Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 19(5): e0302793, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38739601

RESUMO

BACKGROUND: In cardiology, cardiac output (CO) is an important parameter for assessing cardiac function. While invasive thermodilution procedures are the gold standard for CO assessment, transthoracic Doppler echocardiography (TTE) has become the established method for routine CO assessment in daily clinical practice. However, a demand persists for non-invasive approaches, including oscillometric pulse wave analysis (PWA), to enhance the accuracy of CO estimation, reduce complications associated with invasive procedures, and facilitate its application in non-intensive care settings. Here, we aimed to compare the TTE and oscillometric PWA algorithm Antares for a non-invasive estimation of CO. METHODS: Non-invasive CO data obtained by two-dimensional TTE were compared with those from an oscillometric blood pressure device (custo med GmbH, Ottobrunn, Germany) using the integrated algorithm Antares (Redwave Medical GmbH, Jena, Germany). In total, 59 patients undergoing elective cardiac catheterization for clinical reasons (71±10 years old, 76% males) were included. Agreement between both CO measures were assessed by Bland-Altman analysis, Student's t-test, and Pearson correlations. RESULTS: The mean difference in CO was 0.04 ± 1.03 l/min (95% confidence interval for the mean difference: -0.23 to 0.30 l/min) for the overall group, with lower and upper limits of agreement at -1.98 and 2.05 l/min, respectively. There was no statistically significant difference in means between both CO measures (P = 0.785). Statistically significant correlations between TTE and Antares CO were observed in the entire cohort (r = 0.705, P<0.001) as well as in female (r = 0.802, P<0.001) and male patients (r = 0.669, P<0.001). CONCLUSIONS: The oscillometric PWA algorithm Antares and established TTE for a non-invasive estimation of CO are highly correlated in male and female patients, with no statistically significant difference between both approaches. Future validation studies of the Antares CO are necessary before a clinical application can be considered.


Assuntos
Algoritmos , Débito Cardíaco , Ecocardiografia Doppler , Análise de Onda de Pulso , Humanos , Masculino , Feminino , Débito Cardíaco/fisiologia , Idoso , Análise de Onda de Pulso/métodos , Ecocardiografia Doppler/métodos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Oscilometria/métodos
2.
BMC Cardiovasc Disord ; 20(1): 378, 2020 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-32811426

RESUMO

BACKGROUND: Maximum oxygen uptake is an established measurement of diagnosing chronic heart failure and underlies various central and peripheral factors. However, central and peripheral factors are little investigated, because they are usually measured invasively. The aim of this study was to compare non-invasively measured central and peripheral factors of oxygen uptake between patients with chronic heart failure and healthy controls. METHODS: Ten male patients with heart failure with reduced ejection fraction (62 ± 4 years; body mass index: 27.7 ± 1.8 kg/m2; ejection fraction: 30 ± 4%) and ten male healthy controls (59 ± 3 years; body mass index: 27.7 ± 1.3 kg/m2) were tested for blood pressure, heart rate, stroke volume, cardiac output, and cardiac power output (central factors) as well as muscle oxygen saturation of the vastus lateralis and biceps brachii muscle (peripheral factors) during an incremental cycling test. Stroke volume and muscle oxygen saturation were non-invasively measured by a bioreactance analysis and near-infrared spectroscopy, respectively. Additionally, a maximum isometric strength test of the knee extensors was conducted. Magnitude-based inferences were computed for statistical analyses. RESULTS: Patients had a likely to most likely lower oxygen uptake, mean arterial pressure, and heart rate at maximum load as well as very likely lower isometric peak torque. Contrary, patients had a possibly to likely higher stroke volume and muscle oxygen saturation of the vastus lateralis muscle at maximum load. Differences in cardiac output, cardiac power output, and muscle oxygen saturation of the biceps brachii muscle at maximum load were unclear. CONCLUSIONS: Non-invasively measured central and peripheral factors of oxygen uptake differ between patients with chronic heart failure and healthy controls. Therefore, it is promising to measure both types of factors in patients with chronic heart failure to optimize the diagnosis and therapy.


Assuntos
Teste de Esforço , Insuficiência Cardíaca/diagnóstico , Hemodinâmica , Contração Isométrica , Força Muscular , Consumo de Oxigênio , Músculo Quadríceps/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho , Atividades Cotidianas , Idoso , Estudos de Casos e Controles , Doença Crônica , Estudos Transversais , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Músculo Quadríceps/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA