Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 101(5): 837-846, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36841947

RESUMO

OBJECTIVES: To identify a simple echocardiographic predictor of procedural success to select patient for percutaneous suture-mediated patent fossa ovalis (PFO) closure. BACKGROUND: Percutaneous suture-mediated PFO closure has been shown as a safe and advantageous alternative to device-based PFO closure, yet its overall success is slightly lower in unselected patients. METHODS: Preprocedural transesophageal echocardiogram (TEE) of 302 patients (113 men, 45 ± 12 years) who underwent percutaneous suture-mediated PFO closure were reviewed. RESULTS: At echocardiographic follow-up (3-6 months), residual right-to-left shunt (RLS) ≥2 was found in 60 (19.9%) patients. At multivariable analysis, only two anatomical variables measured at preprocedural TEE were found as independent predictors of residual RLS ≥ 2 at follow-up: PFO maximum width (odds ratio [OR] 1.89, 95% confidence interval [CI] 1.16-3.40, p = 0.02) and PFO minimal septa overlapping (OR 0.58, 95% CI 0.35-0.88, p = 0.02). An index based on the ratio of PFO maximum width to PFO minimum septal overlapping (W/SO) proved to be the most powerful predictor of RLS ≥ 2 at follow-up (OR 48.1, 95% CI 9.3-352.2, p < 0.01). The ROC curve for the W/SO ratio was found to have an AUC of 0.84 (95% CI 0.75-0.93) and a cut-off value of 0.61 yielding a sensitivity of 80% and specificity of 78% with a negative predictive value of 94%. A decision tree methodology's AUC was 0.75 (95% CI 0.67-0.83). CONCLUSIONS: The results of this study indicate that the ratio between the maximum amplitude of the PFO and the minimum overlap of the septa is the best predictive index of a favorable result by using one stitch only.


Assuntos
Forame Oval Patente , Masculino , Humanos , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Resultado do Tratamento , Ecocardiografia , Ecocardiografia Transesofagiana , Suturas , Cateterismo Cardíaco/efeitos adversos
2.
Minerva Cardiol Angiol ; 71(1): 83-90, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34713674

RESUMO

BACKGROUND: Atrial fibrillation is an undesirable event following percutaneous patent fossa ovalis (PFO) closure with metallic occluders, suggesting that implanting a rigid closure device could alter atrial function. Suture-mediated PFO closure is a new technique, achieving closure of the PFO by means of a simple suture. Aim of this study was to evaluate left atrial function after closure of PFO by direct suture and traditional occluders. METHODS: We studied 40 age and sex homogeneous patients, 20 undergoing PFO closure by device (OCL) and 20 by suturing (NS). Twenty healthy sex-age matched subjects made up the control group (CT). Left atrial function was evaluated by using volumetric and speckle-tracking analysis assessing the following parameters: total emptying fraction (EF), Expansion Index (EI), active emptying fraction (AEF), strain values of the reservoir (r-ED), conduit (cd-ED) and contraction phase (ct-ED). RESULTS: Compared to CT and NS, OCL patients had significantly worst indices of left atrial reservoir function (EF P=0.001, EI P=0.003, r-ED P<0.001), conduit function (cd-ED P=0.018) and contraction function (AEF P=0.010; ct-ED P<0.001). No significant differences were observed in left atrial function indices between CT and NS patients. CONCLUSIONS: Suture-mediated PFO closure does not alter left atrial function. Conversely, metallic occluder is associated with worse left atrium function. This detrimental effect on atrial function could favor the development of atrial arrhythmias.


Assuntos
Fibrilação Atrial , Septo Interatrial , Forame Oval Patente , Humanos , Forame Oval Patente/cirurgia , Forame Oval Patente/complicações , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Próteses e Implantes
3.
Minerva Cardiol Angiol ; 71(2): 169-174, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34137243

RESUMO

BACKGROUND: Percutaneous suture-mediated patent foramen ovale (PFO) closure has been recently introduced in clinical practice showing a favorable efficacy and safety profile in most PFO cases. The aim of this study was to assess the long-term outcomes of PFO closure by direct suture in a large consecutive series of patients. METHODS: We extracted all consecutive patients who underwent percutaneous closure of the PFO by suture technique (HeartStitch, Fountain Valley, CA, USA) from June 2016 with a follow-up of at least 2 years. After PFO closure, patients were followed-up clinically at 1, 6 and up to 12 months and microbubble transthoracic echocardiography (TTE) scheduled between 3 and 6 months, and at 12-month follow-up. After 12 months, patients were clinically checked every 6 months. RESULTS: As of September 1, 2020, 187 patients had undergone PFO closure with suture for at least two years and, of these, 181 (121 women and 60 men, mean age 45±13 years, range 15-75 years) had complete clinical and instrumental follow-up (97%). There were no peri-procedural complications. Mean follow-up was 1076±251 days (range 727-1574). At 12-month TTE, a significant residual atrial shunt was found in 39 patients (21%). At follow-up no recurrent thromboembolic or cerebral event occurred, no instrumental evidence of suture dehiscence detected and, 18 months after the procedure, one patient had an episode of transient atrial fibrillation lasting less than 24 hours and resolved spontaneously. CONCLUSIONS: Long-term follow-up data indicate that PFO closure by direct suturing is safe and effective. Two years after the procedure, there were no significant complications, no permanent arrhythmic complications and evidence of suture dehiscence.


Assuntos
Forame Oval Patente , Masculino , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/cirurgia , Forame Oval Patente/complicações , Seguimentos , Resultado do Tratamento , Ecocardiografia , Suturas
4.
JACC Cardiovasc Interv ; 13(18): 2112-2120, 2020 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-32972572

RESUMO

OBJECTIVES: This study sought to assess patent fossa ovalis (PFO) anatomy by transesophageal echocardiography (TEE) in patients undergoing percutaneous suture-mediated PFO closure to identify predictors of post-procedural residual atrial right-to-left shunt (RLS). BACKGROUND: Percutaneous suture-mediated PFO closure has been proven to be a safe and effective technique in most PFO patients. METHODS: From June 2016 to October 2019, 247 consecutive patients underwent percutaneous suture-mediated PFO closure at our institution. Of them, 230 (46 ± 13 years of age, 146 women) had complete and technically evaluable pre-procedural TEE. The following parameters in short-axis view were assessed: presence and grade of spontaneous RLS, PFO length and width, presence of atrial septal aneurysm and its maximal bulge, and presence of an embryonic or fetal remnant (Chiari network or Eustachian valve). RESULTS: At the first follow-up transthoracic echocardiography performed between 3 and 6 months from the closure procedure, a residual RLS ≥2 grade was found in 37 (16%) patients. Grade of pre-procedural spontaneous RLS (hazard ratio: 1.99; 95% confidence interval: 1.14 to 3.48; p = 0.016) shunt and PFO width (hazard ratio: 2.52; 95% confidence interval: 1.85 to 3.43; p < 0.001) were both found to be significantly associated with significant residual RLS at multivariable analysis. The presence of atrial septal aneurysm and its maximal bulge and of congenital remnants was not associated with significant residual RLS. CONCLUSIONS: Percutaneous suture-mediated PFO closure is feasible in the majority of septal anatomies; however, PFO >5 mm in width and spontaneous large RLS are less likely to be closed with 1 stitch only.


Assuntos
Forame Oval Patente , Aneurisma Cardíaco , Adulto , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Suturas , Resultado do Tratamento
5.
EuroIntervention ; 14(3): e272-e279, 2018 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-29616629

RESUMO

AIMS: The aim of this study was to assess the efficacy of a novel percutaneous "deviceless" suture-mediated patent foramen ovale (PFO) closure system. METHODS AND RESULTS: Between June 2016 and October 2017, a prospective registry aimed at assessing the safety and efficacy of the NobleStitch EL (HeartStitch, Fountain Valley, CA, USA) suture-based PFO closure system was carried out at 12 sites in Italy. Among 200 consecutive patients evaluated, 192 were considered suitable for suture-mediated PFO closure (44±13 years, 114 female). Suture of the septum with the NobleStitch EL system was carried out successfully in 186 (96%) patients. Median fluoroscopy time was 16.1 (13.0-22.5) minutes and contrast volume 200 (150-270) ml. At 206±130 days follow-up, contrast transthoracic echocardiography with the Valsalva manoeuvre revealed no RLS (grade 0) in 139 (75%) patients and RLS grade ≤1 in 166 (89%) patients. Significant RLS was present in 20 (11%) patients (grade 2 and 3 in 11 and nine patients, respectively). There were no device-related complications. CONCLUSIONS: The early results of this first Italian registry indicate that the suture-mediated "deviceless" closure of PFO is feasible in the majority of septal anatomies, and provides an effective closure of PFO comparable to traditional devices with a good safety profile at medium-term follow-up.


Assuntos
Forame Oval Patente , Dispositivo para Oclusão Septal , Adulto , Cateterismo Cardíaco , Feminino , Seguimentos , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Suturas , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA