Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
J Orthop Res ; 2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38735861

RESUMO

Knee arthroplasty technique is constantly evolving and the opportunity for surgeons to practice new techniques is currently highly dependent on the availability of cadaveric specimens requiring certified facilities. The high cost, limited supply, and heterogeneity of cadaveric specimens has increased the demand for synthetic training models, which are currently limited by a lack of biomechanical fidelity. Here, we aimed to design, manufacture, and experimentally validate a synthetic knee surgical training model which reproduces the flexion dependent varus-valgus (VV) and anterior-posterior (AP) mechanics of cadaveric knees, while maintaining anatomic accuracy. A probabilistic finite element modeling approach was employed to design physical models to exhibit passive cadaveric VV and AP mechanics. Seven synthetic models were manufactured and tested in a six-degree-of-freedom hexapod robot. Overall, the synthetic models exhibited cadaver-like VV and AP mechanics across a wide range of flexion angles with little variation between models. In the extended position, two models showed increased valgus rotation (<0.5°), and three models showed increased posterior tibial translation (<1.7 mm) when compared to the 95% confidence interval (CI) of cadaveric measurements. At full flexion, all models showed VV and AP mechanics within the 95% CI of cadaveric measurements. Given the repeatable mechanics exhibited, the knee models developed in this study can be used to reduce the current reliance on cadaveric specimens in surgical training.

2.
J Mech Behav Biomed Mater ; 124: 104817, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34536802

RESUMO

In vitro real-time replication of three-dimensional, time-varying load profiles acting on human bones during physical activity can advance bone and implant testing protocols. This study aimed to develop a novel protocol for applying the three-dimensional, time-varying hip contact force while walking to a human femur specimen. The target force profile was obtained from the literature. A proximal femur from an elderly female donor was instrumented using ten rosette strain gages and tested using a custom-made hexapod robot. A load-control algorithm determined the robot position generating the target force at low frequency (0.0004 Hz). Five cycles of the robot position were played back at five intermediate frequencies up to real-time (0.04, 0.08, 0.16, 0.4, and 0.8 Hz). The hip reaction force, the length of the actuators (position), and cortical strains were compared. The error in the load-control force was 0.3 ± 4.2 N (mean ± SD). The last three force, position, and strain cycles varied by less than 1.1% for every frequency analyzed. Across frequencies, the force increased by 28% at 0.8 Hz as a logarithmic function of frequency (R2 = 0.98). The position and strain error linearly increased with frequency up to 0.4 Hz. The median position error and the interquartile range of the strain error reached 15% and 13% at 0.8 Hz. Changes of force and cortical strain at increasing frequencies were linearly related (R2 = 0.99). Therefore, the protocol developed can provide repeatable three-dimensional time-varying load profiles, although the comparison of the specimen deformation obtained across frequencies should be considered with care, particularly in the higher frequency range. This information supports the design of dynamic tests of bone and implants.


Assuntos
Fêmur , Caminhada , Idoso , Fenômenos Biomecânicos , Osso e Ossos , Feminino , Humanos , Estresse Mecânico
3.
JOR Spine ; 4(1): e1138, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33778410

RESUMO

Biomechanical testing methodologies for the spine have developed over the past 50 years. During that time, there have been several paradigm shifts with respect to techniques. These techniques evolved by incorporating state-of-the-art engineering principles, in vivo measurements, anatomical structure-function relationships, and the scientific method. Multiple parametric studies have focused on the effects that the experimental technique has on outcomes. As a result, testing methodologies have evolved, but there are no standard testing protocols, which makes the comparison of findings between experiments difficult and conclusions about in vivo performance challenging. In 2019, the international spine research community was surveyed to determine the consensus on spine biomechanical testing and if the consensus opinion was consistent with the scientific evidence. More than 80 responses to the survey were received. The findings of this survey confirmed that while some methods have been commonly adopted, not all are consistent with the scientific evidence. This review summarizes the scientific literature, the current consensus, and the authors' recommendations on best practices based on the compendium of available evidence.

4.
J Biomech Eng ; 143(6)2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33590841

RESUMO

Bilateral cervical facet dislocation (BFD) with facet fracture (Fx) often causes tetraplegia but is rarely recreated experimentally, possibly due to a lack of muscle replication. Intervertebral axial compression (due to muscle activation) or distraction (due to inertial loading), when combined with excessive anterior translation, may influence interfacet contact or separation and the subsequent production of BFD with or without Fx. This paper presents a methodology to produce C6/C7 BFD+Fx using anterior shear motion superimposed with 300 N compression or 2.5 mm distraction. The effect of these superimposed axial conditions on six-axis loads, and C6 inferior facet deflections and surface strains, was assessed. Twelve motion segments (70 ± 13 yr) achieved 2.19 mm of supraphysiologic anterior shear without embedding failure (supraphysiologic shear analysis point; SSP), and BFD+Fx was produced in all five specimens that reached 20 mm of shear. Linear mixed-effects models (α = 0.05) assessed the effect of axial condition. At the SSP, the compressed specimens experienced higher axial forces, facet shear strains, and sagittal facet deflections, compared to the distracted group. Facet fractures had similar radiographic appearance to those that are observed clinically, suggesting that intervertebral anterior shear motion contributes to BFD+Fx.


Assuntos
Articulação Zigapofisária
5.
Acta Biomater ; 123: 208-221, 2021 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-33453409

RESUMO

Collagen fibers within the annulus fibrosus (AF) lamellae are unidirectionally aligned with alternating orientations between adjacent layers. AF constitutive models often combine two adjacent lamellae into a single equivalent layer containing two fiber networks with a crisscross pattern. Additionally, AF models overlook the inter-lamellar matrix (ILM) as well as elastic fiber networks in between lamellae. We developed a nonhomogenous micromechanical model as well as two coarser homogenous hyperelastic and microplane models of the human AF, and compared their performances against measurements (tissue level uniaxial and biaxial tests as well as whole disc experiments) and seven published hyperelastic models. The micromechanical model had a realistic non-homogenous distribution of collagen fiber networks within each lamella and elastic fiber network in the ILM. For small matrix linear moduli (<0.2 MPa), the ILM showed substantial anisotropy (>10%) due to the elastic fiber network. However, at moduli >0.2 MPa, the effects of the elastic fiber network on differences in stress-strain responses at different directions disappeared (<10%). Variations in sample geometry and boundary conditions (due to uncertainty) markedly affected stress-strain responses of the tissue in uniaxial and biaxial tests (up to 16 times). In tissue level tests, therefore, simulations should represent testing conditions (e.g., boundary conditions, specimen geometry, preloads) as closely as possible. Stress/strain fields estimated from the single equivalent layer approach (conventional method) yielded different results from those predicted by the anatomically more accurate apparoach (i.e., layerwise). In addition, in a disc under a compressive force (symmetric loading), asymmetric stress-strain distributions were computed when using a layerwise simulation. Although all developed and selected published AF models predicted gross compression-displacement responses of the whole disc within the range of measured data, some showed excessively stiff or compliant responses under tissue-level uniaxial/biaxial tests. This study emphasizes, when constructing and validating constitutive models of AF, the importance of the proper simulation of individual lamellae as distinct layers, and testing parameters (sample geometric dimensions/loading/boundary conditions).


Assuntos
Anel Fibroso , Disco Intervertebral , Anisotropia , Fenômenos Biomecânicos , Humanos , Modelos Biológicos , Pressão , Estresse Mecânico
6.
Spine (Phila Pa 1976) ; 45(6): 357-367, 2020 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-31593056

RESUMO

STUDY DESIGN: A biomechanical analysis correlating internal disc strains and tissue damage during simulated repetitive lifting. OBJECTIVE: To understand the failure modes during simulated safe and unsafe repetitive lifting. SUMMARY OF BACKGROUND DATA: Repetitive lifting has been shown to lead to lumbar disc herniation (LDH). In vitro studies have developed a qualitative understanding of the effect of repetitive loading on LDH. However, no studies have measured internal disc strains and subsequently correlated these with disc damage. METHODS: Thirty human cadaver lumbar functional spinal units were subjected to an equivalent of 1 year of simulated repetitive lifting under safe and unsafe levels of compression, in combination with flexion (13-15°), and right axial rotation (2°) for 20,000 cycles or until failure. Safe or unsafe lifting were applied as a compressive load to mimic holding a 20 kg weight either close to, or at arm's length, from the body, respectively. Maximum shear strains (MSS) were measured, and disc damage scores were determined in nine regions from axial post-test magnetic resonance imaging (MRI) and macroscopic images. RESULTS: Twenty percent of specimens in the safe lifting group failed before 20,000 cycles due to endplate failure, compared with 67% in the unsafe group. Over half of the specimens in the safe lifting group failed via either disc protrusion or LDH, compared with only 20% via protrusion in the unsafe group. Significant positive correlations were found between MRI and macroscopic damage scores in all regions (rs > 0.385, P < 0.049). A significant positive correlation was observed in the left lateral region for MSS versus macroscopic damage score (rs = 0.486, P < 0.037) and MSS versus failure mode (rs = 0.724, P = 0.018, only specimens with disc failure). Pfirrmann Grade 3 discs were strongly associated with subsequent LDH (P = 0.003). CONCLUSION: Increased shear strains were observed in the contralateral side to the applied rotation as disc injury progressed from protrusion to LDH. Larger compressive loads applied to simulate unsafe lifting led to frequent early failure of the endplate, however, smaller compressive loads at similar flexion angles applied under safe lifting led to more loading cycles before failure, where the site of failure was more likely to be the disc. Our study demonstrated that unsafe lifting leads to greater risk of injury compared with safe lifting, and LDH and disc protrusion were more common in the posterior/posterolateral regions. LEVEL OF EVIDENCE: N/A.


Assuntos
Fenômenos Biomecânicos/fisiologia , Degeneração do Disco Intervertebral/diagnóstico por imagem , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Disco Intervertebral/diagnóstico por imagem , Remoção/efeitos adversos , Adulto , Idoso , Cadáver , Feminino , Humanos , Disco Intervertebral/patologia , Degeneração do Disco Intervertebral/etiologia , Deslocamento do Disco Intervertebral/etiologia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Pressão/efeitos adversos , Amplitude de Movimento Articular/fisiologia , Rotação/efeitos adversos , Suporte de Carga/fisiologia
7.
PLoS One ; 14(11): e0224432, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31738770

RESUMO

Increases in the number of shark bites, along with increased media attention on shark-human interactions has led to growing interest in preventing injuries from shark bites through the use of personal mitigation measures. The leading cause of fatality from shark bite victims is blood loss; thus reducing haemorrhaging may provide additional time for a shark bite victim to be attended to by emergency services. Despite previous shark-proof suits being bulky and cumbersome, new technological advances in fabric has allowed the development of lightweight alternatives that can be incorporated onto traditional wetsuits. The ability for these fabrics to withstand shark bites has not been scientifically tested. In this report, we compared two types of recently developed protective fabrics that incorporated ultra-high molecular weight polyethylene (UHMWPE) fibre onto neoprene (SharkStop and ActionTX) and compared them to standard neoprene alternatives. We tested nine different fabric variants using three different tests, laboratory-based puncture and laceration tests, along with field-based trials involving white sharks Carcharodon carcharias. Field-based trials consisted of measuring C. carcharias bite force and quantifying damages to the new fabrics following a bite from 3-4 m total length C. carcharias. We found that SharkStop and ActionTX fabric variants were more resistant to puncture, laceration, and bites from C. carcharias. More force was required to puncture the new fabrics compared to control fabrics (laboratory-based tests), and cuts made to the new fabrics were smaller and shallower than those on standard neoprene for both types of test, i.e. laboratory and field tests. Our results showed that UHMWPE fibre increased the resistance of neoprene to shark bites. Although the use of UHMWPE fibre (e.g. SharkStop and ActionTX) may therefore reduce blood loss resulting from a shark bite, research is needed to assess if the reduction in damages to the fabrics extends to human tissues and decreased injuries.


Assuntos
Mordeduras e Picadas/prevenção & controle , Lacerações/prevenção & controle , Roupa de Proteção , Tubarões , Têxteis , Animais , Mordeduras e Picadas/etiologia , Humanos , Lacerações/etiologia , Teste de Materiais , Polietilenos , Dente
8.
JOR Spine ; 2(1): e1047, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31463461

RESUMO

The kinematics of the intervertebral disc are defined by six degrees of freedom (DOF): three translations (Tz: axial compression, Tx: lateral shear, and Ty: anterior-posterior shear) and three rotations (Rz: torsion, Rx: flexion-extension, and Ry: lateral bending). There is some evidence that the six DOFs are mechanically coupled, such that loading in one DOF affects the mechanics of the other five "off-axis" DOFs, however, most studies have not controlled and/or measured all six DOFs simultaneously. Additionally, the relationships between disc geometry and disc mechanics are important for evaluation of data from different sized donor and patient discs. The objectives of this study were to quantify the mechanical behavior of the intervertebral disc in all six degrees of freedom (DOFs), measure the coupling between the applied motion in each DOF with the resulting off-axis motions, and test the hypothesis that disc geometry influences these mechanical behaviors. All off-axis displacements and rotations were significantly correlated with the applied DOF and were of similar magnitude as physiologically relevant motion, confirming that off-axis coupling is an important mechanical response. Interestingly, there were pairs of DOFs that were especially strongly coupled: lateral shear (Tx) and lateral bending (Ry), anterior-posterior shear (Ty) and flexion-extension (Rx), and compression (Tz) and torsion (Rz). Large off-axis shears may contribute to injury risk in bending and flexion. In addition, the disc responded to shear (Tx, Ty) and rotational loading (Rx, Ry, and Rz) by increasing in disc height in order to maintain the applied compressive load. Quantifying these mechanical behaviors across all six DOF are critical for designing and testing disc therapies, such as implants and tissue engineered constructs, and also for validating finite element models.

9.
J Biomech ; 83: 205-213, 2019 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-30554817

RESUMO

The subaxial cervical facets are important load-bearing structures, yet little is known about their mechanical response during physiological or traumatic intervertebral motion. Facet loading likely increases when intervertebral motions are superimposed with axial compression forces, increasing the risk of facet fracture. The aim of this study was to measure the mechanical response of the facets when intervertebral axial compression or distraction is superimposed on constrained, non-destructive shear, bending and rotation motions. Twelve C6/C7 motion segments (70 ±â€¯13 yr, nine male) were subjected to constrained quasi-static anterior shear (1 mm), axial rotation (4°), flexion (10°), and lateral bending (5°) motions. Each motion was superimposed with three axial conditions: (1) 50 N compression; (2) 300 N compression (simulating neck muscle contraction); and, (3) 2.5 mm distraction. Angular deflections, and principal and shear surface strains, of the bilateral C6 inferior facets were calculated from motion-capture data and rosette strain gauges, respectively. Linear mixed-effects models (α = 0.05) assessed the effect of axial condition. Minimum principal and maximum shear strains were largest in the compressed condition for all motions except for maximum principal strains during axial rotation. For right axial rotation, maximum principal strains were larger for the contralateral facets, and minimum principal strains were larger for the left facets, regardless of axial condition. Sagittal deflections were largest in the compressed conditions during anterior shear and lateral bending motions, when adjusted for facet side.


Assuntos
Vértebras Cervicais/fisiologia , Movimento , Rotação , Idoso , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pressão , Suporte de Carga
10.
Mater Sci Eng C Mater Biol Appl ; 93: 299-304, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30274062

RESUMO

A simple and cost effective protocol for visualization and isolation of the elastic fibres network in the annulus fibrosus (AF) of the disc is explained, to provide other researchers a method that can be applied in disc ultra-structural analysis, biomechanical assessment of elastic fibre and tissue engineered scaffold fabrication. This protocol is developed based on simultaneous sonication and alkali digestion of tissue that eliminates all matrix constituents except for elastic fibres, which is applicable for different species including human. Thin samples harvested from ovine, bovine, porcine and human, which are commonly used in disc research, were exposed to 0.5 M sodium hydroxide solution along with sonication (25 kHz) in distilled water for defined periods of time at room temperature. Post heat treatment removed collagen fibres via the gelatinization process, for visualization of elastic fibres.


Assuntos
Anel Fibroso/química , Tecido Elástico/química , Alicerces Teciduais/química , Animais , Bovinos , Humanos , Ovinos
11.
Acta Biomater ; 77: 292-300, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30017922

RESUMO

The mechanical role of elastic fibers in the inter-lamellar matrix (ILM) is unknown; however, it has been suggested that they play a role in providing structural integrity to the annulus fibrosus (AF). Therefore, the aim of this study was to measure the viscoelastic and failure properties of the elastic fiber network in the ILM of ovine discs under both tension and shear directions of loading. Utilizing a technique, isolated elastic fibers within the ILM from ovine discs were stretched to 40% of their initial length at three strain rates of 0.1% s-1 (slow), 1% s-1 (medium) and 10% s-1 (fast), followed by a ramp test to failure at 10% s-1. A significant strain-rate dependent response was found, particularly at the fastest rate for phase angle and normalized stiffness (p < 0.001). The elastic fibers in the ILM demonstrated a significantly higher capability for energy absorption at slow compared to medium and fast strain rates (p < 0.001). These finding suggests that the elastic fiber network of the ILM exhibits nonlinear elastic behavior. When tested to failure, a significantly higher normalized failure force was found in tension compared to shear loading (p = 0.011), which is consistent with the orthotropic structure of elastic fibers in the ILM. The results of this study confirmed the mechanical contribution of the elastic fiber network to the ILM and the structural integrity of the AF. This research serves as a foundation for future studies to investigate the relationship between degeneration and ILM mechanical properties. STATEMENT OF SIGNIFICANCE: The mechanical role of elastic fibres in the inter-lamellar matrix (ILM) of the disc is unknown. The viscoelastic and failure properties of the elastic fibre network in the ILM in both tension and shear directions of loading was measured for the first time. We found a strain-rate dependent response for the elastic fibres in the ILM. The elastic fibres in the ILM demonstrated a significantly higher capability for energy absorption at slow compared to medium and fast strain rates. When tested to failure, a significantly higher normalized failure force was found in tension compared to shear loading, which is consistent with the orthotropic structure of elastic fibres in the ILM.


Assuntos
Anel Fibroso/fisiologia , Tecido Elástico/fisiologia , Animais , Fenômenos Biomecânicos , Elasticidade , Resistência ao Cisalhamento , Ovinos , Estresse Mecânico , Resistência à Tração , Viscosidade
12.
Ann Biomed Eng ; 46(9): 1280-1291, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29786777

RESUMO

While microstructural observations have improved our understanding of possible pathways of herniation progression, no studies have measured the mechanical failure properties of the inter-lamellar matrix (ILM), nor of the adjacent lamellae during progression to herniation. The aim of this study was to employ multiscale, biomechanical and microstructural techniques to evaluate the effects of progressive induced herniation on the ILM and lamellae in control, pre-herniated and herniated discs (N = 7), using 2 year-old ovine spines. Pre-herniated and herniated (experimental) groups were subjected to macroscopic compression while held in flexion (13°), before micro-mechanical testing. Micro-tensile testing of the ILM and the lamella from anterior and posterolateral regions was performed in radial and circumferential directions to measure failure stress, modulus, and toughness in all three groups. The failure stress of the ILM was significantly lower for both experimental groups compared to control in each of radial and circumferential loading directions in the posterolateral region (p < 0.032). Within each experimental group in both loading directions, the ILM failure stress was significantly lower by 36% (pre-herniation), and 59% (herniation), compared to the lamella (p < 0.029). In pre-herniated compared to control discs, microstructural imaging revealed significant tissue stretching and change in orientation (p < 0.003), resulting in a loss of distinction between respective lamellae and ILM boundaries.


Assuntos
Deslocamento do Disco Intervertebral/fisiopatologia , Vértebras Lombares/fisiologia , Animais , Fenômenos Biomecânicos , Ovinos , Estresse Mecânico
13.
J Biomech ; 72: 116-124, 2018 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-29627133

RESUMO

Traumatic cervical facet dislocation (CFD) is often associated with devastating spinal cord injury. Facet fractures commonly occur during CFD, yet quantitative measures of facet deflection, strain, stiffness and failure load have not been reported. The aim of this study was to determine the mechanical response of the subaxial cervical facets when loaded in directions thought to be associated with traumatic bilateral CFD - anterior shear and flexion. Thirty-one functional spinal units (6 × C2/3, C3/4, C4/5, and C6/7, 7 × C5/6) were dissected from fourteen human cadaver cervical spines (mean donor age 69 years, range 48-92; eight male). Loading was applied to the inferior facets of the inferior vertebra to simulate the in vivo inter-facet loading experienced during supraphysiologic anterior shear and flexion motion. Specimens were subjected to three cycles of sub-failure loading (10-100 N, 1 mm/s) in each direction, before being failed in a randomly assigned direction (10 mm/s). Facet deflection, surface strains, stiffness, and failure load were measured. Linear mixed-effects models (α = 0.05; random effect of cadaver) accounted for variations in specimen geometry and bone density. Specimen-specific parameters were significantly associated with most outcome measures. Facet stiffness and failure load were significantly greater in the simulated flexion loading direction, and deflection and surface strains were higher in anterior shear at the non-destructive analysis point (47 N applied load). The sub-failure strains and stiffness responses differed between the upper and lower subaxial cervical regions. Failure occurred through the facet tip during anterior shear loading, while failure through the pedicles was most common in flexion.


Assuntos
Vértebras Cervicais/fisiologia , Traumatismos da Medula Espinal/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Densidade Óssea , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Estresse Mecânico
14.
J Biomech ; 70: 59-66, 2018 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-28951045

RESUMO

The complexity of multi-axis spine testing often makes it challenging to compare results from different studies. The aim of this work was to develop and implement a standardized testing protocol across three six-axis spine systems, compare them, and provide stiffness and phase angle limits against which other test systems can be compared. Standardized synthetic lumbar specimens (n=5), comprising three springs embedded in polymer at each end, were tested on each system using pure moments in flexion-extension, lateral bending, and axial rotation. Tests were performed using sine and triangle waves with an amplitude of 8Nm, a frequency of 0.1Hz, and with axial preloads of 0 and 500N. The stiffness, phase angle, and R2 value of the moment against rotation in the principal axis were calculated at the center of each specimen. The tracking error was adopted asa measure of each test system to minimize non-principal loads, defined as the root mean squared difference between actual and target loads. All three test systems demonstrated similar stiffnesses, with small (<14%) but significant differences in 4 of 12 tests. More variability was observed in the phase angle between the principal axis moment and rotation, with significant differences in 10 of 12 tests. Stiffness and phase angle limits were calculated based on the 95% confidence intervals from all three systems. These recommendations can be used with the standard specimen and testing protocol by other research institutions to ensure equivalence of different spine systems, increasing the ability to compare in vitro spine studies.


Assuntos
Vértebras Lombares/fisiologia , Fenômenos Biomecânicos , Teste de Materiais/métodos , Rotação
15.
J Biomech ; 67: 24-31, 2018 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-29221904

RESUMO

Disc degeneration is a common medical affliction whose origins are not fully understood. An improved understanding of its underlying mechanisms could lead to the development of more effective treatments. The aim of this paper was to investigate the effect of (1) degeneration, (2) circumferential region and (3) strain rate on the microscale mechanical properties (toe region modulus, linear modulus, extensibility, phase angle) of individual fibre bundles in the anulus fibrosus lamellae of the human intervertebral disc. Healthy and degenerate fibre bundles excised from different circumferential regions in the outer anulus (posterolateral, lateral, anterolateral, anterior) were tensile tested at slow (0.1%/s), medium (1%/s) and fast (10%/s) strain rates using a micromechanical testing system. Our preliminary results showed that neither degeneration nor circumferential region significantly affected the fibre bundles' mechanical behaviour. However, when the fibre bundles were tested at higher strain rates, this resulted in significantly higher linear moduli and lower phase angles. These findings, compared with data from other studies investigating single and multiple lamellae sections, suggest that degeneration has minimal effect on outer anulus mechanics irrespective of structural level, and the inter- and intra-lamellar arrangement and continuity of the fibre bundles may influence the lamellae's regional behaviour and viscoelasticity.


Assuntos
Anel Fibroso/fisiologia , Disco Intervertebral/fisiologia , Vértebras Lombares/fisiologia , Região Lombossacral/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Humanos , Pessoa de Meia-Idade , Estresse Mecânico , Resistência à Tração , Viscosidade , Adulto Jovem
16.
Spine J ; 18(3): 387-398, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28739474

RESUMO

BACKGROUND CONTEXT: Distractive flexion injuries (DFIs) of the subaxial cervical spine are major contributors to spinal cord injury (SCI). Prompt assessment and early intervention of DFIs associated with SCI are crucial to optimize patient outcome; however, neurologic examination of patients with subaxial cervical injury is often difficult, as patients commonly present with reduced levels of consciousness. Therefore, it is important to establish potential associations between injury epidemiology and radiographic features, and neurologic involvement. PURPOSE: The aims of this study were to describe the epidemiology and radiographic features of DFIs presenting to a major Australian tertiary hospital and to identify those factors predictive of SCI. The agreement and repeatability of radiographic measures of DFI severity were also investigated. STUDY DESIGN/SETTING: This is a combined retrospective case-control and reliability-agreement study. PATIENT SAMPLE: Two hundred twenty-six patients (median age 40 years [interquartile range = 34]; 72.1% male) who presented with a DFI of the subaxial cervical spine between 2003 and 2013 were reviewed. OUTCOME MEASURES: The epidemiology and radiographic features of DFI, and risk factors for SCI were identified. Inter- and intraobserver agreement of radiographic measurements was evaluated. METHODS: Medical records, radiographs, and computed tomography and magnetic resonance imaging scans were examined, and the presence of SCI was evaluated. Radiographic images were analyzed by two consultant spinal surgeons, and the degree of vertebral translation, facet apposition, spinal canal occlusion, and spinal cord compression were documented. Multivariable logistic regression models identified epidemiology and radiographic features predictive of SCI. Intraclass correlation coefficients (ICCs) examined inter- and intraobserver agreement of radiographic measurements. RESULTS: The majority of patients (56.2%) sustained a unilateral (51.2%) or a bilateral facet (48.8%) dislocation. The C6-C7 vertebral level was most commonly involved (38.5%). Younger adults were over-represented among motor-vehicle accidents, whereas falls contributed to a majority of DFIs sustained by older adults. Greater vertebral translation, together with lower facet apposition, distinguished facet dislocation from subluxation. Dislocation, bilateral facet injury, reduced Glasgow Coma Scale, spinal canal occlusion, and spinal cord compression were predictive of neurologic deficit. Radiographic measurements demonstrated at least a "moderate" agreement (ICC>0.4), with most demonstrating an "almost perfect" reproducibility. CONCLUSIONS: This large-scale cohort investigation of DFIs in the cervical spine describes radiographic features that distinguish facet dislocation from subluxation, and associates highly reproducible anatomical and clinical indices to the occurrence of concomitant SCI.


Assuntos
Vértebras Cervicais/lesões , Luxações Articulares/epidemiologia , Traumatismos da Medula Espinal/epidemiologia , Fraturas da Coluna Vertebral/epidemiologia , Adulto , Idoso , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/patologia , Feminino , Humanos , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Radiografia , Traumatismos da Medula Espinal/diagnóstico por imagem , Traumatismos da Medula Espinal/patologia , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/patologia , Tomografia Computadorizada por Raios X
17.
J Mech Behav Biomed Mater ; 71: 175-183, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28342325

RESUMO

Collagen and elastic fibers are two major fibrous constituents of the annulus fibrosus (AF) in the disc that contribute to its mechanical and viscoelastic properties. It was thought that elastic fibers play no substantial role in the function and properties of the disc as these fibers were irregularly distributed. Studies that have revealed highly organized elastic fibers with different regional orientation and distribution, while being strongly crosslinked with matrix, suggesting their contribution to disc structure-function properties. These studies that were performed by light microscopic analysis of histologically prepared samples, have not been able to reveal the fine-scale architectural details of the elastic fiber network. Since elastic fibers are intermingled with other fibrous components of the disc and mostly obscured by the extracellular matrix, it is difficult to demonstrate their ultra-structural organization using scanning electron microscopy (SEM). Therefore the aim of this study was to develop a rapid matrix digestion technique for ultrastructural analysis of the disc elastic fibers. This study provides a new method for fundamental visualization of elastic fibers and their architecture in the disc. Through the ultra-structural analysis, the relationship between structure and function, as well as the role of elastic fibers on AF mechanical properties can be studied. This method may be used to develop a three-dimensional map of elastic fibers distribution within the disc, which would provide valuable information for designing tissue engineered scaffolds for AF repair and replacement.


Assuntos
Tecido Elástico/ultraestrutura , Matriz Extracelular/química , Disco Intervertebral/ultraestrutura , Anel Fibroso , Colágeno , Humanos , Microscopia Eletrônica de Varredura
18.
J Orthop Res ; 34(8): 1399-409, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27291789

RESUMO

While the effects of disc degeneration on compression and rotation motions have been studied, there is no data for shear loading. Clinical research has shown that those with low back pain (a potential consequence of degeneration) experience a 75% greater lateral shear force than those without it. Therefore, the aim was to compare the effect of degeneration on spine segment stiffness and phase angle in each of six degree of freedom (6DOF) loading directions. Fourteen intact functional spinal units (FSU) were dissected from human lumbar spines (mean (SD) age 76.2 (11) years, Thompson grades 3 (N = 5, mild), 4 (N = 6, moderate), 5 (N = 3, severe)). Each FSU was tested in ±6DOFs while subjected to a physiological preload, hydration, and temperature (37°C) conditions in a hexapod robot. A one-way ANOVA between degenerated groups was performed on stiffness and phase angle for each DOF. Significant differences in stiffness were found between mild and moderate degenerative groups in lateral shear (p = 0.001), and axial rotation (p = 0.001), where moderate degeneration had decreased stiffness. For phase angle, significant differences were seen in anterior shear (p = 0.017), and axial rotation (p = 0.026), where phase angle for mild degeneration was less than moderate. Trends of stiffness and phase angle changes between degenerative groups were similar within each DOF. Clinically, the identification of the DOFs that are most affected by degeneration could be used in rehabilitation to improve supplemental stabilization of core muscle groups. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1399-1409, 2016.


Assuntos
Degeneração do Disco Intervertebral/fisiopatologia , Vértebras Lombares/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade
19.
J Orthop Res ; 34(8): 1307-15, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27208689

RESUMO

The inter-lamellar matrix (ILM) has an average thickness of less than 30 µm and lies between adjacent lamellae in the annulus fibrosus (AF). The microstructure and composition of the ILM have been studied in various anatomic regions of the disc; however, their contribution to AF mechanical properties and structural integrity is unknown. It was suggested that the ILM components, mainly elastic fibers and cross-bridges, play a role in providing mechanical integrity of the AF. Therefore, the manner in which they respond to different loadings and stabilize adjacent lamellae structure will influence AF tear formation and subsequent herniation. This review paper summarizes the composition, microstructure, and potential role of the ILM in the progression of disc herniation, clarifies the micromechanical properties of the ILM, and proposes critical areas for future studies. There are a number of unknown characteristics of the ILM, such as its mechanical role, impact on AF integrity, and ultrastructure of elastic fibers at the ILM-lamella boundary. Determining these characteristics will provide important information for tissue engineering, repair strategies, and the development of more-physiological computational models to study the initiation and propagation of AF tears that lead to herniation and degeneration. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1307-1315, 2016.


Assuntos
Anel Fibroso/anatomia & histologia , Anel Fibroso/fisiologia , Fenômenos Biomecânicos , Humanos , Degeneração do Disco Intervertebral/etiologia
20.
J Orthop Trauma ; 29(11): e437-41, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26165261

RESUMO

OBJECTIVE: The level to which bone screws are tightened is determined subjectively by the operating surgeon. It is likely that the tactile feedback that surgeons rely on is based on localized tissue yielding, which may predispose the screw-bone interface to failure. A limited number of studies have investigated the ratio between clinical tightening torque and stripping torque. The purpose of this study was to measure, for the first time, the ratio between yield torque (T yield) and stripping torque (T max) during screw insertion into the cancellous bone and to compare these torques with clinical levels of tightening reported in the literature. Additionally, a rotational limit was investigated as a potential end point for screw insertion in cancellous bone. METHODS: A 6.5-mm outer diameter commercial cancellous bone screw was inserted into human femoral head specimens (n = 89). Screws were inserted to failure, while recording insertion torque, compression under the screw head, and rotation angle. RESULTS: The median, interquartile ranges, and coefficient of variation were calculated for each of the following parameters: T yield, T max, T yield/T max, slope, T plateau, and rotation angle. The median ratio of T yield/T max and rotation angle was 85.45% and 96.5 degrees, respectively. The coefficient of variation was greatest for the rotation angle compared with the ratio of T yield/T max (0.37 vs. 0.12). CONCLUSIONS: The detection of yield may be a more precise method than the rotation angle in cancellous bone; however, bone-screw constructs that exhibit a T yield close to T max may be more susceptible to stripping during insertion. Future work can identify factors that influence the ratio of T yield/T max may help to reduce the incidence of screw stripping.


Assuntos
Parafusos Ósseos , Cabeça do Fêmur/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Cabeça do Fêmur/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA