Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Minim Invasive Ther Allied Technol ; 30(1): 47-54, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31597491

RESUMO

INTRODUCTION: To improve resection speed and to reach higher en bloc resection rates in lesions ≥ 2 cm, a novel grasp and snare EMR technique termed "EMR+", accomplished by an additional working channel (AWC), was developed. Its use compared to endoscopic submucosal dissection (ESD) is evaluated for the first time. MATERIAL AND METHODS: We prospectively conducted a randomized pre-clinical ex-vivo pilot study in explanted porcine stomachs for the comparison of EMR + with classical ESD of mucosal-based lesions. Prior to intervention, we set flat lesions with a standardized size of 3 × 3 cm. RESULTS: The median time of procedure was significantly shorter in the EMR + group (median 10.5 min, range 4.4-24 min) than in the ESD group (median 32 min, range 14-61.6 min, p < .0001). The rate of en bloc resection was significantly lower in the EMR + group (38 % vs. 95 %) (p < .0001). Nevertheless, an improvement in the learning curve for EMR + was achieved after the first 12 procedures, with a subsequent en bloc resection rate of 100 %. CONCLUSIONS: EMR + could improve the efficiency of mucosal resection procedures. Initial experience demonstrates a higher and satisfactory en bloc resection rate after going through the learning curve of EMR+.


Assuntos
Ressecção Endoscópica de Mucosa , Animais , Mucosa , Projetos Piloto , Suínos , Resultado do Tratamento
2.
Minim Invasive Ther Allied Technol ; 28(5): 277-284, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30663522

RESUMO

Introduction: Endoscopic resection techniques can successfully resect large lesions either in "en bloc" fashion or in "piece-meal" technique by using a submucosal injection solution. The aim of this study was to evaluate the safety of a novel injectable, containing thermally sensitive co-polymer from ethylenoxide and propylenoxide (LiftUp) used as submucosal injection solution.Material and methods: We conducted an in vivo animal trial in the porcine model to evaluate the LiftUp gel in a preclinical setting and to study the effectiveness of mucosal lifting and the safety of the new injectable. In seven animals a total of 63 injections and endoscopic resections were carried out in different anatomical locations (esophagus, stomach and rectum). The resection sites were controlled endoscopically one and four weeks after resection and a histopathological evaluation of the resection sites was performed after four weeks.Results: The application of LiftUp was safe and there were no negative effects on wound healing after injection and resection. A major procedural complication rate (defined as perforation and major haemorrhage) of 3.2% was registered, which undercuts the anticipated mean complication rate of 4-8%. Furthermore, there was no necessity of reinjection after the initial submucosal injection in 90.5% and no procedural complications in 98.8%. The histopathological examination of the tissue samples indicated normal wound healing with granulation tissue and epithelialisation.Conclusion: The use of LiftUp as submucosal injection solution was feasible for different endoscopic resection techniques, with high and long-lasting elevation and fewer procedural adverse events than expected at trial planning. The new injectable is a practical advancement over the current state-of-the-art of submucosal injection and could fasten up the resection procedure and make endoscopic 'en bloc' resection safer.


Assuntos
Dissecação/métodos , Endoscopia/métodos , Mucosa/cirurgia , Polímeros/uso terapêutico , Estômago/cirurgia , Animais , Humanos , Modelos Animais , Suínos