Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Ophthalmol ; 16: 3491-3501, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36274677

RESUMO

Aim: To evaluate the vision-related quality of life with the National Eye Institute Refractive Error Quality of Life (NEI-RQL) questionnaire in patients with astigmatism secondary to radial keratotomy surgery who underwent topography-guided photorefractive keratectomy. Methods: Prospective non-randomized clinical trial. This study included 15 patients (30 eyes) aged > 21 years, mean age 55.1 (SD, 3.5) years, 53.3% female, with astigmatism ≤ - 6.00 D resulting from radial keratotomy, which could have been associated with hyperopia ≤ + 6.00 D. Photorefractive keratectomy with topography-guided custom ablation treatment was used in all cases. The patients answered the NEI-RQL questionnaire preoperatively and at 4 and 48 months after topography-guided photorefractive keratectomy. The following data were collected: age, sex and education level, pre-operative refraction data, visual acuity with or without correction, pachymetry, and keratometry. Results: There was a significant difference between pre-and postoperative NEI-RQL scores for the domains clarity of vision, near vision, far vision, diurnal fluctuation, activity limitations, glare, symptoms, correction dependence, appearance, and satisfaction with correction (p < 0.001). Conclusion: Topography-guided photorefractive keratectomy improved vision-related quality of life in patients with a history of irregular astigmatism secondary to radial keratotomy.

2.
Cornea ; 39(9): 1122-1131, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32472791

RESUMO

PURPOSE: To compare laser in situ keratomileusis flaps created at the programmed target thickness of 120 µm using the LenSx multifunctional and the FS200 single-functional femtosecond lasers as evaluated by anterior segment optical coherence tomography (AS-OCT). METHODS: This was a prospective, comparative, consecutive, blinded, nonrandomized study. Patients with stable refraction for over a year were consecutively allocated to the LenSx group or the FS200 group (n = 66; 33 patients in each group). All the patients underwent refractive surgery in both eyes. Previous eye surgery, ocular pathology associated with refractive errors, pregnancy, breastfeeding, and use of medication that causes ocular adverse effects constituted the exclusion criteria. Corneal topography, corneal tomography, dilated fundoscopy, applanation tonometry, ultrasonic pachymetry, dynamic and static refraction, visual acuity, and AS-OCT were evaluated before and after surgery. AS-OCT flap thickness was measured at 20 points on each cornea. RESULTS: In the LenSx group, AS-OCT flap thickness differed significantly from the target thickness at 2 of 20 points (mean differences of 2.106 and 1.803 µm). In the FS200 group, 6 of 20 measurements differed significantly (mean differences ranging from 1.121 to 2.121 µm). The 2 lasers were similarly successful in creating regular and uniform flaps. The agreement between the 2 blinded examiners regarding the AS-OCT flap thickness measurements was excellent (intraclass correlation coefficient >0.75) in both groups. CONCLUSIONS: Both femtosecond lasers were safe and capable of creating highly reproducible, uniform, and regular flaps at the target preoperative thickness of 120 µm. The LenSx multifunctional femtosecond laser offers the advantage of allowing both cataract and corneal surgeries.


Assuntos
Substância Própria/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Refração Ocular/fisiologia , Retalhos Cirúrgicos , Acuidade Visual , Substância Própria/diagnóstico por imagem , Topografia da Córnea , Feminino , Humanos , Masculino , Miopia/diagnóstico , Miopia/fisiopatologia , Período Pós-Operatório , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos
3.
Arq Bras Oftalmol ; 73(3): 244-9, 2010.
Artigo em Português | MEDLINE | ID: mdl-20730281

RESUMO

PURPOSE: To assess the relationship between potential visual acuity obtained before cataract surgery using Heine Lambda 100 retinometer with best corrected visual acuity 3 months postoperatively, as well as its correlation with the morphological pattern of the dominant cataract and the intensity of nuclear opacification. METHODS: Prospective study executed in the Ophthalmology Hospital Laser Vision in Santos of 121 eyes of 70 patients who underwent cataract surgery (phacoemulsification with intraocular lens implantation), from April to July, 2009. In the preoperative period, Heine retinometer test was performed under mydriasis and its results were compared to postoperative best corrected visual acuity three months after surgery and correlated with the morphological classification of cataracts, being considered a satisfactory result those who did not vary more than two lines in Snellen chart. RESULTS: The satisfactory cases found in our study were 86.78%, with results of visual acuity with Heine retinometer equal to the postoperative visual acuity in 34.7% of the cases. Predominant nuclear opacity N1+ has a higher reliability than N2+ and N3+ (50%, 31.3% and 26.7%, respectively). Regarding all studied eyes, statistical significance was noted (p<0.0001). CONCLUSION: In most cases Heine retinometer underestimated or maintained best corrected visual acuity 3 months postoperatively in patients who underwent cataract surgery. With respect to the morphological classification of cataracts, the higher the opacity of the nuclear lens, the greater the visual acuity underestimation.


Assuntos
Catarata/fisiopatologia , Facoemulsificação , Testes Visuais/instrumentação , Acuidade Visual/fisiologia , Humanos , Implante de Lente Intraocular , Período Pós-Operatório , Período Pré-Operatório , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento
4.
Arq. bras. oftalmol ; 73(3): 244-249, jun. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-555065

RESUMO

Objetivo: Utilizar o retinômetro de Heine Lambda 100 para avaliar a relação da acuidade visual obtida no pré-operatório de cirurgia de catarata com a acuidade visual obtida 3 meses no pós-operatório com correção óptica, bem como, sua correlação com a classificação morfológica dominante da catarata e com a intensidade da opacificação quando do tipo nuclear. Métodos: Trata-se de um estudo prospectivo realizado no Hospital Oftalmológico Visão Laser, em Santos, envolvendo 121 olhos de 70 pacientes avaliados de abril a julho 2009, submetidos à cirurgia de catarata sob a técnica de facoemulsificação com implante de lente intraocular. No período pré-operatório, foi realizado o retinômetro de Heine sob midríase e seu resultado foi comparado à melhor acuidade visual pós-operatória do terceiro mês e correlacionado com a classificação morfológica da catarata, quando do tipo nuclear, sendo denominado satisfatório aquele resultado que não variou mais do que duas linhas na tabela de Snellen. Resultados: Os resultados satisfatórios em nosso estudo foram de 86,78 por cento, apresentando resultados de acuidade visual com retinômetro de Heine igual ao resultado da acuidade visual pós-operatória em 34,7 por cento. A opacidade predominantemente nuclear N1+ tem um porcentual de acerto maior do que N2+ e N3+ (50 por cento, 31,3 por cento e 26,7 por cento, respectivamente). Em relação ao total de olhos, observamos um teste extremamente significante (p<0,0001). Conclusão: O retinômetro de Heine hipoestimou ou manteve a acuidade visual pós-operatória corrigida após 3 meses dos pacientes submetidos à facectomia, na maioria dos casos. Ao correlacionar com a classificação morfológica da catarata, observamos que, quanto maior a opacidade do cristalino do tipo nuclear, maior a hipoestimação da acuidade visual.


Purpose: To assess the relationship between potential visual acuity obtained before cataract surgery using Heine Lambda 100 retinometer with best corrected visual acuity 3 months postoperatively, as well as its correlation with the morphological pattern of the dominant cataract and the intensity of nuclear opacification. Methods: Prospective study executed in the Ophthalmology Hospital Laser Vision in Santos of 121 eyes of 70 patients who underwent cataract surgery (phacoemulsification with intraocular lens implantation), from April to July, 2009. In the preoperative period, Heine retinometer test was performed under mydriasis and its results were compared to postoperative best corrected visual acuity three months after surgery and correlated with the morphological classification of cataracts, being considered a satisfactory result those who did not vary more than two lines in Snellen chart. Results: The satisfactory cases found in our study were 86.78 percent, with results of visual acuity with Heine retinometer equal to the postoperative visual acuity in 34.7 percent of the cases. Predominant nuclear opacity N1+ has a higher reliability than N2+ and N3+ (50 percent, 31.3 percent and 26.7 percent, respectively). Regarding all studied eyes, statistical significance was noted (p<0.0001). Conclusion: In most cases Heine retinometer underestimated or maintained best corrected visual acuity 3 months postoperatively in patients who underwent cataract surgery. With respect to the morphological classification of cataracts, the higher the opacity of the nuclear lens, the greater the visual acuity underestimation.


Assuntos
Humanos , Catarata/fisiopatologia , Facoemulsificação , Testes Visuais/instrumentação , Acuidade Visual/fisiologia , Implante de Lente Intraocular , Período Pós-Operatório , Período Pré-Operatório , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA