Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Prosthet Dent ; 130(6): 858.e1-858.e6, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37802733

RESUMO

STATEMENT OF PROBLEM: Rigid post-and-core systems have traditionally been used in the restoration of endodontically treated teeth and are regarded by many as the standard treatment. Flexible materials, including nanoceramic resins, are being increasingly implemented as post-and-core systems, but data supporting their use are lacking. PURPOSE: The purpose of this in vitro study was to compare the fatigue resistance of conventional cast metal and nanoceramic 3-dimensionally (3D) printed resin post-and-core systems with teeth without posts. MATERIAL AND METHODS: Thirty freshly extracted human maxillary premolars were endodontically treated and divided into 3 subgroups (n=10) according to the restorative procedure: cast metal post-and-core (CM), nanoceramic 3D printed resin post-and-core (3DR), and without a post (0P). The CM post-and-core group was fabricated conventionally, while the 3DR group was printed using a 3D resin printing material. For the 0P group, the teeth were restored with a composite resin foundation after root canal obturation. Complete coverage 3-mol% monolithic zirconia restorations were cemented on all specimens. The specimens were exposed to simultaneous mastication simulation (1.2 million cycles) and thermocycling (10 000 cycles at 5 ºC to 55 ºC) and analyzed based on the failure of specimens. Data were analyzed using the Kruskal-Wallis survival analysis and the Wilcoxon rank sum test (α=.05). RESULTS: The Kruskal-Wallis test indicated statistically significant differences among the cycles needed to reach failure for each of the 3 groups (P<.001). At 1.2 million cycles, there were no CM failures. The 3DR group failed at a median value of 950 000 cycles, while the 0P group failed at a median value of 222 500 cycles (P<.001). CONCLUSIONS: All the endodontically treated teeth that received CM survived the 1 200 000 simulated mastication cycles. Both 3DR and 0P specimens fractured at the crown cervical third during mastication simulation.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Humanos , Mastigação , Dente não Vital/terapia , Coroas , Resinas Compostas/uso terapêutico , Análise do Estresse Dentário , Falha de Restauração Dentária
2.
J Prosthet Dent ; 2022 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-36163200

RESUMO

STATEMENT OF PROBLEM: Few studies have investigated the differences among various post-and-core systems under mastication simulation. Comparing these systems while simulating the clinical environment should provide a more accurate assessment of their performance. PURPOSE: The purpose of this in vitro study was to evaluate the fatigue resistance of conventional cast metal and prefabricated fiber post systems with computer-aided design and computer-aided manufacture (CAD-CAM) prefabricated nonmetal post-and-core systems. MATERIAL AND METHODS: Forty freshly extracted human maxillary premolars were endodontically treated and divided into 4 subgroups (n=10) according to the material: cast metal, zirconia, fiber-reinforced composite resin, prefabricated fiber post. The post-and-core materials were manufactured either conventionally or milled with CAD-CAM technology. All specimens were exposed to simultaneous mastication simulation (1.2 million cycles) and thermocycling (10 000 cycles at 5 °C to 55 °C) and analyzed based on failure of specimens. Data were analyzed by using the Kaplan-Meier survival analysis and Cox-regression (α=.05). RESULTS: Both cast metal and zirconia post-and-core groups had similar fatigue resistance (P>.05) but significantly higher fatigue resistance than the fiber-reinforced groups (P<.05). Fiber-reinforced composite resin and prefabricated fiber post did not survive the mastication simulation, fracturing between 504 000 and 752 000 cycles, with fractures occurring in the cervical portion of the tooth. CONCLUSIONS: Cast metal and zirconia post-and-core systems had improved physical properties with high resistance to fatigue when compared with fiber-reinforced post-and-core systems.

3.
J Esthet Restor Dent ; 34(4): 633-640, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35312154

RESUMO

OBJECTIVE: To compare four different types of monolithic zirconia crowns in terms of survival rate and fracture resistance after thermocycling and/or thermo-mechanical loading in a chewing simulator. METHODS: Partially stabilized zirconia (PSZ) crowns with fiber-reinforced resin die assemblies (n = 80) were fabricated using: multi-yttria-layered 5Y-PSZ/3Y-PSZ, multi-yttria-layered 5Y-PSZ/4Y-PSZ, monolithic 4Y-PSZ, and monolithic 3Y-PSZ as control (n = 20). Half of the samples in each group were subjected to thermo-mechanical loading under 110 N, 1.4 Hz, 1.2 million cycles with simultaneous thermocycling (10,000 cycles, 5-55°C). The other half were subjected to thermocycling alone. The samples were loaded to failure to measure their fracture resistance. The data were analyzed using by two-way ANOVA and Tukey's HSD post-hoc test (α = 0.05). RESULTS: All specimens survived the aging protocols. The yttria content significantly affected the fracture resistance of the crowns (p < 0.0001). The mean fracture resistance, from highest to lowest: 3Y-PSZ, 4Y-PSZ, followed by the two multi-yttria-layered systems. The mean difference between the two multi-yttria-layered systems were not statistically significant (p = 0.98). The mechanical loading protocol did not affect the mean fracture resistance within each group (p = 0.18). CONCLUSIONS: Within each group, there was no difference in fracture resistance after thermocycling alone and thermo-mechanical loading. However, increasing the yttria concentration at the occlusal third of the crown decreased its fracture resistance. CLINICAL SIGNIFICANCE: The term "monolithic zirconia" alone without specifying the actual yttria content is misleading. This term represents different materials with different mechanical properties. The yttria content has an inverse relationship with the fracture resistance of zirconia crowns. The fracture resistance of multi-layer zirconia crowns is determined by the amount of the weaker zirconia phase at the occlusal part of the restoration rather than enforced by the stronger zirconia at the cervical part of the crown.


Assuntos
Mastigação , Zircônio , Coroas , Porcelana Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Ítrio
4.
Int J Periodontics Restorative Dent ; 40(3): e111-e118, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32233191

RESUMO

Agenesis of the permanent dentition is rare. This report describes a 20-year-old woman with 19 deciduous teeth, a single permanent mandibular premolar, and other physical traits associated with ectodermal dysplasia. The patient demonstrated esthetic parameters associated with maxillomandibular alveolar insufficiency, and her chief complaints were directed toward esthetics and the potential impact of restorative choices on function. Three typical options for restoration include overdentures, removable partial dentures, or implant-supported prostheses replacing her natural dentition. This report illustrates a fully integrated digital approach to treatment planning, the fabrication of a computer-aided design/computer-assisted manufacture surgical guide and provisional restoration, guided implant placement, and definitive restoration using monolithic zirconia implant-supported fixed dental prostheses. The lifelong management of this rehabilitation is an acknowledged challenge.


Assuntos
Anodontia , Prótese Parcial Removível , Adulto , Prótese Dentária Fixada por Implante , Dentição Permanente , Revestimento de Dentadura , Feminino , Humanos , Adulto Jovem
5.
Med Dosim ; 45(2): 134-139, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31521451

RESUMO

Radiotherapy to an intact breast was previously determined to have a positive correlation between breast separation measurement and hot spot dose. As breast separation measurement increased, hot spot dose increased. The purpose of this retrospective study was to determine if this correlation persisted despite current techniques including field-in-field (FiF) blocking and mixed photon energies. Radiation treatment plans on unilateral intact breasts from 90 female, early stage breast cancer patients treated with lumpectomy were analyzed. Plans were created using 3-dimensional conformal radiation therapy (3D-CRT) nondivergent opposing tangent beams, FiF technique, and 6 MV with or without higher energy photons. Data collected included breast separation measurement, hot spot point dose and location, number of beams, photon energy, clinical target volume (CTV) coverage and breast volume coverage. Correlations between breast separation measurement and each of these values were determined. The positive correlation between breast separation measurement and hot spot dose persisted despite incorporating FiF and mixed photon energies. Correlations were also found between breast separation and the number of beams as well as breast separation and photon energy. Larger breast separations tended to be treated with additional beams of higher photon energy. There were no correlations found between breast separation and CTV or breast volume coverage. The data in this study suggested the medical dosimetrist should expect hot spots above prescription dose of 106%, 107%, and 108% for small, medium and large breast separation sizes respectively. Additionally, adding a high energy photon bean may be indicated with medium and large breast separations.


Assuntos
Neoplasias da Mama/radioterapia , Radioterapia Conformacional , Neoplasias da Mama/cirurgia , Feminino , Humanos , Mastectomia Segmentar , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
6.
Med Dosim ; 45(1): 52-59, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31221447

RESUMO

The purpose of this study was to investigate the dosimetric impact of weight loss in head and neck (H&N) patients and examine the effectiveness of adaptive planning. Data was collected from 22 H&N cancer patients who experienced weight loss during their course of radiotherapy. The robustness of Intensity Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) treatment plans were compared including the potential need for replanning. The dosimetric impact of weight loss was evaluated by calculating a verification plan for each patient on an assessment CT scan taken during the course of treatment. Using a regression analysis, significance was tested for the dosimetric change in target volumes and 10 specific organs at risk (OAR) using an anatomical separation difference in the H&N at corresponding levels. For both the IMRT and VMAT plans, a significant correlation was found for the dose to 5% of the high risk Planning Target Volume (PTV) (D5), dose to 95% of the intermediate risk PTV and Clinical Target Volume (CTV) (D95), and the percentage of the pharynx receiving 65 Gy. An independent t-test was also performed for each metric in the VMAT and IMRT plans showing the dose to 95% of the intermediate risk PTV as significant. No quantitative method for finding the threshold of anatomical separation difference requiring a replan was established. Based on the increase in dose to organs at risk and increased target coverage due to separation loss, it was concluded that adaptive radiotherapy may not always be necessary when alignment of bony anatomy and remaining soft tissue is within tolerance. Physician judgment and preference is needed in such situations.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Redução de Peso , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/efeitos adversos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
7.
Med Dosim ; 45(2): 121-127, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31570239

RESUMO

Decreasing radiotoxicity to the heart, lungs, and contralateral breast has proven to lower the risk of secondary malignancy and improve overall outcomes when treating chest wall (CW) and regional lymph nodes in postmastectomy breast cancer patients. In this retrospective study, 11 postmastectomy patients were selected and planned with a novel hybrid treatment method and a traditional volumetric arc therapy (VMAT) approach for comparison. This hybrid technique was able to optimize tangential beams to minimize heart dose and the VMAT contribution to improve dose conformity around the planning target volume (PTV). Overall, this hybrid technique produced more homogenous target dose coverage and demonstrated a decrease of integral dose to organs at risk (OAR), while the VMAT technique demonstrated a higher affinity for maintaining dose conformity. Further observation of dose distributions also revealed that the hybrid plans were more effective in sparing low-dose spread to healthy tissue in both right- and left-sided cases. This observation was made evident by the reduction in heart V5 and Dmean, decreases in all parameters regarding the contralateral lung, as well as all values other than the V20 of the ipsilateral lung. This unique hybrid planning technique could present an alternative to standard intensity-modulated radiation therapy (IMRT) planning when treating postmastectomy CW and regional lymph nodes, as it has shown the capacity to decrease cardiac, lung, and contralateral breast toxicity while maintaining quality PTV coverage.


Assuntos
Neoplasias da Mama/radioterapia , Linfonodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Parede Torácica , Adulto , Idoso , Neoplasias da Mama/cirurgia , Feminino , Humanos , Mastectomia , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Estudos Retrospectivos
8.
J Esthet Restor Dent ; 28(6): 382-396, 2016 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-27264939

RESUMO

PROBLEM: Intraoral occlusal adjustment of ceramic restorations can create a significant increase in surface roughness that can produce wear of the opposing dentition. PURPOSE: To compare the surface roughness of glazed and polished monolithic ceramics with the surface roughness produced by different intraoral polishing systems on adjusted monolithic ceramics. MATERIALS AND METHODS: Milled ceramic discs (10 mm diameter × 2 mm thickness) were manufactured and distributed according to the following groups (n = 10): BruxZir (glazed and polished), Zenostar (glazed and polished), IPS Empress CAD, and IPS e.max CAD. Surface roughness, expressed as arithmetic average height (Ra ), was measured using atomic force microscope and profilometer before and after adjustment and polishing with the following intraoral polishing systems: BruxZir and Dialite ZR (for BruxZir), Zenostar and Dialite ZR (for Zenostar), and OptraFine and Dialite LD for IPS Empress CAD and IPS e.max CAD. Mean and standard error for each material and polishing system were calculated. T-test, one-way ANOVA, and Bonferroni post hoc tests were used to analyze data. RESULTS: BruxZir zirconia presented smoother surfaces with Dialite ZR system compared to BruxZir system, Zenostar zirconia shown smoother surfaces with Zenostar system compared to Dialite ZR system and IPS Empress CAD and IPS e.max CAD presented smoother surfaces with OptraFine system in comparison to Dialite LD system. CONCLUSION: All materials presented smoother surfaces at baseline than after adjustment and polishing. CLINICAL SIGNIFICANCE: This paper reveals the results of an in vitro study that provides information to clinicians regarding which intraoral polishing system will produce a smoother surface after the adjustment and polishing of IPS Empress CAD, IPS e.max CAD, BruxZir and Zenostar ceramic materials. (J Esthet Restor Dent 28:382-396, 2016).


Assuntos
Polimento Dentário , Porcelana Dentária , Ajuste Oclusal , Cerâmica , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície
9.
J Esthet Restor Dent ; 28(3): 144-56, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27154432

RESUMO

OBJECTIVE: The use of overdentures for treatment of oligodontia in adolescent patients using conventional techniques has described limitations. The aim of the case report is to demonstrate the use of CAD (Computer Aided Design) CAM (Computer Aided Manufacture) technology to produce an esthetic monolithic polymethylmethacrylate prosthesis that is retentive and stable on insertion. CLINICAL CONSIDERATIONS: Adolescent oligodontia patients are typically not suitable candidates for dental implant therapy. Overdentures provide interim or definitive restorative advantages. Given the important esthetic, psychological, and social functions of the prosthesis, an important therapeutic goal for the overdenture prosthesis is esthetics. A CAD-CAM approach to overdenture manufacture can provide a highly esthetic, strong, and retentive prosthesis. CONCLUSIONS: CAD-CAM manufacture of monolithic acrylic overdentures offer several advantages that include (1) improved planning and clinical communication, (2) high fidelity manufacture, (3) improved flexural strength, impact strength, and porosity, (4) improved prosthesis integrity and durability (due to the monolithic design), (5) CNC control of occlusal contacts, (6) high esthetic potential due to quality of bulk material and iterative design, and (7) archival nature of the digital prosthesis. CAD-CAM manufacture of monolithic overdentures is a viable approach to completing high value esthetic management of the adolescent oligodontia patient. CLINICAL SIGNIFICANCE: This case report identifies a new way to utilize CAD CAM technology to produce an improved overdenture for the oligodontia patient. It will be of interest to many and underscores the fundamental principles of smile design transfer to the digital environment. (J Esthet Restor Dent, 2016).


Assuntos
Revestimento de Dentadura , Adolescente , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Estética Dentária , Humanos
12.
Compend Contin Educ Dent ; 31(9): 716-20, 722, 724-5, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21197940

RESUMO

As dentistry continues to evolve, new technologies and materials are continually being offered to the dental profession. Throughout the years restorative trends and techniques have come and gone. Some material developments have transformed the face of esthetic dentistry, while other initial concepts have already phased out and disappeared. Today, all-ceramic restorations continue to grow in the area of restorative dentistry, from pressed-ceramic techniques and materials to the growing use of zirconia, and new materials that can be created from CAD/CAM technology. This article will explore new uses for the all-ceramic material known as lithium disilicate, and the use of a digital format to design and process this material in new and exciting ways. An overview of the material as well as unique clinical procedures will be presented.


Assuntos
Desenho Assistido por Computador , Porcelana Dentária , Planejamento de Prótese Dentária , Restauração Dentária Permanente/métodos , Compostos de Lítio , Adulto , Coroas , Estética Dentária , Feminino , Humanos , Restaurações Intracoronárias , Silicatos
15.
Pract Proced Aesthet Dent ; 14(6): 473-8; quiz 479, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12242858

RESUMO

Accurate communication among the patient, clinician, and laboratory technician is critical to the development of a functional, aesthetic restoration. The use of pressed ceramic restorations has provided a durable, consistent alternative for full-coverage crowns, veneers, onlays, and short-span fixed partial dentures. This article discusses the importance of proper ingot selection in the fabrication of aesthetic restorations and in the realization of patients' expectations for smile design. Ceramic ingots are available in a variety of colors and opacities that provide the clinician and laboratory technician with the latitude to select an ingot that will ultimately ensure patient satisfaction.


Assuntos
Cerâmica/química , Restauração Dentária Permanente/métodos , Estética Dentária , Silicatos de Alumínio/química , Cor , Esmalte Dentário/anatomia & histologia , Porcelana Dentária/química , Planejamento de Prótese Dentária , Técnicos em Prótese Dentária , Dentina/anatomia & histologia , Relações Dentista-Paciente , Humanos , Relações Interprofissionais , Laboratórios Odontológicos , Óptica e Fotônica , Satisfação do Paciente , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA