 0.6 to 2.9 years); no complications were observed. CONCLUSION: BMSC appeared in most patients with neurofibromatosis type 1 following treatment with imatinib mesylate. BMSC was unusually asymmetrical and involved the lower extremities. On follow-up, BMSC often showed a decrease without complications.


Assuntos
Medula Óssea/patologia , Neurofibroma Plexiforme/tratamento farmacológico , Neurofibroma Plexiforme/patologia , Neurofibromatose 1/tratamento farmacológico , Neurofibromatose 1/patologia , Piperazinas/uso terapêutico , Pirimidinas/uso terapêutico , Adolescente , Adulto , Antineoplásicos/uso terapêutico , Benzamidas , Medula Óssea/efeitos dos fármacos , Criança , Pré-Escolar , Feminino , Humanos , Mesilato de Imatinib , Imageamento por Ressonância Magnética/instrumentação , Masculino , Neurofibroma Plexiforme/etiologia , Neurofibromatose 1/complicações , Projetos Piloto , Resultado do Tratamento , Imagem Corporal Total/métodos , Adulto Jovem
15.
Radiology ; 264(1): 304; author reply 304-5, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22723568
16.
Acad Radiol ; 19(6): 651-3, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22480960

RESUMO

PURPOSE: This investigation is part of a prospective National Institutes of Health-funded study evaluating three different methods for estimating the optimal length for placement of a new nasogastric (NG) tube. Abdomen radiographs were required to determine the location of the tube tip. Our objective was to analyze different methods by which the tube location was described in the radiology report of the abdominal radiographs, and the influence of the presence or absence of a relevant clinical history. METHODS: We reviewed the imaging reports obtained following placement of a new nasogastric tube in patients enrolled in the study. RESULTS: There were 188 studies. The x-ray report contained separate description and impression sections in 154. In 24 they were combined. When the history on the requisition indicated "tube placement" as the reason for the study, the location of the tube tip was given in the impression on 134/141 (95%). When the requisition failed to mention "tube placement" as the study indication, the impression only mentioned the tube tip location 4/13 (31%). The report provided a specific location for the tube tip in 115 of the 188 cases; in 73 of the 188 cases, the report stated that the tube tip "overlies/is in the region of" the stomach. On 29 occasions the report stated that the tube, not the tube tip, was in the stomach. CONCLUSIONS: There is variation in the manner of reporting the location of NG tube tips. When the requisition fails to indicate "tube placement" as the study indication, the report impression often fails to mention the tube location.


Assuntos
Documentação/estatística & dados numéricos , Junção Esofagogástrica/diagnóstico por imagem , Intubação Gastrointestinal/instrumentação , Intubação Gastrointestinal/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Ajuste de Prótese/estatística & dados numéricos , Radiografia Intervencionista/estatística & dados numéricos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Ajuste de Prótese/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos/epidemiologia
18.
Congenit Heart Dis ; 7(2): 122-30, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22011133

RESUMO

OBJECTIVES: This study compares image quality, cost, right ventricular ejection fraction analysis, and baffle visualization between transthoracic echocardiography and cardiac magnetic resonance imaging in those status post atrial switch for transposition of the great arteries. BACKGROUND: This population requires imaging for serial evaluations. Transthoracic echocardiography is often first line but has drawbacks, many of which are addressed by cardiac magnetic resonance imaging. METHODS: Twelve patients (mean age 25 years) with relatively concurrent (mean 157 days) studies were included. Three separate echocardiography and magnetic resonance imaging physicians independently analyzed baffles, image quality, and right ventricular ejection fractions. Institutional and Medicaid charges were compared. RESULTS: For right ventricular ejection fraction, echocardiography (36.1%) underestimated cardiac magnetic resonance imaging (47.8%, P = .002). Image quality for transthoracic echocardiography was significantly rated lower than cardiac magnetic resonance imaging (P = .002). Baffles were better seen in cardiac magnetic resonance imaging (transthoracic echocardiography vs. cardiac magnetic resonance imaging: superior vena cava 86% vs. 100% [P = .063]; inferior vena cava 33% vs. 97% [P = .002]; pulmonary vein 92% vs. 100% [P = .250]). Comparing hospital charges and Medicaid reimbursement, transthoracic echocardiography respectively costs 18% and 38% less than cardiac magnetic resonance imaging. CONCLUSIONS: In conclusion, transthoracic echocardiography underestimated right ventricular ejection fraction compared to cardiac magnetic resonance imaging. Cardiac magnetic resonance imaging had consistently higher image quality and better visualization of the baffles. Cost differences are minimal. We propose that cardiac magnetic resonance imaging be considered first line for imaging in certain patients' status post atrial switch procedure.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Ecocardiografia/métodos , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico , Transposição dos Grandes Vasos/cirurgia , Adolescente , Adulto , Técnicas de Imagem Cardíaca/economia , Técnicas de Imagem Cardíaca/normas , Procedimentos Cirúrgicos Cardíacos , Ecocardiografia/economia , Ecocardiografia/normas , Feminino , Ventrículos do Coração/anatomia & histologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Custos Hospitalares , Humanos , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/normas , Masculino , Complicações Pós-Operatórias/economia , Complicações Pós-Operatórias/fisiopatologia , Veias Pulmonares/anatomia & histologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Volume Sistólico/fisiologia , Veia Cava Inferior/anatomia & histologia , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia , Veia Cava Superior/anatomia & histologia , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia , Adulto Jovem
19.
Pediatr Radiol ; 42(6): 668-73, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22057362

RESUMO

BACKGROUND: Little is known about exposure differences among hospitals. Large differences might identify outliers using excessive exposure. OBJECTIVE: We used the newly described exposure index and deviation index to compare the difference in existing radiographic exposures for neonatal portable chest radiographs among four academic children's hospitals. MATERIALS AND METHODS: For each hospital we determined the mean exposure index. We also set target exposure indices and then measured the deviation from this target. RESULTS: There was not a large difference in exposure index among sites. No site had an exposure index mean that was more than twice or less than half that of any other site. For all four sites combined, 92% of exposures had a deviation index within the range from -3 to +3. Thus exposures at each hospital were consistently within a reasonable narrow spectrum. CONCLUSION: Mean exposure index differences are caused by operational differences with mean values that varied by less than 50% among four hospitals. Ninety-two percent of all exposures were between half and double the target exposure. Although only one vendor's equipment was used, these data establish a practical reference range of exposures for neonatal portable radiographs that can be recommended to other hospitals for neonatal chest radiographs.


Assuntos
Centros Médicos Acadêmicos/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Doses de Radiação , Radiografia Torácica/estatística & dados numéricos , Radiografia Torácica/normas , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Tomografia Computadorizada por Raios X/normas , Centros Médicos Acadêmicos/normas , Feminino , Fidelidade a Diretrizes/estatística & dados numéricos , Humanos , Recém-Nascido , Masculino , Estados Unidos
20.
Pediatr Radiol ; 42(5): 584-98, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22124521

RESUMO

BACKGROUND: Digital methods are used for scoliosis imaging. Separate images of the thoracic and lumbar/sacral spine are acquired. These are then stitched into a single image. This process has some potential disadvantages. OBJECTIVE: To assess anatomical errors in digitally stitched scoliosis films. MATERIALS AND METHODS: Eighty-six scoliosis studies were evaluated for stitching errors. The incidence of a stitching error resulting in an abnormality on the stitched image that could not be verified on the source images was calculated. Subgroups were analyzed based on the presence/absence of spinal hardware and standing/supine technique. RESULTS: Fourteen exams (16%) had stitching errors that could result in a false diagnosis if not correlated with the source images. The majority were errors of vertebral alignment. There was no significant difference in error rate with the presence or absence of hardware (P = 0.73) or patient positioning (P = 0.34). CONCLUSION: 16% of digital scoliosis exams had stitching errors that could result in a false diagnosis. The error rate was not influenced by spinal hardware or patient positioning. These results stress the importance of correlating any abnormality on the stitched image with the exam's source images; if not, a false diagnosis of abnormality will be made.


Assuntos
Erros de Diagnóstico/estatística & dados numéricos , Intensificação de Imagem Radiográfica , Escoliose/diagnóstico por imagem , Artefatos , Criança , Feminino , Humanos , Masculino , Próteses e Implantes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA