Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Radiology ; 234(3): 934-9, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15681690

RESUMO

PURPOSE: To assess the effect of commonly used computed tomographic (CT) section thicknesses on metastatic tumor measurements calculated with unidimensional, bidimensional, area, and volumetric methods. MATERIALS AND METHODS: Analysis and data collection were approved by the Institutional Review Board, with waived informed patient consent. Forty-two pulmonary metastases in 10 patients (three men and seven women; age range, 43-83 years; mean age, 65.4 years) were analyzed on CT scans obtained with 3.75-, 5.0-, and 7.5-mm section thicknesses. The lesions were automatically delineated by using a three-dimensional multicriteria segmentation algorithm. Unidimensional (the largest diameter), bidimensional (the product of the two maximal perpendicular diameters), maximal cross-sectional area, and volumetric measurements were automatically obtained for each pulmonary lesion on each section thickness. Means and variances were calculated, and the differences across the three section thicknesses for each of the four measurements were studied by using linear mixed-effects models. The Levene test was used to study the equality of variances. RESULTS: Differences in the means for unidimensional, bidimensional, and area measurements were significant between a section thickness of 3.75 and 5.0 mm (unidimensional, P=.05; bidimensional, P=.05; area, P=.01) and 3.75 and 7.5 mm (unidimensional, P=.06; bidimensional, P=.03; area, P=.02), but not 5.0 and 7.5 mm. There was a significant difference in volumetric measurement as section thickness decreased from 7.5 to 5.0 mm (P <.001) and from 7.5 to 3.75 mm (P <.001). Although there was a slight trend for differences in the variances across section thickness for each measurement, none of the differences were significant. CONCLUSION: Volumetric tumor measurements change with a reduction in section thickness from 7.5 to 5.0 and 3.75 mm. For unidimensional measurement, no change was found when thickness decreased from 7.5 to 5.0 mm.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/secundário , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Modelos Lineares , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA