Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39161931

RESUMO

Background: The current literature shows similar clinical outcomes between first metatarsophalangeal (MTP) joint arthrodesis and synthetic cartilage implant (SCI) hemiarthroplasty in the treatment of hallux rigidus; however, prior studies have not reported validated patient-reported outcome measures (PROMs). To our knowledge, this is the first study to compare PROMs using 6 domains of the validated Patient-Reported Outcomes Measurement Information System (PROMIS) in patients treated for hallux rigidus with MTP joint arthrodesis and with SCI hemiarthroplasty. In addition, this novel study provides comparative data on the complication and revision rates for each procedure. Methods: A single-center, retrospective registry search identified all patients with preoperative PROMIS scores who underwent MTP joint arthrodesis or SCI hemiarthroplasty for hallux rigidus between February 2016 and June 2021. The study aimed to determine if the 2 procedures showed statistically or clinically equivalent PROMIS scores in 6 domains: physical function, pain interference, pain intensity, global physical health, global mental health, and depression. A multivariable linear regression analysis was performed to compare adjusted 1-year postoperative PROMIS scores between the 2 cohorts. Complication and revision rates were also compared. Results: The study included 82 patients who underwent SCI hemiarthroplasty and 101 who underwent MTP joint arthrodesis. Demographic data and preoperative hallux rigidus severity showed no significant differences between the cohorts. PROMIS scores were mostly comparable between the 2 groups, except for the pain intensity domain. The patients who underwent MTP joint arthrodesis exhibited significantly better pain relief at 1 and 2 years postoperatively, which was supported by adjusted postoperative PROMIS scores. At 2 years, the SCI group had worse pain intensity scores and lower global physical health scores. There were no differences between the cohorts in additional PROMIS scores or complication data. Conclusions: While outcomes in most of the domains were similar, MTP joint arthrodesis was more effective at mitigating pain intensity compared with SCI hemiarthroplasty. This information can guide patient counseling and decision-making when considering surgical intervention for hallux rigidus. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

2.
J Arthroplasty ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38759819

RESUMO

BACKGROUND: The impact of a preoperative self-reported nickel allergy in patients undergoing primary total knee arthroplasty (TKA) remains unclear. The aim of this study was to compare the revision rates and outcomes of patients who have a self-reported nickel allergy undergoing primary TKA to patients who do not have a self-reported nickel allergy. METHODS: Over 5 years, a total of 284 TKAs in patients who have and 17,735 in patients who do not have a self-reported nickel allergy were performed. Revision rates and differences in preoperative and postoperative patient-reported outcome measures, including Knee Osteoarthritis Outcome Score Joint Replacement (KOOS JR), Visual Analog Scale, Lower Extremity Activity Scale, and the Patient-Reported Outcomes Measurement Information System Mental and Physical Scores, were compared. RESULTS: Survivorship free of all-cause revision at 1 year was similar for patients who have and do not have a self-reported nickel allergy (99.5% [95% CI (confidence interval): 98.6 to 100.0] versus 99.3% [95% CI: 99.1 to 99.4]), P = .49). Patients who have a self-reported nickel allergy undergoing primary TKA had no difference in KOOS JR, Visual Analog Scale, or Lower Extremity Activity Scale scores at 6 weeks and 1 year and slightly worse Patient-Reported Outcomes Measurement Information System mental and physical scores at 6 weeks compared to patients who did not have an allergy. Matched analysis revealed no difference in 6-week or 1-year KOOS, JR scores between patients who did and did not have a self-reported nickel allergy when stratified by implant class (nickel-free versus standard cobalt-chromium) (P = .113 and P = .415, respectively). CONCLUSIONS: Patients who have a self-reported nickel allergy can be advised that, on average, their clinical outcome scores will improve similarly to patients who do not have a self-reported nickel allergy, and revision rates will be similar.

3.
J Bone Joint Surg Am ; 106(9): 767-775, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38442190

RESUMO

BACKGROUND: Total ankle replacements (TARs) have rapidly advanced in terms of volume, technique, design, and indications. However, TARs are still at risk for early mechanical failure and revision. Prior studies have investigated potential risk factors for failure, but have been limited to smaller series or older implants. This study sought to identify risk factors for early mechanical failure in modern TAR. METHODS: This is a retrospective study of a single-institution registry. Five surgeons contributed cases involving patients who underwent a primary TAR with any implant. Implants were grouped on the basis of the type of fixation. The primary outcome was early mechanical failure (revision with component removal for a non-infectious etiology, that is, subsidence, aseptic loosening, and/or malalignment). Logistic regression determined the effects of age, weight, hindfoot arthrodesis, implant type, and radiographic deformity on failure. RESULTS: The 731 included patients had a mean follow-up of 2.7 years. Ten percent (71 patients) had hindfoot arthrodesis. There were 33 mechanical failures (4.5%) at a mean of 1.7 years after the index surgical procedure. Our model demonstrated that hindfoot arthrodesis was associated with 2.7 times greater odds of failure (p = 0.045), every 10 kg of body weight increased the odds of tibial-sided failure by 1.29 times (p = 0.039), and implants with more extensive tibial fixation (stems or keels) lowered the odds of tibial failure by 95% (p = 0.031). CONCLUSIONS: In patients with uncontrollable risk factors (hindfoot arthrodesis) or risk factors that may or may not be modifiable by the patient (weight), implants with more robust tibial fixation may be able to reduce the risk of early mechanical failure. Further research is warranted to support efforts to decrease early failure in TAR. LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Substituição do Tornozelo , Falha de Prótese , Reoperação , Humanos , Artroplastia de Substituição do Tornozelo/instrumentação , Artroplastia de Substituição do Tornozelo/efeitos adversos , Artroplastia de Substituição do Tornozelo/métodos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Fatores de Risco , Idoso , Reoperação/estatística & dados numéricos , Prótese Articular/efeitos adversos , Desenho de Prótese , Articulação do Tornozelo/cirurgia , Artrodese/instrumentação , Artrodese/métodos , Artrodese/efeitos adversos , Adulto
4.
J Arthroplasty ; 39(7): 1765-1770, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38301980

RESUMO

BACKGROUND: There is no consensus on whether direct anterior approach (DAA) or postero-lateral approach (PLA) total hip arthroplasty (THA) confers a lower risk of postoperative complications. Robotic assistance in THA results in a more consistently accurate component position compared to manual THA. The objective of this study was to compare rates of dislocation, reoperation, revision, and patient-reported outcome measures between patients undergoing DAA and PLA robotic-assisted primary THA. METHODS: We identified 2,040 consecutive robotic-assisted primary THAs performed for primary osteoarthritis, using DAA (n = 497) or PLA (n = 1,542) between 2017 and 2020. The mean follow-up was 18 months. Kaplan-Meier analysis estimated survivorship free of dislocation, reoperation, and revision. Achievement of patient acceptable symptom state and minimum clinically important difference were used to compare changes in the Hip Disability and Osteoarthritis Outcome Score, Joint Replacement (HOOS JR) and Visual Analog Scale. RESULTS: Dislocation was rare in this series (14 in 2,040, 0.7%), including 1 of 497 (0.2%) in the DAA cohort and 13 of 1,542 (0.8%) in the PLA cohort (P = .210). There was no difference in 2-year reoperation-free survivorship (97.8 versus 98.6%, P = .59) or revision-free survivorship (98.8 versus 99.0%, P = .87) at any time point. After controlling for age, sex, and body mass index, there was no difference in dislocation, reoperation, or revision. At 6-week follow-up, after controlling for age, sex, and body mass index, patients in the DAA cohort had higher odds of achieving HOOS JR minimum clinically important difference (odds ratio = 2.01, P = .012) and HOOS JR patient acceptable symptom state (odds ratio = 1.72, P = .028). There were no differences in patient-reported outcome measures by 3 months. CONCLUSIONS: For robotic-assisted primary THA, DAA may confer enhanced early (<6 weeks) functional recovery compared to the PLA, but there was no significant difference in postoperative dislocation, reoperation, or revision rates.


Assuntos
Artroplastia de Quadril , Osteoartrite do Quadril , Medidas de Resultados Relatados pelo Paciente , Complicações Pós-Operatórias , Reoperação , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia de Quadril/métodos , Reoperação/estatística & dados numéricos , Feminino , Masculino , Procedimentos Cirúrgicos Robóticos/métodos , Idoso , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Adulto