Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Acta Ortop Bras ; 31(4): e266635, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37547237

RESUMO

Currently, the market offers a wide variety of suture threads, made of materials with different structural and chemical properties. Among many other characteristics, they vary in origin, absorption or degradation, and structure. From this variety, the clinical doubt arises as to which material provides the patient with the best healing quality. Objective: This study aims to comparatively evaluate two different types of suture threads-Monocryl® (polyglycaprone 25) and Ethilon® (nylon)-regarding their ability to aid in tissue regeneration by a histological and immunohistochemical analysis of the skin of rats sutured with the aforementioned materials. Methods: This basic experimental study used 12 adult Wistar rats, randomly divided into three groups with four animals each and subjected to four longitudinal incisions under anesthesia. Each group corresponded to a postsurgical evaluation date (one, seven, and 14 days). Results: At 14 postoperative days, the studied groups had no histological difference. However, the use of nylon thread showed greater evidence of earlier fibrotic union. Conclusion: This study found no histological difference in healing 14 days after surgery among the techniques and the types of suture threads. Level of Evidence II, Therapeutic Studies.


Atualmente, encontra-se disponível no mercado uma grande variedade de fios de sutura, compostos de materiais com diferentes propriedades estruturais e químicas, que variam quanto à origem, absorção ou degradação e estrutura, entre outras características. A partir dessa disponibilidade, emerge a dúvida clínica quanto ao material que propicia a melhor qualidade de cicatrização ao paciente. Objetivo: Avaliar comparativamente dois tipos de fios - Monocryl® (poliglicaprone 25) e Ethilon® (nylon) - quanto à sua capacidade de auxílio na regeneração tecidual, por meio da análise histológica e imuno-histoquímica da pele de ratos submetidos a suturas com esses materiais. Métodos: Neste estudo básico experimental, foram utilizados 12 ratos adultos da linhagem Wistar, randomicamente divididos em três grupos com quatros animais cada, que foram submetidos a quatro incisões longitudinais sob anestesia. Cada grupo correspondeu a uma data de avaliação pós-cirúrgica (1, 7 e 14 dias). Resultados: Passados 14 dias após a operação, não houve diferença histológica em relação aos grupos estudados. No entanto, o uso de fio de nylon apresentou evidência de união fibrótica mais precoce. Conclusão: Não há diferença histológica de cicatrização após 14 dias pós-operatórios entre as técnicas e os tipos de fio de sutura. Nível de Evidência II, Estudos Terapêuticos.

2.
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1451189

RESUMO

INTRODUCTION Menopausal women have an increase deposition of body fat and changes in the lipid profile, being especially susceptible to cardiovascular diseases, and type 2 diabetes. However, physical activity can mitigate this situation. Thus, the aim of the present study is to evaluate the effects of moderate aerobic exercise on visceral adipose tissue (VAT) of female LDL-receptor knockout ovariectomized mice. METHODS We used 48 animals, divided into six groups (n » 8/per group): sedentary control (SC), sedentary ovariectomized control (SCO), trained ovariectomized control (TCO), sedentary non-ovariectomized LDL-receptor knockout (KS), sedentary ovariectomized LDL-receptor knockout (KOS), and trained LDL-receptor knockout ovariectomized (KOT). We analyzed the VAT through morphometric and stereological parameters in hematoxylin and eosin stained sections. Additionally, we evaluated biochemical parameters as glucose, triglycerides, and total cholesterol. Finally, immunohistochemical techniques for matrix remodeling, inflammation, apoptosis, and oxidative stress were evaluated. RESULTS We observed thatmenopause is related to increased visceral adiposity, inflammation, oxidative stress, macrophages activity, serum levels of glucose, triglycerides, and total cholesterol. However, exercise was effective in reducing these parameters, as well as being associated with increased vascularization of VAT and interstitial volume density. CONCLUSIONS Moderate exercise is a key factor in mitigating the effects of dyslipidemia in estrogen deprivation. However, further studies are needed to corroborate with our findings.


Assuntos
Menopausa
3.
Acta ortop. bras ; 31(4): e266635, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1447094

RESUMO

ABSTRACT Currently, the market offers a wide variety of suture threads, made of materials with different structural and chemical properties. Among many other characteristics, they vary in origin, absorption or degradation, and structure. From this variety, the clinical doubt arises as to which material provides the patient with the best healing quality. Objective: This study aims to comparatively evaluate two different types of suture threads-Monocryl® (polyglycaprone 25) and Ethilon® (nylon)-regarding their ability to aid in tissue regeneration by a histological and immunohistochemical analysis of the skin of rats sutured with the aforementioned materials. Methods: This basic experimental study used 12 adult Wistar rats, randomly divided into three groups with four animals each and subjected to four longitudinal incisions under anesthesia. Each group corresponded to a postsurgical evaluation date (one, seven, and 14 days). Results: At 14 postoperative days, the studied groups had no histological difference. However, the use of nylon thread showed greater evidence of earlier fibrotic union. Conclusion: This study found no histological difference in healing 14 days after surgery among the techniques and the types of suture threads. Level of Evidence II, Therapeutic Studies.


RESUMO Atualmente, encontra-se disponível no mercado uma grande variedade de fios de sutura, compostos de materiais com diferentes propriedades estruturais e químicas, que variam quanto à origem, absorção ou degradação e estrutura, entre outras características. A partir dessa disponibilidade, emerge a dúvida clínica quanto ao material que propicia a melhor qualidade de cicatrização ao paciente. Objetivo: Avaliar comparativamente dois tipos de fios - Monocryl ® (poliglicaprone 25) e Ethilon ® (nylon) - quanto à sua capacidade de auxílio na regeneração tecidual, por meio da análise histológica e imuno-histoquímica da pele de ratos submetidos a suturas com esses materiais. Métodos: Neste estudo básico experimental, foram utilizados 12 ratos adultos da linhagem Wistar, randomicamente divididos em três grupos com quatros animais cada, que foram submetidos a quatro incisões longitudinais sob anestesia. Cada grupo correspondeu a uma data de avaliação pós-cirúrgica (1, 7 e 14 dias). Resultados: Passados 14 dias após a operação, não houve diferença histológica em relação aos grupos estudados. No entanto, o uso de fio de nylon apresentou evidência de união fibrótica mais precoce. Conclusão: Não há diferença histológica de cicatrização após 14 dias pós-operatórios entre as técnicas e os tipos de fio de sutura. Nível de Evidência II, Estudos Terapêuticos.

4.
J Mater Sci Mater Med ; 25(5): 1301-5, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24449027

RESUMO

The use of metal devices in medical application is increasing but it remains incompletely understood the physiological effects of component degradation. Niobium (Nb) alloys have already been investigated in the 1980's and recent studies demonstrated the potential of Nb as an implant material. The purpose of this study was to determine cytotoxic, hematologic and histologic effects of niobium in Swiss mice. Animals were treated with a single dose of 3 % niobium oxide (Nb2O5) diluted in PBS, i.p. Cytotoxic assay, hematologic and histologic evaluation were done 3, 7 and 12 days after niobium treatment. Data have shown increased number of cells after niobium treatment, but there was no difference in cell viability. Furthermore, it was not observed hematological modification 3, 7 or 12 days after niobium treatment. Despite the fact that animals treated with niobium for 3 and 7 days showed mild degeneration in hepatocytes, mice kept alive for 12 days showed liver cells regeneration. Our results suggested that niobium cytotoxicity was not progressive because 12 days after treatment there was an evident liver regeneration. Data obtained indicated that niobium may be promising alternatives to biomedical applications.


Assuntos
Materiais Biocompatíveis/toxicidade , Células Sanguíneas/efeitos dos fármacos , Células Sanguíneas/patologia , Doença Hepática Induzida por Substâncias e Drogas/etiologia , Doença Hepática Induzida por Substâncias e Drogas/patologia , Nióbio/toxicidade , Óxidos/toxicidade , Animais , Apoptose/efeitos dos fármacos , Relação Dose-Resposta a Droga , Masculino , Camundongos , Nióbio/administração & dosagem , Óxidos/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA