Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eye (Lond) ; 38(Suppl 1): 9-14, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38580741

RESUMO

BACKGROUND/OBJECTIVE: To evaluate the visual performance of a purely refractive extended depth of focus (EDF) intraocular lens (IOL). SUBJECTS/METHODS: A prospective, multi-center, randomized, subject/evaluator-masked study. Subjects were bilaterally implanted with the EDF test (Model ZEN00V, N = 60) or an enhanced monofocal control (Model ICB00, N = 57) IOL. Monocular corrected distance (CDVA), intermediate (DCIVA), near acuities (DCNVA) and patient reported visual symptoms were evaluated at the 6-month visit. Monocular mesopic contrast sensitivity (CS) and depth of focus (DOF) testing were assessed at 3 months. RESULTS: CDVA (Mean ± SD) was -0.06 ± 0.08 for test and -0.05 ± 0.08 logMAR for control groups. DCIVA was 0.13 ± 0.08 for test and 0.18 ± 0.14 logMAR for control groups (p = 0.0127). DCNVA was 0.37 ± 0.10 for test and 0.43 ± 0.16 logMAR for control groups (p = 0.0137). Test lens was statistically superior for intermediate and near. Overall, 91.7% (halos), 95.0% (starbursts) and 95.0% (glare) of test lens patients reported that they did not experience, were not bothered, or were slightly bothered by specific visual symptoms, compared to 98.2%, 100% and 96.5% in the control group. The DOF range over which monocular visual acuity was 0.20 logMAR or better was -1.6 D for the test lens. Mesopic CS was comparable between both groups, falling within 0.11 log units for all measured cycles per degree with and without glare. CONCLUSION: The EDF IOL demonstrated extended range of vision and statistically superior intermediate and near performance compared to the monofocal IOL. Distance visual acuity, contrast sensitivity and dysphotopsia profile were similar to the monofocal IOL.


Assuntos
Sensibilidades de Contraste , Percepção de Profundidade , Implante de Lente Intraocular , Lentes Intraoculares , Pseudofacia , Acuidade Visual , Humanos , Estudos Prospectivos , Acuidade Visual/fisiologia , Feminino , Masculino , Sensibilidades de Contraste/fisiologia , Idoso , Pessoa de Meia-Idade , Percepção de Profundidade/fisiologia , Pseudofacia/fisiopatologia , Desenho de Prótese , Refração Ocular/fisiologia , Facoemulsificação , Método Duplo-Cego , Satisfação do Paciente
2.
J Cataract Refract Surg ; 48(11): 1270-1276, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35545816

RESUMO

PURPOSE: To compare the clinical performance of the TECNIS Synergy multifocal (model ZFR00V) intraocular lens (IOL) with that of the AcrySof PanOptix Trifocal (model TFNT00) IOL in patients undergoing bilateral cataract surgery. SETTING: Multicenter clinical setting. DESIGN: Prospective randomized comparative study. METHODS: Patients aged 22 years or older were randomly assigned (2:1) to bilateral implantation with ZFR00V or TFNT00 IOLs. End points included the mean binocular distance-corrected near visual acuity (DCNVA) at 40 cm, photopic and mesopic DCNVAs at 33 cm, photopic low-contrast corrected distance visual acuity (CDVA) and mesopic CDVA, nondirected patient responses to an ocular/visual symptoms questionnaire, and safety. RESULTS: Of the 150 patients implanted with IOLs, 95 of the 97 patients with ZFR00V IOLs and 52 of the 53 patients with TFNT00 IOLs completed the 3-month follow-up. Most patients in the ZFR00V and TFNT00 groups achieved 20/25 or better binocular CDVA (100% vs 96.2%) and DCNVA measured at 40 cm (88.4% vs 75.0%) and 33 cm (78.9% vs 51.9%). The mean between-group difference in binocular DCNVA at 40 cm favored ZFR00V IOLs (0.5 lines Snellen; 95% CI, 0.012 to 0.089; P ≤ .05). Similarly, the mean binocular photopic and mesopic DCNVAs at 33 cm (0.8 lines Snellen each; both P ≤ .05 vs TFNT00) and photopic high-contrast and low-contrast CDVA (0.5 lines Snellen each; both P ≤ .05 vs TFNT00) favored ZFR00V IOLs. Patient-reported ocular/visual symptoms and safety were generally similar between the 2 IOLs. CONCLUSIONS: The ZFR00V IOL showed an extensive range of vision, particularly through near distances, and better mesopic performance than the TFNT00 IOL in patients undergoing cataract surgery.


Assuntos
Catarata , Lentes Intraoculares , Lentes Intraoculares Multifocais , Facoemulsificação , Humanos , Estudos Prospectivos , Refração Ocular , Desenho de Prótese , Visão Binocular/fisiologia , Pseudofacia
3.
Clin Ophthalmol ; 14: 2291-2300, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32943830

RESUMO

PURPOSE: To evaluate the clinical handleability and acceptability of a novel preloaded intraocular lens (IOL) delivery system for implantation of the TECNIS ZCB00 IOL (Johnson & Johnson Surgical Vision, Inc., Santa Ana, CA, USA) during routine small-incision cataract surgery. SUBJECTS AND METHODS: In this prospective, open-label, noncomparative, unilateral or bilateral, multicenter study, adult subjects with unilateral or bilateral cataracts scheduled for IOL implantation were enrolled. Surgeons and surgical technicians completed per-eye day-of-surgery and end-of-surgical-day questionnaires. The primary endpoint of the study was the rate of acceptable overall clinical performance of the preloaded IOL delivery system. Other endpoints included additional responses from the questionnaires, preimplantation incision size, and safety. RESULTS: The study included 91 eyes that underwent cataract surgery and IOL implantation using the preloaded delivery system and were available for the 1-day postoperative visit. Five surgeons and 14 surgical technicians from four investigational sites participated in the study. The rate of acceptable overall clinical performance was 100% (91/91) of eyes, with most responses (78/91; 85.7%) being the highest possible rating of 5 (very satisfied). Favorable responses by most surgeons and surgical technicians regarding additional endpoints further highlighted the handleability and acceptability of the preloaded delivery system. No ocular adverse events or lens findings (ie, no cases of IOL instability, haptic breakage, IOL marking, or crimping) were reported. CONCLUSION: The results of this study demonstrated that this preloaded IOL delivery system was safe and effective during routine small-incision cataract surgery. TRIAL REGISTRATION: German Clinical Trials Register identifier, DRKS00014757.

4.
Invest Ophthalmol Vis Sci ; 60(1): 147-153, 2019 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-30629728

RESUMO

Purpose: We assess the safety and effectiveness of intranasal neurostimulation to promote tear production via the nasolacrimal pathway in subjects with dry eye disease. Methods: A multicenter, randomized, controlled, double-masked pilot study was conducted in adults with dry eye diagnosis and at least one eye with corneal fluorescein staining ≥2 in at least one region or a sum of all regions ≥5 (National Eye Institute grading), basal Schirmer test score ≤10 mm, a cotton-swab stimulated Schirmer score ≥7 mm higher, and an Ocular Surface Disease Index score ≥23. Subjects were randomized to receive active intranasal neurostimulation or sham control intranasal stimulation 4 to 8 times per day. Assessments were scheduled before (unstimulated) and during (stimulated) device application at days 0, 7, 14, 30, and 90. The primary effectiveness endpoint was stimulation-induced change in Schirmer test (with anesthesia) score. Primary safety measure was incidence of device-related adverse events (AEs). Results: Fifty-eight subjects were randomized at nine sites in Australia and New Zealand; 56 completed the 90-day study. Stimulation-induced change in Schirmer score was significantly greater with active intranasal (mean ± SEM, 9.0 ± 2.0) than sham control intranasal stimulation (0.4 ± 0.6; P < 0.001) at day 90. Similar results were observed at days 0, 7, 14, and 30 (P < 0.001). No serious device-related AEs were observed. Mild nosebleed, the most common device-related AE, was reported in five (16.7%) subjects. Conclusions: Intranasal neurostimulation was effective in inducing acute tear production after 90 days of use and generally was well tolerated in subjects with dry eye disease.


Assuntos
Síndromes do Olho Seco/terapia , Mucosa Nasal/inervação , Lágrimas/fisiologia , Estimulação Elétrica Nervosa Transcutânea/métodos , Adulto , Idoso , Método Duplo-Cego , Síndromes do Olho Seco/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Equipamentos de Proteção , Microscopia com Lâmpada de Fenda , Estimulação Elétrica Nervosa Transcutânea/efeitos adversos
5.
J Cataract Refract Surg ; 44(7): 922, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-30055704
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA