Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Neurointerv Surg ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38418227

RESUMO

BACKGROUND: The delivery of neuroendovascular devices requires a robust proximal access platform. This demand has previously been met with a 6Fr long sheath (8Fr guide) that is placed in the proximal internal carotid artery (ICA) or vertebral artery segments. We share our experience with the first 0.088 inch 8Fr guide catheter designed for direct intracranial access. METHODS: We retrospectively reviewed a prospectively maintained IRB-approved institutional database of the senior authors to identify all cases where the TracStar Large Distal Platform (LDP) was positioned within the intracranial vasculature, defined as within or distal to the petrous ICA, vertebral artery (V3) segments, or transverse sinus. Technical success was defined as safe placement of the TracStar LDP within or distal to the described distal vessel segments with subsequent complication-free device implantation. RESULTS: Over the 41-month study period from January 2020 to June 2023, 125 consecutive cases were identified in whom the TracStar LDP was navigated into the intracranial vasculature for triaxial delivery of large devices, 0.027 inch microcatheter and greater, for aneurysm treatment (n=108, 86%), intracranial angioplasty/stenting (n=15, 12%), and venous sinus stenting (n=2, 1.6%). All cases used a direct select catheter technique for initial guide placement (no exchange). Posterior circulation treatments occurred in 14.4% (n=18) of cases. Technical success was achieved in 100% of cases. No vessel dissections occurred in any cases. CONCLUSION: The TracStar LDP is an 0.088 inch 8Fr guide catheter that can establish direct intracranial access with an acceptable safety profile. This can be achieved in a wide range of neurointerventional cases with a high rate of technical success.

2.
Interv Neuroradiol ; : 15910199241229198, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38418397

RESUMO

INTRODUCTION: Superbore 0.088″ catheters provide a platform for optimizing aspiration efficiency and flow control during stroke mechanical thrombectomy procedures. New superbore catheters have the distal flexibility necessary to navigate complex neurovascular anatomy while providing the proximal support of traditional 8F catheters. The safety and feasibility of Zoom 88™ superbore angled-tip catheters in the middle cerebral artery (MCA) segments smaller than the catheter diameter have not been previously described. METHODS: Twenty consecutive cases of acute MCA mechanical thrombectomy were retrospectively identified from the senior authors' prospectively maintained Institutional Review Board-approved database, in which the Zoom 88 (Imperative Care, Campbell, CA) catheter was successfully navigated to at least the M1 segment. Patient demographics, procedural details, and periprocedural information were analyzed. Rates and averages (standard errors) are generally reported. RESULTS: The average National Institutes of Health Stroke Scale at presentation and age were 15 ± 2 and 73 ± 3 years, respectively. The M1 and M2 occlusions were evenly distributed. The average M1 measurements before thrombectomy ranged from 2.36 ± 0.07 mm proximally to 2.00 ± 0.11 mm distally, and after thrombectomy, they ranged from 2.34 ± 0.07 mm proximally to 1.97 ± 0.10 mm distally. First-pass modified thrombolysis in cerebral infarction (mTICI) 2C/3 recanalization was achieved in 40% of cases, and final mTICI 2C/3 recanalization was achieved in 90% of cases. A single case of mild vasospasm was managed with verapamil. No hemorrhagic or periprocedural complications were noted. CONCLUSION: Superbore 0.088″ catheters with flexible distal segments can be safely navigated to the MCA to augment mechanical thrombectomy even when the MCA segment is smaller than the catheter.

3.
Interv Neuroradiol ; : 15910199231224003, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166510

RESUMO

BACKGROUND: Endovascular embolization of the middle meningeal artery (MMA) has emerged as an adjunctive and stand-alone modality for the management of chronic subdural hematomas (cSDH). We report our experience utilizing proximal MMA coil embolization to augment cSDH devascularization in MMA embolization. METHODS: MMA embolization cases with adjunctive proximal MMA coiling were retrospectively identified from a prospectively maintained IRB-approved database of the senior authors. RESULTS: Of the 137 cases, all patients (n = 89, 100%) were symptomatic and underwent an MMA embolization procedure for cSDH. 50 of the patients underwent bilateral embolizations, with 53% (n = 72) for left-sided and 47% (n = 65) for right-sided cSDH. The anterior MMA branch was embolized in 19 (14%), posterior in 16 (12%), and both in 102 (74.5%) cases. Penetration of the liquid embolic to the contralateral MMA or into the falx was present in 38 (28%) and 31 (23%) cases, respectively, and 46 (34%) cases had ophthalmic or petrous collateral (n = 41, 30%) branches. MMA branches coiled include the primary trunk (25.5%, n = 35), primary and anterior or posterior MMA trunks (20%, n = 28), or primary with the anterior and posterior trunks (54%, n = 74). A mild ipsilateral facial nerve palsy was reported, which remained stable at discharge and follow-up. Absence of anterograde flow in the MMA occurred in 137 (100%) cases, and no cases required periprocedural rescue surgery for cSDH evacuation. The average follow-up length was 170 ± 17.9 days, cSDH was reduced by 4.24 ± 0.5(mm) and the midline shift by 1.46 ± 0.27(mm). Complete resolution was achieved in 63 (46.0%) cases. CONCLUSION: Proximal MMA coil embolization is a safe technique for providing additional embolization/occlusion of the MMA in cSDH embolization procedures. Further studies are needed to evaluate the potential added efficacy of this technique.

4.
Biomedicines ; 11(8)2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37626730

RESUMO

The use of periprocedural dual antiplatelet therapy (DAPT) has significantly evolved along with innovations in the endovascular management of intracranial aneurysms. Historically, aspirin and clopidogrel have been the most commonly employed regimen due to its safety and efficacy. However, recent studies highlight the importance of tailoring DAPT regimens to individual patient characteristics which may affect clopidogrel metabolism, such as genetic polymorphisms. In the present report, a systematic review of the literature was performed to determine optimal antiplatelet use with flow diverting stents, intracranial stents, intrasaccular devices, and stent-assisted coiling. Studies were analyzed for the number of aneurysms treated, DAPT regimen, and any thromboembolic complications. Based on inclusion criteria, 368 studies were selected, which revealed the increasing popularity of alternative DAPT regimens with the aforementioned devices. Thromboembolic or hemorrhagic complications associated with antiplatelet medications were similar across all medications. DAPT with ticagrelor, tirofiban, or prasugrel are effective and safe alternatives to clopidogrel and do not require enzymatic activation. Further clinical trials are needed to evaluate different antiplatelet regimens with various devices to establish highest-level evidence-based guidelines and recommendations.

5.
J Neurointerv Surg ; 2023 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-37586816

RESUMO

BACKGROUND: Flow diversion (FD) embolization of intracranial cerebral aneurysms is an increasingly common modality where treatment success depends on adequate vessel wall apposition of the device. This study aimed to investigate off-label use of the Comaneci device for augmenting vessel wall apposition in post-deployed flow diversion stents (FDS). METHODS: Over a 20- month period, all FD cases for the treatment of internal carotid artery (ICA) aneurysms were reviewed. Cases in which the Comaneci device was used to augment vessel wall apposition were analyzed. Data including patient demographics, case characteristics, and procedural outcomes were collected and analyzed as counts. RESULTS: From a total of 74 ICA FD cases, the Comaneci device was used to improve vessel wall apposition in 22 cases (29.7%) . Of these cases, 91% were female with a mean patient age of 64.9±11.3 years, and an average aneurysm size of 4.5±2.5 mm. Comaneci device deployment and retrieval was successful in all (100%) cases, with an average fluoroscopy time of 27.3±7.8 min, an average contrast usage of 25.8±13.2 mL, and an average radiation exposure of 915.1±320.8 mGy. Only two cases (9%) required subsequent balloon angioplasty after Comaneci deployment to improve vessel wall apposition throughout the FDS. CONCLUSION: Our experience with this technique demonstrates the feasibility of using the Comaneci device for augmentation of FDS vessel wall apposition with 100% success in the deployment and retrieval of the Comaneci device.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA