Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Labelled Comp Radiopharm ; 66(12): 400-410, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37679888

RESUMO

[68 Ga]Ga-PentixaFor is a frequently used radiotracer to image the CXCR4/CXCL12 axis in various malignancies, infections, and cardiovascular diseases. To answer increasing clinical needs, an automatized synthesis process ensuring efficient and reproducible production and improving operator's radioprotection is needed. [68 Ga]Ga-PentixaFor synthesis has been described on other synthesizers but not on the miniAiO. In this work, we defined automated synthesis process and an analytical method for the quality control of [68 Ga]Ga-PentixaFor. Validation batches were performed under aseptic conditions in a class A hotcell. All the quality controls required by the European Pharmacopea (Eur. Ph) were performed. The analytical methods were validated according to the International Conference Harmonization (ICH) recommendations. Validation batches were performed with a radiochemical yield of 94.8 ± 2.6%. All the quality controls were in conformity with the Eur. Ph, and the validation of the analytical method complied with the ICH. The environmental monitoring performed during the synthesis process showed that the aseptic conditions were ensured. [68 Ga]Ga-PentixaFor was successfully synthesized with the miniAiO by a fully automated process. This robust production mode and the quality control have been validated in this study allowing to increase the access of patients to this new promising radiopharmaceutical.


Assuntos
Complexos de Coordenação , Humanos , Peptídeos Cíclicos , Compostos Radiofarmacêuticos
2.
J Immunother Cancer ; 9(10)2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34686542

RESUMO

BACKGROUND: Immune checkpoint inhibitor (ICI)-related myocarditis is a rare but potentially fatal adverse event that can occur following ICI exposure. Early diagnosis and treatment are key to improve patient outcomes. Somatostatin receptor-based positron emission tomography-CT (PET/CT) showed promising results for the assessment of myocardial inflammation, yet information regarding its value for the diagnosis of ICI-related myocarditis, especially at the early stage, is limited. Thus, we investigated the value of 68Ga-DOTA(0)-Phe(1)-Tyr(3)-octreotide (68Ga-DOTATOC) PET/CT for the early detection and diagnosis of ICI-related myocarditis. METHODS: Consecutive patients with clinically suspected ICI-related myocarditis from July 2018 to February 2021 were retrospectively evaluated in this single-center study. All patients underwent imaging for the detection of ICI-related myocarditis using either cardiac magnetic resonance (CMR) imaging or 68Ga-DOTATOC PET/CT. PET/CT images were acquired 90 min after the injection of 2 MBq/kg 68Ga-DOTATOC with pathological myocardial uptake in the left ventricle (LV) suggestive of myocarditis defined using a myocardium-to-background ratio of peak standard uptake value to mean intracavitary LV standard uptake (MBRpeak) value above 1.6. Patients had a full cardiological work-up including ECG, echocardiography, serum cardiac troponin I (cTnI), cardiac troponin T and creatine kinase (CK), CK-MB. Endomyocardial biopsy and inflammatory cytokine markers were also analyzed. The detection rate of ICI-related myocarditis using 68Ga-DOTATOC PET/CT and CMR was assessed. RESULTS: A total of 11 patients had clinically suspected ICI-related myocarditis; 9 underwent 68Ga -DOTATOC PET/CT. All nine (100%) patients with 68Ga-DOTATOC PET/CT presented with pathological myocardial uptake in the LV that was suggestive of myocarditis (MBRpeak of 3.2±0.8, range 2.2-4.4). Eight patients had CMR imaging and 3/8 (38%) patients had lesions evocative of myocarditis. All PET-positive patients were previously treated with a high dose of steroids and intravenous immunoglobulin prior to PET/CT had elevated serum cTnI except for one patient for whom PET/CT was delayed several days. Interestingly, in 5/6 (83%) patients who presented with concomitant myositis, pathological uptake was seen on whole-body 68Ga-DOTATOC PET/CT images in the skeletal muscles, suggesting an additional advantage of this method to assess the full extent of the disease. In contrast, four patients with CMR imaging had negative findings despite having elevated serum cTnI levels (range 20.5-5896.1 ng/mL), thus defining possible myocarditis. Newly identified immune correlates could provide specific biomarkers for the diagnosis of ICI-related myocarditis. Most tested patients (six of seven patients) had serum increases in the inflammatory cytokine interleukin (IL)-6 and in the chemokines CXCL9, CXCL10, and CXCL13, and the mass cytometry phenotypes of immune cell populations in the blood also showed correlations with myocardial inflammation. Four of five patients with myocarditis exhibited a Th1/Th2 imbalance favoring a pronounced inflammatory Th1, Th1/Th17, and Th17 CD4 memory T-cell response. The high proportion of non-classical monocytes and significantly reduced levels of CD31 in four to five patients was also consistent with an inflammatory disease. CONCLUSION: The use of 68Ga-DOTATOC PET/CT along with immune correlates is a highly sensitive method to detect ICI-related myocarditis especially in the early stage of myocardial inflammation, as patients with elevated cTnI may present normal CMR imaging results. 68Ga-DOTATOC PET/CT is also useful for detecting concomitant myositis. These results need to be confirmed in a larger population of patients and validated against a histological gold standard if available.


Assuntos
Radioisótopos de Gálio/uso terapêutico , Inibidores de Checkpoint Imunológico/efeitos adversos , Miocardite/induzido quimicamente , Miocardite/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Idoso , Feminino , Humanos , Masculino
3.
J Labelled Comp Radiopharm ; 58(7): 274-80, 2015 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-26017396

RESUMO

Lymphomas are the most frequent haematological malignancy. In non-Hodgkin's lymphomas (NHL), more than 90% of tumor cells express the cluster of differentiation (CD) 20 antigen. At the end of frontline therapy, the evaluation of remission is based on computed tomography (CT) and positron emission tomography coupled with computer tomography (PET/CT) with [(18)F]-fluorodeoxyglucose ([(18)F]FDG). Unfortunately, these techniques are not specific and cannot distinguish residual active tumor from inflammation. The aim of this study was to develop a specific radiotracer of NHL CD 20+ cells for clinical applications. The radiolabelling technique presented, based on the use of tricarbonyl compound, does not include an antibody reduction because this step could damage the protein. Actually, rituximab, an anti-CD 20 chimeric antibody used for the treatment of these NHL, was radiolabelled with Isolink® (99m)Tc-tricarbonyl compound in a three-step procedure without using a specific antibody reducer. Radiolabelling yield was greater than 97%. In vitro experiments showed a conservation of antibody integrity. In vivo experiments using Single-photon emission computed tomography/CT showed significant tumor targeting 24 h after injection of the radiotracer. It was consequently possible to develop an immunoradiolabelling method to specifically detect the residual disease. As this procedure is fast, reproducible and gentle, it will be possible to comply with Good Manufacturing Practices.


Assuntos
Compostos Radiofarmacêuticos/síntese química , Rituximab/química , Tecnécio/química , Animais , Linhagem Celular Tumoral , Humanos , Camundongos , Compostos Radiofarmacêuticos/farmacocinética , Distribuição Tecidual , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA