Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
J Clin Ultrasound ; 52(8): 1129-1139, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39001677

RESUMO

At the quadrangular joint (QAJ) of the carpus, a rare bony protuberance called carpal boss (CB) may occur. This bone abnormality may be due to osteophytes development or os styloideum. Symptomatic patients may complain pain, swelling, and restrictions in hand motion. These symptoms result from joint degenerative-inflammatory changes, development of ganglion cyst/bursitis, or tendons pathology. Correct diagnosis and appropriate management can be achieved through high-resolution ultrasonography (HR-US). The purpose of this review is to define the pathology spectrum around and within the QAJ in CB. The role of HR-US is highlighted and the standard technique for the QAJ assessment is described.


Assuntos
Ultrassonografia , Humanos , Ultrassonografia/métodos , Ossos do Carpo/diagnóstico por imagem , Articulações do Carpo/diagnóstico por imagem
2.
J Pers Med ; 14(6)2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38929881

RESUMO

BACKGROUND: This study aims to characterize the clinical impact of endovascular treatment in Chronic Pelvic Pain (CPP) patients due to Pelvic Congestion Syndrome (PCS) and to assess the diagnostic value of surface electromyography (sEMG) studies of pelvic floor musculature (PFM) in PCS patients pre- and post-endovascular treatment. Between January 2019 and July 2023, we studied consecutive patients who were referred for interventional radiology assessment and treatment to a tertiary trauma care hospital, had evidence of non-obstructive PCS from Magnetic Resonance Imaging (MRI), had sEMG of PFM and who had undergone endovascular treatment. The primary outcome was clinical, defined as a change in symptom severity after endovascular treatment. The secondary outcome was a difference in the sEMG values pre- and post-endovascular therapy. RESULTS: We included 32 women (mean age 38 years). CPP was the leading symptom in 100% patients, followed by dysmenorrhea (75%) and post-coital pain (68.7%). Endovascular therapy included ovarian vein embolization in 28 patients (87.5%) and internal iliac vein embolization in only 2 patients (6.2%). After a median of 8 (range 6-10) months from endovascular treatment, 29 (90%) of patients reported an improvement of the main symptoms, and 15 (46%) were symptom-free. The sEMG values did not show a statistical difference pre- and post-PCS endovascular treatment. CONCLUSIONS: Endovascular treatment appeared to be highly effective in CPP due to PCS and was associated with a low rate of complication. sEMG study could be useful in revealing alterations of PFM electrophysiology, but a difference pre- and post-embolization in PCS patients was not demonstrated.

3.
J Clin Ultrasound ; 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38822664

RESUMO

Aortic dissection (AD) is a rare and potentially fatal condition that may be diagnosed late. During an emergency or elective abdominal ultrasound (US) examination, when going to evaluate the abdominal aorta for other reasons, it may happen that we find ourselves suspecting an AD. It is therefore important to know the US characteristics of this pathology to avoid wrong or missed diagnoses. Here, we present our practical experience regarding the application of US in the study of the abdominal aorta, which allowed us on several occasions to find an unexpected dissection in patients brought to our attention for other reasons.

4.
J Ultrasound Med ; 43(8): 1489-1499, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38708914

RESUMO

OBJECTIVES: To investigate the role of high-resolution ultrasound (HR-US) in the initial and differential diagnosis of the Odontogenic Cutaneous Sinus Tract (OCST) in a multicentric setting. METHODS: Skin HR-US examinations of OCSTs performed between January 2019 and June 2023 at different Institutions were retrospectively reviewed. Epidemiological and clinical data (age, gender, location of the skin lesion, causative tooth, and the clinical suspicion) as well as HR-US imaging findings (morphology and length of the sinus tract, Doppler signal, and cortical bone interruption of maxilla or mandible) were collected. US examinations were performed by expert radiologists using a high-performance US scanner, employing a high-frequency linear probe (15 MHz or higher frequencies). In only one patient the HR-US exam was integrated with strain elastography (SE). RESULTS: Sixteen patients were enrolled with a median age of 37.6 years (range 16-70 years). The most frequent clinical suspicion was epidermal cyst, while OCST was suspected in only two cases. In all cases, HR-US depicted the sinus tract as a nodular, triangular or "champignon-shaped" lesion in the subcutaneous layer, which continued with a slightly tortuous band structure, up to the focally interrupted cortical bone plate. Furthermore, color Doppler evaluation showed color signals around and/or within the lesion, expression of inflammation. On SE, the sinus tract showed a hard pattern, due to fibrous and granulomatous tissue. CONCLUSIONS: HR-US, thanks to its high spatial resolution, allows the evaluation of OCST, and play a crucial diagnostic role, mainly when the clinical suspicious is different.


Assuntos
Ultrassonografia , Humanos , Masculino , Feminino , Adolescente , Pessoa de Meia-Idade , Adulto , Estudos Retrospectivos , Adulto Jovem , Idoso , Ultrassonografia/métodos , Diagnóstico Diferencial , Cistos Odontogênicos/diagnóstico por imagem , Fístula Cutânea/diagnóstico por imagem
5.
CVIR Endovasc ; 7(1): 50, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38789727

RESUMO

PURPOSE: The purpose of this systematic review and meta-analysis was to evaluate the safety, technical, and clinical effectiveness of percutaneous Transarterial Embolization (TAE) in treating spontaneous retroperitoneal hematomas as well as assess treatment outcomes in patients who underwent target or empirical embolization. MATERIALS AND METHODS: Through the PubMed, Embase, and Google Scholar databases, an extensive search was performed in the fields of spontaneous retroperitoneal hematomas treated with transcatheter arterial embolization. We collected pooled data on 141 patients from 6 separate articles selected according to the inclusion and exclusion criteria. RESULTS: Technical success rate was 100% in all six studies, for both targeted and empirical embolization. The clinical success rate varied from 56.3 to 89.5%. The total number of complications related to the embolization procedure was 10 events out of 116 procedures analyzed. Empirical or empirical embolization was performed in three studies, where the source of active bleeding was not evident during DSA. A meta-analysis compared the rebleeding rates between targeted and empirical embolization groups. The odds ratio from pooled data from the three assessed studies (72 patients) showed no significant difference in rebleeding rates after empirical TAE compared with targeted TAE. CONCLUSIONS: TAE is a safe, effective, and potentially life-saving procedure for the treatment of life-threatening spontaneous retroperitoneal hematomas. Empirical and targeted TAE procedures demonstrate a relatively low risk of complications, compared to the high technical and relatively high clinical success rates.

6.
J Pers Med ; 14(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38672992

RESUMO

The liver is the second most common solid organ injured in blunt and penetrating abdominal trauma. Non-operative management (NOM) has become the standard of care for liver injuries in stable patients, where transarterial embolization (TAE) represents the main treatment, increasing success rates and avoiding invasive surgical procedures. In hemodynamically (HD) unstable patients, operative management (OM) is the standard of care. To date, there are no consensus guidelines about the endovascular treatment of patients with HD instability or in ones that responded to initial infusion therapy. A review of the literature was performed for published papers addressing the outcome of using TAE as the primary treatment for HD unstable/transient responder trauma liver patients with hemorrhagic vascular lesions, both as a single treatment and in combination with surgical treatment, focusing additionally on the different definitions used in the literature of unstable and transient responder patients. Our review demonstrated a good outcome in HD unstable/transient responder liver trauma patients treated with TAE but there still remains much debate about the definition of unstable and transient responder patients.

7.
Medicina (Kaunas) ; 60(2)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38399625

RESUMO

Ureteral involvement by a tumor is common, and both partial and complete obstructions can result in symptoms that are distressing and debilitating, especially in cancer patients for whom the resection of the primary tumor is not considered an option. Maintaining ureteric patency in these patients is a challenge. In addition, in cases where a patient has undergone nephroureterectomy due to primary transitional cell cancer, it becomes necessary to decompress the urinary tract to preserve the contralateral kidney from irreversible damage. This is possibly due to ureteral stenting, both retrograde and anterograde, and percutaneous nephrostomy (PCN). Since imaging plays an important role in the routine monitoring of stents, their more and more increasing use requires radiologists to be familiar with these devices, their correct position, their potential complications, and their consequences. The aim of this review is to offer a comprehensive review of the imaging features of some urinary stents and to show the complications encountered in cancer patients as a direct consequence of an invasive diagnostic or therapeutic procedure. Specifically, we focus on ureteral stents and PCN.


Assuntos
Nefrostomia Percutânea , Ureter , Obstrução Ureteral , Neoplasias da Bexiga Urinária , Humanos , Obstrução Ureteral/diagnóstico por imagem , Obstrução Ureteral/etiologia , Obstrução Ureteral/cirurgia , Nefrostomia Percutânea/efeitos adversos , Nefrostomia Percutânea/métodos , Ureter/diagnóstico por imagem , Ureter/cirurgia , Stents/efeitos adversos , Estudos Retrospectivos
8.
CVIR Endovasc ; 7(1): 11, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38221592

RESUMO

BACKGROUND: This retrospective multicentric study aims to report on technical safety and effectiveness of pseudoaneurysms embolization with glue (N-butyl cyanoacrylate) adopting a percutaneous direct puncture approach. RESULTS: Fifty-four patients data were collected from five centers. All patients at the time of treatment presented with unruptured PAs and were hemodynamically stable. True aneurysms and lesions treated with embolics other than glue were excluded. Pseudoaneurysms diagnosis was based on CT and anamnestic data; initial investigation with digital-subtracted arteriography was acquired in all cases; then, percutaneous embolizations were performed in the angio-suite (ultrasound, fluoroscopy, ConeBeam CT guidance) or in CT. Technical success was considered as complete pseudoaneurysm embolization at final imaging with sole percutaneous strategy, without need for additional endovascular embolization. Clinical success was intended as pseudoaneurysm resolution within one week follow-up with stabilization or restored clinical conditions. Pseudoaneurysms origins were traumatic (57.4%), inflammatory (24.1%) or spontaneous (18.5%); 39 patients (72.2%) were symptomatic, presenting with pain and/or pulsatile mass. Mean lesions diameter was 19.3 mm (range: 7-30); pseudoaneurysms were located in abdomen (48.1%), limbs (42.6%) and thorax (9.3%). Coagulation function was impaired in 16.6% and 48.1% was under antiplatelets/anticoagulation therapy. In 16.6% the percutaneous approach followed previous treatments failure. The image-guidance modality for percutaneous puncture was most often ultrasound combined with fluoroscopy (38%). Clinical success was obtained in all patients while technical success occurred in 94.4% because 3 patients required an additional endovascular embolization. Complications were registered in 14.8%, all of low grade without clinical sequelae neither prolonged recovery (7 non target embolizations, 1 post-embolization syndrome). CONCLUSIONS: In this study, pseudoaneurysms embolization with glue via percutaneous direct puncture was safe and effective with a low rate of minor complications.

9.
J Cardiovasc Surg (Torino) ; 65(1): 49-63, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38037721

RESUMO

The objective of these Guidelines is to provide recommendations for the classification, indication, treatment and management of patients suffering from aneurysmal pathology of the visceral and renal arteries. The methodology applied was the GRADE-SIGN version, and followed the instructions of the AGREE quality of reporting checklist. Clinical questions, structured according to the PICO (Population, Intervention, Comparator, Outcome) model, were formulated, and systematic literature reviews were carried out according to them. Selected articles were evaluated through specific methodological checklists. Considered Judgments were compiled for each clinical question in which the characteristics of the body of available evidence were evaluated in order to establish recommendations. Overall, 79 clinical practice recommendations were proposed. Indications for treatment and therapeutic options were discussed for each arterial district, as well as follow-up and medical management, in both candidate patients for conservative therapy and patients who underwent treatment. The recommendations provided by these guidelines simplify and improve decision-making processes and diagnostic-therapeutic pathways of patients with visceral and renal arteries aneurysms. Their widespread use is recommended.


Assuntos
Aneurisma , Embolização Terapêutica , Humanos , Artéria Renal/diagnóstico por imagem , Radiologia Intervencionista , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Embolização Terapêutica/efeitos adversos , Itália
10.
J Ultrasound ; 27(1): 179-184, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37162728

RESUMO

AIMS: This study aims to report on safety and effectiveness of glue embolization of acute hemorrhages performed by US-guided percutaneous direct puncture, in patients where the standard endovascular approach is technically unfavourable. METHODS: In this single center retrospective analysis, patients affected by traumatic or non traumatic acute hemorrhages were treated with glue embolization technically performed by US-guided direct puncture. Patients suffered from active bleeding detected at contrast-enhanced Computer Tomography and confirmed at Digital Subtracted Arteriography, with concomitant hemoglobin drop and blood pressure reduction. Six patients were reviewed; hemorrhages occurred in liver parenchima (1), gallbladder (1) and lower limbs (4). Bleedings etiologies were post-traumatic (5) and inflammatory (1); four had extraluminal blushes while 2 were pseudoaneurysms. In five cases (4 limbs and 1 hepatic bleedings) the direct-puncture approach was adopted because of technically unfavourable vascular anatomy for superselective embolization; in one case (cystic artery pseudoaneurysm), an endovascular embolization would entail a high risk of gallbladder ischemia because of its terminal arterial supply. Technical success was defined disappearance of bleeding signs at last arteriography; clinical success was considered stabilization and/or improvement of hemoglobin values and arterial pressure without additional interventions. RESULTS: Both technical and clinical successes were obtained in 100% of the cases without major complications. No needle occlusion occurred during glue injection. CONCLUSIONS: In this study percutaneous US-guided embolization by direct puncture was a safe and effective approach to manage acute bleedings; it could be considered as an alternative in patients with unfavourable vascular anatomy for the standard catheter-directed endovascular embolization.


Assuntos
Embolização Terapêutica , Hemorragia , Humanos , Estudos Retrospectivos , Hemorragia/diagnóstico por imagem , Hemorragia/etiologia , Hemorragia/terapia , Artérias , Hemoglobinas
12.
Radiol Med ; 128(11): 1429-1439, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37715849

RESUMO

PURPOSE: This study aims to evaluate the diagnostic value of pelvic arteriography in patients with pelvic ring fractures and associated large hematomas, in both cases of positive or negative findings of contrast agent extravasation at emergency CT; in those patients with positive DSA subsequently treated with embolization, correlations with clinical-radiological parameters were investigated. MATERIALS AND METHODS: In this single-center retrospective study, patients with acute blunt pelvic trauma showing at CT pelvic ring fractures with associated large (> 3 cm) hematoma, with or without signs of arterial bleeding, were investigated with DSA. Technical success was considered radiographic bleeding control with disappearance of angiographic bleeding; clinical success was defined as clinical bleeding control hemodynamically stable, before applying other surgical maneuvers. Pelvic ring fractures were evaluated according to Tile classification system. RESULTS: One hundred and fifty-seven patients, mean age 54years, were analyzed. 70.7% had polytrauma; 14.6% patients assumed antiplatelets and/or anticoagulation therapy. False-negative and false-positive rates at CT were 29.6% and 27.1%, respectively. Polytrauma and B3/C1 Tile pattern fractures were significantly associated with bleeding signs at DSA. Seventy-two patients required embolization: 52.8% showed direct signs of DSA bleeding; among these, technical and clinical successes were 88.8% and 81.9%, respectively. CONCLUSIONS: In this study, patients with pelvic ring fractures and concomitant hematomas > 3 cm, with or without contrast extravasation at CT, have been examined in depth with DSA focusing on both direct and indirect angiographic signs of bleeding, finding polytrauma and Tile fracture patterns B3/C1 predictive factors for arterial hemorrhage detection at DSA despite negative CT findings.


Assuntos
Embolização Terapêutica , Fraturas Ósseas , Traumatismo Múltiplo , Ferimentos não Penetrantes , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Angiografia , Hematoma/diagnóstico por imagem , Hematoma/etiologia , Hematoma/terapia , Hemorragia/diagnóstico por imagem , Hemorragia/etiologia , Hemorragia/terapia , Extravasamento de Materiais Terapêuticos e Diagnósticos/diagnóstico por imagem , Extravasamento de Materiais Terapêuticos e Diagnósticos/terapia , Fraturas Ósseas/complicações , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/terapia , Ferimentos não Penetrantes/complicações , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/terapia
13.
Medicina (Kaunas) ; 59(7)2023 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-37512071

RESUMO

Background: Paratesticular tumors (PTs) are very uncommon, accounting for almost 5% of intrascrotal tumors. Of these, adenomatoid tumors (ATs) represent about 30% and most frequently arise in the tail of the epididymis. Ultrasound (US) examination is the first-choice imaging method employed for the evaluation of the scrotum. Unfortunately, there are no specific US-imaging features useful for distinguishing an AT from a malignant lesion. To increase diagnostic accuracy and confidence, new sonographic techniques have incorporated real-time tissue elastography (RTE) under the assumption that malignant lesions are "harder" than benign lesions. Case report: In our paper, we describe a very rare case of a 60-year-old patient with a giant paratesticular mass mimicking malignancy when examined using RTE, i.e., it was stiffer than the surrounding tissue (a hard pattern), which, upon histologic examination, was identified as an AT. Discussion: Our case underscores that there is also a significant overlap between different types of scrotal lesions when RTE is used for examination. Thus, if a PT is found, the imaging approach should always be supplemented with more definitive diagnostic methods, such as FNAC or FNAB, which are the only diagnostic methods capable of leading to a certain diagnosis. Conclusions: Alongside underlining the importance of pre-operative imaging for making correct diagnoses and selecting the correct therapy, we wish to draw our readers' attention to this report in order to demonstrate the clinical implications of a giant AT presenting as stiff lesions when examined using SE.


Assuntos
Tumor Adenomatoide , Técnicas de Imagem por Elasticidade , Neoplasias dos Genitais Masculinos , Masculino , Humanos , Pessoa de Meia-Idade , Tumor Adenomatoide/diagnóstico por imagem , Tumor Adenomatoide/patologia , Escroto/diagnóstico por imagem , Escroto/patologia , Neoplasias dos Genitais Masculinos/diagnóstico por imagem , Neoplasias dos Genitais Masculinos/patologia , Epididimo/patologia
14.
Cardiovasc Intervent Radiol ; 46(3): 400-405, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36746789

RESUMO

PURPOSE: This paper describes the initial experience with a PTFE-covered microplug to perform extravascular embolizations in patients with iatrogenic biliary leaks. MATERIALS AND METHODS: A retrospective multicenter analysis has been conducted on seven patients. All were symptomatic for abdominal pain and had an abdominal drainage adjacent to the supposed site of leakage. The biliary output of the drainage was monitored daily. Biliary leak etiology was iatrogenic: four after laparoscopic cholecistectomy for gallstones, one after explorative laparotomy for pancreas head adenocarcinoma with concomitant cholecistectomy for gallstones, and two after long-standing internal-external right biliary drainage for cholangiocarcinoma. In four cases leakage sourced from cystic duct stump, in one from an aberrant bile duct and in two from bilio-cutaneous fistula. Technical success was considered leak resolution at the last cholangiography. Clinical success was defined improvement in the clinical conditions together with progressive resolution of the biliary output from the abdominal drainage until removal. RESULTS: Technical and clinical successes were 100%. A 5 mm microplug was adopted in five cases of post-cholecistectomy leaks. A 3 mm microplug and a 9 mm microplug were deployed in the two cases of peripheral leaks related to bilio-cutaneous fistulas. In three patients additional embolics (coils in two cases; spongel slurry in one case) were required. Minor complications occurred in three patients. CONCLUSION: This initial experience on seven patients with iatrogenic biliary leaks demonstrated that percutaneous transhepatic PTFE-covered microplug embolization is technically feasible and clinically effective to achieve leak resolution. Future researches with larger samples are needed to confirm these findings.


Assuntos
Doenças Biliares , Cálculos Biliares , Humanos , Cálculos Biliares/complicações , Doenças Biliares/etiologia , Ductos Biliares/cirurgia , Politetrafluoretileno , Doença Iatrogênica , Estudos Retrospectivos , Drenagem , Complicações Pós-Operatórias/cirurgia
15.
J Clin Ultrasound ; 51(5): 845-847, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36753407

RESUMO

De Quervain's tenosynovitis involves the first of the six dorsal compartments of the wrist, which contains the abductor pollicis longus (APL) and extensor pollicis brevis (EPB) tendons. It seems to be associated with female sex (F:M = 10:1), middle age (30-50 years) and activities involving repetitive hand and wrist motions such as typing, piano playing or repetitively lifting children head, such as in postpartum females (hence the term "baby wrist" or "mommy wrist"). Aim of this paper was to illustrate high-resolution ultrasound (US) features of the DQD by describing a well-documented case that occurred in a "new dad" taking care of his babe. Hence, firstly in literature we could refer to this condition with the term of "daddy wrist".


Assuntos
Tenossinovite , Punho , Pessoa de Meia-Idade , Criança , Humanos , Feminino , Adulto , Punho/diagnóstico por imagem , Tenossinovite/diagnóstico por imagem , Articulação do Punho/diagnóstico por imagem , Tendões/diagnóstico por imagem , Antebraço
16.
J Ultrasound ; 26(1): 49-58, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36705852

RESUMO

The breast ultrasound (US) field-of-view (FOV) includes glandular parenchyma as well as tissues located anterior to and posterior to it, up to pleural line. For that, it is possible to incidentally identify lesions unrelated to breast parenchyma during screening or diagnostic US; sometimes a palpable lump may be the reason of the imaging exam. Furthermore, abnormality related to chest wall are easier and more accurate detected after mastectomy. Hence, radiologists should know the US appearance of lesions which may develop from all tissues present in this region and displayed in the US FOV, without focusing only on glandular abnormalities while performing the exam. This is the second of a two-part series on non-glandular breast lesions; in detail, part two provide an overview of US appearance, differential diagnosis, and pitfalls of chest wall lesions. They may have an infectious, traumatic, inflammatory etiology or be benign or malignant neoplasms. The US role in the assessment of chest wall abnormalities is limited, usually computed tomography and/or magnetic resonance are requested as second-level imaging exams to characterize and to assess better their relationship with surrounding structures because of larger and panoramic view. Finally, US could be useful to guide biopsy.


Assuntos
Neoplasias da Mama , Parede Torácica , Feminino , Humanos , Parede Torácica/diagnóstico por imagem , Parede Torácica/patologia , Neoplasias da Mama/diagnóstico por imagem , Mastectomia , Ultrassonografia Mamária/métodos , Ultrassonografia
17.
J Pers Med ; 12(12)2022 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-36556182

RESUMO

Sonography companies have recently developed high-frequency transducers (20-30 MHz) to image the skin and small joints. In this pictorial review, we present a number of settings where these probes can be usefully employed to scan the breast. These include skin abnormalities of the breast and axilla; nipple-areolar complex abnormalities; superficial breast parenchyma abnormalities; breast parenchyma abnormalities in subjects with implants; very small female breasts; peripheral areas in breasts of any size; pre-puberal breasts; male breasts; post-mastectomy chest wall; and intraoperative breast sonography. Comparatively, side-by-side images obtained with conventional breast frequencies and high frequencies are shown.

18.
J Clin Med ; 11(22)2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36431102

RESUMO

Embolization in pediatric patients encompasses a large spectrum of indications, ranging from the elective treatment of congenital diseases of the cardiovascular system to the urgent management of acute hemorrhagic conditions. In particular, the endovascular treatment of central and peripheral vascular malformations and hypervascular tumors represents a wide chapter for both congenital and acquired situations. Thanks to the progressive availability of low-profile endovascular devices and new embolic materials, the mini-invasive approach has gradually overtaken surgery. In this review, the main embolization procedures will be illustrated and discussed, with a focus on clinical indications and expected outcomes. The most recent mini-invasive techniques will be described, with hints on the cutting-edge devices and embolic materials.

19.
Tomography ; 8(5): 2369-2402, 2022 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-36287797

RESUMO

Gastrointestinal bleeding is a potentially life-threatening abdominal emergency that remains a common cause of hospitalisation. Although 80-85% of cases of gastrointestinal bleeding resolve spontaneously, it can result in massive haemorrhage and death. The presentation of gastrointestinal bleeding can range from asymptomatic or mildly ill patients requiring only conservative treatments to severely ill patients requiring immediate intervention. Identifying the source of the bleeding can be difficult due to the wide range of potential causes, the length of the gastrointestinal tract and the intermittent nature of the bleeding. The diagnostic and therapeutic approach is fully dependent on the nature of the bleeding and the patient's haemodynamic status. Radiologists should be aware of the appropriate uses of computed tomography angiography and other imaging modalities in patients with acute gastrointestinal bleeding, as well as the semiotics of bleeding and diagnostic pitfalls in order to appropriately diagnose and manage these patients. The learning objective of this review is to illustrate the computed tomography angiography technique, including the potential role of dual-energy computed tomography angiography, also highlighting the tips and tricks to identify the most common and uncommon features of acute gastrointestinal bleeding and its obscure form.


Assuntos
Angiografia , Angiografia por Tomografia Computadorizada , Humanos , Angiografia por Tomografia Computadorizada/efeitos adversos , Angiografia/efeitos adversos , Angiografia/métodos , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/terapia , Tomografia Computadorizada por Raios X/métodos , Doença Aguda
20.
Radiol Med ; 127(11): 1303-1312, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36070065

RESUMO

PURPOSE: This study aims to analyze safety and effectiveness of PHIL® (Microvention, CA-USA) in peripheral endovascular embolization procedures, both in elective and emergent scenarios. MATERIALS AND METHODS: This is a multicenter retrospective study, involving 178 patients from five interventional radiology departments from January 2017 to December 2021. Patients treated by an endovascular embolization with PHIL® were included; different PHIL® viscosities were adopted. Exclusion criteria were: neuroradiological endovascular interventions, other cohesive liquid embolics adopted during the same procedure, follow-up < 30 days. Technical success was intended as definitive target vessel occlusion without the need for other embolics after PHIL® injection. Clinical success was considered as restoration of hemodynamic status in case of emergent embolization and improvement of clinical conditions in case of elective procedures, without additional interventions at 30 days. RESULTS: Sixty-four women and 114 men, mean age 62 years (range 6-91), were evaluated. Sixty-three patients were in elective scenarios (AVMs, type-II endoleaks, tumors, varices, aneurysms, varicoceles) and 115 were in emergent settings (hemorrhage, pseudoaneurysms, hemoptysis, priapism); 190 procedures were performed in 178 patients. Overall technical and clinical success rates were 94.7% and 92.1%, respectively. The complications rate was 7.4% (6 grade-I, 7 grade-III, 1 grade-IV). PHIL®-25 was the more adopted viscosity; totally, 311 vials were injected (rate: 1.64 vial/procedure). CONCLUSION: In this series, PHIL® proved to be a safe and effective liquid embolic in peripheral embolizations, both in elective and emergent scenarios. The pre-filled syringe preparation allowed operators to use it even when unplanned at beginning of the intervention.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Malformações Arteriovenosas Intracranianas , Masculino , Humanos , Feminino , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Malformações Arteriovenosas Intracranianas/tratamento farmacológico , Dimetil Sulfóxido , Polivinil , Estudos Retrospectivos , Resultado do Tratamento , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA