Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Eur J Surg Oncol ; 50(3): 107984, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38335874

RESUMO

BACKGROUND: Recurrent or locally advanced peri-hilar cholangiocarcinoma (PHCC) usually involves the portal vein (PV) leading to significant stenosis. With disease progression, clinical symptoms such as ascites, bleeding, and hepatic insufficiency are usually observed. Little is know about the benefit of PV stenting in relieving the symptoms associated to portal hypertension and allowing anticancer therapies. The aim of this study is to review our experience in PV stenting for PHCC patients. METHODS: From 2014 to 2022, data from PHCC patients underwent PV stenting at Verona University Hospital, Italy, were reviewed. The indications were: gastrointestinal bleeding from esophagus-gastric varices, ascites not responsive to medical therapy, severe thrombocytopenia, liver insufficiency (hepatic jaundice, coagulopathy, and/or hyperammoniemia), or asymptomatic high-grade PV stenosis. Cavernous transformation and intrahepatic thrombosis in both sides of the liver were considered contraindication. Systematic anticoagulation therapy was not administered. RESULTS: Technical success was achieved in all 16 (100 %) patients. The improvement of clinical symptoms were observed in 12 (75 %) patients. Anticancer therapy was administrated in 11 (69 %) patients. 2 (13 %) complications were observed: 1 biliary injury and 1 recurrent cholangitis that required a percutaneous trans-hepatic biliary drainage placement. Stent occlusion for tumor progression occurred in 1 patient and a re-stenting procedure was successfully performed. No case of thrombotic stent occlusion was observed during follow up. The 1-year stent patency was 86 % and the median patency period was 8 months (IQR, 4-12). CONCLUSION: PV stenting is a feasible and safe palliative treatment that improves clinical condition, allow anticancer therapies, and provide a better quality of life.


Assuntos
Neoplasias dos Ductos Biliares , Colangiocarcinoma , Tumor de Klatskin , Humanos , Tumor de Klatskin/patologia , Veia Porta/cirurgia , Resultado do Tratamento , Constrição Patológica/etiologia , Ascite/etiologia , Qualidade de Vida , Colangiocarcinoma/cirurgia , Colangiocarcinoma/patologia , Ductos Biliares Intra-Hepáticos/cirurgia , Ductos Biliares Intra-Hepáticos/patologia , Neoplasias dos Ductos Biliares/cirurgia , Neoplasias dos Ductos Biliares/complicações , Stents/efeitos adversos , Estudos Retrospectivos
3.
J Vasc Access ; 21(2): 195-203, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31379250

RESUMO

INTRODUCTION: Guidelines recommend hemodialysis graft screening to identify and repair significant (>50%) stenosis at high risk of thrombosis, but there is insufficient evidence to prefer one or other screening tool due to the lack of studies comparing all available options. METHODS: Seeking an optimal screening approach, we compared the performance of all currently used tools (duplex ultrasound to detect significant stenosis (StD) and measure access blood flow (QaD), ultrasound dilution access blood flow (QaU), static venous intra-access pressure ratio (VAPR), dynamic arterial and venous pressures measurement, and monitoring) for diagnosing significant angiography-proven stenosis (StA) and predicting incipient thrombosis (occurring within 4 months) in 62 grafts. All thrombotic and symptomatic acute hypotension episodes were recorded during follow-up. RESULTS: VAPR > 0.70 and QaU < 1600 mL/min were the best indicators to angiography for those aiming to identify the majority of StA (91% sensitivity) and QaU < 1000 mL/min or StD for those aiming to avoid unnecessary angiograms (95%-93% positive predictive value). At Cox's analysis, the only significant thrombosis predictors were acute hypotension episodes (relative risk = 4.4 (95% confidence interval = 2.2-8.8), p < 0.0001) and QaU or QaD (14% (95% confidence interval = 8-21) or 16% (95% confidence interval = 6-25) increased risk per 100 mL/min drop in Qa, p < 0.003). Thrombosis risk (adjusted for acute hypotension) became significantly higher at QaU = 1000-700 mL/min (relative risk = 3.6 (95% confidence interval = 1.6-8.2), p < 0.001) and QaD = 1300-1000 mL/min (relative risk = 3.1 (95% confidence interval = 1.1-12.8), p = 0.031). The proportion of thromboses attributable to acute hypotension was 40% (95% confidence interval = 24-57). CONCLUSIONS: Our comparative study showed that an effective screening for graft stenosis and short-term thrombosis risk can rely on Qa surveillance alone, and suggested that avoiding acute hypotension and correcting stenosis at QaU < 1000 mL/min or QaD < 1300 mL/min can contain thrombosis risk.


Assuntos
Angiografia Digital , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Determinação da Pressão Arterial , Implante de Prótese Vascular/efeitos adversos , Oclusão de Enxerto Vascular/diagnóstico , Hemodinâmica , Diálise Renal , Trombose/diagnóstico , Ultrassonografia Doppler Dupla , Idoso , Pressão Arterial , Derivação Arteriovenosa Cirúrgica/instrumentação , Velocidade do Fluxo Sanguíneo , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Trombose/etiologia , Trombose/fisiopatologia , Grau de Desobstrução Vascular , Pressão Venosa
4.
Cardiovasc Intervent Radiol ; 43(2): 302-310, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31749016

RESUMO

PURPOSE: To investigate the effectiveness of percutaneous approaches to treat bile leak and to propose an anatomical classification of biliary fistula to guide the most appropriate percutaneous approach. MATERIALS AND METHODS: Fifty-six patients with bile leakage after hepatobiliary surgery were included. Based on preoperative images and postoperative fistulogram images, three categories of bile leakage were defined. Every category was treated with non-surgical approaches (internal-external percutaneous drainage, percutaneous/endoscopic biliodigestive anastomosis with rendez-vous technique and biliodigestive percutaneous anastomosis with totally radiologic rendez-vous). RESULTS: In 44/56 (78%) patients, anatomical conformation was "direct communication" (bile ducts upstream from the leak present a direct communication with downstream ducts) and their treatment was conventional percutaneous drainage. In 5/56 (9%), anatomical conformation was "indirect communication" (bile ducts upstream from the leak communicate with downstream ducts through a bile collection) and treatment was percutaneous/endoscopic rendez-vous technique. In 7/56 (12%), anatomical conformation was "no communication" (ducts upstream from the leak are completely excluded from ducts downstream) and treatment was totally radiologic rendez-vous. In 54/56 (96%) during the follow-up, cholangiography revealed complete resolution of the leak without residual stenosis and drains were removed. Complications occurred in 12/56 (21%). Procedure-related mortality was 0%. Ten patients, after > 6 months from resolution of their fistula and drain removal, died due to cancer recurrence. Currently, 44/56 patients (77%) at long-term follow-up (> 12 months) are alive, without bile leak. CONCLUSION: Our classification helps to choose the most proper percutaneous approach in all kinds of bile leakage, even in severe cases; these are safe techniques with a high success rate.


Assuntos
Fístula Biliar/terapia , Doenças do Sistema Digestório/cirurgia , Drenagem/métodos , Complicações Pós-Operatórias/terapia , Adulto , Idoso , Anastomose Cirúrgica , Bile , Ductos Biliares/anatomia & histologia , Ductos Biliares/diagnóstico por imagem , Fístula Biliar/diagnóstico por imagem , Sistema Biliar/diagnóstico por imagem , Procedimentos Cirúrgicos do Sistema Biliar , Colangiografia/métodos , Doenças do Sistema Digestório/diagnóstico por imagem , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Pâncreas/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento
5.
Pol J Radiol ; 82: 24-27, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28203308

RESUMO

BACKGROUND: Pseudoaneurysm is a rare but potentially life-threatening vascular complication of acute pancreatitis, with a mortality rate of 20-43% in untreated patients. The treatment usually involves trans-arterial embolization or surgical resection. CASE REPORT: A 44-year-old man with a history of acute pancreatitis developed a pseudoaneurysm of the pancreatic tail, diagnosed as a splenic artery pseudoaneurysm by CT. Selective arteriography performed with the purpose of embolization did not reveal the pseudoaneurysm. The day after, under CT guidance, human thrombin (1,000 IU) was injected inside the aneurysmatic sac with its complete occlusion. A control MRI 6 months later confirmed a complete resolution of the pseudoaneurysm. CONCLUSIONS: Percutaneous coagulation of a post-pancreatitis pseudoaneurysm is a relatively easy and safe procedure, and it can be considered as an alternative to trans-arterial embolization when the pseudoaneurysm cannot be visualized on selective arteriography.

7.
Biochem Med (Zagreb) ; 26(3): 444-450, 2016 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-27812311

RESUMO

INTRODUCTION: During adrenal venous sampling (AVS) procedure, radiologists administer a contrast agent via the catheter to visualize the proper catheter position. MATERIALS AND METHODS: A patient with primary aldosteronism diagnostic-hypothesis was admitted for AVS. A venogram was performed toconfirm the catheter's position with 2mL of Iopamidol 300 mg/mL. Samples were collected with syringe connected to a hydrophilic coated catheter by low-pressure aspiration from each of the four collection sites: inferior vena cava in the suprarenal portion, inferior vena cava in the infrarenal portion, left adrenal vein, and right adrenal vein; then immediately transferred from syringe to tubes with gel separator. All tubes were centrifuged at 1200 x g for 10 minutes. RESULTS: At the end of centrifugation process, primary blood tubes containing blood from inferior vena cava and left adrenal vein exhibited the standard gel separator barrier, while tubes from right adrenal vein showed abnormal flotation of gel separator. The radiologist confirmed the usage of 2.6 mL instead of 2.0 mL of Iopamidol 300 mg/mL. This iodinated contrast media, with 1.33 g/cm3 of density, was used close to the right adrenal vein due to some difficulty to access it. CONCLUSION: The abnormal flotation of gel separator in samples taken from right adrenal vein can be explained by the usage of the iodinatedcontrast media. We suggest using plain-tubes (without gel separator) for AVS in order to avoid preanalytical nonconformities. Moreover, a blood volume equivalent to twice the catheter extension should be discarded to eliminate residual contrast media before collection of samples for laboratory assays.


Assuntos
Glândulas Suprarrenais/irrigação sanguínea , Meios de Contraste/efeitos adversos , Hiperaldosteronismo/sangue , Veias , Eletroforese/métodos , Humanos , Masculino , Pessoa de Meia-Idade
8.
J Vasc Interv Radiol ; 26(10): 1544-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26408218

RESUMO

A technique of percutaneous hepaticojejunostomy (PHJ) was developed to allow creation of a neoanastomosis in cases of hepaticojejunostomy (HJ) dehiscence when endoscopic intervention is unfeasible as a result of postsurgical anatomy. PHJ involves transhepatic biliary catheterization and transjejunal retrograde enterotomy. A rendezvous establishes the communication between the bile ducts and the jejunum. PHJ was performed in five patients, and neoanastomosis creation without residual biliary leak was achieved in all cases, with no procedure-related complications. Bilirubin levels and white blood cell counts quickly decreased after PHJ (median, 1 d; range, 1-4 d). Median survival after PHJ was 210 days (range, 45-540 d).


Assuntos
Anastomose Cirúrgica/métodos , Ductos Biliares/cirurgia , Hepatectomia/efeitos adversos , Jejunostomia/métodos , Deiscência da Ferida Operatória/etiologia , Deiscência da Ferida Operatória/cirurgia , Idoso , Feminino , Hepatectomia/métodos , Humanos , Jejunostomia/efeitos adversos , Jejuno/cirurgia , Pessoa de Meia-Idade , Resultado do Tratamento
9.
J Vasc Interv Radiol ; 25(4): 650-4, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24674222

RESUMO

Some challenging pathologic conditions of the biliary tract cannot be treated with endoscopy alone, and a combined approach with rendezvous techniques is frequently needed. Three different totally percutaneous rendezvous techniques were successfully applied in three cases. The rendezvous techniques were performed either with bilateral catheterization of bile ducts to treat a challenging type IV biliary stenosis and iatrogenic biliary damage or with biliary catheterization and percutaneous puncture of the anastomotic loop to treat a biliodigestive anastomosis failure with bile leakage.


Assuntos
Fístula Anastomótica/terapia , Cateterismo/métodos , Colestase/terapia , Drenagem/métodos , Doença Iatrogênica , Icterícia Obstrutiva/terapia , Adulto , Idoso , Fístula Anastomótica/diagnóstico , Fístula Anastomótica/etiologia , Colangiopancreatografia por Ressonância Magnética , Colestase/diagnóstico , Colestase/etiologia , Constrição Patológica , Feminino , Humanos , Icterícia Obstrutiva/diagnóstico , Icterícia Obstrutiva/etiologia , Masculino , Pessoa de Meia-Idade , Punções , Radiografia Intervencionista , Resultado do Tratamento
10.
Nephrol Dial Transplant ; 29(1): 179-87, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24166470

RESUMO

BACKGROUND: The vascular access guidelines recommend that arteriovenous fistulas (AVFs) with access dysfunction and an access blood flow (Qa) <300-500 mL/min be referred for stenosis imaging and treatment. Significant (>50%) stenosis, however, may be detected in a well-functioning AVF with a Qa > 500 mL/min, too, but whether it is worth correcting or not remains to be seen. METHODS: In October 2006, we began an open randomized controlled trial enrolling patients with an AVF with subclinical stenosis and Qa > 500 mL/min, to see how elective stenosis repair [treatment group (TX)] influenced access failure (thrombosis or impending thrombosis requiring access revision), or loss and the related cost compared with stenosis correction according to the guidelines, i.e. after the onset of access dysfunction or a Qa < 400 mL/min [control group (C)]. An interim analysis was performed in July 2012, by which time the trial had enrolled 58 patients (30 C and 28 TX). RESULTS: TX led to a relative risk of 0.47 [95% confidence interval (CI): 0.17-1.15] for access failure (P = 0.090), 0.37 [95% CI: 0.12-0.97] for thrombosis (P = 0.033) and 0.36 [95% CI: 0.09-0.99] for access loss (P = 0.041). In the setting of our study (in which all surgery was performed as in patient procedure) no significant differences in costs emerged between the two strategies. The mean incremental cost-effectiveness ratio for TX was €282 or €321 to avoid one episode of thrombosis or access loss, respectively. CONCLUSIONS: Our interim analysis showed that elective repair of subclinical stenosis in AVFs with Qa > 500 mL/min cost-effectively reduces the risk of thrombosis and access loss in comparison with the approach of the Kidney Disease Outcomes Quality Initiative (KDOQI) guidelines, raising the question of whether the currently recommended criteria for assessing and treating stenosis should be reconsidered.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Diálise Renal , Trombose/prevenção & controle , Grau de Desobstrução Vascular , Idoso , Idoso de 80 Anos ou mais , Derivação Arteriovenosa Cirúrgica/economia , Cateteres de Demora , Constrição Patológica/diagnóstico , Término Precoce de Ensaios Clínicos , Feminino , Humanos , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial , Diálise Renal/economia , Trombose/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA