RESUMO
Boldenone (Bo), androsta-1,4-dien-17ß-ol-3-one, is an anabolic androgenic steroid not clinically approved for human application. Despite this, many cases are reported every year of athletes testing positive for Bo or its main metabolite 5ß-androst-1-en-17ß-ol-3-one (BoM). Recently the capability of different human intestinal bacteria to produce enzymes able to modify endogenous steroids in Bo has been demonstrated. When a urinary concentration of Bo and/or BoM between 5 and 30 ng/mL is measured a complementary analysis by gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) must be carried out to discriminate the endogenous or exogenous origin. In the present work, a novel analytical method that couples LC-GC by means of the TOTAD interface with C-IRMS is described. The method is based on a first RPLC separation of unacetyled steroids, followed by acetylation and automated on-line LC-GC-C-IRMS, which includes a second RPLC clean-up of acetyl Bo and BoM, isolation of the two fractions in a fraction collector and their consecutive analysis by GC-C-IRMS. The method has been applied to the analysis of urine samples fortified at 5 and 10 ng/mL, where it has shown a good performance.
Assuntos
Anabolizantes/urina , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Testosterona/análogos & derivados , Isótopos de Carbono/análise , Dopagem Esportivo , Humanos , Detecção do Abuso de Substâncias/métodos , Testosterona/urinaRESUMO
A screening method for the detection of artificial colours (naphthol yellow, tartrazine, quinoline yellow, Sunset yellow, Allura red, amaranth, azorubine, Ponceau 4R and Red 2G) in saffron is described. The method involves removal of crocins by precipitation of crocetin (pH 0.1, 90 degrees C) before adsorption of the artificial colours on polyamide SPE cartridges (pH 2). After washing with methanol, acetone and methanol, elution was done with a methanol:ammonia solution (95:5 v/v), and detection was performed by derivative spectrometry. Sample pretreatment changes the UV-Vis saffron extract profile in such a way that second derivative spectra can be used to identify the presence of added colours. Erythrosine, which was found to be pH dependent, could not be detected under the above conditions. The lowest detectable amount for each colour was strongly dependent on chemical structure. The recovery of carminic acid was very low possibly due to irreversible retention on the polyamide. This procedure can replace the current ISO TLC method (2003) and be used alternatively or in combination with HPLC procedures adopted in the same standard.