RESUMO
BACKGROUND: Patients with an indication for oral anticoagulation who undergo percutaneous coronary intervention require a combination of oral anticoagulation and antiplatelet therapy. The use of a coronary stent with a thromboresistant and pro-healing coating may allow an abbreviated duration of dual antiplatelet therapy (DAPT) without an increase in the risk of thromboembolic events. METHODS: Patients with an indication for oral anticoagulation undergoing percutaneous coronary intervention were randomized to treatment with the COBRA polyzene F (PzF) stent followed by 14 days of DAPT or a Food and Drug Administration-approved new-generation drug-eluting stent followed by 3 or 6 months of DAPT. The bleeding coprimary end point was Bleeding Academic Research Consortium type ≥2 beyond 14 days (or after hospital discharge) until 6 months. The thromboembolic coprimary end point was the composite of all-cause death, myocardial infarction, definite or probable stent thrombosis, or ischemic stroke at 6 months. The trial hypothesis was that the COBRA PzF stent strategy would be superior with respect to bleeding events and noninferior with respect to thromboembolic events. RESULTS: A total of 996 patients underwent randomization. The bleeding end point occurred in 37 of 475 patients (7.8%) in the COBRA PzF group and 47 of 482 patients (9.8%) in the control group (difference, -2.0 [95% CI, -5.6 to 1.6]; P=0.14). The thromboembolic end point occurred in 37 of 492 patients (7.5%) in the COBRA PzF group and 24 of 490 patients (4.9%) in the control group (difference, 2.6%; prespecified noninferiority margin 5%, upper limit of 1-sided 95% CI of the difference, 5.2%; Pnoninferiority=0.07). CONCLUSIONS: In patients with an indication for oral anticoagulation undergoing percutaneous coronary intervention, treatment with the COBRA PzF stent plus 14 days of DAPT was not superior with respect to bleeding events and was not noninferior with respect to thromboembolic events at 6 months compared with treatment with standard Food and Drug Administration-approved drug-eluting stent plus 3 to 6 months of DAPT. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02594501.
Assuntos
Anticoagulantes , Doença da Artéria Coronariana , Esquema de Medicação , Stents Farmacológicos , Hemorragia , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária , Desenho de Prótese , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Feminino , Idoso , Fatores de Tempo , Pessoa de Meia-Idade , Resultado do Tratamento , Hemorragia/induzido quimicamente , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/efeitos adversos , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Fatores de Risco , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Administração Oral , Tromboembolia/prevenção & controle , Tromboembolia/etiologia , Quimioterapia Combinada , Terapia Antiplaquetária Dupla/efeitos adversos , Trombose Coronária/etiologia , Trombose Coronária/prevenção & controle , Medição de Risco , Estudos Prospectivos , StentsRESUMO
BACKGROUND: There is a little evidence regarding long-term safety and efficacy for atrial shunt devices in heart failure (HF). METHODS: The REDUCE LAP-HF I (n = 44) and II (n = 621) trials (RCT-I and -II) were multicenter, randomized, sham-controlled trials of patients with HF and ejection fraction >40%. Outcome data were analyzed from RCT-I, a mechanistic trial with 5-year follow-up, and RCT-II, a pivotal trial identifying a responder group (n = 313) defined by exercise PVR <1.74 WU and no cardiac rhythm management device with 3-year follow-up. RESULTS: At 5 years in RCT I, there were no differences in cardiovascular (CV) mortality, HF events, embolic stroke, or new-onset atrial fibrillation between groups. After 3 years in RCT II, there was no difference in the primary outcome (hierarchical composite of CV mortality, stroke, HF events, and KCCQ) between shunt and sham in the overall trial. Compared to sham, those with responder characteristics in RCT-II had a better outcome with shunt (win ratio 1.6 [95% CI 1.2-2.2], P = .006; 44% reduction in HF events [shunt 9 vs. control 16 per 100 patient-years], P = .005; and greater improvement in KCCQ overall summary score [+17.9 ± 20.0 vs. +7.6 ± 20.4], P < .001), while nonresponders had significantly more HF events. Shunt treatment at 3 years was associated with a higher rate of ischemic stroke (3.2% vs. 0%, 95% CI 2%-6.1%, P = .032) and lower incidence of worsening kidney dysfunction (10.7% vs. 19.3%, P = .041). CONCLUSIONS: With up to 5 years of follow up, adverse events were low in patients receiving atrial shunts. In the responder group, atrial shunt treatment was associated with a significantly lower HF event rate and improved KCCQ compared to sham through 3 years of follow-up. GOV REGISTRATION: NCT02600234, NCT03088033.
RESUMO
BACKGROUND: The REDUCE LAP-HF II (Reduce Elevated Left Atrial Pressure in Patients With Heart Failure II) trial found that, compared with a sham procedure, the Corvia Atrial Shunt did not improve outcomes in heart failure with preserved or mildly reduced ejection fraction. However, after 12-month follow-up, "responders" (peak-exercise pulmonary vascular resistance <1.74 WU and absence of a cardiac rhythm management device) were identified. OBJECTIVES: This study sought to determine: 1) the overall efficacy and safety of the atrial shunt vs sham control after 2 years of follow-up; and 2) whether the benefits of atrial shunting are sustained in responders during longer-term follow-up or are offset by adverse effects of the shunt. METHODS: The study analyzed 2-year outcomes in the overall REDUCE LAP-HF II trial, as well as in responder and nonresponder subgroups. The primary endpoint was a hierarchical composite of cardiovascular death or nonfatal ischemic/embolic stroke, total heart failure events, and change in health status. RESULTS: In 621 randomized patients, there was no difference between the shunt (n = 309) and sham (n = 312) groups in the primary endpoint (win ratio: 1.01 [95% CI: 0.82-1.24]) or its individual components at 2 years. Shunt patency at 24 months was 98% in shunt-treated patients. Cardiovascular mortality and nonfatal ischemic stroke were not different between the groups; however, major adverse cardiac events were more common in those patients assigned to the shunt compared with sham (6.9% vs 2.7%; P = 0.018). More patients randomized to the shunt had an increase in right ventricular volume of ≥30% compared with the sham control (39% vs 28%, respectively; P < 0.001), but right ventricular dysfunction was uncommon and not different between the treatment groups. In responders (n = 313), the shunt was superior to sham (win ratio: 1.36 [95% CI: 1.02-1.83]; P = 0.037, with 51% fewer HF events [incidence rate ratio: 0.49 [95% CI: 0.25-0.95]; P = 0.034]). In nonresponders (n = 265), atrial shunting was inferior to sham (win ratio: 0.73 [95% CI: 0.54-0.98]). CONCLUSIONS: At 2 years of follow-up in REDUCE LAP-HF II, there was no difference in efficacy between the atrial shunt and sham groups in the overall trial group. The potential clinical benefit identified in the responder group after 1 and 2 years of follow-up is currently being evaluated in the RESPONDER-HF (Re-Evaluation of the Corvia Atrial Shunt Device in a Precision Medicine Trial to Determine Efficacy in Mildly Reduced or Preserved Ejection Fraction Heart Failure) trial. (Reduce Elevated Left Atrial Pressure in Patients With Heart Failure II [REDUCE LAP-HF II]; NCT03088033).
Assuntos
Átrios do Coração , Insuficiência Cardíaca , Volume Sistólico , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/terapia , Feminino , Masculino , Volume Sistólico/fisiologia , Idoso , Pessoa de Meia-Idade , Átrios do Coração/fisiopatologia , Resultado do Tratamento , Seguimentos , Pressão Atrial/fisiologiaRESUMO
Drug-coated balloons (DCBs) are specialized coronary devices comprised of a semicompliant balloon catheter with an engineered coating that allows the delivery of antiproliferative agents locally to the vessel wall during percutaneous coronary intervention. Although DCBs were initially developed more than a decade ago, their potential in coronary interventions has recently sparked renewed interest, especially in the United States. Originally designed to overcome the limitations of conventional balloon angioplasty and stenting, they aim to match or even improve upon the outcomes of drug-eluting stents without leaving a permanent implant. Presently, in-stent restenosis is the condition with the most robust evidence supporting the use of DCBs. DCBs provide improved long-term vessel patency compared with conventional balloon angioplasty and may be comparable to drug-eluting stents without the need for an additional stent layer, supporting their use as a first-line therapy for in-stent restenosis. Beyond the treatment of in-stent restenosis, DCBs provide an additional tool for de novo lesions for a strategy that avoids a permanent metal scaffold, which may be especially useful for the management of technically challenging anatomies such as small vessels and bifurcations. DCBs might also be advantageous for patients with high bleeding risk due to the decreased necessity for extended antiplatelet therapy, and in patients with diabetes and patients with diffuse disease to minimize long-stented segments. Further studies are crucial to confirm these broader applications for DCBs and to further validate safety and efficacy.
Assuntos
Angioplastia Coronária com Balão , Cateteres Cardíacos , Fármacos Cardiovasculares , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana , Reestenose Coronária , Humanos , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/efeitos adversos , Resultado do Tratamento , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Desenho de Equipamento , Fatores de Risco , Grau de Desobstrução Vascular , Stents FarmacológicosRESUMO
The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..
Assuntos
Consenso , Hemorragia , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Hemorragia/etiologia , Medição de Risco , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgiaRESUMO
Importance: Although the results of A Study to Evaluate the Corvia Medical Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure (REDUCE LAP-HF II) trial were neutral overall, atrial shunt therapy demonstrated potential efficacy in responders (no latent pulmonary vascular disease and no cardiac rhythm management device). Post hoc analyses were conducted to evaluate the effect of shunt vs sham stratified by responder status. Objective: To evaluate the effect of atrial shunt vs sham control on cardiac structure/function in the overall study and stratified by responder status. Design, Setting, and Participants: This was a sham-controlled randomized clinical trial of an atrial shunt device in heart failure with preserved ejection fraction (HFpEF)/HF with mildly reduced EF (HFmrEF). Trial participants with evaluable echocardiography scans were recruited from 89 international medical centers. Data were analyzed from April 2023 to January 2024. Interventions: Atrial shunt device or sham control. Main Outcome Measures: Changes in echocardiographic measures from baseline to 1, 6, 12, and 24 months after index procedure. Results: The modified intention-to-treat analysis of the REDUCE LAP-HF II trial included 621 randomized patients (median [IQR] age, 72.0 [66.0-77.0] years; 382 female [61.5%]; shunt arm, 309 [49.8%]; sham control arm, 312 [50.2%]). Through 24 months, 212 of 217 patients (98%) in the shunt arm with evaluable echocardiograms had patent shunts. In the overall trial population, the shunt reduced left ventricular (LV) end-diastolic volume (mean difference, -5.65 mL; P <.001), left atrial (LA) minimal volume (mean difference, -2.8 mL; P =.01), and improved LV systolic tissue Doppler velocity (mean difference, 0.69 cm/s; P <.001) and LA emptying fraction (mean difference, 1.88 percentage units; P =.02) compared with sham. Shunt treatment also increased right ventricular (RV; mean difference, 9.58 mL; P <.001) and right atrial (RA; mean difference, 9.71 mL; P <.001) volumes but had no effect on RV systolic function, pulmonary artery pressure, or RA pressure compared with sham. In the shunt arm, responders had smaller increases in RV end-diastolic volume (mean difference, 5.71 mL vs 15.18 mL; interaction P =.01), RV end-systolic volume (mean difference, 1.58 mL vs 7.89 mL; interaction P =.002), and RV/LV ratio (mean difference, 0.07 vs 0.20; interaction P <.001) and larger increases in transmitral A wave velocity (mean difference, 5.08 cm/s vs -1.97 cm/s; interaction P =.02) compared with nonresponders randomized to the shunt, suggesting greater ability to accommodate shunted blood through the pulmonary circulation enabling LA unloading. Conclusions and Relevance: In this post hoc analysis of the REDUCE LAP-HF II trial, over 2 years of follow-up, atrial shunting led to reverse remodeling of left-sided chambers and increases in volume of right-sided chambers consistent with the shunt flow but no change in RV systolic function compared with sham. Changes in cardiac structure/function were more favorable in responders compared with nonresponders treated with the shunt, supporting the previously identified responder group hypothesis and mechanism, although further evaluation with longer follow-up is needed. Trial Registration: ClinicalTrials.gov Identifier: NCT03088033.
Assuntos
Insuficiência Cardíaca , Volume Sistólico , Humanos , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Masculino , Volume Sistólico/fisiologia , Idoso , Pessoa de Meia-Idade , Ecocardiografia , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Resultado do TratamentoRESUMO
AIMS: Obesity is causally related to the development of heart failure with preserved ejection fraction (HFpEF) but complicates the diagnosis and treatment of this disorder. We aimed to determine the relationship between severity of obesity and clinical, echocardiographic and haemodynamic parameters in a large cohort of patients with documented HFpEF. METHODS AND RESULTS: The REDUCE LAP-HF II trial randomized 626 patients with ejection fraction ≥40% and exercise pulmonary capillary wedge pressure (PCWP) ≥25 mmHg to atrial shunt or sham procedure. We tested for associations between body mass index (BMI), clinical characteristics, cardiac structural and functional abnormalities, physical limitations, quality of life and outcomes with atrial shunt therapy. Overall, 60.9% of patients had BMI ≥30 kg/m2 . As the severity of obesity increased, symptoms (Kansas City Cardiomyopathy Questionnaire score) and 6-min walk distance worsened. More severe obesity was associated with lower natriuretic peptide levels despite more cardiac remodelling, higher cardiac filling pressures, and higher cardiac output. Lower cut points for E/e' were needed to identify elevated PCWP in more obese patients. Strain measurements in all four chambers were maintained as BMI increased. Pulmonary vascular resistance at rest and exercise decreased with higher BMI. Obesity was associated with more first and recurrent heart failure events. However, there was no significant interaction between obesity and treatment effects of the atrial shunt. CONCLUSIONS: Increasing severity of obesity was associated with greater cardiac remodelling, higher right and left ventricular filling pressures, higher cardiac output and increased subsequent heart failure events. Despite significant obesity, many HFpEF patients have preserved right heart and pulmonary vascular function and thus, may be appropriate candidates for atrial shunt therapy.
Assuntos
Flavinas , Insuficiência Cardíaca , Luciferases , Humanos , Volume Sistólico , Cateterismo Cardíaco , Remodelação Ventricular , Qualidade de Vida , Átrios do Coração , Obesidade/complicações , Função Ventricular EsquerdaRESUMO
The Shock Academic Research Consortium is a multi-stakeholder group, including representatives from the US Food and Drug Administration and other government agencies, industry, and payers, convened to develop pragmatic consensus definitions useful for the evaluation of clinical trials enrolling patients with cardiogenic shock, including trials evaluating mechanical circulatory support devices. Several in-person and virtual meetings were convened between 2020 and 2022 to discuss the need for developing the standardized definitions required for evaluation of mechanical circulatory support devices in clinical trials for cardiogenic shock patients. The expert panel identified key concepts and topics by performing literature reviews, including previous clinical trials, while recognizing current challenges and the need to advance evidence-based practice and statistical analysis to support future clinical trials. For each category, a lead (primary) author was assigned to perform a literature search and draft a proposed definition, which was presented to the subgroup. These definitions were further modified after feedback from the expert panel meetings until a consensus was reached. This manuscript summarizes the expert panel recommendations focused on outcome definitions, including efficacy and safety.
Assuntos
Implante de Prótese de Valva Cardíaca , Coração Auxiliar , Humanos , Choque Cardiogênico/terapia , Choque Cardiogênico/cirurgia , Projetos de PesquisaRESUMO
BACKGROUND: Atrial fibrillation (AF) is a common comorbidity in patients with heart failure with preserved ejection fraction (HFpEF) and in heart failure with mildly reduced ejection fraction (HFmrEF). OBJECTIVES: This study sought to describe AF burden and its clinical impact among individuals with HFpEF and HFmrEF who participated in a randomized clinical trial of atrial shunt therapy (REDUCE LAP-HF II [A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure]) and to evaluate the effect of atrial shunt therapy on AF burden. METHODS: Study investigators characterized AF burden among patients in the REDUCE LAP-HF II trial by using ambulatory cardiac patch monitoring at baseline (median patch wear time, 6 days) and over a 12-month follow-up (median patch wear time, 125 days). The investigators determined the association of baseline AF burden with long-term clinical events and examined the effect of atrial shunt therapy on AF burden over time. RESULTS: Among 367 patients with cardiac monitoring data at baseline and follow-up, 194 (53%) had a history of AF or atrial flutter (AFL), and median baseline AF burden was 0.012% (IQR: 0%-1.3%). After multivariable adjustment, baseline AF burden ≥0.012% was significantly associated with heart failure (HF) events (HR: 2.00; 95% CI: 1.17-3.44; P = 0.01) both with and without a history of AF or AFL (P for interaction = 0.68). Adjustment for left atrial reservoir strain attenuated the baseline AF burden-HF event association (HR: 1.71; 95% CI: 0.93-3.14; P = 0.08). Of the 367 patients, 141 (38%) had patch-detected AF during follow-up without a history of AF or AFL. Atrial shunt therapy did not change AF incidence or burden during follow-up. CONCLUSIONS: In HFpEF and HFmrEF, nearly 40% of patients have subclinical AF by 1 year. Baseline AF burden, even at low levels, is associated with HF events. Atrial shunt therapy does not affect AF incidence or burden. (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure [REDUCE LAP-HF II]; NCT03088033).
Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/epidemiologia , Volume Sistólico , Átrios do Coração , Implantação de Prótese , PrognósticoAssuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Inibidores de Hidroximetilglutaril-CoA Redutases , Intervenção Coronária Percutânea , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Síndrome Coronariana Aguda/tratamento farmacológico , Doença da Artéria Coronariana/terapia , Resultado do TratamentoRESUMO
BACKGROUND: Many patients with heart failure and preserved ejection fraction have no overt volume overload and normal resting left atrial (LA) pressure. OBJECTIVES: This study sought to characterize patients with normal resting LA pressure (pulmonary capillary wedge pressure [PCWP] <15 mm Hg) but exercise-induced left atrial hypertension (EILAH). METHODS: The REDUCE LAP-HF II (A Study to Evaluate the Corvia Medical, Inc. IASD System II to Reduce Elevated Left Atrial Pressure in Patients With Heart Failure) trial randomized 626 patients with ejection fraction ≥40% and exercise PCWP ≥25 mm Hg to atrial shunt or sham procedure. The primary trial outcome, a hierarchical composite of death, heart failure hospitalization, intensification of diuretics, and change in health status was compared between patients with EILAH and those with heart failure and resting left atrial hypertension (RELAH). RESULTS: Patients with EILAH (29%) had similar symptom severity, but lower natriuretic peptide levels, higher 6-minute walk distance, less atrial fibrillation, lower left ventricular mass, smaller LA volumes, lower E/e', and better LA strain. PCWP was lower at rest, but had a larger increase with exercise in EILAH. Neither group as a whole had a significant effect from shunt therapy vs sham. Patients with EILAH were more likely to have characteristics associated with atrial shunt responsiveness (peak exercise pulmonary vascular resistance <1.74 WU) and no pacemaker (63% vs 46%; P < 0.001). The win ratio for the primary outcome was 1.56 (P = 0.08) in patients with EILAH and 1.51 (P = 0.04) in those with RELAH when responder characteristics were present. CONCLUSIONS: Patients with EILAH had similar symptom severity but less advanced myocardial and pulmonary vascular disease. This important subgroup may be difficult to diagnose without invasive exercise hemodynamics, but it has characteristics associated with favorable response to atrial shunt therapy. (A Study to Evaluate the Corvia Medical, Inc. IASD System II to Reduce Elevated Left Atrial Pressure in Patients With Heart Failure [REDUCE LAP-HF TRIAL II]; NCT03088033).
Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Hipertensão , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Cateterismo Cardíaco , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico , Volume Sistólico/fisiologia , Função Ventricular EsquerdaRESUMO
OBJECTIVE: The Cardiovascular Outcomes in Renal Atherosclerotic Lesions (CORAL) trial, a multicenter randomized controlled trial with 947 patients, concluded that there was no benefit of renal artery stenting (RAS) over medical therapy. However, patients with chronic kidney disease (CKD) were not analyzed separately in the CORAL trial. CKD is a risk factor for cardiovascular and renal morbidity. We hypothesized that improved renal function after RAS would be associated with increased long-term survival and a lower risk of cardiovascular and renal events in patients with CKD. METHODS: This post hoc analysis of the CORAL trial included 842 patients with CKD stages 2 to 4 at baseline who were randomized to optimal medical therapy alone (OMT; n = 432) or RAS plus OMT (RAS + OMT; n = 410). Patients were categorized as responders or nonresponders based on the change in the estimated glomerular filtration rate (eGFR) from baseline to last follow-up (median, 3.6 years; interquartile range, 2.6-4.6 years). Responders were defined by a 20% or greater increase in eGFR from baseline; all others were designated as nonresponders. Event-free survival was defined as freedom from death and multiple cardiovascular and renal complications. Event-free survival was analyzed using the Kaplan-Meier method and log-rank test. Multivariable Cox proportional hazards regression analysis was used to identify independent predictors of event-free survival. RESULTS: The RAS + OMT group had a higher proportion of patients with improved renal function (≥20% increase in eGFR over baseline), compared with the OMT group (25.6% vs 17.1%; P = .003). However, event-free survival was no different for the two cohorts (P = .18 by the log-rank test). Multivariable Cox proportional hazards regression analysis identified four variables that independently correlated with event-free survival for the stented cohort. Higher preoperative eGFR (hazard ratio, 0.98; 95% confidence interval [CI], 0.96-0.99; P = .002) and being a responder to stenting (hazard ratio, 0.49; 95% CI, 0.26-0.95; P = .033) increased event-free survival, whereas a history of congestive heart failure (hazard ratio, 2.52; 95% CI, 1.46-4.35; P < .001) and a higher preoperative systolic BP (hazard ratio, 1.02; 95% CI, 1.01-1.03; P = .002) decreased event-free survival. Within the stented group, 105 of 410 patients (25.6%) were responders. Event-free survival was superior for responders, compared with nonresponders (P = .009 by log-rank test). The only independent preoperative negative predictor of improved renal function after stenting was diabetes (odds ratio, 0.37; 95% CI, 0.16-0.84; P = .017), which decreased the probability of improved renal function after RAS + OMT. A subset of patients (23.4%) after RAS had worsened renal function, but OMT alone produced an equivalent incidence of worsened renal function. An increased urine albumin/creatinine ratio was an independent predictor of worsened renal function after RAS. CONCLUSIONS: CORAL participants who demonstrated improved kidney function after RAS + OMT demonstrated improved event-free survival. This finding reinforces the need for predictors of outcome to guide patient selection for RAS.
Assuntos
Aterosclerose , Insuficiência Renal Crônica , Humanos , Artéria Renal , Intervalo Livre de Progressão , Rim/irrigação sanguínea , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia , Aterosclerose/complicações , Aterosclerose/terapia , Aterosclerose/patologia , Fatores de Risco , Taxa de Filtração Glomerular , Resultado do TratamentoRESUMO
The Bifurcation Academic Research Consortium (Bif-ARC) project originated from the need to overcome the paucity of standardization and comparability between studies involving bifurcation coronary lesions. This document is the result of a collaborative effort between academic research organizations and the most renowned interventional cardiology societies focused on bifurcation lesions in Europe, the United States, and Asia. This consensus provides standardized definitions for bifurcation lesions; the criteria to judge the side branch relevance; the procedural, mechanistic, and clinical endpoints for every type of bifurcation study; and the follow-up methods. Considering the complexity of bifurcation lesions and their evaluation, detailed instructions and technical aspects for site and core laboratory analysis of bifurcation lesions are also reported. The recommendations included within this consensus will facilitate pooled analyses and the effective comparison of data in the future, improving the clinical relevance of trials in bifurcation lesions, and the quality of care in this subset of patients.
Assuntos
Doença da Artéria Coronariana , Implante de Prótese de Valva Cardíaca , Humanos , Estados Unidos , Coração , Implante de Prótese de Valva Cardíaca/métodos , Europa (Continente) , Ásia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Resultado do Tratamento , Angiografia CoronáriaRESUMO
BACKGROUND: Randomized trials have demonstrated the superiority of ultrathin strut drug-eluting stents compared with alternative stent designs. Whether these differences persist over late-term follow-up is uncertain. OBJECTIVES: This study sought to compare late-term (5-year) clinical outcomes among patients treated with ultrathin strut (60 µm) bioresorbable polymer sirolimus-eluting stents (BP SES) and thin strut (81 µm) durable polymer everolimus-eluting stents (DP EES). METHODS: BIOFLOW V (Biotronik Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects with Up to Three De Novo or Restenotic Coronary Artery Lesions V) was an international, 2:1 randomized trial comparing percutaneous coronary intervention with ultrathin strut BP SES versus thin strut DP EES regarding the primary endpoint of 12-month target lesion failure (TLF). Prespecified outcomes through 5 years were assessed. RESULTS: Among 1,334 patients randomized to treatment with BP SES (n = 884) or DP EES (n = 450), the 5-year rates of TLF were 12.3% for BP SES and 15.3% for DP EES (P = 0.108). Revascularization with BP SES was associated with a significantly lower target vessel-related myocardial infarction (6.6% vs 10.3%, P = 0.015) and late/very late definite/probable stent thrombosis (0.3% vs 1.6%, P = 0.021). Ischemia-driven target lesion revascularization was numerically but not significantly lower with BP SES (5.9% vs 7.7%, P = 0.202). Cardiac death rates were 2.6% versus 1.9% (P = 0.495) for BP SES and DP EES, respectively. CONCLUSIONS: In a large, randomized trial, TLF and the individual outcomes of cardiac death and target lesion revascularization at 5 years were similar among patients treated with BP SES versus DP EES. Both target vessel-related myocardial infarction and late/very late definite/probable stent thrombosis were significantly lower with BP SES. These results confirm the durability of safety and the effectiveness of percutaneous coronary intervention with ultrathin BP SES.
Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Implantes Absorvíveis , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/terapia , Morte , Everolimo/efeitos adversos , Humanos , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Estudos Prospectivos , Desenho de Prótese , Sirolimo/efeitos adversos , Resultado do TratamentoRESUMO
The Bifurcation Academic Research Consortium (Bif-ARC) project originated from the need to overcome the paucity of standardization and comparability between studies involving bifurcation coronary lesions. This document is the result of a collaborative effort between academic research organizations and the most renowned interventional cardiology societies focused on bifurcation lesions in Europe, the United States, and Asia. This consensus provides standardized definitions for bifurcation lesions; the criteria to judge the side branch relevance; the procedural, mechanistic, and clinical endpoints for every type of bifurcation study; and the follow-up methods. Considering the complexity of bifurcation lesions and their evaluation, detailed instructions and technical aspects for site and core laboratory analysis of bifurcation lesions are also reported. The recommendations included within this consensus will facilitate pooled analyses and the effective comparison of data in the future, improving the clinical relevance of trials in bifurcation lesions, and the quality of care in this subset of patients.
Assuntos
Doença da Artéria Coronariana , Implante de Prótese de Valva Cardíaca , Ásia , Cateterismo Cardíaco/métodos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/terapia , Europa (Continente) , Coração , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Resultado do Tratamento , Estados Unidos/epidemiologiaRESUMO
BACKGROUND: In REDUCE LAP-HF II (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients With Heart Failure), implantation of an atrial shunt device did not provide overall clinical benefit for patients with heart failure with preserved or mildly reduced ejection fraction. However, prespecified analyses identified differences in response in subgroups defined by pulmonary artery systolic pressure during submaximal exercise, right atrial volume, and sex. Shunt implantation reduces left atrial pressures but increases pulmonary blood flow, which may be poorly tolerated in patients with pulmonary vascular disease (PVD). On the basis of these results, we hypothesized that patients with latent PVD, defined as elevated pulmonary vascular resistance during exercise, might be harmed by shunt implantation, and conversely that patients without PVD might benefit. METHODS: REDUCE LAP-HF II enrolled 626 patients with heart failure, ejection fraction ≥40%, exercise pulmonary capillary wedge pressure ≥25 mmâ Hg, and resting pulmonary vascular resistance <3.5 Wood units who were randomized 1:1 to atrial shunt device or sham control. The primary outcome-a hierarchical composite of cardiovascular death, nonfatal ischemic stroke, recurrent HF events, and change in health status-was analyzed using the win ratio. Latent PVD was defined as pulmonary vascular resistance ≥1.74 Wood units (highest tertile) at peak exercise, measured before randomization. RESULTS: Compared with patients without PVD (n=382), those with latent PVD (n=188) were older, had more atrial fibrillation and right heart dysfunction, and were more likely to have elevated left atrial pressure at rest. Shunt treatment was associated with worse outcomes in patients with PVD (win ratio, 0.60 [95% CI, 0.42, 0.86]; P=0.005) and signal of clinical benefit in patients without PVD (win ratio, 1.31 [95% CI, 1.02, 1.68]; P=0.038). Patients with larger right atrial volumes and men had worse outcomes with the device and both groups were more likely to have pacemakers, heart failure with mildly reduced ejection fraction, and increased left atrial volume. For patients without latent PVD or pacemaker (n=313; 50% of randomized patients), shunt treatment resulted in more robust signal of clinical benefit (win ratio, 1.51 [95% CI, 1.14, 2.00]; P=0.004). CONCLUSIONS: In patients with heart failure with preserved or mildly reduced ejection fraction, the presence of latent PVD uncovered by invasive hemodynamic exercise testing identifies patients who may worsen with atrial shunt therapy, whereas those without latent PVD may benefit.
Assuntos
Cateterismo Cardíaco , Átrios do Coração , Insuficiência Cardíaca , Doenças Vasculares , Cateterismo Cardíaco/instrumentação , Feminino , Átrios do Coração/cirurgia , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Circulação Pulmonar , Volume Sistólico , Resultado do Tratamento , Doenças Vasculares/complicaçõesRESUMO
The clinical implications of hypertension in addition to a high prevalence of both uncontrolled blood pressure and medication nonadherence promote interest in developing device-based approaches to hypertension treatment. The expansion of device-based therapies and ongoing clinical trials underscores the need for consistency in trial design, conduct, and definitions of clinical study elements to permit trial comparability and data poolability. Standardizing methods of blood pressure assessment, effectiveness measures beyond blood pressure alone, and safety outcomes are paramount. The Hypertension Academic Research Consortium (HARC) document represents an integration of evolving evidence and consensus opinion among leading experts in cardiovascular medicine and hypertension research with regulatory perspectives on clinical trial design and methodology. The HARC document integrates the collective information among device-based therapies for hypertension to better address existing challenges and identify unmet needs for technologies proposed to treat the world's leading cause of death and disability. Consistent with the Academic Research Consortium charter, this document proposes pragmatic consensus clinical design principles and outcomes definitions for studies aimed at evaluating device-based hypertension therapies.