1.
Appl Spectrosc ; : 37028241246010, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38634156

RESUMO

Fentanyl and fentanyl analogs are the main cause of recent overdose deaths in the United States. The presence of fentanyl analogs in illicit drugs makes it difficult to estimate their potencies. This makes the detection and differentiation of fentanyl analogs critically significant. Surface-enhanced Raman spectroscopy (SERS) can differentiate structurally similar fentanyl analogs by yielding spectroscopic fingerprints for the detected molecules. In previous years, five fentanyl analogs, carfentanil, furanyl fentanyl, acetyl fentanyl, 4-fluoroisobutyryl fentanyl (4-FIBF), and cyclopropyl fentanyl (CPrF), gained popularity and were found in 76.4% of the fentanyl analogs trafficked. In this study, we focused on 4-FIBF, CPrF, and structurally similar fentanyl analogs. We developed methods to differentiate these fentanyl analogs using theoretical and experimental methods. To do this, a set of fentanyl analogs were examined using density functional theory (DFT) calculations. The DFT results obtained in this project permitted the assignment of spectral bands. These results were then compared with normal Raman and SERS techniques. Structurally similar fentanyl analogs show important differences in their spectra, and they have been visually differentiated from each other both theoretically and experimentally. Additional results using principal component analysis and soft independent modeling of class analogy show they can be distinguished using this technique. The limit of detection values for FIBF and CPrF were determined to be 0.35 ng/mL and 4.4 ng/mL, respectively, using SERS. Experimental results obtained in this project can be readily implemented in field applications and smaller laboratories, where inexpensive portable Raman spectrometers are often present and used in drug analysis.

2.
Phytochem Anal ; 34(5): 518-527, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37139918

RESUMO

INTRODUCTION: Process analytical technology (PAT) guidance is implemented in the quality assurance of phytocompounds to achieve the Industry 4.0 concept. Near-infrared (NIR) and Raman spectroscopies are feasible for rapid, reliable quantitative analysis through transparent packaging without removing the samples from their original containers. These instruments can serve PAT guidance. OBJECTIVE: This study aimed to develop online portable NIR and Raman spectroscopic methods for quantifying total curcuminoids in turmeric samples through a plastic bag. The method mimicked an in-line measurement mode in PAT compared with placing samples into a glass vessel (at-line mode). MATERIALS AND METHODS: Sixty-three curcuminoid standard-spiked samples were prepared. Then, 15 samples were randomly selected as fixed validation samples, and 40 of the 48 remaining samples were chosen as calibration set. The results obtained from the partial least square regression (PLSR) models constructed by using the spectra acquired from NIR and Raman were compared with the reference values from high-performance liquid chromatography (HPLC). RESULTS: The optimum PLSR model of at-line Raman was achieved with three latent variables and a root mean square error of prediction (RMSEP) of 0.46. Meanwhile, the PLSR model of at-line NIR with one latent variable offered an RMSEP of 0.43. For the in-line mode, PLSR models created from Raman and NIR spectra had one latent variable with RMSEP of 0.49 and 0.42, respectively. The R2 values for prediction were 0.88-0.92. CONCLUSION: The models established from the spectra from portable NIR and Raman spectroscopic devices with the appropriate spectral pretreatments allowed the determination of total curcuminoid contents through plastic bag.


Assuntos
Curcuma , Espectroscopia de Luz Próxima ao Infravermelho , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Curcuma/química , Pós , Controle de Qualidade , Diarileptanoides , Análise dos Mínimos Quadrados , Calibragem , Plásticos
3.
Foods ; 11(15)2022 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-35892772

RESUMO

Turmeric consumption is continually increasing worldwide. Curcuminoids are major active constituents in turmeric and are associated with numerous health benefits. A combination of spectroscopic methods and chemometrics shows the suitability of turmeric for food quality control due to advantages such as speed, versatility, portability, and no need for sample preparation. Five calibration models to quantify curcuminoids in turmeric were proposed using benchtop and portable devices. The most remarkable results showed that Raman and NIR calibration models present an excellent performance reporting RMSEP of 0.44% w/w and 0.41% w/w, respectively. In addition, the five proposed methods (FT-IR, Raman, and NIR) were compared in terms of precision and accuracy. The results showed that benchtop and portable methods were in good agreement and that there are no significant differences between them. This study aims to foster the use of portable devices for food quality control in situ by demonstrating their suitability for the purpose.

4.
J Genet Couns ; 30(3): 693-700, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33142000

RESUMO

Rare diseases (RDs) as a whole affect a huge number of individuals although each specific condition comprises a low number of individuals. As a consequence, funds allocated to expand research to all conditions are often limited. Several initiatives have emerged to invest more resources for research in RDs, but patients express unmet needs regarding educational initiatives, awareness support, and psychosocial resources. We developed an educational training program in the format of weekly sessions covering basic medical scientific knowledge and psychosocial aspects of RDs. The aim of this initiative was to assess its overall impact regarding knowledge, psychological issues, and participant satisfaction. Items were evaluated through surveys before and after the sessions. Here, we report the experience and impact of two editions of this initiative with a total of 37 participants. Our results show improvements in knowledge and better management of the psychological impact. Moreover, participants were able to exchange experiences and concerns, most of which were shared even though the RDs were different. Overall, the program was evaluated by the participants as a highly beneficial experience and all of them were interested in attending advanced editions.


Assuntos
Doenças Raras , Escolaridade , Humanos , Inquéritos e Questionários
5.
Orphanet J Rare Dis ; 14(1): 254, 2019 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-31727109

RESUMO

BACKGROUND: Mucopolysaccharidosis type VII (Sly disease, MPS VII), is an ultra-rare, multi-symptom disease with variable clinical presentations which can present challenges with diagnosis, management and care. We believe this survey is the first to explore the patient experience through direct questioning of the caregivers of 13 individuals with MPS VII. METHODS: This European survey, using a specifically designed questionnaire, was conducted in order to describe the pathway to diagnosis and the burden of illness of MPS VII. Information on early symptoms, clinicians seen, and current symptoms was collected. Questions on the caregivers' ability to work and the use and availability of health, social and educational support were included. RESULTS: Caregivers of 13 patients from Germany, Spain, The Netherlands and Turkey responded to the survey. Five patients with non-immune hydrops fetalis (NIHF) were diagnosed with MPS VII at a mean age of 1.9 years (median 0.3 years, range 0.2 to 6 years). Those without NIHF (n = 7) were diagnosed at a mean age of 6.1 years (median 6.0 years, range 1.9 to 14 years). The symptoms most likely to raise a suspicion of MPS VII, excluding NIHF, did not appear until a median age of at least three years. Over one half of patients required assistance with daily living and mobility. Reduction of the working hours of caregivers was often necessary (46.2% reduced hours, 30.8% stopped working). Patients attended frequent medical appointments (12.7/year), over 80% had surgery and 30% had been hospitalised for respiratory issues. While support for learning and behavioural needs was generally available, support for mobility was not available to 50% of patients. Half of the respondents (6/12) said they were not offered genetic counselling. CONCLUSIONS: For children that do not present with NIHF, diagnosis can take several years as early symptoms can be non-specific and mistaken for other conditions. Increased awareness of the early signs of disease and more information for parents/caregivers at diagnosis are needed. MPS VII poses significant burden to patients, caregivers, healthcare, social and educational services. Access to information and support varies across Europe and the availability of genetic counselling is limited in some countries.


Assuntos
Cuidadores/estatística & dados numéricos , Mucopolissacaridose VII/diagnóstico , Mucopolissacaridose VII/economia , Adolescente , Adulto , Efeitos Psicossociais da Doença , Europa (Continente) , Feminino , Alemanha , Humanos , Masculino , Países Baixos , Espanha , Inquéritos e Questionários , Turquia , Adulto Jovem
6.
J Pharm Anal ; 2(2): 90-97, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29403727

RESUMO

The growing interest of the pharmaceutical industry in Near Infrared-Chemical Imaging (NIR-CI) is a result of its high usefulness for quality control analyses of drugs throughout their production process (particularly of its non-destructive nature and expeditious data acquisition). In this work, the concentration and distribution of the major and minor components of pharmaceutical tablets are determined and the spatial distribution from the internal and external sides has been obtained. In addition, the same NIR-CI allowed the coating thickness and its surface distribution to be quantified. Images were processed to extract the target data and calibration models constructed using the Partial Least Squares (PLS) algorithms. The concentrations of Active Pharmaceutical Ingredient (API) and excipients obtained for uncoated cores were essentially identical to the nominal values of the pharmaceutical formulation. But the predictive ability of the calibration models applied to the coated tablets decreased as the coating thickness increased.

7.
Talanta ; 80(2): 473-8, 2009 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-19836506

RESUMO

Near Infrared Chemical Imaging (NIR-CI) is demonstrating an increasing interest in pharmaceutical research since it meets the challenging analytical needs of pharmaceutical quality and may serve as a versatile adjunct to conventional NIR spectroscopy in many fields. The direct analysis of samples by using hyperspectral imaging techniques, which provide a NIR spectrum in each pixel of the image, generates a big amount of information from one sample. Focusing the interest in pharmaceutical research, several chemometric algorithms are demonstrating their usefulness extracting the relevant information (i.e. quantitative determination of the component in one sample) in tablets with only one sample and without damaging it. In this work, a quantitative method to analyze different commercial Acetylsalicylic acid tablets is proposed by using Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) method to the hyperspectral image and without any previous calibration model. For this purpose, a large concentration range of active pharmaceutical ingredient (ASA, Acetylsalicylic acid in this work), between 82% and 12%, was covered depending on the manufacturer. MCR-ALS allowed obtaining a concentration maps for acetylsalicylic acid and therefore, consequent analysis of the ASA distribution in the tablet was developed by using the histograms of the distribution of concentration. Results certified the good distribution of ASA despite the different origins of the tablets. Moreover, the obtained values of concentration showed a very good concordance with the nominal value of ASA. As a matter of fact, the quality of the results demonstrated the useful of encompassing NIR-CI techniques with MCR-ALS and, consequently, the well development on the production of Acetylsalicylic acid tablets.


Assuntos
Aspirina/análise , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Tecnologia Farmacêutica/métodos , Anti-Inflamatórios não Esteroides/análise , Aspirina/química , Química Farmacêutica/métodos , Análise dos Mínimos Quadrados , Análise Multivariada , Reprodutibilidade dos Testes , Comprimidos