Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
J Neurointerv Surg ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38991733

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) device is designed to treat wide-necked bifurcation aneurysms. The WEB 17 is the latest iteration and can be delivered through a 0.017″ microcatheter. The CLEVER study demonstrated that WEB 17 is safe and effective for providing protection against bleeding or rebleeding at 1 month and 1 year. OBJECTIVE: To evaluate angiographic stability at 1 year. METHODS: The CLEVER study was a prospective multicenter study conducted in 17 European centers, involved 163 subjects, comprising 60 ruptured and 103 unruptured aneurysms. Independent assessment of 1-year follow-up imaging was incorporated into the study design. RESULTS: Aneurysm diameters ranged from 2.0 to 9.2 mm, with 95.7% being broad-based (dome-to-neck ratio <2). Follow-up imaging at 1 year was completed for 146 out of 163 subjects (89.6%) and evaluated by an independent core laboratory. The primary efficacy endpoint of adequate occlusion without re-treatment at 1 year was achieved for 120 (82.2%) of all subjects. At 1 year, the adequate occlusion rate was 86.5% for ruptured aneurysms (73.1% complete occlusion) and 82.4% for unruptured aneurysms (57.1% complete occlusion). The overall re-treatment rate at 1 year was 2.6% (4/152), with 3.1% (3/97) for unruptured aneurysms and 1.8% (1/55) for ruptured aneurysms CONCLUSION: Delivery of the WEB 17 via 0.017 inch catheters represents a significant evolution of the WEB design. The results of CLEVER presented here demonstrate that it maintains the same efficacy as previous generations of WEB.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38991770

RESUMO

BACKGROUND AND PURPOSE: A single aspiration maneuver using a large volume syringe is a common and effective technique for aspiration thrombectomy. Multiple aspiration cycles using large aspiration syringes has been proposed as a means to improve efficacy over single aspiration. In this study, we sought to investigate the efficacy of a "triple aspiration technique" where a large volume syringe is cycled three times prior to catheter retraction during aspiration thrombectomy. MATERIALS AND METHODS: A 3D-printed adult vasculature was used as a benchtop thrombectomy platform. Fibrin-rich and red blood cell-rich clots were prepared in centrifuge tubes using human plasma, red blood cells, and calcium chloride. Next, clots were placed in the carotid terminus of the model, and the performances of three different aspiration techniques-triple syringe, single syringe, and continuous pump aspiration-were compared in a randomized manner (1:1:1). Outcomes of interest included first-pass efficacy (FPE), complete clot removal (final mTICI 2c/3), the number of thrombectomy attempts to achieve mTICI 2c/3, vacuum pressure, and distal embolization. The distal emboli were detected using a 70-micron cell strainer placed at the outflow of the model and quantified using an image processing algorithm. The vacuum pressures were measured using a pressure transducer (Honeywell, NC, USA). RESULTS: A total of 102 replicates were performed, 34 for each technique. The triple aspiration technique provided a significantly higher rate of FPE than the syringe and pump aspiration techniques (67.6% vs. 41.1%, p= 0.02). Additionally, the triple aspiration technique achieved complete clot removal with a significantly lower number of thrombectomy attempts compared to single syringe aspiration (1.2 ± 0.5 vs. 1.8 ± 0.8, p=0.005). The triple aspiration technique generated significantly higher vacuum pressure than both the single syringe and vacuum pump aspiration (28.3 ± 0.2 vs. 27.2 ± 0.3 (p= 0.002) and 26.2 ± 0.4 (p=0.001), respectively). The differences in complete clot removal and distal embolization parameters were not statistically significantly different across the groups. CONCLUSIONS: Our findings suggest that the triple aspiration technique can improve FPE rates and vacuum pressure in aspiration thrombectomy. Further studies are needed to examine the safety and efficacy of triple aspiration in the clinical setting. ABBREVIATIONS: AcommA = anterior communicating artery; FPE = first pass efficacy; ICA = internal carotid artery; MCA = middle cerebral artery; MT = mechanical thrombectomy; mTICI = modified thrombolysis in cerebral infarction scale; PcommA = posterior communicating artery.

3.
J Neurointerv Surg ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38862208

RESUMO

The New Zealand rabbit elastase-induced arterial aneurysm of the right common carotid artery remains a widely used model for assessing the effectiveness and safety of new neuroendovascular devices.1 This model offers a simple and reliable platform for pre-clinical in vivo investigations, crucial for comprehending the biological processes underlying aneurysm healing after endovascular treatment.2 Notably, the induced aneurysm exhibits morphological, hemodynamic, and histological characteristics similar to human intracranial aneurysms. The creation of the aneurysm is performed using open and endovascular techniques. Each step of the procedure requires a meticulous and controlled gesture to ensure reproducibility of the aneurysm and minimize animal misuse. In video 1 we present a step-by-step procedural guide for aneurysm creation and follow-up. We hope this resource will help in promoting this model and provide useful guidance for researchers in the field.neurintsurg;jnis-2024-021912v1/V1F1V1Video 1Surgical procedure of creating elastase-induced aneurysms in rabbits.

4.
J Neuroradiol ; 51(5): 101207, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38838915

RESUMO

Intradural spinal cord arteriovenous shunts are challenging vascular lesions with poor prognosis if left untreated. Therapeutic options include endovascular treatment, microsurgery or a combined approach. Surgical approaches are more complex if the lesions are located anteriorly and supplied by the anterior spinal artery (ASA). ASA can also vascularize shunts located on the posterior surface of the spinal cord either by transmedullary arteries, pial circumferential arteries or, if affecting the lower portions of the cord, by the anastomotic channels of the basket. Each of these vessels can be used for endovascular navigation to reach the shunts with good results if appropriate anatomical rules are followed. We describe here some technical considerations based on the anatomical analysis for the embolization of posterior spinal cord arteriovenous shunts vascularized by the anterior spinal artery.

5.
J Neurointerv Surg ; 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38914459

RESUMO

BACKGROUND: Flow diverting stents (FDS) have transformed the treatment of intracranial aneurysms; however, their metallic structure associated with their intra-luminal positioning hamper angiographic and clinical outcomes. Therefore, there is a need to develop FDS with optimized surfaces that reduce thrombogenicity while promoting the healing process and endothelialization. METHODS: P8RI, a peptide mimicking the CD31 protein, was previously developed and grafted onto Silk Vista (SV) FDS. P8RI-SV and bare-SV were used in vitro in a blood loop model to test their hemocompatibility using human whole blood and in vivo using the rabbit elastase model for optical coherence tomography (OCT) comparisons of neointimal formation at day 5 and day 28. RESULTS: After blood loop incubation, P8RI-SV showed significant reduction in fibrin binding (p=0.004) and platelet adhesion (p=0.041) compared with bare-SV. Similarly, derivative markers measured in blood, thromboxane B2 (platelet activation) and Thrombin-Antithrombin III complexes (coagulation activation), were also significantly reduced in the P8RI-SV group (both p=0.002). In vivo, complete or near-complete occlusion was reached in all aneurysms (n=6) at day 28. Excellent rate of stent-coverage ratio was obtained at day 5 (89.3% (79.1%-98.7%)) comparable to the observation at day 28 (91.8% (79.1%-100%); p=0.44). These rates were significantly higher compared with bare-SV at day 5 (77.8% (58.3%-86.8%); p<0.001) and at day 28 (67.7% (52.6%-88.9%); p<0.0001). CONCLUSION: In vitro results confirm enhanced hemocompatibility with a significant anti-thrombotic effect of the P8RI-SV. In vivo results provide evidence of rapid neo-intimal growth reaching near-complete tissue healing as early as day 5 in a rabbit model.

6.
J Neurointerv Surg ; 2024 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-38830670

RESUMO

BACKGROUND: Multiple studies and meta-analyses have described the technical and clinical outcomes in large cohorts of aneurysm patients treated with flow diverters (FDs). Variations in evaluation methodology complicate making comparisons among studies, hinder understanding of the device behavior, and pose an obstacle in the assessment of further advances in FD therapy. METHODS: A multidisciplinary panel of neurointerventionalists, imaging experts, and neuroradiologists convened with the goal of establishing consensus recommendations for the standardization of image analyses in FD studies. RESULTS: A standardized methodology is proposed for evaluating and reporting radiological outcomes of FD treatment of intracranial aneurysms. The recommendations include general imaging considerations for clinical studies and evaluations of longitudinal changes, such as neointimal lining and stenosis. They cover standards for classification of aneurysm location, morphology, measurements, as well as the assessment of aneurysm occlusion, wall apposition, and neck coverage. These reporting standards further define four specific braid deformation patterns: foreshortening, fish-mouthing, braid bump deformation, and braid collapse, collectively termed 'F2B2'. CONCLUSIONS: When widely applied, standardization of methods of measuring and reporting outcomes will help to harmonize the assessment of treatment outcomes in clinical studies, help facilitate communication of results among specialists, and help enable research and development to focus on specific aspects of FD techniques and technology.

7.
Artigo em Inglês | MEDLINE | ID: mdl-38575320

RESUMO

BACKGROUND: The effective treatment for acute ischemic stroke (AIS) patients with cervical internal carotid pseudo-occlusion (cICA-PO) requires comprehensive research on the safety and outcomes of endovascular thrombectomy (EVT). However, there is limited data available, highlighting the need for further research to ensure better treatment strategies and improve the quality of care for these patients. PURPOSE: This study aims to assess the management and outcomes in this population group compared to patients with true carotid occlusion. DATA SOURCES: Following the PRISMA guidelines, a comprehensive systematic review was conducted using PubMed, Embase, Web of Science, and Scopus from data base inception to November 2023. STUDY SELECTION: The size of the included studies ranged from 16 patients to 146 patients. Through the 4 full-text articles, a total of 259 patients were collected. We compared outcomes between patients with cICA-PO compared to patients with true carotid occlusions undergoing EVT due to AIS. We excluded studies with patients with carotid pseudo-occlusion without stroke, review articles, duplicate studies, overlapped data that included the same patients presented in another included study, case reports, case series with fewer than 5 patients, and meeting abstracts that did not contain the outcomes of interest. We did not pose any limitations regarding sample size or patients' characteristics. DATA ANALYSIS: We utilized the R statistical software (V.4.3.1; R package meta, R Foundation for Statistical Computing, Vienna, Austria) to conduct the analysis of all the data obtained. We calculated the odds ratio (OR) for binary variables, and the corresponding 95% confidence interval (CI). To synthesize the data, random-effect models, as well as forest plots were generated to visually represent the synthesis of the data. Additionally, we assessed heterogeneity using Cochran's Q and I2 tests. A P-value less than 0.05 for the Q statistic or I2 more than 50% suggests significant heterogeneity. Based on a small number of studies (less than 10), the assessment of publication bias could not be reliably performed. DATA SYNTHESIS: This meta-analysis encompassed data from 4 studies. Patients with cICA-PO and AIS who underwent EVT (n = 135) exhibited lower rates of functional independence (OR 0.35, 95% CI 0.20-0.61, p= <0.001) compared to patients with true occlusions (n = 103), as well as successful recanalization rates (OR 0.39, 95% CI 0.20-0.74, p=0.004). In addition, the cICA-PO group experienced higher mortality and sICH compared to the group with true carotid occlusions (OR 2.62, 95% CI 0.21-7.24, and OR 2.23, 95% CI 1.00-4.95, p= 0.049, respectively). LIMITATIONS: Individual patient data was not available. Studies were a retrospective design and some of the studies had small sample sizes. The included studies in our metaanalysis did not exclude patients with tandem occlusions which might influence the results of the comparison. CONCLUSIONS: As compared to patients with true carotid occlusion, the cICA-PO group with AIS undergoing EVT presented poor outcomes with lower functional independence and successful recanalization, as well as higher sICH and mortality rates.

9.
J Neurointerv Surg ; 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38538055

RESUMO

BACKGROUND: Retrospective studies suggest the superiority of first-line contact aspiration (CA) thrombectomy over stent-retriever (SR) in basilar artery occlusions (BAO). We aimed to investigate the impact of first-line mechanical thrombectomy per the occlusion level, considering differences in stroke etiology prevalence between proximal and distal BAO. METHODS: A retrospective, multicentric analysis of the Endovascular Treatment in Ischemic Stroke Registry (ETIS) included consecutive BAO patients treated from January 2016 to May 2022. Patients were categorized into SR (±aspiration) and CA alone groups. Occlusion levels were determined through digital subtraction angiography. Favorable clinical outcome was defined as 90-day modified Rankin Scale (mRS) 0-3. RESULTS: A total of 380 patients were analyzed (251 CA alone, 129 SR±aspiration). Globally, first-line SR showed lower recanalization rates (89.1% vs 94.8%, OR=0.29, 95% CI 0.16 to 0.53; p<0.001) and worse clinical outcomes (mRS 0-3: 46.0% vs 52.2%, OR=0.62, 95% CI 0.44 to 0.87; p=0.006) compared with CA. In proximal occlusions, SR was significantly associated with poorer clinical outcomes (mRS 0-3: 20.9% vs 37.1%; OR=0.40, 95% CI 0.19 to 0.83; p=0.014) despite similar recanalization rates. Conversely, in distal occlusions there was no difference in clinical outcomes although recanalization rates were higher with CA (modified Thrombolysis in Cerebral Infarction score (mTICI 2b/3): 97.7% vs 91.7%; OR=0.17, 95% CI 0.05 to 0.66; p=0.01). CONCLUSIONS: In our BAO population, CA demonstrated better angiographic outcomes in middle and distal occlusions and better clinical outcomes in proximal occlusions. This translated into better angiographic and clinical results in the global study population. Clinical results were particularly influenced by the negative impact of SR on 90-day mRS, independently of recanalization rates in proximal BAO.

10.
J Neuroradiol ; 51(2): 220-223, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37652262

RESUMO

BACKGROUND: The Contour Embolization Device (CED) is typically assessed using coiling angiographic outcomes. However, these scales do not address device-specific problematics. We evaluated the usability of the Bicêtre occlusion scale (BOS) with the CED. RESULTS: BOS scores can be analyzed as BOSS 0 = no residual flow, BOSS 1 = residual flow inside the CED but with complete neck-sealing, BOSS 2 = neck-remnant, BOSS 3 = aneurysm-remnant, BOSS 1 + 3 = contrast filling inside the device and aneurysmal sac without complete neck-sealing. CONCLUSION: BOS usage should be encouraged as it provides a more comprehensive assessment of the mechanism of CED occlusion, especially considering the potential prognostic value of the neck sealing assessment.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Angiografia Cerebral , Resultado do Tratamento , Estudos Retrospectivos , Stents
11.
J Neurointerv Surg ; 16(3): 302-307, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-37192788

RESUMO

BACKGROUND: WEB Shape Modification (WSM) over time is frequent after aneurysm treatment. In this study, we explored the relationship between histopathological changes and angiographic evolution over time in experimental aneurysms in rabbits treated with the Woven EndoBridge (WEB) procedure. METHODS: Quantitative WSM was assessed using flat-panel computed tomography (FPCT) during follow-up by calculating height and width ratio (HR, WR), defined as the ratio between either measurement at an index time point and the measurement immediately after WEB implantation. The index time point varied from 1 day to 6 months. HR and WR were evaluated with angiographic and histopathological assessments of aneurysm healing. RESULTS: Final HR of devices varied from 0.30 to 1.02 and final WR varied from 0.62 to 1.59. Altogether, at least 5% of HR and WR variations were observed in 37/40 (92.5%) and 28/40 (70%) WEB devices, respectively, at the time of final assessment. There was no significant correlation between complete or incomplete occlusion groups and HR or WR (p=0.15 and p=0.43). Histopathological analysis revealed a significant association between WR and aneurysm healing and fibrosis 1 month following aneurysm treatment (both p<0.05). CONCLUSION: Using longitudinal FPCT assessment, we observed that WSM affects both the height and width of the WEB device. No significant association was found between WSM and aneurysm occlusion status. Although presumably a multifactorial phenomenon, the histopathological analysis highlighted a significant association between width variations, aneurysm healing and fibrosis in the first month following aneurysm treatment.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Animais , Coelhos , Resultado do Tratamento , Aneurisma Intracraniano/terapia , Tomografia Computadorizada por Raios X , Angiografia Cerebral/métodos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Fibrose , Estudos Retrospectivos
12.
Neurosurgery ; 94(1): 183-192, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37728333

RESUMO

BACKGROUND AND OBJECTIVES: The Woven EndoBridge (WEB) device has been increasingly used to treat wide-neck aneurysms showing a safe and effective profile, but a relatively high number of thromboembolic events (TEEs) have been reported with such treatment. We aimed to evaluate the incidence and management of TEEs and possible predictive factors related to WEB embolization of ruptured and unruptured intracranial aneurysms. METHODS: A single-center database with consecutive aneurysms treated with a WEB device between July 2012 and May 2022 was reviewed for intraoperative and delayed TEEs. Univariate and multivariable analyses were used to determine factors associated with TEEs. RESULTS: A total of 266 independent aneurysms were treated with WEB devices in 245 patients (mean age 55.78 ± 11.64 years, 169 (63.5%) females, 80 (30%) ruptured). The overall rate of TEEs is 13% (35/266), including 8.7% intraoperative. Symptomatic TEEs with clinical sequelae at a 3-month follow-up are reported to be 2.6% (7/266) with no TEE-related mortality. Both the replacement of a WEB device during the procedure (adjusted odds ratio = 2.61, 95% CI 1.24-5.49; P = .01) and ruptured aneurysms (adjusted odds ratio = 2.74, 95% CI 1.31-5.7; P = .007) were independent predictors of TEEs. A case-by-case management of intraprocedural TEE is also presented; tirofiban was successfully used in most cases of this cohort. CONCLUSION: In this study, we demonstrated that ruptured aneurysms and WEB device replacement during the procedure were independent predictive factors for TEEs. As a result, making the correct choice of WEB is crucial for improving treatment outcomes. Moreover, with proper medical management of TEEs, minimal morbidity and no mortality could be achieved, which reinforces the safety of the technique.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Tromboembolia , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Masculino , Incidência , Estudos Retrospectivos , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Aneurisma Intracraniano/epidemiologia , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/complicações , Aneurisma Roto/epidemiologia , Aneurisma Roto/terapia , Aneurisma Roto/complicações , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Embolização Terapêutica/efeitos adversos
13.
J Neurointerv Surg ; 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37914392

RESUMO

BACKGROUND: Intrasaccular flow disruption is an endovascular approach for the treatment of wide-neck aneurysms and, more specifically, wide-neck bifurcation aneurysms, which are challenging to treat with previously developed technologies. The Woven EndoBridge (WEB) device has demonstrated its efficacy and safety, for both unruptured and ruptured aneurysms. METHODS: The CLEVER study was an observational, multicenter, prospective study conducted in 17 European investigational sites using the WEB 17 device, for the treatment of ruptured and unruptured aneurysms. The study objective was to provide safety and efficacy data on the WEB 17 device in the treatment of wide-neck bifurcation aneurysms. Imaging results were assessed independently by a Corelab and adverse events adjudicated by a Clinical Event Adjudicator. This analysis reports procedural results and safety at 30 days and 12 months. RESULTS: A total of 163 patients (mean age 58.1 years; 68.1% women) with 103 unruptured aneurysms and 60 ruptured aneurysms were enrolled. Most aneurysms were located on the anterior communicating artery (ACom) (37.4%) or the middle cerebral artery (MCA) bifurcation (30.1%). Aneurysm widths ranged from 2.0-9.2 mm, and the mean sac width was 5.0 mm. The WEB procedure was successfully completed in 163 patients (100%). At the 12-month follow-up, major stroke events occurred in 3 of 163 patients (1.8%), and no device-related mortality was observed. CONCLUSION: Endovascular treatment of ruptured and unruptured wide-neck bifurcation aneurysms using WEB 17 is safe, with a low complication rate and no device-related mortality. In particular, none of the ruptured aneurysms bled again up to 1 year of follow-up. TRIAL REGISTRATION NUMBER: NCT03844334.

14.
J Neuroradiol ; 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37858720

RESUMO

BACKGROUND: The Low profile visualized intraluminal support (LVIS)/LVIS Jr is a self-expanding braiding stent for the treatment of intracranial aneurysm. This study is to determine the safety and effectiveness of the LVIS/LVIS Jr for the treatment of intracranial aneurysms in a real-world setting. METHODS: This prospective, observational, multicenter study enrolled patients with unruptured, ruptured and recanalized intracranial aneurysms treated with the LVIS stents, between February 2018 to December 2019. Primary endpoint was the cumulative morbidity and mortality rate (CMMR) assessed at 12 months follow-up (FU). RESULTS: A total of 130 patients were included (62.3 % women, mean age 55.9 ± 11.4) on an intention-to-treat basis. Four patients (3.1 %) had 2 target aneurysms; 134 total aneurysms were treated. The aneurysms were mainly located on the middle cerebral artery (41/134; 30.6 %) and the anterior communicating artery (31/134; 23.1 %). The CMMR at 1 year linked to the procedure and/or device was 4.6 % (6/130). The overall mortality was 1.5 % (2/130), none of these deaths adjudged as being linked to the procedure and/or device. All aneurysms (134/134, 100 %) were successfully treated with LVIS stent and/or other devices. At a mean FU of 16.8 months post-procedure, complete/nearly complete occlusion was achieved in 112 aneurysms (92.6 %), and only 3 patients (2.5 %) required aneurysm retreatment. CONCLUSION: This study provides evidence that the LVIS/LVIS Jr devices are safe and effective in the treatment of complex intracranial aneurysms, with very high rates of adequate occlusion at FU. These angiographic results are stable over time with an acceptable complication rate. TRIAL REGISTRATION: ClinicalTrial.gov under NCT03553771.

15.
J Neurointerv Surg ; 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37798103

RESUMO

BACKGROUND: Aneurysm location is a key element in predicting the rupture risk of an intracranial aneurysm. A common impression suggests that pure ophthalmic aneurysms are under-represented in ruptured intracranial aneurysms (RIAs). The purpose of this study was to specifically evaluate the risk of rupture of ophthalmic aneurysms compared with other aneurysm locations. METHODS: This multicenter study compared the frequency of ophthalmic aneurysms in a prospective cohort of RIAs admitted to 13 neuroradiology centers between January 2021 and March 2021, with a retrospective cohort of patients with unruptured intracranial aneurysms (UIAs) who underwent cerebral angiography at the same neuroradiology centers during the same time period. RESULTS: 604 intracranial aneurysms were included in this study (355 UIAs and 249 RIAs; mean age 57 years (IQR 49-65); women 309/486, 64%). Mean aneurysm size was 6.0 mm (5.3 mm for UIAs, 7.0 mm for RIAs; P<0.0001). Aneurysm shape was irregular for 37% UIAs and 73% RIAs (P<0.0001). Ophthalmic aneurysms frequency was 14.9% of UIAs (second most common aneurysm location) and 1.2% of RIAs (second least common aneurysm location; OR 0.07 (95% CI 0.02 to 0.23), P<0.0001). CONCLUSIONS: Ophthalmic aneurysms seem to have a low risk of rupture compared with other intracranial aneurysm locations. This calls for a re-evaluation of the benefit-risk balance when considering preventive treatment for ophthalmic aneurysms.

16.
J Neuroradiol ; 2023 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-37634579

RESUMO

BACKGROUND AND PURPOSE: New coated flow diverters (FDs) claim antithrombotic properties and increased arterial wall integration. The aim of this study is to compare in vivo endothelial coverage of coated and uncoated FD in the context of different antiplatelet regimens. METHODS: Different FDs (Silk Vista - SV, Pipeline with Shield technology - PED shield and Surpass Evolve - SE) were implanted in the aorta of rabbits, all 3 in each animal with 3 different antiplatelet regimens: no antiplatelet therapy, aspirin alone, or aspirin and ticagrelor. Four weeks after FD implantation, angiography, flat-panel CT, and optical coherence tomography (OCT) were performed before harvesting the aorta. Extensive histopathology analyses were performed including environmental scanning electron microscopy (ESEM), multiphoton microscopy (MPM) and histological staining with qualitative and/or quantitative assessment of device coverage. RESULTS: All 23 FDs that were implanted remained patent without hyperplasia. Qualitative stent coverage assessment revealed that there were no statistically significant differences between the FD groups (p = 0.19, p = 0.45, p = 0.40, and p = 0.84 for OCT, ESEM, MPM and histology, respectively). Quantitative neointimal measurement of histological sections also showed similar results in all 3 FD groups (p = 0.70). However, there were significant differences between the 3 groups of antiplatelet regimens (p = 0.07) with a higher rate in the no antiplatelet group (p = 0.05 versus aspirin alone and p = 0.03 versus aspirin and ticagrelor). CONCLUSION: Our study provides evidence that FD integration into the arterial wall is similar with coated (PED shield) and uncoated devices (SV, SE), regardless of the antiplatelet regimen. FD integration with specific surface coverage should be promoted. TRIAL REGISTRATION: APAFIS #2022011215518538.

17.
J Neurointerv Surg ; 2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37491380

RESUMO

BACKGROUND: Recanalization of coiled aneurysms remains unresolved. To limit aneurysm recanalization after embolization with coils, we propose an innovative approach to optimize aneurysm healing using fucoidan-coated coils. OBJECTIVE: To evaluate the short-term efficacy and long-term safety of the new coil system with conventional angiography, histology, and multiphoton microscopy for follow-up of fibrosis and neointima formation. METHODS: We conducted a feasibility study on rabbit elastase-induced aneurysms. Embolization was carried out with bare platinum coils, fucoidan-coated coils, or dextran-coated coils. Aneurysms were controlled after 1 month by digital subtraction angiography (DSA). Aneurysm samples were collected and processed for histological analysis. Aneurysm healing and fibrosis were measured by quantifying collagen according to the histological healing score by combining standard light microscopy and multiphoton imaging. We divided 27 rabbits into three groups: bare platinum group, fucoidan group, and dextran group as controls. RESULTS: Angiographic grading showed a trend toward less recanalization in the fucoidan group, although there were no significant differences among the three groups (P=0.21). Histological healing was significantly different according to the presence of more collagen in the neck area of aneurysms in the fucoidan group versus the bare platinum group (P=0.011), but not in the dextran group. Histological index was significantly better at the aneurysm neck in the fucoidan group than in the bare platinum group (P=0.004). Collagen organization index was also significantly better in the fucoidan group than in the bare platinum group (P=0.007). CONCLUSION: This proof-of-concept study demonstrated the feasibility and efficacy of treatment with fucoidan-coated coils to improve aneurysm healing. The results in this rabbit in vivo model showed that fucoidan-coated coils have the potential to improve healing following endovascular treatment.

18.
J Neurol ; 270(11): 5493-5501, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37515733

RESUMO

BACKGROUND: Hemorrhagic transformation (HT) is an uncommon complication of posterior circulation acute ischemic stroke (PCS) compared to anterior circulation stroke. Nevertheless, it remains a major concern especially following reperfusion therapy. This study aimed at identifying potential predictive factors associated with HT in PCS. METHODS: Consecutive patients, from a multicenter cohort, with PCS treated by IVT or EVT or the combination of both, were included from December 2015 to May 2019. The European Cooperative Acute Stroke Study criteria was used to identify HT. Potential risk factors were analyzed using univariate and multivariable testing models. RESULTS: A total of 96 patients were included in our study. Median age was 66 (57-83) years, 54 patients (56%) were male and median baseline NIHSS was 8 (4-14). 77 patients (80%) received IVT and 54 patients (56%) benefited from EVT. HT occurred in 19 patients (20%), while sHT occurred in 3 patients (3%). HT was found to be associated with poor functional status at 3 months in univariate analysis (p = 0.0084). Multivariable analysis confirmed that higher baseline NIHSS (OR 1.1008; 95% CI [1.0216-1.1862]; p = 0.0117) and lobar topography of ischemia (OR 4.4275; 95% CI [1.3732-14.2753]; p = 0.0127) were independent predictors of the occurrence of HT. DISCUSSION: HT is associated with increased morbidity in patients with PCS; higher NIHSS and lobar ischemia were independent predictors of HT in our population. Easy-to-use predictive markers may help to tailor therapeutic management of patients with PCS.

19.
Eur Heart J Cardiovasc Imaging ; 24(11): 1518-1527, 2023 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-37194564

RESUMO

AIMS: We aim to evaluate the clinical relevance and the prognostic value of arterial and venous renal Doppler in acute decompensated precapillary pulmonary hypertension (PH). METHODS AND RESULTS: The renal resistance index (RRI) and the Doppler-derived renal venous stasis index (RVSI) were monitored at admission and on Day 3 in a prospective cohort of precapillary PH patients managed in intensive care unit for acute right heart failure (RHF). The primary composite endpoint included death, circulatory assistance, urgent transplantation, or rehospitalization for acute RHF within 90 days following inclusion. Ninety-one patients were enrolled (58% female, age 58 ± 16 years). The primary endpoint event occurred in 32 patients (33%). In univariate logistic regression analysis, variables associated with RRI higher than the median value were non-variable parameters (age and history of hypertension), congestion (right atrial pressure and renal pulse pressure), cardiac function [tricuspid annular plane systolic excursion (TAPSE) and left ventricular outflow tract- velocity time integral], systemic pressures and NT-proBNP. Variables associated with RVSI higher than the median value were congestion (high central venous pressure, right atrial pressure, and renal pulse pressure), right cardiac function (TAPSE), severe tricuspid regurgitation, and systemic pressures. Inotropic support was more frequently required in patients with high RRI (P = 0.01) or high RVSI (P = 0.003) at the time of admission. At Day 3, a RRI value <0.9 was associated with a better prognosis after adjusting to the estimated glomerular filtration rate. CONCLUSION: Renal Doppler provides additional information to assess the severity of patients admitted to the intensive care unit for acute decompensated precapillary PH.


Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Hipertensão , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Masculino , Hipertensão Pulmonar/diagnóstico por imagem , Prognóstico , Relevância Clínica , Estudos Prospectivos , Hipertensão/complicações , Função Ventricular Direita
20.
J Neuroradiol ; 50(5): 518-522, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36868371

RESUMO

BACKGROUND: Safety and efficacy of the WEB (Woven EndoBridge) device have been extensively evaluated in several good clinical practice studies. Nonetheless, the WEB had several structural evolutions overtime up to the fifth generation WEB device (WEB17). Here, we tried to understand how this may have modified our practices and enlarged our indications for its use. METHODS: We retrospectively analyzed data from all patients with aneurysms treated (or intended to be treated) with a WEB at our institution between July 2012 and February 2022. The time frame was split in two periods: before and after the arrival of the WEB17 in our center (February 2017). RESULTS: 252 patients with 276 wide-necked aneurysms were included; 78 aneurysms (28.2%) were ruptured. Successful embolization with a WEB device was achieved in 263/276 aneurysms (95.3%). With the availability of WEB17, treated aneurysms were significantly smaller (8.2 mm versus 5.9 mm, p<0.001) and off-label location significantly increased (4.4% versus 17.3%, p = 0.02) with an increase of sidewall aneurysm (4.4% versus 11.6%, p = 0.06). Also, WEB were more significantly oversized (1.05 versus 1.11, p<0.01). Adequate and complete occlusion rates increased constantly during the two periods (54.8% versus 67.5%, p = 0.08 and 74.2% versus 83.7%, p = 0.10, respectively). The proportion of ruptured aneurysms slightly increased between the two periods (24.6% versus 29.5%, p = 0.44). CONCLUSIONS: Over the first decade of its availability, the WEB device usage shifted towards smaller aneurysms and broader indications, including ruptured aneurysms. The oversizing strategy also became the standard of practice for WEB deployment in our institution.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Resultado do Tratamento , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Estudos Retrospectivos , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA