Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Dent ; 145: 104998, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38636650

RESUMO

OBJECTIVES: The study aimed to introduce a novel two-step optical fiber-based photo-activation of dental resin-based composites (RBCs) for reducing polymerization shrinkage stress (PSS). METHODS: Proposed protocol design - in the first step, two flexible plastic optical fibers connected to a dental light curing unit (LCU), were used as light guides inserted into the filling to initiate low-irradiance polymerization from within; in the second step, fibers were extracted and remaining voids were filled with RBC, followed by conventional high-irradiance curing to finalize polymerization. Three bulk-fill RBCs were tested (Beautifil-Bulk Restorative, Filtek Bulk-fill Posterior, Tetric PowerFill) using tooth cavity models. Three non-invasive examination techniques were employed: Digital Holographic Interferometry, Infrared Thermography, and Raman spectroscopy for monitoring model deformation, RBC temperature change, and degree of conversion (DC), respectively. A control group (for each examined RBC) underwent conventional photo-activation. RESULTS: The experimental protocol significantly reduced model deformation by 15 - 35 %, accompanied by an 18 - 54 % reduction in RBC temperature change, emphasizing the impact of thermal shrinkage on PSS. Real-time measurements of deformation and temperature provided indirect insights into reaction dynamics and illuminated potential mechanisms underlying PSS reduction. After a 24-hour dark-storage period, DC outcomes comparable to conventional curing were observed, affirming the clinical applicability of the method. CONCLUSIONS: Protocol involving the use of two 1.5 mm fibers in the first step (300 mW/cm2 x 10 s), followed by a second conventional curing step (1000 mW/cm2 x 10 s), is recommended to achieve the desired PSS reduction, while maintaining adequate DC and ensuring efficient clinical application. CLINICAL SIGNIFICANCE: Obtained PSS reduction offers promise in potentially improving the performance of composite restorations. Additionally, leveraging the flexibility of optical fibers improves light guide approach for restorations on posterior teeth. Meanwhile, implementation in clinical practice is easily achievable by coupling the fibers with commercial dental LCUs using the provided plastic adapter.


Assuntos
Resinas Compostas , Teste de Materiais , Fibras Ópticas , Polimerização , Resinas Compostas/química , Resinas Compostas/efeitos da radiação , Humanos , Lâmpadas de Polimerização Dentária , Materiais Dentários/química , Materiais Dentários/efeitos da radiação , Temperatura , Análise Espectral Raman , Cura Luminosa de Adesivos Dentários/métodos , Estresse Mecânico , Propriedades de Superfície
2.
J Clin Med ; 12(13)2023 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-37445506

RESUMO

BACKGROUND AND OBJECTIVES: The aim of the research was to investigate the differences in the concentrations of IL-12, IL-4, IL-10, and IFN-γ in tears after LASIK and PRK procedures. MATERIALS AND METHODS: The study included 68 myopic eyes up to -3.0 D refractive spherical equivalent, divided into two groups: Group 1 LASIK (n = 31) and Group 2 PRK (n = 37). Three tear samples were taken from each eye: immediately before the procedure (t0), 1 h after the procedure (t1), and 24 h after the procedure (t2). The concentrations of IL-12p70, IL-4, IL-10, and IFN-γ in the tear samples were determined by flow cytometry. Participants were not taking anti-inflammatory therapy 24 h after the procedure. RESULTS: IL-4 levels 1 h after treatment did not differ between LASIK and PRK (p = 0.990), while 24 h after PRK there was a significant decrease in IL-4 levels (p < 0.05), but not after LASIK (p = 0.476). In both the LASIK (p < 0.05) and PRK (p < 0.05) groups, there is an increase in IL-10 concentrations 1 h after treatment, which persists 24 h after LASIK (p < 0.05) but not after PRK (p = 0.081). There is an increase in IL-12p70 concentration 1 h after treatment in both the LASIK (p < 0.001) and PRK groups (p < 0.001). There is also an increase in IL-12p70 concentration 24 h after PRK (p < 0.005), but not after LASIK (p = 0.775). CONCLUSIONS: IL-4 concentration shows a significantly higher value in the LASIK group than in the PRK group after 24 h. IL-10 and IL-12p70 levels increase one hour after surgery in both groups. After 24 h, the IL-10 levels remain elevated in the LASIK group, and the IL-12p70 levels remain elevated in the PRK group. Thus, LASIK and PRK procedures show different inflammatory dynamics.

3.
Micromachines (Basel) ; 14(5)2023 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-37241632

RESUMO

Planning astigmatic correction is a complex task. Biomechanical simulation models are useful for predicting the effects of the physical procedure on the cornea. Algorithms based on these models allow preoperative planning and simulate the outcome of patient-specific treatment. The objective of this study was to develop a customised optimisation algorithm and determine the predictability of astigmatism correction by femtosecond laser arcuate incisions. In this study, biomechanical models and Gaussian approximation curve calculations were used for surgical planning. Thirty-four eyes with mild astigmatism were included, and corneal topographies were evaluated before and after femtosecond laser-assisted cataract surgery with arcuate incisions. The follow-up time was up to 6 weeks. Retrospective data showed a significant reduction in postoperative astigmatism. A total of 79.4% showed a postoperative astigmatic value less than 1 D. Clinical refraction was significantly reduced from -1.39 ± 0.79 D preoperatively to -0.86 ± 0.67 D postoperatively (p 0.02). A positive reduction in topographic astigmatism was also observed (p < 0.00). The best-corrected visual acuity increased postoperatively (p < 0.001). We can conclude that customised simulations based on corneal biomechanics are a valuable tool for correcting mild astigmatism with corneal incisions in cataract surgery to improve postoperative visual outcomes.

4.
Medicina (Kaunas) ; 59(4)2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-37109597

RESUMO

Background: The aim of the study was to compare macular thickness behavior and clinical outcomes after femtosecond laser-assisted cataract surgery (FLACS) versus phacoemulsification conventional surgery (PCS). Methods: Macular Optical Coherence Tomography OCT was analyzed in 42 patients preoperatively, 1 day, 12 days, 4 weeks and 6 weeks postoperatively according to the 9-field Early Treatment Diabetic Retinopathy Study (ETDRS) grid. Clinical findings were collected in both the FLACS group and the PCS group. Results: There was no significant difference in macular thickness between the FLACS and PCS groups (p > 0.05). However, from postoperative day 12 onwards, there was a significant increase in macular thickness observed in both groups (p < 0.001). In the FLACS group, a significant increase in visual acuity was observed on the first postoperative day, as compared to the PCS group (p = 0.006). Conclusions: The use of a low-energy high-frequency femtosecond laser has potentially no effect on postoperative macular thickness. In the FLACS group, visual rehabilitation was significantly faster as compared to the PCS group. No complications occurred intraoperatively in either group.


Assuntos
Extração de Catarata , Catarata , Terapia a Laser , Facoemulsificação , Humanos , Terapia a Laser/métodos , Facoemulsificação/métodos , Lasers
5.
J Clin Med ; 12(2)2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36675659

RESUMO

In the early 2000s, solid-state lasers emerged as an alternative technology to excimer systems in refractive surgery. Despite some technological limits at the time, good clinical results could be achieved with solid-state laser systems. This prospective case series reports clinical outcomes of five eyes treated with a newly developed solid-state laser system (AquariuZ) in three patients. Patients underwent preoperative examination, including corneal topo-and tomography, aberrometry, and confocal microscopy. All patients received a femtosecond LASIK with the Ziemer LDV Z8, a refractive treatment with the AquariuZ solid-state ablation laser, and were then followed up for a period of up to 12 months. The applied aspheric optimized profiles did not induce higher-order aberrations nor spherical aberration in any of these operated subjects. No eye lost BCVA lines throughout the duration of the follow-up. Six months after surgery, the safety index of patient 1 was 5, and for patients 2 and 3, it equaled 1. Confocal laser microscopy imaging findings were comparable to those seen typically for excimer lasers. The obtained results are encouraging and confirm that the new solid-state laser system is safe.

6.
R Soc Open Sci ; 8(7): 202365, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34350012

RESUMO

The influence of different processing parameters and various Ba2+ addition (up to 10 mol%) on the structure and dielectric properties of Bi0.5Na0.5TiO3-BaTiO3 (BNT-BT) ceramics was investigated. The powders were hydrothermally synthesized in the alkaline environment at 180°C for different time periods. X-ray diffraction confirmed the presence of dominant rhombohedral Bi0.5Na0.5TiO3 phase and a small amount of secondary pyrochlore Bi2Ti2O7 phase in the pure BNT powders. In addition, one-dimensional Na2Ti2O7 structure was also observed in the powder hydrothermally treated for a long time (i.e. 48 h). The amount of secondary pyrochlore phase in the BNT-BT powders increases with the increase of Ba2+ content. The synthesized powders were pressed into pellets and finally sintered at various temperatures up to 1150°C. High density (more than 90%TD) was obtained in all BNT-BT sintered samples. Optimal sintering parameters were chosen in order to obtain dense ceramics with the optimal phase composition. The temperature dependence of dielectric properties for the BNT-BT ceramics was also studied. Relaxor behaviour of BNT-based ceramics and broad transition peaks are evident in all samples. Dielectric constant up to 400 as well as an acceptable low dielectric loss at temperatures lower than 200°C were obtained in BNT-BT ceramics.

7.
Medicina (Kaunas) ; 57(7)2021 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-34356980

RESUMO

The power density of femtosecond lasers and exposure time to the tissue are crucial for a successful procedure in terms of safety and precision. The reduction of the pulse duration allows reducing the quantity of the energy to be delivered to the tissue for disruption with strongly diminished mechanical and thermal collateral damage. The cutting effect of ultra-short pulses is very precise, minimally traumatic, safe, and predictable. Future developments will lead to further energy reductions to achieve optical breakdowns. However, the pulse length cannot be shortened arbitrarily because below 100 fs nonlinear effects can change the process in an unfavorable way. Compared to manual-conventional cataract surgery, femtosecond laser-assisted cataract surgery (FLACS) shows many advantages in clinical application, especially with regard to precision and tissue protection. The femtosecond laser has become particularly important and has made the overall procedure safer when we deal with complex cataract cases such as subluxated lenses. We provide an overview of the evolution of femtosecond laser technology for use in refractive and cataract surgeries. This article describes the advantages of available laser platforms with ultrashort pulses and mainly focuses on the technical and physical backgrounds of ophthalmic surgery technologies.


Assuntos
Extração de Catarata , Catarata , Terapia a Laser , Oftalmologia , Humanos
8.
J Clin Med ; 10(16)2021 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-34441768

RESUMO

BACKGROUND: The aim of the study is to investigate whether the circadian IOP rhythm can be influenced by combined cataract surgery with high frequency deep sclerotomy (HFDS) and whether intraocular pressure (IOP) can be significantly reduced by HFDS. METHODS: In our study 10 patients were included, in whom 24 h IOP monitoring was installed before and after HFDS/cataract surgery using a Triggerfish. HFDS is a minimally invasive glaucoma surgery (MIGS). RESULTS: After performed HFDS combined with cataract surgery, the IOP was reduced from 27.7 ± 2.11 mmHg to 14.4 ± 2.59 mmHg, which is highly significant (p < 0.001). The contact lens sensor (CLS) cosinor analysis pre- and postoperatively showed that the circadian rhythm is not influenced by the surgery, i.e., the circadian IOP rhythm did not show significant differences before and after surgery. CONCLUSIONS: HFDS combined with cataract surgery is a potent surgical method that can significantly reduce the IOP. However, the circadian rhythm cannot be changed by the surgery. The acrophase remained during the night in all patients.

9.
J Clin Med ; 10(11)2021 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-34070242

RESUMO

BACKGROUND: Presbyopia treatment in pseudophakic patients with a monofocal IOL is challenging. This study investigates the refractive results of femto-PresbyLASIK and analyzes presbyopia treatment in pseudophakic eyes. METHODS: 14 patients with 28 pseudophakic eyes were treated with femto-PresbyLASIK. The dominant eye was targeted at a distance and the non-dominant eye at -0.5 D. The presbyopic algorithm creates a steepness in the cornea center by using an excimer laser that leads to corneal multifocality. RESULTS: 6 months after surgery a refraction of -0.11 ± 0.13 D (p = 0.001), an uncorrected distance visual acuity of 0.05 ± 1.0 logMAR (p < 0.001) and an uncorrected near visual acuity of 0.15 ± 0.89 logMAR (p = 0.001) were achieved in the dominant eye. For the non-dominant eye, the refraction was -0.28 ± 0.22 D (p = 0.002), the uncorrected distance of visual acuity was 0.1 ± 1.49 logMAR, and the uncorrected near visual acuity was 0.11 ± 0.80 logMAR (p < 0.001). Spherical aberrations (Z400) were reduced by 0.21-0.3 µm in 32% of eyes, and by 0.31-0.4 µm in 26% of eyes. CONCLUSION: By steepening the central cornea while maintaining spherical aberrations within acceptable limits, PresbyLASIK created a corneal multifocality that safely improved near vision in both eyes. Thus, femto-PresbyLASIK can be used to treat presbyopia in pseudophakic eyes without performing intraocular surgery.

10.
Sensors (Basel) ; 21(7)2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33808502

RESUMO

Phacoemulsification is a widely used surgical method in cataract surgery with a high energy ultrasound source. The viscoelastic is considered to be tissue protective. The aim of this study is to investigate during surgery the impact of using viscoelastic versus no viscoelastic on clinical outcomes, potential complications and effect on endothelial cell density. The study group included 64 patients, who were subjected to phacoemulsification using balanced salt solution (BSS). Control group consisted of 62 patients, who underwent phacoemulsification using Hyaloronic acid 1% Healon 1%. Student's t-test was applied for statistical analysis. The simulations of temperature changes during phacoemulsification were performed by COMSOL Multiphysics software. In the BSS group, a mean endothelial cell loss (ECL) of 4.5% was measured one month postoperatively, while in the Healon group ECL was 5.3%. Data analysis showed no significant difference in ECL between the groups (Student's t-test, p = 0.8). No significant difference was observed in endothelial cell morphology and IOP between the two groups pre- and postoperatively (all p > 0.05). The modeling of thermo fluid dynamics showed that the heating of the cornea is slightly less when Healon was used as irrigation fluid. The phacoemulsification technique can be performed by an experienced surgeon with viscoelastics or continuous anterior chamber (AC) irrigation on the same level of safety regarding endothelial cell damage, providing equally satisfying clinical outcomes.


Assuntos
Facoemulsificação , Contagem de Células , Células Endoteliais , Humanos , Hidrodinâmica , Pressão Intraocular , Estudos Prospectivos
11.
Sensors (Basel) ; 21(3)2021 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-33540506

RESUMO

BACKGROUND: It is known that pterygia above a certain size cause astigmatism and other aberrations of the human cornea and thus impair the quality of vision. Exclusive Sr-/Ytt-90 beta irradiation is a highly effective treatment for primary pterygia. The aim of this retrospective study is to determine the extent to which higher order corneal aberrations are affected by this treatment. METHODS: Evaluation of corneal topographies and wavefront aberration data of 20 primary pterygia patients generated before and at different points in time in the first year after irradiation. Additionally, the size of the pterygium was measured. RESULTS: The study showed a significant increase in coma and triple leaf aberrations in pterygia with a horizontal length of 2 mm and more. It was also found that a pterygium size greater than 2 mm significantly induces astigmatism. Both phenomena reduce visual quality. In none of the patients could a pterygium recurrence be detected after irradiation. CONCLUSIONS: If the pterygium size is less than 2 mm, early exclusive Sr/Ytt-90 beta irradiation can be recommended. If the size is more than 2 mm, a pterygium excision 6 months after beta irradiation can be discussed.


Assuntos
Córnea , Pterígio , Radioisótopos de Estrôncio , Adulto , Idoso , Técnicas Biossensoriais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pterígio/radioterapia , Estudos Retrospectivos , Radioisótopos de Ítrio
12.
Sensors (Basel) ; 21(3)2021 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-33540680

RESUMO

Femtosecond laser-assisted cataract surgery has the potential to make critical steps of cataract surgery easier and safer, and reduce endothelial cell loss, thus, improving postoperative outcomes. This study compared FLACS with the conventional method in terms of endothelial cells behavior, clinical outcomes, and capsulotomy precision. METHODS: In a single-center, randomized controlled study, 130 patients with cataracta senilis received FLACS or conventional cataract surgery. RESULTS: A significant endothelial cell loss was observed postoperatively, compared to the preoperative values in both groups. The endothelial cell counts was significantly better in the FLACS group in cataract grade 2 (p = 0.048) patients, compared to conventionally at 4 weeks. The effective phaco time was notably shorter in grade 2 of the FLACS group (p = 0.007) compared to the conventional. However, no statistically significant differences were found for the whole sample, including all cataract grades, due to the overall cataract density in the FLACS group being significantly higher (2.60 ± 0.58, p < 0.001) as compared to conventional methods (2.23 ± 0.42). CONCLUSIONS: Low energy FLACS provides a better result compared to endothelial cell loss, size, and shape variations, as well as in effective phaco time within certain cataract grade subgroups. A complete comparison between two groups was not possible because of the higher cataract grade in the FLACS. FLACS displayed a positive effect on endothelial cell preservation and was proven to be much more precise.


Assuntos
Extração de Catarata/métodos , Catarata , Terapia a Laser , Ultrassonografia , Catarata/diagnóstico , Células Endoteliais , Humanos , Lasers , Acuidade Visual
13.
Sensors (Basel) ; 20(21)2020 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-33171890

RESUMO

This study aims to discuss the synthesis and fabrication of SnO2-In2O3-based thick-films and their biosensing applications. The structural characterization of SnO2-In2O3 nanocomposites was performed using X-ray diffraction, Raman spectroscopy and transmission electron microscopy. Furthermore, the screen-printing technology was used in the fabrication of conductive electrodes to form an interdigitated capacitive structure, and the sensor layer based on the mixture of SnO2 and In2O3. Moreover, the sensing performance of the developed structure was tested using Pseudomonas aeruginosa (P. aeruginosa) and Staphylococcus aureus (S. aureus) bacteria. In addition, the validation of sensing characteristics was performed by electrochemical impedance spectroscopic and self-resonant frequency analysis. Finally, the sensing properties were analyzed for two consecutive days, and changes in both P. aeruginosa and S. aureus pathogens growing media were also studied.


Assuntos
Nanocompostos , Staphylococcus aureus , Técnicas Biossensoriais , Eletrodos , Difração de Raios X
14.
Sensors (Basel) ; 17(6)2017 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-28608800

RESUMO

Laser Assisted in Situ Keratomileusis (LASIK) is a proven treatment method for corneal refractive surgery. Surgically induced higher order optical aberrations were a major reason why the method was only rarely used to treat presbyopia, an age-related near-vision loss. In this study, a novel customization algorithm for designing multifocal ablation patterns, thereby minimizing induced optical aberrations, was used to treat 36 presbyopic subjects. Results showed that most candidates went from poor visual acuity to uncorrected 20/20 vision or better for near (78%), intermediate (92%), and for distance (86%) vision, six months after surgery. All subjects were at 20/25 or better for distance and intermediate vision, and a majority (94%) were also better for near vision. Even though further studies are necessary, our results suggest that the employed methodology is a safe, reliable, and predictable refractive surgical treatment for presbyopia.


Assuntos
Presbiopia , Humanos , Hiperopia , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Resultado do Tratamento , Acuidade Visual
15.
Sensors (Basel) ; 17(6)2017 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-28587100

RESUMO

A prospective comparative study assessing the importance of the intra-operative dynamic rotational tracking-especially in the treatment of astigmatisms in corneal refractive Excimer laser correction-concerning clinical outcomes is presented. The cyclotorsion from upright to supine position was measured using iris image comparison. The Group 1 of patients was additionally treated with cyclorotational control and Group 2 only with X-Y control. Significant differences were observed between the groups regarding the mean postoperative cylinder refraction (p < 0.05). The mean cyclotorsion can be calculated to 3.75° with a standard deviation of 3.1°. The total range of torsion was from -14.9° to +12.6°. Re-treatment rate was 2.2% in Group 1 and 8.2% in Group 2, which is highly significant (p < 0.01). The investigation confirms that the dynamic rotational tracking system used for LASIK results in highly predictable refraction quality with significantly less postoperative re-treatments.


Assuntos
Lasers de Excimer , Humanos , Iris , Miopia , Estudos Prospectivos , Refração Ocular , Resultado do Tratamento
16.
Sensors (Basel) ; 17(6)2017 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-28629164

RESUMO

BACKGROUND: The aim of our study was to investigate the safety and efficacy of the LDV Z8 femtosecond laser in cataract surgery compared to the conventional procedure. METHODS: This prospective study was performed at the Swiss Eye Research Foundation, Eye Clinic ORASIS, Reinach, Switzerland. The study included 130 eyes from 130 patients: 68 treated with femtosecond laser-assisted cataract surgery (FLACS) using the FEMTO LDV Z8 and 62 treated with conventional phacoemulsification. Capsulotomy and lens fragmentation in the laser group were performed with the FEMTO LDV Z8 femtosecond laser system, which employs a new, low-energy, high repetition rate laser process for cataract surgery. In the conventional group, the capsulotomy was performed by a cystotome, and lens fragmentation was achieved by the stop-and-chop. RESULTS: Ease of phacoemulsification (on a 4-point scale), the completeness of capsulotomy (on a 10-point scale), effective phacoemulsification time (seconds), uncorrected distance visual acuity (UCVA), best spectacle-corrected distance visual acuity (BSCVA), spherical equivalent (SE), and safety of the procedure were evaluated. The total follow-up time was three months. CONCLUSIONS: FLACS with the FEMTO LDV Z8 system was characterized by complete and reproducible capsulotomy and highly effective lens fragmentation. Postoperative visual outcomes were excellent, and the safety of the procedure was optimal.

17.
Clin Ophthalmol ; 10: 1343-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27555741

RESUMO

PURPOSE: Pterygium is a common lesion affecting the population in countries with high levels of ultraviolet exposure. The final shape of a pterygium is the result of a growth pattern, which remains poorly understood. This manuscript provides a mathematical analysis as a tool to determine the shape of human pterygia. MATERIALS AND METHODS: Eighteen patients, all affected by nasal unilateral pterygia, were randomly selected from our patient database independently of sex, origin, or race. We included all primary or recurrent pterygia with signs of proliferation, dry eye, and induction of astigmatism. Pseudopterygia were excluded from this study. Pterygia were outlined and analyzed mathematically using a Cartesian coordinate system with two axes (X, Y) and five accurate landmarks of the pterygium. RESULTS: In 13 patients (72%), the shape of the pterygia was hyperbolic and in five patients (28%), the shape was rather elliptical. CONCLUSION: This analysis gives a highly accurate mathematical description of the shape of human pterygia. This might help to better assess the clinical results and outcome of the great variety of therapeutic approaches concerning these lesions.

18.
Clin Ophthalmol ; 10: 1245-56, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27478365

RESUMO

PURPOSE: To report the visual outcomes of the femtosecond laser-assisted multifocal aspheric corneal ablation profile using a mini-monovision approach and to evaluate if corneal multifocality was effective, and to report the relative benefits of this approach. PATIENTS AND METHODS: Bilateral femtosecond laser-assisted in situ keratomileusis using a multifocal aspheric corneal ablation profile was performed on 19 hyperopic patients (38 eyes). They were divided into two groups based on eye dominance: dominant eye (DE) group targeting emmetropia and the nondominant eye (NDE) group targeting -0.5 D slight myopia. The uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), and retreatment rates were reported from baseline to 6 months. RESULTS: The UNVA, UIVA, and UDVA improved significantly in both groups (Kruskal-Wallis test, DE and NDE: P<0.00001, P<0.000005, and P=0.00001, respectively). Corrected distance visual acuity (CDVA) baseline was better in both groups in comparison to UDVA at 6 months (Wilcoxon test, DE: P<0.001, 95% confidence interval (CI) of the median 0.0-0.0 LogMAR and 0.1000-0.1218 LogMAR and NDE: P=0.010, 95% CI of the median 0.0-0.0 LogMAR and 0.00-0.10 LogMAR). There was a significant loss of lines between CDVA baseline and UDVA at 6 months in both groups (DE group: 68% of eyes lost one line or more; NDE group: 58% of eyes lost one line or more). The corrected near visual acuity baseline compared to UNVA at 6 months was not statistically important (Wilcoxon test, DE: P=0.8125, 95% CI of the median 0.0-0.0 LogMAR and 0.0-0.0 LogMAR and NDE: P=0.82, 95% CI of the median 0.0-0.0 LogMAR and 0.0-0.0 LogMAR). The comparison among the UDVA, UIVA, and UNVA between the two groups at baseline and during all follow-ups was not statistically important. Two cases from the DE group were retreated (6%). CONCLUSION: Use of this multifocal aspheric corneal ablation profile in patients with hyperopic presbyopia significantly improved UDVA, UIVA, and UNVA. This improvement was due to created multifocality of the cornea. The mini-monovision seems not to affect UDVA, UIVA, and UNVA between the two groups. The retreatment rates at the 6-month evaluation were significantly less in our study when compared with other studies. This method seems to improve UDVA, UIVA, and UNVA but could result in a significant statistical difference between CDVA baseline and UDVA at 6 months that leads to loss of lines in distance vision. Despite promising results, this is a preliminary evaluation of this new profile, and a larger number of eyes are needed to verify visual outcomes, retreatment rates, and safety.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA