Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
J Sci Med Sport ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38909002

RESUMO

We evaluated the acute effects of yoga compared to cycling on glucose change and variability, and the occurrence of hypoglycemia in adults with type 1 diabetes. Fifteen participants performed 50 min of cycling or yoga. Glucose values were collected before and after exercise. Coefficient of variation (CV) and hypoglycemic episodes were evaluated from the start up to 12 h after exercise. Cycling and yoga significantly reduced glucose values during exercise, and CV was lower after yoga. One hypoglycemic episode occurred with yoga and seven with cycling. Yoga is a safe exercise that acutely reduces glucose values, but with lower risk of hypoglycemia compared to cycling.

2.
Acta Diabetol ; 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38847923

RESUMO

AIMS: Diastolic dysfunction represents the earliest and most common manifestation of diabetic cardiomyopathy. Nitric oxide (NO), a potent vasodilator and anti-inflammatory mediator released from the subendocardial and coronary endothelium, favors left ventricular distensibility and relaxation. In type 2 diabetes (T2D), the NO bioavailability is reduced due to the oxidative stress and inflammatory state of the endothelium, because of chronic hyperglycemia. The aim of the present research is to evaluate the relationship between endothelial function and diastolic function in subjects with T2D. METHOD: Subjects with T2D and age and sex-matched healthy controls were consecutively recruited. All participants underwent flow-mediated dilation (FMD) to assess endothelial function, and echocardiography to evaluate diastolic function. RESULTS: Thirty-five patients (6 women, 29 men) and 35 healthy controls were included in the final analysis. FMD was significantly lower in T2D than controls (4.4 ± 3.4 vs. 8.5 ± 4.3%, p = 0.001). T2D presented different abnormalities in diastolic function compared to controls: lower E/A (early to late diastolic transmitral flow velocity), lower septal and lateral e' (early diastolic myocardial tissue velocity at septum and lateral wall), and higher E/e' (surrogate of filling pressure). In subjects with T2D, we observed a significant correlation between FMD and E/e' (r = -0.63, p = 0.001), lateral e' (r = 0.44, p = 0.03), and septal e' (r = 0.39, p = 0.05). CONCLUSIONS: Our observational study demonstrated a link between FMD and diastolic dysfunction in subjects with type 2 diabetes.

3.
Diabetes Metab Res Rev ; 40(4): e3811, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38751148

RESUMO

AIMS: Individuals with type 1 diabetes (T1D) do not appear to have an elevated risk of severe Coronavirus Disease 19 (COVID-19). Pre-existing immune reactivity to Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in unexposed individuals may serve as a protective factor. Hence, our study was designed to evaluate the existence of T cells with reactivity against SARS-CoV-2 antigens in unexposed patients with T1D. MATERIALS AND METHODS: Peripheral blood mononuclear cells (PBMCs) were collected from SARS-CoV-2 unexposed patients with T1D and healthy control subjects. SARS-CoV-2 specific T cells were identified in PBMCs by ex-vivo interferon (IFN)γ-ELISpot and flow cytometric assays. The epitope specificity of T cells in T1D was inferred through T Cell Receptor sequencing and GLIPH2 clustering analysis. RESULTS: T1D patients unexposed to SARS-CoV-2 exhibited higher rates of virus-specific T cells than controls. The T cells primarily responded to peptides from the ORF7/8, ORF3a, and nucleocapsid proteins. Nucleocapsid peptides predominantly indicated a CD4+ response, whereas ORF3a and ORF7/8 peptides elicited both CD4+ and CD8+ responses. The GLIPH2 clustering analysis of TCRß sequences suggested that TCRß clusters, associated with the autoantigens proinsulin and Zinc transporter 8 (ZnT-8), might share specificity towards ORF7b and ORF3a viral epitopes. Notably, PBMCs from three T1D patients exhibited T cell reactivity against both ORF7b/ORF3a viral epitopes and proinsulin/ZnT-8 autoantigens. CONCLUSIONS: The increased frequency of SAR-CoV-2- reactive T cells in T1D patients might protect against severe COVID-19 and overt infections. These results emphasise the long-standing association between viral infections and T1D.


Assuntos
COVID-19 , Diabetes Mellitus Tipo 1 , SARS-CoV-2 , Humanos , Diabetes Mellitus Tipo 1/imunologia , SARS-CoV-2/imunologia , COVID-19/imunologia , Masculino , Feminino , Adulto , Linfócitos T/imunologia , Pessoa de Meia-Idade , Estudos de Casos e Controles , Epitopos de Linfócito T/imunologia , Adulto Jovem
4.
Front Health Serv ; 4: 1253905, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38487373

RESUMO

Purpose: The coronavirus pandemic (COVID-19) significantly impacted the global economy and health. Italy was one of the first and most affected countries. The objective of our study was to assess the impact of the pandemic and the vaccination campaign on the radiological examinations performed in a radiology department of a tertiary center in Southern Italy. Materials and methods: We analyzed weekly and retrospectively electronic medical records of case volumes performed at the Radiology Department of "Mater Domini" University Hospital of Catanzaro from March 2020 to March 2022, comparing them with the volumes in the same period of the year 2019. We considered the origin of patients (outpatient, inpatient) and the type of examinations carried out (x-ray, mammography, CT, MRI, and ultrasound). A non-parametric test (Wilcoxon Signed Rank test) was applied to evaluate the average volumes. Results: Total flows in the pandemic period from COVID-19 were lower than in the same pre-pandemic period with values of 552 (120) vs. 427 (149) median (IQR) (p < 0.001). The vaccination campaign allowed the resumption of the pre-vaccination pandemic with total flows 563 (113) vs. 427 (149) median (IQR) p < 0.001. In the post-vaccination period, the number of examinations was found to overlap with the pre-COVID period. Conclusion: The pandemic impacted the volume of radiological examinations performed, particularly with the reduction of tests in outpatients. The vaccination allowed the return to the pre-COVID period imaging case volumes.

5.
Diabetes Res Clin Pract ; 208: 111110, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38278495

RESUMO

AIMS: The study aimed to evaluate blood flow (BF) and microvascular function in the forearm of people with type 1 and type 2 diabetes at rest and after ischemia. Microvascular function plays a crucial role in regulating BF in peripheral tissues based on metabolic demand. METHODS: People with diabetes and sex-matched healthy controls were recruited. Brachial artery diameter and blood velocity were continuously measured at rest and after ischemia by an automatic tracking system. BF and vascular conductance were then calculated. RESULTS: Forty-nine people with diabetes and 49 controls were enrolled. BF at rest and after ischemia was significantly higher in people with diabetes than controls: Type 1, 243 ± 116 and 631 ± 233 ml/min; controls, 180 ± 106 and 486 ± 227 ml/min; Type 2, 332 ± 149 and 875 ± 293 ml/min; controls 222 ± 106 and 514 ± 224 ml/min. Vascular conductance was significantly higher in Type 2 than in controls at rest and after ischemia. CONCLUSIONS: People with diabetes exhibited significantly increased BF, with Type 2 also showing heightened vascular conductance. Activating metabolic pathways triggered by hyperglycemia may lead to distinct vascular redistribution, potentially impairing blood flow over time. These findings of the study underscore the importance of understanding overall vascular dynamics in diabetes and its implications for vascular health.


Assuntos
Diabetes Mellitus Tipo 2 , Humanos , Fluxo Sanguíneo Regional/fisiologia , Hemodinâmica , Antebraço/irrigação sanguínea , Artéria Braquial/fisiologia , Isquemia , Vasodilatação/fisiologia
6.
Endocrine ; 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-37996773

RESUMO

PURPOSE: A remote platform for diabetes care (Roche Diabetes® Care Platform, RDCP) has been developed that allows combined face-to-face consultations and remote patient monitoring (RPM). METHODS: A dedicated flowchart is proposed as a clinical approach to help healthcare professionals in the appropriate interpretation of structured self-monitoring blood glucose data, as visualized on the RDCP during the visits, and in the optimal management of patients using the integrated RDCP-RPM tools. RESULTS: The platform organizes patterns in different blocks: (i) hypoglycemia; (ii) hyperglycemia; (iii) blood glucose variability; (iv) treatment adherence, which identifies a possible individual pattern according to glycemic control challenges, potential causal factors, and behavioral type patterns. The flowchart proposed for use of the RDCP-RPM is self-explanatory and entails 3 steps: (1) evaluation of quality and quantity of self-monitoring blood glucose data; (2) pattern analysis; (3) personalized suggestions and therapy changes. CONCLUSION: The main aim of the remote treatment flowchart proposed is to support healthcare professionals in the identification of hypoglycemic and hyperglycemic patterns using the RDCP regardless of the HbA1c value and ongoing treatment, which however, become crucial in combination with pattern analysis in the therapeutical choice.

7.
J Diabetes Res ; 2023: 9516059, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37096234

RESUMO

Optical coherence tomography angiography (OCTA) is an innovative and reliable technique detecting the early preclinical retinal vascular change in patients with diabetes. We have designed our study to evaluate whether an independent relationship exists between continuous glucose monitoring (CGM)-derived glucose metrics and OCTA parameters in young adult patients with type 1 diabetes without diabetic retinopathy (DR). Inclusion criteria were age ≥ 18 years, diagnosis of type 1 diabetes from ≥ 1 year, stable insulin treatment in the last three months, use of real-time CGM, and CGM wear time ≥ 70%. Each patient underwent dilated slit lamp fundus biomicroscopy to exclude the presence of DR. A skilled operator performed OCTA scans in the morning to avoid possible diurnal variation. CGM-derived glucose metrics from the last 2 weeks were collected through the dedicated software during OCTA. Forty-nine patients with type 1 diabetes (age 29 [18; 39] years, HbA1c 7.7 ± 1.0%) and 34 control subjects participated in the study. Vessel density (VD) of the whole image and parafoveal retina in the superficial (SCP) and deep capillary plexus (DCP) was significantly lower in patients with type 1 diabetes compared to controls. The coefficient of variation of average daily glucose, evaluated by CGM, significantly correlated with foveal and parafoveal VD in SCP and with foveal VD in DCP. High glucose variability might be responsible for the early increase of VD in these areas. Prospective studies may help understand if this pattern precedes DR. The difference we detected between patients with and without diabetes confirms that OCTA is a reliable tool for detecting early retinal abnormalities.


Assuntos
Diabetes Mellitus Tipo 1 , Retinopatia Diabética , Adulto Jovem , Humanos , Adolescente , Adulto , Diabetes Mellitus Tipo 1/diagnóstico , Retinopatia Diabética/diagnóstico , Angiofluoresceinografia/métodos , Vasos Retinianos , Estudos Prospectivos , Benchmarking , Automonitorização da Glicemia , Glicemia , Tomografia de Coerência Óptica/métodos
8.
Artigo em Inglês | MEDLINE | ID: mdl-36900956

RESUMO

BACKGROUND: Continuous glucose monitoring (CGM) users are encouraged to consider trend arrows before injecting a meal bolus. We evaluated the efficacy and safety of two different algorithms for trend-informed bolus adjustments, the Diabetes Research in Children Network/Juvenile Diabetes Research Foundation (DirectNet/JDRF) and the Ziegler algorithm, in type 1 diabetes. METHODS: We conducted a cross-over study of type 1 diabetes patients using Dexcom G6. Participants were randomly assigned to either the DirectNet/JDRF or the Ziegler algorithm for two weeks. After a 7-day wash-out period with no trend-informed bolus adjustments, they crossed to the alternative algorithm. RESULTS: Twenty patients, with an average age of 36 ± 10 years, completed this study. Compared to the baseline and the DirectNet/JDRF algorithm, the Ziegler algorithm was associated with a significantly higher time in range (TIR) and lower time above range and mean glucose. A separate analysis of patients on CSII and MDI revealed that the Ziegler algorithm provides better glucose control and variability than DirectNet/JDRF in CSII-treated patients. The two algorithms were equally effective in increasing TIR in MDI-treated patients. No severe hypoglycemic or hyperglycemic episode occurred during the study. CONCLUSIONS: The Ziegler algorithm is safe and may provide better glucose control and variability than the DirectNet/JDRF over a two-week period, especially in patients treated with CSII.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Criança , Humanos , Adulto , Pessoa de Meia-Idade , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glicemia , Automonitorização da Glicemia , Estudos Cross-Over , Hipoglicemiantes/uso terapêutico , Algoritmos
9.
Nutrients ; 14(16)2022 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-36014822

RESUMO

Despite multiple pharmacological options, including rapid-acting insulin analogs, postprandial hyperglycemia is still highly prevalent in patients with type 1 and type 2 diabetes. We hypothesize that the new rapid-acting insulin formulation, the so-called faster-acting Aspart, may have a different effect in controlling postprandial hyperglycemic burden according to the quality of the meal compared to the traditional Aspart. Twenty-five patients with type 1 diabetes were consecutively recruited at the diabetes care center of the University Hospital affiliate of the Magna Græcia University of Catanzaro. Each patient performed four meal tests one week apart, two with a predefined high glycemic index (HGI) food and two with a low glycemic index (LGI) food using insulin Aspart once and Faster Aspart the other time. The 0-30 min, 0-60 min, and 0-120 min glucose Area Under the Curve (AUC) of postprandial glycemic excursion, calculated from continuous glucose monitoring data, were significantly lower with Faster Aspart administered before the HGI test meal as compared to Aspart. A significant difference in favor of Faster Aspart was also found when comparing the 0-60 min and 0-120 min AUC after the LGI meal. Faster Aspart may provide better postprandial glucose control than Aspart regardless of the glycemic index of the meal.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Hiperglicemia , Glicemia , Automonitorização da Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Índice Glicêmico , Humanos , Hiperglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina , Insulina Aspart/uso terapêutico , Período Pós-Prandial
10.
Life (Basel) ; 12(7)2022 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-35888055

RESUMO

Benign prostatic hyperplasia (BPH) is a common cause of male lower urinary tract symptoms (LUTS) that can reduce quality of life. Even if several drugs can be used in its treatment, the development of adverse drug reactions (ADRs) represents the most common cause of low adherence. In the present study, we evaluate both the efficacy and the safety of a new nutrient fixed combination of Pollen Extract plus Teupolioside, named Xipag®, in patients with LUTS. We conduct a pilot single center open label clinical study between 1 March 2020 and 30 June 2020 in patients with BPH referred to general practitioner's ambulatories. Male patients > 45 years, sexually active, with clinical symptoms of LUTS and with a diagnosis of HPB were enrolled and received one tablet/day of Xipag® (T0), for three months (T1: end of treatment). The IPSS and IIEF-5 questionnaires were carried out at T0 and T1 and represent the first end point, whereas the primary safety end point was considered the absence of ADR or of drug−drug interactions related to Xipag® administration. During the study period, 25 subjects aged 43 to 76 years (mean 62.7 ± 9) were enrolled and completed the study. The clinical evaluation in T1 documented that Xipag® induced a statistically significant improvement (p < 0.01) in symptoms, as documented by the IPSS questionnaire (range 22.7−88.9; mean 55.2 ± 23.6), without the development of ADRs. In conclusion, this is the first real-world study that showed the efficacy and the safety of Xipag® in the BPH patients with LUTS.

11.
Diabetol Metab Syndr ; 14(1): 103, 2022 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-35870966

RESUMO

BACKGROUND: Type 1 diabetes (T1D) is frequently associated with autoimmune thyroiditis (AT) and coeliac disease (CD). Whether the coexistence of multiple autoimmune diseases increases cardiovascular risk is uncertain. We evaluated the effects of AT and CD on arterial wall thickening and endothelial function in patients with T1D. METHODS: This observational study analyzed data from T1D patients regularly followed by the Diabetes Care Centre. Clinical and biochemical characteristics and micro and macrovascular complications were collected from the electronic medical records. All subjects performed Echo-Doppler to evaluate Intima-Media Thickness (IMT) of the common carotid artery (CCA) and endothelial function by the flow-mediated dilation (FMD) technique. The statistical analyses were performed by SPSS for Macintosh. Comparison between means was performed using the t-test for unpaired data and the Mann-Whitney U test. The ANalysis Of VAriance and the Tukey posthoc test were applied to compare patients with and without other autoimmune diseases, and control subjects. The p-value for statistical significance was set at p < 0.05. RESULTS: A total of 110 patients were enrolled. Among these, 69 had T1D and 41 T1D and AT and or CD, of whom 33 AT, 7 CD, and 1 both AT and CD. The mean age was 35 years, mean HbA1c was 7.6%, and mean diabetes duration 18 years. The IMT of the CCA was not significantly different between T1D patients with and without concomitant autoimmune diseases (with AT and CD: right CCA 603 ± 186 µ, left 635 ± 175 µ; without AT and CD: right CCA 611 ± 176 µ, left CCA 631 ± 200 µ). FMD was also comparable between T1D groups, with AT and CD 7.9 ± 4.2%; without AT and CD 8.8 ± 4.4%. CONCLUSION: Patients with T1D and concomitant AT and or CD show no worse morphological or functional vascular damage, evaluated by CCA IMT and brachial artery flow-mediated dilation, than patients with T1D alone.

12.
Pediatr Rep ; 14(2): 175-180, 2022 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-35466203

RESUMO

Tuberculous meningitis (TBM) is a severe form of tuberculosis. We report the development of fatal TBM in a 2-year-old previously healthy child, suggesting that TBM must be evaluated in children of all ages with non-specific symptoms of central nervous involvement because a diagnostic delay induces a negative prognosis.

13.
J Diabetes Sci Technol ; 16(4): 904-911, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-33615850

RESUMO

BACKGROUND: Patients with Type 1 diabetes (T1D) have an increased risk of developing atherosclerosis and complications as myocardial infarction and peripheral artery disease. The thickening of the carotid wall and the brachial artery dysfunction are early and preclinical manifestations of atherosclerosis. The standard marker of care for assessment of glycemic control, glycated hemoglobin, does not associate with early atherosclerosis. We have hypothesized that the emerging metric of glycemic control, as the time spent in the target range (TIR), might be associated with carotid thickening and endothelial dysfunction. According to the hypothesis, we have designed the present research with the aim to evaluate the association between TIR collected in the short and long term and the measures of arterial morphology and function in patients with T1D. METHODS: In our study, 70 patients and 35 healthy controls underwent ultrasound vascular study to measure carotid artery intima-media thickness (IMT) and brachial artery endothelial function by the flow-mediated dilation (FMD) technique. TIR was collected by a continuous glucose monitoring system for 2 weeks, 3 months, and 6 months before the vascular study. RESULTS: Patients with T1D showed a significantly higher carotid IMT (mean±SE, 644±19 vs. 568±29 µ; p= 0.04) and a significantly lower FMD (mean±SE, 7.6±0.4 vs. 9.8±0.6%; p=0.01) compared with control subjects. No significant relationship between IMT, FMD, and TIR collected in the short and long term emerged. CONCLUSIONS: Young patients with T1D have early vascular abnormalities. The percent of TIR does not correlate with preclinical atherosclerosis. This finding underlines the complexity of the interplay between diabetes and atherosclerosis.


Assuntos
Aterosclerose , Diabetes Mellitus Tipo 1 , Aterosclerose/etiologia , Glicemia , Automonitorização da Glicemia/efeitos adversos , Artérias Carótidas/diagnóstico por imagem , Espessura Intima-Media Carotídea , Diabetes Mellitus Tipo 1/complicações , Endotélio Vascular/diagnóstico por imagem , Humanos , Ultrassonografia/efeitos adversos , Vasodilatação
14.
Expert Rev Med Devices ; 18(10): 909-914, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34528851

RESUMO

INTRODUCTION: Continuous glucose monitoring (CGM) systems offer real-time data to facilitate diabetes management. The novel Eversense CGM has been approved in Europe and the US. The unique characteristics are the fully implantable sensor and the sensor life up to 180 days. AREAS COVERED: This expert review describes the results of clinical trials, and the accuracy and safety of the Eversense system. The overall MARD ranges from 8.5% to 9.4%, the 20/20% agreement rate ranges from 84% to 94%, and the percent of values in zones A and B on the Clarke Error Grid is 99.2%. No device-related serious adverse events have been described during pivotal trial studies. The most frequently reported device- or procedure-related adverse events are sensor adhesive patch location site irritation (0.66%), inability to remove the sensor upon first attempt (0.76%), and location site infection (0.96%). Mean A1c reduction is about 0.4% from pivotal trials and real-world studies. EXPERT OPINION: The Eversense system is novel and differentiated from transcutaneous CGM systems. The long life, the removable transmitter, and the on-body vibration alerts offer opportunities to properly manage diabetes with both MDI and insulin pump therapy.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Controle Glicêmico , Humanos , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
15.
Nutrients ; 13(7)2021 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-34371945

RESUMO

Post-prandial hyperglycemia can be relevant in developing early manifestations of atherosclerosis. EVOO (Extra Virgin Olive Oil), rich in saturated fatty acids and commonly used in the Mediterranean diet, seems to control post-prandial hyperglycemia better than butter. Subjects with type 1 diabetes are at higher risk of developing cardiovascular disease and show endothelial dysfunction, an early manifestation of atherosclerosis in the first years of the disease. Our study aims to evaluate whether EVOO and butter influence endothelial function in subjects with type 1 diabetes when added to a single high glycemic index (HGI) meal. In this exploratory cross-over study, 10 subjects with type 1 diabetes and 6 healthy subjects were scheduled to receive two types of HGI meals: one enriched with EVOO and one with butter. Before and after each test meal at different time points, all subjects underwent the evaluation of endothelial function by flow-mediated dilation technique, glucose and lipids measurements, and gastric emptying assessment by ultrasound. Flow-mediated dilation significantly increased after EVOO-enriched meal compared with butter in subjects with type 1 diabetes (two-way-repeated measurements ANOVA, p = 0.007). In patients with type 1 diabetes, the add-on of EVOO to HGI meal improves vascular function compared to butter, which has detrimental effects.


Assuntos
Manteiga , Diabetes Mellitus Tipo 1/fisiopatologia , Gorduras na Dieta , Endotélio Vascular/fisiopatologia , Azeite de Oliva , Adulto , Velocidade do Fluxo Sanguíneo , Glicemia/análise , Pressão Sanguínea , Estudos Cross-Over , Feminino , Esvaziamento Gástrico , Índice Glicêmico , Humanos , Lipídeos/sangue , Masculino , Vasodilatação
16.
Int J Cardiol ; 336: 8-13, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34052238

RESUMO

Background A new imaging metric using coronary computed tomography angiography (CCTA), addressing the peri-coronary adipose tissue (PCAT) computed tomography (CT) attenuation, has been clinically validated. This method provides information regarding coronary inflammation. It is unclear how coronary inflammation affects microvascular function. The non-invasive evaluation of coronary flow velocity reserve is widely used in clinical practice using Doppler measurement on the left anterior descending coronary artery (CFVR-lad) during stress-echocardiography (SE). We hypothesize that coronary inflammation affects CFVR-lad and, in the absence of overt CAD, they are significantly correlated. Methods We evaluated the relationship between coronary inflammation (by PCAT CT attenuation) and coronary microvascular function (by CFVR-lad) in subjects with no or non-obstructive (diameter stenosis <70%) coronary artery disease (CAD). Results Two-hundred and two subjects were enrolled in the study. The relationship between PCAT CT attenuation and CFVR-lad show a significant inverse relationship in the entire group of subjects enrolled in the study (r = -0.32, p < 0.001). Correlation between PCAT CT attenuation and CFVR-lad was significant in subjects with no or mild CAD-lad, while this was not the case in subjects with intermediate CAD-lad. The R and R2 were respectively -0.40, -0.16 in subjects without CAD (p < 0.001) and - 0.35 and - 0.12 in subjects with mild CAD-lad (p = 0.001). Conclusions The main finding of the current study is the independent relationship between coronary microvascular function, by Doppler CFVR-lad during SE, in subjects without severely obstructive CAD in the left anterior descending coronary artery, and the level of local coronary inflammation, by PCAT attenuation measurement on CCTA.


Assuntos
Angiografia por Tomografia Computadorizada , Vasos Coronários , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Humanos , Inflamação/diagnóstico por imagem , Tomografia Computadorizada por Raios X
17.
J Med Internet Res ; 23(4): e24552, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33769945

RESUMO

BACKGROUND: Telemedicine use in chronic disease management has markedly increased during health emergencies due to COVID-19. Diabetes and technologies supporting diabetes care, including glucose monitoring devices, software analyzing glucose data, and insulin delivering systems, would facilitate remote and structured disease management. Indeed, most of the currently available technologies to store and transfer web-based data to be shared with health care providers. OBJECTIVE: During the COVID-19 pandemic, we provided our patients the opportunity to manage their diabetes remotely by implementing technology. Therefore, this study aimed to evaluate the effectiveness of 2 virtual visits on glycemic control parameters among patients with type 1 diabetes (T1D) during the lockdown period. METHODS: This prospective observational study included T1D patients who completed 2 virtual visits during the lockdown period. The glucose outcomes that reflected the benefits of the virtual consultation were time in range (TIR), time above range, time below range, mean daily glucose, glucose management indicator (GMI), and glycemic variability. This metric was generated using specific computer programs that automatically upload data from the devices used to monitor blood or interstitial glucose levels. If needed, we changed the ongoing treatment at the first virtual visit. RESULTS: Among 209 eligible patients with T1D, 166 completed 2 virtual visits, 35 failed to download glucose data, and 8 declined the visit. Among the patients not included in the study, we observed a significantly lower proportion of continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusion (CSII) users (n=7/43, 16% vs n=155/166, 93.4% and n=9/43, 21% vs n=128/166, 77.1%, respectively; P<.001) compared to patients who completed the study. TIR significantly increased from the first (62%, SD 18%) to the second (65%, SD 16%) virtual visit (P=.02); this increase was more marked among patients using the traditional meter (n=11; baseline TIR=55%, SD 17% and follow-up TIR=66%, SD 13%; P=.01) than among those using CGM, and in those with a baseline GMI of ≥7.5% (n=46; baseline TIR=45%, SD 15% and follow-up TIR=53%, SD 18%; P<.001) than in those with a GMI of <7.5% (n=120; baseline TIR=68%, SD 15% and follow-up TIR=69%, SD 15%; P=.98). The only variable independently associated with TIR was the change of ongoing therapy. The unstandardized beta coefficient (B) and 95% CI were 5 (95% CI 0.7-8.0) (P=.02). The type of glucose monitoring device and insulin delivery systems did not influence glucometric parameters. CONCLUSIONS: These findings indicate that the structured virtual visits help maintain and improve glycemic control in situations where in-person visits are not feasible.


Assuntos
Automonitorização da Glicemia , COVID-19 , Diabetes Mellitus Tipo 1/tratamento farmacológico , SARS-CoV-2 , Telemedicina , Adulto , Diabetes Mellitus Tipo 1/sangue , Feminino , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Masculino , Projetos Piloto , Estudos Prospectivos
18.
Nutr Metab Cardiovasc Dis ; 30(10): 1800-1805, 2020 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-32669240

RESUMO

BACKGROUND AND AIMS: Self-monitoring blood glucose (SMBG) remains a widespread tool to monitor blood glucose. The development of diabetes management systems (DMS) allows SMBG to provide additional information as time spent in target range (TIR). This study evaluates the association between HbA1c and TIR, evaluated through DMS, over 2 months, and 2 weeks. METHODS AND RESULTS: Type 1 (T1D) and Type 2 (T2D) insulin-treated patients with diabetes were enrolled. We used the term PIR (Points in Range) instead of TIR, since SMBG provides point-in-time glucose values rather than a continuous trend over time. PIR was calculated in 2-month and 2-week time ranges before available HbA1c measurement. One-hundred ninety-seven patients with T1D and 36 with T2D were recruited. HbA1c and PIR were inversely associated (2 months: R -0.72, 2 weeks R -0.70; p < 0.0001) in all subjects. The relationship did not change when T1D and T2D patients were analyzed separately. For every 10% change of PIR, there was a change of HbA1c by 0.4%. CONCLUSIONS: Our study, for the first time, demonstrates a significant correlation between HbA1c and PIR calculated by DMS. DMS offers additional information useful in disease management of patients with T1D and T2D performing SMBG.


Assuntos
Automonitorização da Glicemia , Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hemoglobinas Glicadas/metabolismo , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Adulto , Idoso , Biomarcadores/sangue , Glicemia/metabolismo , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
19.
Sci Rep ; 10(1): 12070, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32694667

RESUMO

Subjects with Neurofibromatosis 1 (NF1) develop vascular complications. The protein product of the gene affected in NF1, neurofibromin, physiologically modulates endothelial function and preserves vascular and myocardial structure. Our study aimed to verify whether subjects with NF1 have early, preclinical abnormalities of carotid artery structure, brachial artery function, and cardiac function. We recruited 22 NF1 subjects without previous cardiovascular events and 22 healthy control subjects. All subjects underwent measurement of carotid artery intima-media thickness (IMT), evaluation of brachial artery endothelial function after ischemia and exercise, and cardiac function. Mean IMT was 543 ± 115 µ in NF1 subjects and 487 ± 70 µ in Controls (p < 0.01). Endothelial function was significantly dumped in NF1 subjects. The dilation after ischemia and exercise was respectively 7.5(± 4.8)% and 6.7(± 3.0)% in NF1 versus 10.5(± 1.2)% and 10.5(± 2.1)% in control subjects (p < 0.02; p < 0.002). Left ventricular systolic function assessed by Global Longitudinal Strain was significantly different between NF1 subjects and Controls: - 19.3(± 1.7)% versus - 21.5(± 2.7)% (p < 0.008). These findings demonstrate that NF1 patients have early morphological and functional abnormalities of peripheral arteries and systolic cardiac impairment and suggest the need for a tight cardiovascular risk evaluation and primary prevention in subjects with NF1.


Assuntos
Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/etiologia , Suscetibilidade a Doenças , Neurofibromatose 1/complicações , Adolescente , Adulto , Biomarcadores , Viscosidade Sanguínea , Doenças Cardiovasculares/patologia , Doenças Cardiovasculares/fisiopatologia , Artérias Carótidas/metabolismo , Artérias Carótidas/fisiopatologia , Feminino , Testes de Função Cardíaca , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
20.
Diabetes Obes Metab ; 22(7): 1056-1061, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32037699

RESUMO

AIMS: This real-world study evaluated the changes in glycated haemoglobin (HbA1c) and continuous glucose monitoring (CGM) metrics associated with use of the implantable 180-day Eversense CGM System (Eversense) in patients with type 1 diabetes. MATERIALS AND METHODS: This was a prospective, multicentre, observational study among adult participants aged ≥18 years with type 1 diabetes across seven diabetes-care centres in Italy who had Eversense inserted for the first time. HbA1c was measured at baseline and at 180 days. Changes in time in range [TIR (glucose 70-180 mg/dL)], time above range [TAR (glucose >180 mg/dL)], time below range [TBR (glucose <70 mg/dL)] and glycaemic variability were also assessed. Data were also analysed by previous CGM use and by mode of insulin delivery. RESULTS: One-hundred patients were enrolled (mean age 36 ± 12 years, mean baseline HbA1c 7.4 ± 0.92% [57 ± 10 mmol/mol]). Fifty-six per cent of patients were users of the continuous subcutaneous insulin infusion pump and 45% were previous users of CGM. HbA1c significantly decreased in patients after 180 days of sensor wear (-0.43% ± 0.69%, 5 ± 8 mmol/mol, P < 0.0001). As expected, CGM-naïve patients achieved the greatest reduction in HbA1c (-0.74% ± 0.48%, 8 ± 5 mmol/mol). TIR significantly increased and TAR and mean daily sensor glucose significantly decreased while TBR did not change after 180 days of sensor wear. CONCLUSIONS: Real-world clinical use of the Eversense CGM System for 180 days was associated with significant improvements in HbA1c and CGM metrics among adults with type 1 diabetes. The study is registered on clinicaltrials.gov (NCT04160156).


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Humanos , Insulina , Itália , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA