Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 168
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39032032

RESUMO

INTRODUCTION: The emergence of handheld ultrasound devices capable of connecting to cell phones or tablets heralds a significant advancement in medical technology, particularly within the field of obstetrics. These devices offer the promise of immediate bedside ultrasound examinations, potentially revolutionizing patient care by enabling fetal assessments in diverse settings. MATERIAL AND METHODS: This prospective study aimed to validate the reliability of non-piezo, chip-based handheld ultrasound devices in clinical obstetric practice. Conducted in a university hospital obstetric ward, the study included 100 pregnant women between 17 and 41 weeks of gestation. Participants underwent ultrasound examinations using both conventional and portable point-of-care ultrasound (POCUS) devices to compare the accuracy in estimating fetal weight and other parameters, such as cardiac activity, fetal presentation, placental location, and amniotic fluid volume. The reliability and agreement between the devices were assessed using intraclass correlation coefficients, Bland-Altman plots, and Pearson correlation coefficients. RESULTS: The results show a near-perfect agreement (0.98) and correlation (r = 0.98, p < 0.001) for estimated fetal weight and most biometry measurements between the two types of ultrasound devices, with slight deviations in head circumference and amniotic fluid index measurements. Subgroup analysis revealed variations in agreement and correlation rates with higher BMI and advanced gestational age, indicating areas for further refinement. CONCLUSIONS: These findings affirm the high reliability of handheld ultrasound devices for basic obstetric ultrasound evaluations, supporting their integration into daily clinical practice. This technology improves the flexibility and immediacy of prenatal care, although further research is needed to optimize its application across patient populations and treatment settings.

2.
Transl Res ; 273: 58-77, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39025226

RESUMO

Cardiac fibrosis occurs following insults to the myocardium and is characterized by the abnormal accumulation of non-compliant extracellular matrix (ECM), which compromises cardiomyocyte contractile activity and eventually leads to heart failure. This phenomenon is driven by the activation of cardiac fibroblasts (cFbs) to myofibroblasts and results in changes in ECM biochemical, structural and mechanical properties. The lack of predictive in vitro models of heart fibrosis has so far hampered the search for innovative treatments, as most of the cellular-based in vitro reductionist models do not take into account the leading role of ECM cues in driving the progression of the pathology. Here, we devised a single-step decellularization protocol to obtain and thoroughly characterize the biochemical and micro-mechanical properties of the ECM secreted by activated cFbs differentiated from human induced pluripotent stem cells (iPSCs). We activated iPSC-derived cFbs to the myofibroblast phenotype by tuning basic fibroblast growth factor (bFGF) and transforming growth factor beta 1 (TGF-ß1) signalling and confirmed that activated cells acquired key features of myofibroblast phenotype, like SMAD2/3 nuclear shuttling, the formation of aligned alpha-smooth muscle actin (α-SMA)-rich stress fibres and increased focal adhesions (FAs) assembly. Next, we used Mass Spectrometry, nanoindentation, scanning electron and confocal microscopy to unveil the characteristic composition and the visco-elastic properties of the abundant, collagen-rich ECM deposited by cardiac myofibroblasts in vitro. Finally, we demonstrated that the fibrotic ECM activates mechanosensitive pathways in iPSC-derived cardiomyocytes, impacting on their shape, sarcomere assembly, phenotype, and calcium handling properties. We thus propose human bio-inspired decellularized matrices as animal-free, isogenic cardiomyocyte culture substrates recapitulating key pathophysiological changes occurring at the cellular level during cardiac fibrosis.

3.
Front Neuroergon ; 5: 1382919, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38784138

RESUMO

Introduction: Sleep-wake cycle disruption caused by shift work may lead to cardiovascular stress, which is observed as an alteration in the behavior of heart rate variability (HRV). In particular, HRV exhibits complex patterns over different time scales that help to understand the regulatory mechanisms of the autonomic nervous system, and changes in the fractality of HRV may be associated with pathological conditions, including cardiovascular disease, diabetes, or even psychological stress. The main purpose of this study is to evaluate the multifractal-multiscale structure of HRV during sleep in healthy shift and non-shift workers to identify conditions of cardiovascular stress that may be associated with shift work. Methods: The whole-sleep HRV signal was analyzed from female participants: eleven healthy shift workers and seven non-shift workers. The HRV signal was decomposed into intrinsic mode functions (IMFs) using the empirical mode decomposition method, and then the IMFs were analyzed using the multiscale-multifractal detrended fluctuation analysis (MMF-DFA) method. The MMF-DFA was applied to estimate the self-similarity coefficients, α(q, τ), considering moment orders (q) between -5 and +5 and scales (τ) between 8 and 2,048 s. Additionally, to describe the multifractality at each τ in a simple way, a multifractal index, MFI(τ), was computed. Results: Compared to non-shift workers, shift workers presented an increase in the scaling exponent, α(q, τ), at short scales (τ < 64 s) with q < 0 in the high-frequency component (IMF1, 0.15-0.4 Hz) and low-frequency components (IMF2-IMF3, 0.04-0.15 Hz), and with q> 0 in the very low frequencies (IMF4, < 0.04 Hz). In addition, at large scales (τ> 1,024 s), a decrease in α(q, τ) was observed in IMF3, suggesting an alteration in the multifractal dynamic. MFI(τ) showed an increase at small scales and a decrease at large scales in IMFs of shift workers. Conclusion: This study helps to recognize the multifractality of HRV during sleep, beyond simply looking at indices based on means and variances. This analysis helps to identify that shift workers show alterations in fractal properties, mainly on short scales. These findings suggest a disturbance in the autonomic nervous system induced by the cardiovascular stress of shift work.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38780288

RESUMO

INTRODUCTION: Prenatal lower urinary tract obstruction (LUTO) is a rare and challenging condition with potential severe morbidity and mortality. Prenatal shunting methods, specifically vesicoamniotic shunting (VAS) and fetal cystoscopy, aim to manage this condition. However, comprehensive education and training are hindered by the rarity of LUTO. To address this gap, we present a low-cost 3D-printed ultrasound training model for VAS in LUTO fetuses. The aim of the study was to evaluate ultrasound and haptic fidelity of the model. MATERIAL AND METHODS: Ultrasound images of three LUTO fetuses at 12-14 weeks were utilized to create detailed 3D-printed models. Fusion360TM software generated stereo-lithography files, and the Formlabs Form3® printer, using Flexible 80A resin, produced the models. A simulation box mimicking uterine conditions and fetal anatomy was developed for testing. Ultrasound assessments determined model accuracy, and expert evaluations gauged fidelity for VAS placement. RESULTS: The 3D-printed model accurately replicated LUTO fetal anatomy, demonstrating structural integrity and realistic sonographic and haptic feedback during 20 punctures. Macroscopic visualization confirmed the model's durability and authenticity. DISCUSSION: This innovative 3D-printed model addresses the scarcity of LUTO cases and the lack of realistic training tools. Simulation models enhance skills, providing a controlled learning environment that bridges theoretical knowledge and clinical application, potentially improving patient outcomes. CONCLUSIONS: The 3D-printed training model for VAS in LUTO represents a significant advancement in surgical education, offering realistic anatomical simulation and tactile feedback. Future studies should assess its effectiveness in enhancing surgical skills and impacting patient outcomes in clinical practice.

5.
Arch Gynecol Obstet ; 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38796557

RESUMO

BACKGROUND: We used two 3D ultrasound volumes of fetal heads at 13 weeks to create live-size 3D-printed phantoms with a view to training or assessment of diagnostic abilities for normal and abnormal nuchal translucency measurements. The phantoms are suitable for use in a water bath, imitating a real-life exam. They were then used to study measurement accuracy and reproducibility in examiners of different skill levels. METHODS: Ultrasound scans of a 13 + 0-week fetus were processed using 3D Slicer software, producing a stereolithography file for 3D printing. The model, crafted in Autodesk Fusion360™, adhered to FMF guidelines for NT dimensions (NT 2.3 mm). Additionally, a model with pathologic NT was designed (NT 4.2 mm). Printing was performed via Formlabs Form 3® printer using High Temp Resin V2. The externally identical looking 3D models were embedded in water-filled condoms for ultrasound examination. Eight specialists of varying expertise levels conducted five NT measurements for each model, classifying them in physiological and abnormal models. RESULTS: Classification of the models in physiological or abnormal NT resulted in a detection rate of 100%. Average measurements for the normal NT model and the increased NT model were 2.27 mm (SD ± 0.38) and 4.165 mm (SD ± 0.51), respectively. The interrater reliability was calculated via the intraclass correlation coefficient (ICC) which yielded a result of 0.883, indicating robust agreement between the raters. Cost-effectiveness analysis demonstrated the economical nature of the 3D printing process. DISCUSSION: This study underscores the potential of 3D printed fetal models for enhancing ultrasound training through high inter-rater reliability, consistency across different expert levels, and cost-effectiveness. Limitations, including population variability and direct translation to clinical outcomes, warrant further exploration. The study contributes to ongoing discussions on integrating innovative technologies into medical education, offering a practical and economical method to acquire, refine and revise diagnostic skills in prenatal ultrasound. Future research should explore broader applications and long-term economic implications, paving the way for transformative advancements in medical training and practice.

6.
Cell Syst ; 15(3): 246-263.e7, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38366601

RESUMO

Autoinhibition is a prevalent allosteric regulatory mechanism in signaling proteins. Reduced autoinhibition underlies the tumorigenic effect of some known cancer drivers, but whether autoinhibition is altered generally in cancer remains elusive. Here, we demonstrate that cancer-associated missense mutations, in-frame insertions/deletions, and fusion breakpoints are enriched within inhibitory allosteric switches (IASs) across all cancer types. Selection for IASs that are recurrently mutated in cancers identifies established and unknown cancer drivers. Recurrent missense mutations in IASs of these drivers are associated with distinct, cancer-specific changes in molecular signaling. For the specific case of PPP3CA, the catalytic subunit of calcineurin, we provide insights into the molecular mechanisms of altered autoinhibition by cancer mutations using biomolecular simulations, and demonstrate that such mutations are associated with transcriptome changes consistent with increased calcineurin signaling. Our integrative study shows that autoinhibition-modulating genetic alterations are positively selected for by cancer cells.


Assuntos
Calcineurina , Neoplasias , Humanos , Calcineurina/genética , Neoplasias/genética , Mutação/genética , Carcinogênese , Mutação de Sentido Incorreto/genética
7.
Adv Sci (Weinh) ; 11(2): e2302965, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37946710

RESUMO

Interactions between living cells and nanoparticles are extensively studied to enhance the delivery of therapeutics. Nanoparticles size, shape, stiffness, and surface charge are regarded as the main features able to control the fate of cell-nanoparticle interactions. However, the clinical translation of nanotherapies has so far been limited, and there is a need to better understand the biology of cell-nanoparticle interactions. This study investigates the role of cellular mechanosensitive components in cell-nanoparticle interactions. It is demonstrated that the genetic and pharmacologic inhibition of yes-associated protein (YAP), a key component of cancer cell mechanosensing apparatus and Hippo pathway effector, improves nanoparticle internalization in triple-negative breast cancer cells regardless of nanoparticle properties or substrate characteristics. This process occurs through YAP-dependent regulation of endocytic pathways, cell mechanics, and membrane organization. Hence, the study proposes targeting YAP may sensitize triple-negative breast cancer cells to chemotherapy and increase the selectivity of nanotherapy.


Assuntos
Nanopartículas , Neoplasias de Mama Triplo Negativas , Humanos , Transdução de Sinais/fisiologia , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Neoplasias de Mama Triplo Negativas/metabolismo , Proteínas de Sinalização YAP
8.
Matrix Biol ; 125: 12-30, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37944712

RESUMO

Extracellular matrix (ECM) tumorigenic alterations resulting in high matrix deposition and stiffening are hallmarks of adenocarcinomas and are collectively defined as desmoplasia. Here, we thoroughly analysed primary prostate cancer tissues obtained from numerous patients undergoing radical prostatectomy to highlight reproducible structural changes in the ECM leading to the loss of the glandular architecture. Starting from patient cells, we established prostate cancer tumoroids (PCTs) and demonstrated they require TGF-ß signalling pathway activity to preserve phenotypical and structural similarities with the tissue of origin. By modulating TGF-ß signalling pathway in PCTs, we unveiled its role in ECM accumulation and remodelling in prostate cancer. We also found that TGF-ß-induced ECM remodelling is responsible for the initiation of prostate cell epithelial-to-mesenchymal transition (EMT) and the acquisition of a migratory, invasive phenotype. Our findings highlight the cooperative role of TGF-ß signalling and ECM desmoplasia in prompting prostate cell EMT and promoting tumour progression and dissemination.


Assuntos
Neoplasias da Próstata , Fator de Crescimento Transformador beta , Masculino , Humanos , Fator de Crescimento Transformador beta/metabolismo , Transição Epitelial-Mesenquimal , Neoplasias da Próstata/patologia , Matriz Extracelular/metabolismo , Próstata/metabolismo , Linhagem Celular Tumoral
9.
Clin Infect Dis ; 78(3): 667-673, 2024 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-37768207

RESUMO

BACKGROUND: Isoniazid preventive therapy (IPT) is recommended for tuberculosis prevention yet data on the safety of first-trimester pregnancy exposure are limited. METHODS: Planned secondary analysis in a TB prevention trial of adverse pregnancy outcomes among participants assigned to 9-month IPT who became pregnant during (IPT-exposed) or after (unexposed) IPT. Regression models compared binary outcomes of a composite adverse outcome (any non-live birth, excluding induced abortion); preterm delivery <37 weeks; and low birth weight <2500 g) among exposure groups. Models were adjusted for latent TB infection, maternal age, CD4 count, and antiretroviral therapy (ART). RESULTS: In total, 128 participants had a known pregnancy outcome; 39 IPT-exposed and 89 unexposed. At pregnancy outcome, ART use was lower in IPT-exposed (79%) than unexposed women (98%). Overall, 29 pregnancies ended in a composite adverse outcome (25 spontaneous abortions, 2 stillbirths and 2 ectopic pregnancies), 15 preterm deliveries, and 10 infants with low birth weight. IPT was associated with the composite adverse outcome adjusting for covariates at enrollment (adjusted relative risk [aRR] 1.98; 95% confidence interval [CI] 1.15, 3.41), but the effect was attenuated when adjusted for covariates at pregnancy outcome (aRR 1.47; 95% CI .84, 2.55); IPT was not associated with preterm delivery (relative risk [RR] 0.87; 95% CI .32-2.42) or low birth weight (RR 1.01; 95% CI .29, 3.56). CONCLUSIONS: First-trimester IPT exposure was associated with nearly two-fold increased risk of fetal demise, mostly spontaneous abortion, though the association was attenuated when adjusted for covariates proximal to pregnancy outcome including ART use. Further study is needed to inform TB prevention guidelines.


Assuntos
Aborto Espontâneo , Infecções por HIV , Nascimento Prematuro , Tuberculose , Recém-Nascido , Lactente , Gravidez , Feminino , Humanos , Isoniazida/efeitos adversos , Resultado da Gravidez , Tuberculose/tratamento farmacológico , HIV , Primeiro Trimestre da Gravidez , Antituberculosos/efeitos adversos , Nascimento Prematuro/epidemiologia , Infecções por HIV/tratamento farmacológico , Infecções por HIV/prevenção & controle , Infecções por HIV/complicações , Aborto Espontâneo/epidemiologia , Aborto Espontâneo/induzido quimicamente
10.
J Interferon Cytokine Res ; 44(2): 60-67, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38153389

RESUMO

Coronavirus disease 2019 (COVID-19) is caused by Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV2). COVID-19 can cause a cytokine release syndrome in which cytokines, including interleukin 17 (IL-17), are massively secreted in response to a specific stimulus. This can contribute to mortality and severe forms of COVID-19. The study aimed to determine the association of SARS-CoV2 infection with the IL-17A rs2275913 and IL-17F rs763780 variants, as well as with the associated comorbidities in COVID-19-positive Mexican patients. The study included 178 patients positive to COVID-19 and 177 COVID-19 negative subjects. For genotyping, the samples were amplified with a TaqMan® probe. There was no association between the AA genotype and A allele of IL-17A variant or the IL-17F C allele with the presence of COVID-19. In regard to comorbidities, a statistically significant association was found between IL-17A rs2275913 AA genotype and hypertension, as well as with the presence of obesity (P = 0.003, OR 23, 95% CI: 2.97-178.092 and P = 0.025, OR 28, 95% CI: 1.52-178.029, respectively) in patients with COVID-19. In conclusion, rs2275913 IL-17A polymorphism in COVID-19 patients seems to confer a higher susceptibility to the presence of hypertension and obesity, increasing the risk of premature cardiovascular disease in this population. However, more studies should be conducted for a better understanding of their relation.


Assuntos
COVID-19 , Hipertensão , Interleucina-17 , Obesidade , Humanos , Estudos de Casos e Controles , COVID-19/complicações , COVID-19/genética , Predisposição Genética para Doença , Genótipo , Hipertensão/complicações , Hipertensão/genética , Interleucina-17/genética , Obesidade/complicações , Obesidade/genética , Polimorfismo de Nucleotídeo Único
11.
J Clin Med ; 12(21)2023 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-37959298

RESUMO

Artificial intelligence (AI) has gained prominence in medical imaging, particularly in obstetrics and gynecology (OB/GYN), where ultrasound (US) is the preferred method. It is considered cost effective and easily accessible but is time consuming and hindered by the need for specialized training. To overcome these limitations, AI models have been proposed for automated plane acquisition, anatomical measurements, and pathology detection. This study aims to overview recent literature on AI applications in OB/GYN US imaging, highlighting their benefits and limitations. For the methodology, a systematic literature search was performed in the PubMed and Cochrane Library databases. Matching abstracts were screened based on the PICOS (Participants, Intervention or Exposure, Comparison, Outcome, Study type) scheme. Articles with full text copies were distributed to the sections of OB/GYN and their research topics. As a result, this review includes 189 articles published from 1994 to 2023. Among these, 148 focus on obstetrics and 41 on gynecology. AI-assisted US applications span fetal biometry, echocardiography, or neurosonography, as well as the identification of adnexal and breast masses, and assessment of the endometrium and pelvic floor. To conclude, the applications for AI-assisted US in OB/GYN are abundant, especially in the subspecialty of obstetrics. However, while most studies focus on common application fields such as fetal biometry, this review outlines emerging and still experimental fields to promote further research.

12.
J Clin Med ; 12(22)2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-38002614

RESUMO

Cesarean section (CS) is the most widely performed and one of the most painful surgeries. This study investigated postoperative pain after CS using patient-related outcomes (PROs) to identify risk factors for severe pain. The secondary outcome was to evaluate the influence of surgery indication (primary CS (PCS) vs. urgent CS (UCS)). This multi-center, prospective cohort study included data submitted to the pain registry "quality improvement in postoperative pain treatment" (QUIPS) between 2010 and 2020. In total, 11,932 patients were evaluated. Median of maximal pain was 7.0 (numeric rating scale (NRS) 0 to 10); 53.9% suffered from severe pain (NRS ≥ 7), this being related to impairment of mood, ambulation, deep breathing and sleep, as well as more vertigo, nausea and tiredness (p < 0.001). Distraction, relaxation, mobilization, having conversations, patient-controlled analgesia (PCA) and pain monitoring were shown to be protective for severe pain (p < 0.001). Maximal pain in PCS and UCS was similar, but UCS obtained more analgesics (p < 0.001), and experienced more impairment of ambulation (p < 0.001) and deep breathing (p < 0.05). Severe pain has a major effect on daily-life activities and recovery after CS, and depends on modifiable factors. More effort is needed to improve the quality of care after CS.

13.
Sensors (Basel) ; 23(19)2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37836987

RESUMO

In this paper, a novel concept of a three-dimensional full metal system including a Dual-Mode Converter (DMC) network integrated with a high-gain Conical Horn Antenna (CHA) is presented. This system is designed for 5G millimeter wave applications requiring monopulse operation at K-band (37.5-39 GHz). The DMC integrates two mode converters. They excite either the TE11cir or the TE01cir modes of the circular waveguide of the CHA. The input of the mode converters is the TE10rec mode of two independent WR-28 standard rectangular waveguide ports. By integrating the DMC with the CHA, the whole system, called a Dual-Mode Conical Horn Antenna (DM-CHA), is formed, radiating the sum (Σ) and difference (Δ) patterns associated to the monopulse operation. To adequately prevent the propagation of higher order modes and mode mutual coupling, this integration procedure is carefully designed and fabricated. To prove the performance of the design, the DMC network was fabricated using subtractive manufacturing by Computer Numerical Control (CNC) technology. The CHA was fabricated using additive manufacturing by Direct Metal Laser Sintering (DLMS) technology. Finally, the simulation and measurement results were exhaustively compared, including return loss, isolation, radiation pattern, and gain of the full DM-CHA structure. It is noteworthy that this system provided up to ±11° per beam in the angular of arrival detection to support the high data rate operation for 5G satellite communications in the millimeter-wave band.

14.
Protein Pept Lett ; 30(9): 719-733, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37691216

RESUMO

BACKGROUND: The immune system is able to recognize substances that originate from inside or outside the body and are potentially harmful. Foreign substances that bind to immune system components exhibit antigenicity and are defined as antigens. The antigens exhibiting immunogenicity can induce innate or adaptive immune responses and give rise to humoral or cell-mediated immunity. The antigens exhibiting mitogenicity can cross-link cell membrane receptors on B and T lymphocytes leading to cell proliferation. All antigens vary greatly in physicochemical features such as biochemical nature, structural complexity, molecular size, foreignness, solubility, and so on. OBJECTIVE: Thus, this review aims to describe the molecular bases of protein-antigenicity and those molecular bases that lead to an immune response, lymphocyte proliferation, or unresponsiveness. CONCLUSION: The epitopes of an antigen are located in surface areas; they are about 880-3,300 Da in size. They are protein, carbohydrate, or lipid in nature. Soluble antigens are smaller than 1 nm and are endocytosed less efficiently than particulate antigens. The more the structural complexity of an antigen increases, the more the antigenicity increases due to the number and variety of epitopes. The smallest immunogens are about 4,000-10,000 Da in size. The more phylogenetically distant immunogens are from the immunogen-recipient, the more immunogenicity increases. Antigens that are immunogens can trigger an innate or adaptive immune response. The innate response is induced by antigens that are pathogen-associated molecular patterns. Exogenous antigens, T Dependent or T Independent, induce humoral immunogenicity. TD protein-antigens require two epitopes, one sequential and one conformational to induce antibodies, whereas, TI non-protein-antigens require only one conformational epitope to induce low-affinity antibodies. Endogenous protein antigens require only one sequential epitope to induce cell-mediated immunogenicity.


Assuntos
Proteínas de Transporte , Linfócitos T , Epitopos , Membrana Celular
15.
Sensors (Basel) ; 23(15)2023 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-37571745

RESUMO

Two types of cost-efficient antennas based on dielectric gradient index dielectric lens have been designed for 5G applications at 28 GHz. The first is a linearly polarized flat lens antenna (LP-FLA) for terrestrial 5G communications. The second is a novel circularly polarized stepped lens antenna (CP-SLA) for 5G satellite services. An efficient design method is presented to optimize and conform the lens topology to the radiation pattern coming from the antenna feeder. The LP-FLA is fed by a traditional linearly polarized pyramidal horn antenna (PHA). The CP-SLA is fed by an open-ended bow-tie waveguide cavity (BCA) antenna. This cavity feeder (BCA), using cross-sections with bow-tie shapes, allows having circular polarization at the desired frequency bandwidth. The two types of presented antennas have been manufactured in order to verify their performance by an easy, low-cost, three-dimensional (3D) printing technique based on stereolithography. The peak realized gain value for the flat (LP-FLA) and stepped (CP-SLA) lens antennas have been increased at 28 GHz to 25.2 and 24.8 dBi, respectively, by disposing the lens structures at the appropriated distance from the feeders. Likewise, using an array of horns (PHA) or open-ended bow-tie waveguide cavity (BCA) antenna feeders, it is possible to obtain a maximum steering angle range of 20° and 35°, for a directivity over 15 dBi and 10 dBi, in the planar and stepped lens antennas, respectively.

16.
N Engl J Med ; 389(8): 687-699, 2023 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-37486775

RESUMO

BACKGROUND: The risk of cardiovascular disease is increased among persons with human immunodeficiency virus (HIV) infection, so data regarding primary prevention strategies in this population are needed. METHODS: In this phase 3 trial, we randomly assigned 7769 participants with HIV infection with a low-to-moderate risk of cardiovascular disease who were receiving antiretroviral therapy to receive daily pitavastatin calcium (at a dose of 4 mg) or placebo. The primary outcome was the occurrence of a major adverse cardiovascular event, which was defined as a composite of cardiovascular death, myocardial infarction, hospitalization for unstable angina, stroke, transient ischemic attack, peripheral arterial ischemia, revascularization, or death from an undetermined cause. RESULTS: The median age of the participants was 50 years (interquartile range, 45 to 55); the median CD4 count was 621 cells per cubic millimeter (interquartile range, 448 to 827), and the HIV RNA value was below quantification in 5250 of 5997 participants (87.5%) with available data. The trial was stopped early for efficacy after a median follow-up of 5.1 years (interquartile range, 4.3 to 5.9). The incidence of a major adverse cardiovascular event was 4.81 per 1000 person-years in the pitavastatin group and 7.32 per 1000 person-years in the placebo group (hazard ratio, 0.65; 95% confidence interval [CI], 0.48 to 0.90; P = 0.002). Muscle-related symptoms occurred in 91 participants (2.3%) in the pitavastatin group and in 53 (1.4%) in the placebo group; diabetes mellitus occurred in 206 participants (5.3%) and in 155 (4.0%), respectively. CONCLUSIONS: Participants with HIV infection who received pitavastatin had a lower risk of a major adverse cardiovascular event than those who received placebo over a median follow-up of 5.1 years. (Funded by the National Institutes of Health and others; REPRIEVE ClinicalTrials.gov number, NCT02344290.).


Assuntos
Doenças Cardiovasculares , Infecções por HIV , Inibidores de Hidroximetilglutaril-CoA Redutases , Humanos , Pessoa de Meia-Idade , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/prevenção & controle , Método Duplo-Cego , Infecções por HIV/complicações , Infecções por HIV/tratamento farmacológico , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/prevenção & controle , Quinolinas/efeitos adversos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico
17.
AIDS ; 37(14): 2149-2159, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37503623

RESUMO

BACKGROUND: Hepatic steatosis, including nonalcoholic fatty liver disease (NAFLD), is common among people with HIV (PWH). We present baseline steatosis prevalence and cardiometabolic characteristics among REPRIEVE substudy participants. METHODS: REPRIEVE is an international, primary cardiovascular disease prevention, randomized, controlled trial of pitavastatin calcium vs. placebo among 7769 PWH ages 40-75 years on antiretroviral therapy (ART) and with low-to-moderate cardiovascular risk. A subset of participants underwent noncontrast computed tomography, with hepatic steatosis defined as mean hepatic attenuation less than 40 HU or liver/spleen ratio less than 1.0, and NAFLD defined as steatosis in the absence of frequent alcohol use or viral hepatitis. RESULTS: Of 687 evaluable persons, median age was 51 years, BMI 27 kg/m 2 , CD4 + T-cell count 607 cells/µl; 17% natal female sex, 36% Black, 24% Hispanic, and 98% HIV-1 RNA less than 400 copies/ml. Hepatic steatosis prevalence was 22% (149/687), and NAFLD 21% (96/466). Steatosis/NAFLD prevalence was higher in men and with older age, non-Black race, and higher BMI and waist circumference. Both were associated with BMI greater than 30 kg/m 2 , metabolic syndrome components, higher atherosclerotic cardiovascular disease (ASCVD) risk score, HOMA-IR, LpPLA-2 and hs-CRP, and lower high-density lipoprotein cholesterol. Of HIV-specific/ART-specific characteristics, only history of an AIDS-defining illness was more common among persons with steatosis/NAFLD. After adjusting for age, sex and race/ethnicity, BMI greater than 30 kg/m 2 , HOMA-IR greater than 2.0, Metabolic syndrome and each of its components were associated with NAFLD prevalence. CONCLUSION: In this cohort with controlled HIV and low-to-moderate cardiovascular risk, hepatic steatosis and NAFLD were common and associated with clinically relevant metabolic and inflammatory disturbances but not current HIV-related or ART-related factors.


Assuntos
Doenças Cardiovasculares , Infecções por HIV , Síndrome Metabólica , Hepatopatia Gordurosa não Alcoólica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/prevenção & controle , Doenças Cardiovasculares/complicações , Infecções por HIV/complicações , Infecções por HIV/tratamento farmacológico , Infecções por HIV/epidemiologia , Síndrome Metabólica/complicações , Síndrome Metabólica/epidemiologia , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/epidemiologia , Prevenção Primária , Adulto , Idoso
18.
Humanidad. med ; 23(1)abr. 2023.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1440200

RESUMO

Se realizó un estudio observacional, descriptivo y transversal en colaboración entre profesionales cubanos y venezolanos involucrados en la dirección del proceso de formación de la carrera Medicina Integral Comunitaria en la Universidad de Ciencias de la Salud Hugo Rafael Chávez, con el propósito de valorar el impacto de la actividad comunitaria en la formación de los estudiantes de Medicina Integral Comunitaria en el enfrentamiento a la COVID-19 en el Estado Falcón, en el período de febrero a septiembre de 2020. El universo lo representa 508 estudiantes de la carrera y la muestra estuvo conformada por 244 que se incorporaron en las actividades comunitaria en el enfrentamiento a la COVID-19. Se utilizó la observación participativa e informes diarios de actividad de pesquisa, la revisión documental, encuesta y técnicas de estadística descriptiva. Se emplearon medidas resúmenes como media, porcentaje que permitieron la búsqueda y procesamiento de la información. Los principales resultados fueron la transformación del personal pedagógico en los diferentes niveles de dirección y la organización del sistema de influencia en los estudiantes, la introducción de un nuevo estilo de trabajo en función de elevar la calidad del proceso docente educativo a partir de la educación a distancia, la integración de los estudiantes a las actividades comunitarias en la contingencia y su impacto en la formación integral de los futuros profesionales de la salud, así como la solución de los problemas de salud de las comunidades del territorio.


An observational, descriptive and cross-sectional study was carried out in collaboration between Cuban and Venezuelan professionals involved in the direction of the training process of the Comprehensive Community Medicine career at the Hugo Rafael Chávez University of Health Sciences, with the purpose of assessing the impact of the community activity in the comprehensive training of Comprehensive Community Medicine students in the confrontation with COVID-19 in Falcón State, from February to September 2020. The universe is represented by 508 students from the Comprehensive Community Medicine career and The sample consisted of 244 students who joined community activities in the fight against COVID-19. Participatory observation and daily reports of research activity, documentary review, survey and descriptive statistical techniques were used using summary measures such as average, percentage, which allowed the search remains and information processing, the main results obtained were the transformation of the pedagogical personnel at the different levels of management and the organization of the system of influence on the students, the introduction of a new style of work in order to raise the quality of the process educational teacher from distance education, the integration of students into community activities in the contingency and its impact on the comprehensive training of future health professionals and the solution of health problems in the communities of the territory.

19.
Biosens Bioelectron ; 226: 115113, 2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-36764127

RESUMO

This work examines the suitability of graphene-based 3D-printed nanocomposite bioelectronics as innovative systems to in situ monitor and evaluate both breast cancer cell adhesion and the chemosensitivity of anti-cancer drugs. With this aim, 3D-printed nanocomposite graphene electrodes (3D-nGEs) -made of a commercially available graphene/polylactic acid filament- have been covalently biofunctionalized with an extracellular matrix protein (i.e., fibronectin) by exploiting the carbon reactivity of 3D-nGEs. The specificity and selectivity of the developed electrochemical system to monitor breast cancer cell adhesion has been tested via electrochemical impedance spectroscopy (EIS). Importantly, the resulting 3D-printed bioelectronic system displayed excellent accuracy for the rapid screening of anti-cancer drugs, which exactly corresponded with the results achieved by the standard optical method, while having the advantage of employing a label-free approach. In light of the current state-of-the-art in the field, this proof-of-concept connects electronics to biological systems within 3D printing technology, providing the bases for the sustainable and cost-effective manufacturing of graphene-based 3D-printed nanocomposite bioelectronics to simulate in vivo microenvironments using in situ and real time electronic output signals.


Assuntos
Antineoplásicos , Técnicas Biossensoriais , Neoplasias da Mama , Grafite , Nanocompostos , Humanos , Feminino , Grafite/química , Adesão Celular , Técnicas Biossensoriais/métodos , Impressão Tridimensional , Microambiente Tumoral
20.
J Clin Med ; 12(2)2023 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-36675605

RESUMO

Women who have had a Cesarean Section (CS) frequently report severe pain and pain-related interference. One reason for insufficient pain treatment might be inconsistent implementation of evidence-based guidelines. We assessed the association between implementing three elements of care recommended by guidelines for postoperative pain management and pain-related patient-reported outcomes (PROs) in women after CS. The analysis relied on an anonymized dataset of women undergoing CS, retrieved from PAIN OUT. PAIN OUT, an international perioperative pain registry, provides clinicians with treatment assessment methodology and tools for patients to assess multi-dimensional pain-related PROs on the first postoperative day. We examined whether the care included [i] regional anesthesia with a neuraxial opioid OR general anesthesia with wound infiltration or a Transvesus Abdominis Plane block; [ii] at least one non-opioid analgesic at the full daily dose; and [iii] pain assessment and recording. Credit for care was given only if all three elements were administered (= "full"); otherwise, it was "incomplete". A "Pain Composite Score-total" (PCStotal), evaluating outcomes of pain intensity, pain-related interference with function, and side-effects, was the primary endpoint in the total cohort (women receiving GA and/or RA) or a sub-group of women with RA only. Data from 5182 women was analyzed. "Full" care was administered to 20% of women in the total cohort and to 21% in the RA sub-group. In both groups, the PCStotal was significantly lower compared to "incomplete" care (p < 0.001); this was a small-to-moderate effect size. Administering all three elements of care was associated with better pain-related outcomes after CS. These should be straightforward and inexpensive for integration into routine care after CS. However, even in this group, a high proportion of women reported poor outcomes, indicating that additional work needs to be carried out to close the evidence-practice gap so that women who have undergone CS can be comfortable when caring for themselves and their newborn.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA