Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Vet Med Sci ; 10(2): e1403, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38419297

RESUMO

BACKGROUND: Albuminuria, an important marker of decreased kidney function in chronic kidney disease (CKD), is not routinely used for CKD detection or proteinuria appearance. Its relationships with biochemical parameters and blood pressure in dogs are poorly understood. OBJECTIVES: This study aimed to evaluate the relationship of albuminuria with various CKD markers, its correlation with the urinary protein to creatinine ratio (UPC), and hypertension in dogs with early stages of CKD. It also sought to determine the usability of the urinary albumin to creatinine ratio (UAC) for CKD screening. METHODS: The study reviewed records of 102 dogs, categorising them into four groups based on disease status. UAC and UPC ratio, biochemistry and haematology variables, age, and systolic blood pressure were determined. RESULTS: The Pearson's correlation coefficient between log-transformed values of UPC and UAC was r = 0.902 (95% CI: 0.87 to 0.93). Median UAC ratio values were 2.1 mg/g for the Healthy control group (n = 17), 54.2 mg/g for early stages CKD (n = 42), 5.8 mg/g for Acute sick control (n = 30), and 104 mg/g for Chronic sick control (n = 13). Thresholding UAC ratio as an indicator for impaired kidney function with the threshold of 10 mg/g (established based on the receiver operating characteristic curve) had a sensitivity 81.8%, specificity of 89.4%, positive predictive value (PPV) 90%, and negative predictive value (NPV) 80.1%. The correlation of UAC with biochemistry and haematology variables was statistically significant; for SDMA (µg/L), it was r = 0.566 and for other variables, it was weak to moderate. UAC was markedly elevated in cases of severe hypertension. CONCLUSIONS: UAC ratio was significantly different among dogs with impaired and not impaired kidney function. The correlation strength for the UAC and UPC ratios was high. UAC ratio may be a promising marker for proteinuria analysis in dogs with CKD or other kidney function alterations.


Assuntos
Doenças do Cão , Hipertensão , Insuficiência Renal Crônica , Cães , Animais , Albuminúria/veterinária , Albuminúria/diagnóstico , Albuminúria/urina , Creatinina/urina , Insuficiência Renal Crônica/veterinária , Insuficiência Renal Crônica/urina , Proteinúria/veterinária , Hipertensão/urina , Hipertensão/veterinária , Doenças do Cão/diagnóstico
2.
Sci Transl Med ; 13(588)2021 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-33827977

RESUMO

Huntingtin (HTT)-lowering therapies hold promise to slow down neurodegeneration in Huntington's disease (HD). Here, we assessed the translatability and long-term durability of recombinant adeno-associated viral vector serotype 5 expressing a microRNA targeting human HTT (rAAV5-miHTT) administered by magnetic resonance imaging-guided convention-enhanced delivery in transgenic HD minipigs. rAAV5-miHTT (1.2 × 1013 vector genome (VG) copies per brain) was successfully administered into the striatum (bilaterally in caudate and putamen), using age-matched untreated animals as controls. Widespread brain biodistribution of vector DNA was observed, with the highest concentration in target (striatal) regions, thalamus, and cortical regions. Vector DNA presence and transgene expression were similar at 6 and 12 months after administration. Expression of miHTT strongly correlated with vector DNA, with a corresponding reduction of mutant HTT (mHTT) protein of more than 75% in injected areas, and 30 to 50% lowering in distal regions. Translational pharmacokinetic and pharmacodynamic measures in cerebrospinal fluid (CSF) were largely in line with the effects observed in the brain. CSF miHTT expression was detected up to 12 months, with CSF mHTT protein lowering of 25 to 30% at 6 and 12 months after dosing. This study demonstrates widespread biodistribution, strong and durable efficiency of rAAV5-miHTT in disease-relevant regions in a large brain, and the potential of using CSF analysis to determine vector expression and efficacy in the clinic.


Assuntos
Doença de Huntington , MicroRNAs , Animais , Modelos Animais de Doenças , Terapia Genética , Vetores Genéticos/genética , Humanos , Proteína Huntingtina/genética , Proteína Huntingtina/metabolismo , Doença de Huntington/genética , Doença de Huntington/terapia , MicroRNAs/metabolismo , Suínos , Porco Miniatura/metabolismo , Distribuição Tecidual
3.
BMC Vet Res ; 17(1): 45, 2021 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-33482816

RESUMO

BACKGROUND: Atrioventricular canal defect is a rare congenital disorder of the heart and describes the presence of an atrial septal defect, a variable presentation of ventricular septal alterations including ventricular septal defect malformations in the mitral and tricuspid valves. The defect has been described in human beings, dogs, cats, pigs, and horses. CASE PRESENTATION: This paper describes the case of a complete atrioventricular canal defect in a four-year-old intact male pet ferret (Mustela putorius furo), which was presented due to posterior weakness, ataxia, and decreased appetite. A loud systolic murmur, dyspnea, and hind limb paraparesis were detected during the clinical examination. Thoracic radiographs showed generalized cardiomegaly and lung edema. ECG showed sinus rhythm with prolonged P waves and QRS complexes. Echocardiography showed a large atrial septal defect, atrioventricular dysplasia, and a ventricular septal defect. Palliative treatment with oxygen, furosemide, spironolactone, enalapril, diltiazem, and supportive care was chosen as the therapy of choice. The ferret recovered gradually during hospitalization. A follow-up examination at three and six months showed stabilization of cardiac function. CONCLUSIONS: To the authors knowledge, this is the first time an atrioventricular canal defect has been described in a pet ferret.


Assuntos
Furões/anormalidades , Defeitos dos Septos Cardíacos/veterinária , Animais , Cardiomegalia/diagnóstico por imagem , Cardiomegalia/veterinária , Ecocardiografia/veterinária , Eletrocardiografia/veterinária , Defeitos dos Septos Cardíacos/diagnóstico por imagem , Defeitos dos Septos Cardíacos/terapia , Masculino , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/veterinária , Resultado do Tratamento
4.
Front Bioeng Biotechnol ; 8: 552357, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33344428

RESUMO

INTRODUCTION: Pulsed field ablation (PFA) exploits the delivery of short high-voltage shocks to induce cells death via irreversible electroporation. The therapy offers a potential paradigm shift for catheter ablation of cardiac arrhythmia. We designed an AC-burst generator and therapeutic strategy, based on the existing knowledge between efficacy and safety among different pulses. We performed a proof-of-concept chronic animal trial to test the feasibility and safety of our method and technology. METHODS: We employed 6 female swine - weight 53.75 ± 4.77 kg - in this study. With fluoroscopic and electroanatomical mapping assistance, we performed ECG-gated AC-PFA in the following settings: in the left atrium with a decapolar loop catheter with electrodes connected in bipolar fashion; across the interventricular septum applying energy between the distal electrodes of two tip catheters. After procedure and 4-week follow-up, the animals were euthanized, and the hearts were inspected for tissue changes and characterized. We perform finite element method simulation of our AC-PFA scenarios to corroborate our method and better interpret our findings. RESULTS: We applied square, 50% duty cycle, AC bursts of 100 µs duration, 100 kHz internal frequency, 900 V for 60 pulses in the atrium and 1500 V for 120 pulses in the septum. The inter-burst interval was determined by the native heart rhythm - 69 ± 9 bpm. Acute changes in the atrial and ventricular electrograms were immediately visible at the sites of AC-PFA - signals were elongated and reduced in amplitude (p < 0.0001) and tissue impedance dropped (p = 0.011). No adverse event (e.g., esophageal temperature rises or gas bubble streams) was observed - while twitching was avoided by addition of electrosurgical return electrodes. The implemented numerical simulations confirmed the non-thermal nature of our AC-PFA and provided specific information on the estimated treated area and need of pulse trains. The postmortem chest inspection showed no peripheral damage, but epicardial and endocardial discolorations at sites of ablation. T1-weighted scans revealed specific tissue changes in atria and ventricles, confirmed to be fibrotic scars via trichrome staining. We found isolated, transmural and continuous scars. A surviving cardiomyocyte core was visible in basal ventricular lesions. CONCLUSION: We proved that our method and technology of AC-PFA is feasible and safe for atrial and ventricular myocardial ablation, supporting their systematic investigation into effectiveness evaluation for the treatment of cardiac arrhythmia. Further optimization, with energy titration or longer follow-up, is required for a robust atrial and ventricular AC-PFA.

5.
Pacing Clin Electrophysiol ; 42(7): 862-867, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30989679

RESUMO

BACKGROUND: Choosing the appropriate animal model for development of novel technologies requires an understanding of anatomy and physiology of these different models. There are little data about the characteristics of different animal models for the study of technologies used for epicardial ablation. We aimed to compare the incidence of ventricular arrhythmias during epicardial radiofrequency ablation between swine and canine models using novel epicardial ablation catheters. METHODS: We conducted a retrospective study using data obtained from epicardial ablation experiments performed on swine (Sus Scrofa) and canine (Canis familiaris) models. We compared the incidence of ventricular arrhythmias during ablation between swine and canine using multivariate regression analysis. Six swine and six canine animals underwent successful epicardial radiofrequency ablation. A total of 103 ablation applications were recorded. RESULTS: Ventricular arrhythmias requiring cardioversion occurred in 13.11% of radiofrequency ablation applications in swine and 9.75% in canine (relative risk: 117.6%, 95% confidence interval [CI]: 83.97-164.69, animal-based odds ratio [OR]: .55, 95% CI: .23-61.33; P = .184). When adjusting for application position, duration of ablation and power, the odds of developing potentially lethal ventricular arrhythmia in swine increased significantly compared to canine (OR: 3.60, 95% CI: 1.35-9.55; P = .010). CONCLUSIONS: The swine myocardium is more susceptible to developing ventricular arrhythmias compared to canine model during epicardial ablation. This issue should be carefully considered in future studies.


Assuntos
Ablação por Cateter/métodos , Modelos Animais de Doenças , Pericárdio/cirurgia , Taquicardia Ventricular/etiologia , Animais , Cães , Incidência , Estudos Retrospectivos , Suínos
6.
Cardiovasc Intervent Radiol ; 42(5): 751-762, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30761413

RESUMO

PURPOSE: To compare the accumulation and effect of liposomal doxorubicin in liver tissue treated by radiofrequency ablation (RFA) and irreversible electroporation (IRE) in in vivo porcine models. MATERIALS AND METHODS: Sixteen RFA and 16 IRE procedures were performed in healthy liver of two groups of three pigs. Multi-tined RFA parameters included: 100 W, target temperature 105°C for 7 min. 100 IRE pulses were delivered using two monopolar electrodes at 2250 V, 1 Hz, for 100 µsec. For each group, two pigs received 50 mg liposomal doxorubicin (0.5 mg/kg) as a drip infusion during ablation procedure, with one pig serving as control. Samples were harvested from the central and peripheral zones of the ablation at 24 and 72 h. Immunohistochemical analysis to evaluate the degree of cellular stress, DNA damage, and degree of apoptosis was performed. These and the ablation sizes were compared. Doxorubicin concentrations were also analyzed using fluorescence photometry of homogenized tissue. RESULTS: RFA treatment zones created with concomitant administration of doxorubicin at 24 h were significantly larger than controls (2.5 ± 0.3 cm vs. 2.2 ± 0.2 cm; p = 0.04). By contrast, IRE treatment zones were negatively influenced by chemotherapy (2.2 ± 0.4 cm vs. 2.6 ± 0.4 cm; p = 0.05). At 24 h, doxorubicin concentrations in peripheral and central zones of RFA were significantly increased in comparison with untreated parenchyma (0.431 ± 0.078 µg/g and 0.314 ± 0.055 µg/g vs. 0.18 ± 0.012 µg/g; p < 0.05). Doxorubicin concentrations in IRE zones were not significantly different from untreated liver (0.191 ± 0.049 µg/g and 0.210 ± 0.049 µg/g vs. 0.18 ± 0.012 µg/g). CONCLUSIONS: Whereas there is an increased accumulation of periprocedural doxorubicin and an associated increase in ablation zone following RFA, a contrary effect is noted with IRE. These discrepant findings suggest that different mechanisms and synergies will need to be considered in order to select optimal adjuvants for different classes of ablation devices.


Assuntos
Doxorrubicina/análogos & derivados , Eletroporação/métodos , Fígado/cirurgia , Ablação por Radiofrequência/métodos , Animais , Doxorrubicina/administração & dosagem , Doxorrubicina/metabolismo , Feminino , Modelos Animais , Polietilenoglicóis/metabolismo , Suínos
7.
J Interv Card Electrophysiol ; 53(1): 105-113, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30008046

RESUMO

PURPOSE: To demonstrate the feasibility of directional percutaneous epicardial ablation using a partially insulated catheter. METHODS: Partially insulated catheter prototypes were tested in 12 (6 canine, 6 porcine) animal studies in two centers. Prototypes had interspersed windows to enable visualization of epicardial structures with ultrasound. Epicardial unipolar ablation and ablation between two electrodes was performed according to protocol (5-60 W power, 0-60 mls/min irrigation, 78 s mean duration). RESULTS: Of 96 epicardial ablation attempts, unipolar ablation was delivered in 53.1%. Electrogram evidence of ablation, when analyzable, occurred in 75 of 79 (94.9%) therapies. Paired pre/post-ablation pacing threshold (N = 74) showed significant increase in pacing threshold post-ablation (0.9 to 2.6 mA, P < .0001). Arrhythmias occurred in 18 (18.8%) therapies (11 ventricular fibrillation, 7 ventricular tachycardia), mainly in pigs (72.2%). Coronary artery visualization was variably successful. No phrenic nerve injury was noted during or after ablation. Furthermore, there were minimal pericardial changes with ablation. CONCLUSIONS: Epicardial ablation using a partially insulated catheter to confer epicardial directionality and protect the phrenic nerve seems feasible. Iterations with ultrasound windows may enable real-time epicardial surface visualization thus identifying coronary arteries at ablation sites. Further improvements, however, are necessary.


Assuntos
Ablação por Cateter/instrumentação , Desenho de Equipamento , Complicações Intraoperatórias/prevenção & controle , Nervo Frênico/lesões , Taquicardia Ventricular/cirurgia , Animais , Área Sob a Curva , Cateteres Cardíacos , Ablação por Cateter/métodos , Modelos Animais de Doenças , Cães , Estudos de Viabilidade , Feminino , Distribuição Aleatória , Sensibilidade e Especificidade , Suínos , Taquicardia Ventricular/diagnóstico por imagem
8.
JACC Clin Electrophysiol ; 3(7): 747-755, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28736750

RESUMO

INTRODUCTION: Epicardial defibrillation systems currently require surgical access. We aimed to develop a percutaneous defibrillation system with partially-insulated epicardial coils to focus electrical energy on the myocardium and prevent or minimize extra-cardiac stimulation. METHODS: We tested 2 prototypes created for percutaneous introduction into the pericardial space via a steerable sheath. This included a partially-insulated defibrillation coil and a defibrillation mesh with a urethane balloon acting as an insulator to the face of the mesh not in contact with the epicardium. The average energy associated with a chance of successful defibrillation 75% of the time (ED75) was calculated for each experiment. RESULTS: Of 16 animal experiments, 3 pig experiments had malfunctioning mesh prototypes such that results were unreliable; these were excluded. Therefore, 13 animal experiments were analyzed - 6 canines (29.8±4.0kg); 7 pigs (41.1±4.4kg). The overall ED75 was 12.8±6.7J (10.9±9.1J for canines; 14.4±3.9J in pigs [P=0.37]). The lowest ED75 obtained in canines was 2.5J while in pigs it was 9.5J. The lowest energy resulting in successful defibrillation was 2J in canines and 5J in pigs. There was no evidence of coronary vessel injury or trauma to extra-pericardial structures. CONCLUSION: Percutaneous, epicardial defibrillation using a partially insulated coil is feasible and appears to be associated with low defibrillation thresholds. Focusing insulation may limit extra-cardiac stimulation and potentially lower energy requirements for efficient defibrillation.


Assuntos
Desfibriladores , Animais , Cães , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Feminino , Masculino , Pericárdio , Suínos
9.
J Surg Res ; 193(2): 606-12, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25201575

RESUMO

BACKGROUND: Treatment or prevention of a benign biliary tree stricture is an unresolved problem. A novel self-expandable biodegradable polydioxanon biliary stent in a porcine model was studied. MATERIALS AND METHODS: This new stent was used in 23 pigs. Feasibility and safety of surgical stenting, time of biodegradation, and histologic reaction in 2, 8, 13, and 20 wk of a follow-up were studied. All stents were inserted into a common bile duct through a duodenal papilla following small dilatation. After surgical evaluation of abdominal cavities, the pigs were sacrificed to remove common bile ducts with the stents. All bile ducts were assessed by macroscopic and histopathologic examination. RESULTS: Self-expansion was correct in all cases. Neither bile duct obstruction nor postsurgical complications were observed. Macroscopic evaluation indicated lightening of the stent color in 2 wk, a partial disintegration in 8 wk, and a complete absorption in 13 and 20 wk. Histologic evaluation in general substantiated a mild-to-moderate inflammatory reaction in the lamina propria during the whole follow up and had no clinical consequences. No cholangitis, necrosis, abscess, or excessive fibroplasia was found in a hepatoduodenal ligament. CONCLUSIONS: Our results suggest that polydioxanon biodegradable self-expanding stents seem to be useful for biliary system implantation, offer a good biocompatibility, and completely degrade within 13 wk.


Assuntos
Doenças dos Ductos Biliares/cirurgia , Procedimentos Cirúrgicos do Sistema Biliar/instrumentação , Stents , Animais , Materiais Biocompatíveis , Constrição Patológica/cirurgia , Estudos de Viabilidade , Feminino , Suínos
10.
Biomed Res Int ; 2014: 532792, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24812620

RESUMO

The aim of this study is to inform about the development of a new semispherical surgical instrument for the bipolar multielectrode radiofrequency liver ablation. Present tools are universal; however they have several disadvantages such as ablation of healthy tissue, numerous needle punctures, and, therefore, longer operating procedure. Our newly designed and tested semispherical surgical tool can solve some of these disadvantages. By conducting an in vivo study on a set of 12 pigs, randomly divided into two groups, we have compared efficiency of the newly developed instrument with the commonly used device. Statistical analysis showed that there were no significant differences between the groups. On average, the tested instrument RONJA had shorter ablation time in both liver lobes and reduced the total operating time. The depth of the thermal alteration was on average 4 mm larger using the newly tested instrument. The new radiofrequency method described in this study could be used in open liver surgery for the treatment of small liver malignancies (up to 2 cm) in a single application with the aim of saving healthy liver parenchyma. Further experimental studies are needed to confirm these results before clinical application of the method in the treatment of human liver malignancies.


Assuntos
Ablação por Cateter/instrumentação , Fígado/cirurgia , Animais , Biópsia , Eletrodos , Técnicas In Vitro , Fígado/patologia , Sus scrofa , Termografia
11.
J Thorac Cardiovasc Surg ; 143(2): 437-44, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21885070

RESUMO

OBJECTIVE: This study was undertaken to evaluate safety and biocompatibility of a novel biodegradable polydioxanone stent in a rabbit tracheal model. Metallic and silicone stents represent standard therapeutic approaches for hollow organ stenosis, although complications have been reported repeatedly. Biodegradable stents could reduce the risks associated with this procedure while still achieving the purpose of maintaining lumen patency. METHODS: A commercially available polydioxanone suture strand with a long safety record was used to manufacture the self-expanding stents. The polydioxanone stents were then implanted bronchoscopically and under fluoroscopic guidance into the tracheas of white rabbits (N = 25). Periodic clinical examination was performed. Histopathologic examination concluded the study for the 5 experimental groups at 3, 4, 5, 10, and 15 weeks after implantation. RESULTS: There were no unexpected deaths and no stent displacements during the study. The animals remained in good condition, without stent debris expectoration. Macroscopic examination revealed that the tracheal lumen stayed open. Histologic examination showed that tracheal damage score was highest 5 weeks after stenting, including in-stent necrosis of the epithelium. Stent degradation was complete with no remnants after 10 weeks, leaving the trachea completely healed at 15 weeks after implantation. CONCLUSIONS: This animal airway model has demonstrated acceptable safety and biocompatibility of this novel biodegradable polydioxanone stent. We suggest that polydioxanone stenting be used for further clinical studies for cases in which complete stent degradation after temporary airway treatment is desirable.


Assuntos
Implantes Absorvíveis , Broncoscopia/instrumentação , Polidioxanona , Stents , Traqueia/cirurgia , Animais , Broncoscopia/efeitos adversos , Feminino , Fluoroscopia , Teste de Materiais , Modelos Animais , Desenho de Prótese , Coelhos , Radiografia Intervencionista/métodos , Fatores de Tempo , Traqueia/diagnóstico por imagem , Traqueia/patologia
12.
J Vet Dent ; 25(4): 231-5, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19271410

RESUMO

This study compared several techniques of manual and power instrument supragingival scaling and subsequent polishing with different methods. Observations were made to determine if there was an optimal method of enamel surface treatment based on the efficacy of the polishing and damage to the enamel. The maxillary fourth premolar and canine teeth were used as experimental teeth. These teeth were extracted after treatment and immersed in 10% buffered formalin solution for further processing and evaluation using electron microscopy. Our observations indicated that the most effective method for scaling and enamel protection during periodontal treatment was provided by power instrumentation followed by polishing using a soft polishing wheel with pumice paste.


Assuntos
Placa Dentária/veterinária , Raspagem Dentária/veterinária , Doenças do Cão/prevenção & controle , Doenças Periodontais/veterinária , Dente/ultraestrutura , Animais , Placa Dentária/prevenção & controle , Raspagem Dentária/instrumentação , Raspagem Dentária/métodos , Cães , Gengivite/prevenção & controle , Gengivite/veterinária , Microscopia Eletrônica de Varredura/veterinária , Doenças Periodontais/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA