Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros








Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 19645, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37950034

RESUMO

Correlation Plenoptic Imaging (CPI) is a novel volumetric imaging technique that uses two sensors and the spatio-temporal correlations of light to detect both the spatial distribution and the direction of light. This novel approach to plenoptic imaging enables refocusing and 3D imaging with significant enhancement of both resolution and depth of field. However, CPI is generally slower than conventional approaches due to the need to acquire sufficient statistics for measuring correlations with an acceptable signal-to-noise ratio (SNR). We address this issue by implementing a Deep Learning application to improve image quality with undersampled frame statistics. We employ a set of experimental images reconstructed by a standard CPI architecture, at three different sampling ratios, and use it to feed a CNN model pre-trained through the transfer learning paradigm U-Net architecture with VGG-19 net for the encoding part. We find that our model reaches a Structural Similarity (SSIM) index value close to 1 both for the test sample (SSIM = [Formula: see text]) and in 5-fold cross validation (SSIM = [Formula: see text]); the results are also shown to outperform classic denoising methods, in particular for images with lower SNR. The proposed work represents the first application of Artificial Intelligence in the field of CPI and demonstrates its high potential: speeding-up the acquisition by a factor 20 over the fastest CPI so far demonstrated, enabling recording potentially 200 volumetric images per second. The presented results open the way to scanning-free real-time volumetric imaging at video rate, which is expected to achieve a substantial influence in various applications scenarios, from monitoring neuronal activity to machine vision and security.

2.
Sci Rep ; 13(1): 12813, 2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37550319

RESUMO

The correlation properties of light provide an outstanding tool to overcome the limitations of traditional imaging techniques. A relevant case is represented by correlation plenoptic imaging (CPI), a quantum-inspired volumetric imaging protocol employing spatio-temporally correlated photons from either entangled or chaotic sources to address the main limitations of conventional light-field imaging, namely, the poor spatial resolution and the reduced change of perspective for 3D imaging. However, the application potential of high-resolution imaging modalities relying on photon correlations is limited, in practice, by the need to collect a large number of frames. This creates a gap, unacceptable for many relevant tasks, between the time performance of correlated-light imaging and that of traditional imaging methods. In this article, we address this issue by exploiting the photon number correlations intrinsic in chaotic light, combined with a cutting-edge ultrafast sensor made of a large array of single-photon avalanche diodes (SPADs). This combination of source and sensor is embedded within a novel single-lens CPI scheme enabling to acquire 10 volumetric images per second. Our results place correlated-photon imaging at a competitive edge and prove its potential in practical applications.

3.
Polymers (Basel) ; 15(5)2023 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-36904413

RESUMO

Thin sheets of ultra-high molecular weight polyethylene (UHMWPE), both in pristine form and containing carbon nanotubes (CNTs) or Fe2O3 nanoparticles (NPs) at different concentrations, were prepared. The CNT and Fe2O3 NP weight percentages used ranged from 0.01% to 1%. The presence of CNTs and Fe2O3 NPs in UHMWPE was confirmed by transmission and scanning electron microscopy and by energy dispersive X-ray spectroscopy analysis (EDS). The effects of the embedded nanostructures on the UHMWPE samples were studied using attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy and UV-Vis absorption spectroscopy. The ATR-FTIR spectra show the characteristic features of the UHMWPE, CNTs, and Fe2O3. Concerning the optical properties, regardless of the type of embedded nanostructures, an increase in the optical absorption was observed. The allowed direct optical energy gap value was determined from the optical absorption spectra: in both cases, it decreases with increasing CNT or Fe2O3 NP concentrations. The obtained results will be presented and discussed.

4.
Sci Rep ; 12(1): 16823, 2022 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-36207387

RESUMO

Light-field microscopy represents a promising solution for microscopic volumetric imaging, thanks to its capability to encode information on multiple planes in a single acquisition. This is achieved through its peculiar simultaneous capture of information on light spatial distribution and propagation direction. However, state-of-the-art light-field microscopes suffer from a detrimental loss of spatial resolution compared to standard microscopes. In this article, we experimentally demonstrate the working principle of a new scheme, called Correlation Light-field Microscopy (CLM), where the correlation between two light beams is exploited to achieve volumetric imaging with a resolution that is only limited by diffraction. In CLM, a correlation image is obtained by measuring intensity correlations between a large number of pairs of ultra-short frames; each pair of frames is illuminated by the two correlated beams, and is exposed for a time comparable with the source coherence time. We experimentally show the capability of CLM to recover the information contained in out-of-focus planes within three-dimensional test targets and biomedical phantoms. In particular, we demonstrate the improvement of the depth of field enabled by CLM with respect to a conventional microscope characterized by the same resolution. Moreover, the multiple perspectives contained in a single correlation image enable reconstructing over 50 distinguishable transverse planes within a 1 mm3 sample.


Assuntos
Microscopia
5.
Sensors (Basel) ; 22(17)2022 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-36081124

RESUMO

Correlation plenoptic imaging (CPI) is a technique capable of acquiring the light field emerging from a scene of interest, namely, the combined information of intensity and propagation direction of light. This is achieved by evaluating correlations between the photon numbers measured by two high-resolution detectors. Volumetric information about the object of interest is decoded, through data analysis, from the measured four-dimensional correlation function. In this paper, we investigate the relevant aspects of the refocusing algorithm, a post-processing method that isolates the image of a selected transverse plane within the 3D scene, once applied to the correlation function. In particular, we aim at bridging the gap between existing literature, which only deals with refocusing algorithms in case of continuous coordinates, and the experimental reality, in which the correlation function is available as a discrete quantity defined on the sensors pixels.

6.
Sensors (Basel) ; 22(7)2022 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-35408392

RESUMO

Diffraction-limited light-field imaging has been recently achieved by exploiting light spatial correlations measured on two high-resolution detectors. As in conventional light-field imaging, the typical operations of refocusing and 3D reconstruction are based on ray tracing in a geometrical optics context, and are thus well defined in the ideal case, both conceptually and theoretically. However, some properties of the measured correlation function are influenced by experimental features such as the finite size of apertures, detectors, and pixels. In this work, we take into account realistic experimental conditions and analyze the resulting correlation function through theory and simulation. We also provide an expression to evaluate the pixel-limited resolution of the refocused images, as well as a strategy for eliminating artifacts introduced by the finite size of the optical elements.

7.
Opt Express ; 28(24): 35857-35868, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33379693

RESUMO

We propose a novel method to perform plenoptic imaging at the diffraction limit by measuring second-order correlations of light between two reference planes, arbitrarily chosen, within the tridimensional scene of interest. We show that for both chaotic light and entangled-photon illumination, the protocol enables to change the focused planes, in post-processing, and to achieve an unprecedented combination of image resolution and depth of field. In particular, the depth of field results larger by a factor 3 with respect to previous correlation plenoptic imaging protocols, and by an order of magnitude with respect to standard imaging, while the resolution is kept at the diffraction limit. The results lead the way towards the development of compact designs for correlation plenoptic imaging devices based on chaotic light, as well as high-SNR plenoptic imaging devices based on entangled photon illumination, thus contributing to make correlation plenoptic imaging effectively competitive with commercial plenoptic devices.

8.
Phys Rev Lett ; 119(24): 243602, 2017 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-29286709

RESUMO

Traditional optical imaging faces an unavoidable trade-off between resolution and depth of field (DOF). To increase resolution, high numerical apertures (NAs) are needed, but the associated large angular uncertainty results in a limited range of depths that can be put in sharp focus. Plenoptic imaging was introduced a few years ago to remedy this trade-off. To this aim, plenoptic imaging reconstructs the path of light rays from the lens to the sensor. However, the improvement offered by standard plenoptic imaging is practical and not fundamental: The increased DOF leads to a proportional reduction of the resolution well above the diffraction limit imposed by the lens NA. In this Letter, we demonstrate that correlation measurements enable pushing plenoptic imaging to its fundamental limits of both resolution and DOF. Namely, we demonstrate maintaining the imaging resolution at the diffraction limit while increasing the depth of field by a factor of 7. Our results represent the theoretical and experimental basis for the effective development of promising applications of plenoptic imaging.

9.
Sci Rep ; 7(1): 2247, 2017 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-28533523

RESUMO

We present the experimental characterization of two distant double-slit masks illuminated by chaotic light, in the absence of first-order imaging and interference. The scheme exploits second-order interference of light propagating through two indistinguishable pairs of disjoint optical paths passing through the masks of interest. The proposed technique leads to a deeper understanding of biphoton interference and coherence, and opens the way to the development of novel schemes for retrieving information on the relative position and the spatial structure of distant objects, which is of interest in remote sensing, biomedical imaging, as well as monitoring of laser ablation, when first-order imaging and interference are not feasible.

10.
Opt Express ; 25(6): 6589-6603, 2017 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-28381006

RESUMO

We demonstrate a novel second-order spatial interference effect between two indistinguishable pairs of disjoint optical paths from a single chaotic source. Beside providing a deeper understanding of the physics of multi-photon interference and coherence, the effect enables retrieving information on both the spatial structure and the relative position of two distant double-pinhole masks, in the absence of first order coherence. We also demonstrate the exploitation of the phenomenon for simulating quantum logic gates, including a controlled-NOT gate operation.

11.
Phys Rev Lett ; 116(22): 223602, 2016 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-27314718

RESUMO

Plenoptic imaging is a promising optical modality that simultaneously captures the location and the propagation direction of light in order to enable three-dimensional imaging in a single shot. However, in standard plenoptic imaging systems, the maximum spatial and angular resolutions are fundamentally linked; thereby, the maximum achievable depth of field is inversely proportional to the spatial resolution. We propose to take advantage of the second-order correlation properties of light to overcome this fundamental limitation. In this Letter, we demonstrate that the correlation in both momentum and position of chaotic light leads to the enhanced refocusing power of correlation plenoptic imaging with respect to standard plenoptic imaging.

12.
Phys Rev Lett ; 96(2): 020502, 2006 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-16486554

RESUMO

We propose and experimentally verify a novel method for the remote preparation of entangled bits (ebits) made of a single photon coherently delocalized in two well-separated temporal modes. The proposed scheme represents a remotely tunable source for tailoring arbitrary ebits, whether maximally or nonmaximally entangled, which is highly desirable for applications in quantum information technology. The remotely prepared ebit is studied by performing homodyne tomography with an ultrafast balanced homodyne detection scheme recently developed in our laboratory.

13.
Phys Rev Lett ; 94(6): 063601, 2005 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-15783729

RESUMO

We report the first experimental demonstration of two-photon imaging with a pseudothermal source. Similarly to the case of entangled states, a two-photon Gaussian thin lens equation is observed, indicating EPR type correlation in position. We introduce the concepts of two-photon coherent and two-photon incoherent imaging. The differences between the entangled and the thermal cases are explained in terms of these concepts.

14.
Phys Rev Lett ; 92(23): 233601, 2004 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-15245156

RESUMO

We report a quantum interference and imaging experiment which allows identifying the entanglement in momentum and position variables of a two-photon system. The measurements show indeed that the uncertainties in the sum of momenta and in the difference of positions of the entangled two-photon satisfy both EPR inequalities Delta(k(1)+k(2))

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA