Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Insights Imaging ; 15(1): 228, 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39298015

RESUMO

Focal liver lesions are frequently encountered during imaging studies, and hemangiomas represent the most common solid liver lesion. Liver hemangiomas usually show characteristic imaging features that enable characterization without the need for biopsy or follow-up. On the other hand, there are many benign and malignant liver lesions that may show one or more imaging features resembling hemangiomas that radiologists must be aware of. In this article we will review the typical imaging features of liver hemangiomas and will show a series of potential liver hemangiomas' mimickers, giving radiologists some hints for improving differential diagnoses. CRITICAL RELEVANCE STATEMENT: The knowledge of imaging features of potential liver hemangiomas mimickers is fundamental to avoid misinterpretation. KEY POINTS: Liver hemangiomas typically show imaging features that enable avoiding a biopsy. Many benign and malignant liver lesions show imaging features resembling hemangiomas. Radiologists must know the potentially misleading imaging features of hemangiomas' mimickers.

2.
Eur Radiol ; 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39122853

RESUMO

PURPOSE: To evaluate the impact of the use of lean body weight (LBW)-based contrast material (CM) dose and bolus tracking technique on portal venous phase abdominal CT image quality. MATERIALS AND METHODS: IRB-approved prospective study; informed consent was acquired. In the period July-November 2023, we randomly selected 105 oncologic patients scheduled for a portal venous phase abdominal CT to undergo our experimental protocol (i.e., 0.7 gI/Kg of LBW CM administration and bolus tracking on the liver). Included patients had performed a "standard" portal venous phase abdominal CT (i.e., 0.6 gI/Kg of total body weight (TBW) contrast material administration and 70 s fixed delay) on the same scanner within the previous 12 months. One reader evaluated CT images measuring liver, portal vein, kidney cortex, and spleen attenuation; values were normalized to paraspinal muscles. RESULTS: Median administered contrast dose (350 mgI/mL CM) was 99 mL (IQR: 81-115 mL) using the experimental protocol and 110 mL (IQR: 100-120 mL) using the standard one (p < 0.0001). Median acquisition delay using the experimental protocol was 65" (IQR 59-73"). Median normalized hepatic enhancement was significantly higher using the experimental protocol (1.97, IQR: 1.83-2.47 vs. 1.86, IQR: 1.58-2.11; p < 0.0001). Median normalized portal vein enhancement was significantly higher using the experimental protocol (3.43, IQR: 2.73-4.04 vs. 2.91, IQR: 2.58-3.41; p < 0.0001). No statistically significant differences were found in the kidneys' cortex and aorta normalized enhancement (p > 0.05). CONCLUSION: The combination of LBW-based CM dose administration and bolus tracking allows a significant CM dose reduction and a significant liver and portal vein enhancement increase. CLINICAL RELEVANCE STATEMENT: Lean body weight-based contrast material (CM) dose administration and bolus tracking technique in portal venous phase CT scans overcome differences in body composition and hemodynamics, improving reproducibility. It allows a significant CM dose reduction with increased liver and portal vein enhancement. KEY POINTS: Lean body weight (LBW)-based contrast material (CM) dosing could be superior to total body weight dosing. Portal venous phase CT with a liver bolus tracking technique improved liver and spleen enhancement with a reduced contrast dose. The combination of LBW-based CM dosing and liver bolus tracking technique enables more "customized" CT examinations.

3.
Eur Radiol ; 2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39068376

RESUMO

OBJECTIVES: To assess the influence of peak tube voltage peak setting on adrenal adenomas (AA) attenuation on unenhanced abdominal CT. MATERIALS AND METHODS: IRB-approved retrospective observational cohort study. We included 89 patients with imaging-defined AAs with shortest diameter > 6 mm who underwent two or more unenhanced abdominal CTs using at least two different peak tube voltage settings. Two readers independently measured adenoma attenuation on different CT acquisitions by drawing a round ROI on 3 mm thick axial MPR reconstructions encompassing at least 2/3 of the lesion's surface. The mean of the values measured by the two readers was used for further analysis. Interobserver variability was assessed (Intraclass Correlation Coefficient). Attenuation values measured on 100, 110 and 140 kVp acquisitions were compared with standard 120 kVp ones (Bland-Altman analysis). RESULTS: We included 275 unenhanced abdominal CTs (3.1 ± 0.9/patient) in image analysis; 131 acquired at 120 kVp, 65 at 100 kVp, 59 at 110 kVp, and 20 at 140 kVp. 107 lesions were detected in 89 patients (1-4/patient), with a mean maximum diameter of 17 ± 6 mm. Interobserver agreement in attenuation measurement was excellent (ICC: 0.95, CI (92-97)). Median adenoma attenuation was significantly lower on 100 kVp images than on 120 kVp ones (-1 HU, IQR (-5 to 3.6), vs, 2.5 HU, IQR (-1.5 to 8.5); p < 0.001) whereas we didn't find statistically significant differences in adenoma attenuation between 110 kVp or 140 kVp and 120 kVp ones. CONCLUSION: AA attenuation is significantly lower on unenhanced CT scans acquired at 100 kVp than on those acquired at "standard" 120 kVp. CLINICAL RELEVANCE STATEMENT: AA attenuation is significantly lower at 100 kVp in comparison to 120 kVp. This might be exploited to increase unenhanced CT sensitivity in adenoma characterisation, but further studies including non-adenoma lesions are mandatory to confirm this hypothesis. KEY POINTS: CT scans are often acquired using peak tube voltage settings different from the "standard" 120 kVp. AA attenuation varies if CT scans are acquired using different tube peak voltage settings. At 100 kVp AAs show a significantly lower attenuation than at 120 kVp.

4.
Eur J Radiol ; 170: 111217, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38042020

RESUMO

PURPOSE: To assess the diagnostic performance of MRI in distinguishing between leiomyomas and malignant/potentially malignant mesenchymal neoplasms in patients with rapidly enlarging/sonographically suspicious uterine masses. METHODS: IRB-approved retrospective study including 88 patients (51 ± 11 years) who underwent MRI for rapidly enlarging/sonographically suspicious uterine mass at our Institution between January 2016 and December 2021, followed by surgery or >12 months follow-up. Qualitative image analysis was independently performed by 2 radiologists and included lesion's margins (sharp/irregular), architecture (homogeneous/inhomogeneous), presence of endometrial infiltration (yes/no), necrotic areas (yes/no), hemorrhagic areas (yes/no), predominant signal intensity on T1-WI, T2-WI, CE T1-WI, DWI, and ADC map. The same radiologists performed quantitative image analysis in consensus, which included lesion's maximum diameter, lesion/myometrium signal intensity ratio on T2-WI and CE T1-weighted images, lesion/endometrium signal intensity ratio on DWI and ADC map and necrosis percentage. Lesions were classified as benign or malignant. Imaging findings were compared with pathology and/or follow-up. RESULTS: After surgery (52/88 patients) or follow-up (36/88 patients, 33 ± 20 months), 83/88 (94.3%) lesions were classified as benign and 5/88 (5.7%) as malignant/potentially malignant. Presence of necrotic areas, high necrosis percentage, hyperintensity on DWI and high lesion/endometrium DWI signal intensity ratio were significantly associated with malignant/potentially malignant lesions (p = 0.027, 0.002, 0.008 and 0.015, respectively). The two readers identified malignant/potentially malignant lesions with 95.5% accuracy, 80.0% sensitivity, 96.4% specificity, 57.1 % PPV, 93.3% NPV. CONCLUSION: MRI has high accuracy in identifying malignant/potentially malignant myometrial masses. In everyday practice, however, MRI positive predictive value is relatively low given the low pre-test malignancy probability.


Assuntos
Leiomioma , Sarcoma , Neoplasias Uterinas , Feminino , Humanos , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/patologia , Estudos Retrospectivos , Diagnóstico Diferencial , Sensibilidade e Especificidade , Leiomioma/diagnóstico por imagem , Leiomioma/patologia , Imageamento por Ressonância Magnética/métodos , Necrose , Imagem de Difusão por Ressonância Magnética/métodos
5.
Pediatr Gastroenterol Hepatol Nutr ; 24(3): 265-272, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34046329

RESUMO

PURPOSE: Hypertrophic pyloric stenosis (HPS) is the most common cause of gastric obstruction in newborns. Extra-mucosal pyloromyotomy can be performed through a small laparotomy or laparoscopy. The aim of this study was to compare the two surgical techniques. We also analyzed the incidence of HPS in infants in the last 10 years in relation to the demographic trend of our province. METHODS: We analyzed all the cases of HPS treated at our Unit between January 2010 and December 2019. The data were obtained from operating systems. Data about the demographic trends, in particular, the number of births and the population residing in the province of Verona from 2010 to 2019, were also retrieved. RESULTS: During the study period, 60 patients were treated for HPS and met the inclusion criteria. Of these, 56 males and 4 females with an average age of 38±14 days at surgery were included. No differences were found in terms of the duration of surgery, post-operative complications, duration of hospitalization, and weight at the time of surgery. The only statistically significant data was the chlorine level in cases with and without post-operative vomiting (97±3.5 vs. 102±3.3 mmol/L, p<0.05). There was a lower incidence of HPS from 2014 to 2019; however, there was no significant evidence regarding the correlation between this and the reduced birth rate recorded in the province of Verona during the same period. CONCLUSION: Although laparoscopic pyloromyotomy is a highly complex procedure, it is a feasible alternative to the classic open technique.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA