Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
JSES Int ; 8(5): 1010-1015, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39280168

RESUMO

Background: Rotator cuff repair is one of the most frequently performed procedures in orthopedic surgery. However, considering the limited healing potential of rotator cuff tendons, several augmentation strategies have evolved to enhance tendon healing. The purpose of this article was to present a new surgical technique called Bio-Ravioli. Methods: Patients with repairable full-thickness posterosuperior rotator cuff tear and a moderate-to-high risk of healing failure were chosen as candidates for the Bio-Ravioli procedure. It is a biologic augmentation strategy to increase healing potential of arthroscopic rotator cuff repair by use of a biologic graft fixed at the bone-tendon interface. The Bio-Ravioli consists of microfragmented autologous subacromial bursal tissue enveloped in a patch of compressed autologous long head of biceps tendon tissue. The rotator cuff is then repaired to the bone and over the graft using a transosseus equivalent configuration. Conclusion: The Bio-Ravioli technique represents an easy and reliable way to increase the healing potential at the bone-tendon interface by using autologous mesenchymal stem cells from different sources: subacromial bursa and long head of the biceps tendon.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38071641

RESUMO

INTRODUCTION: This study was aimed to assess the return to sport (RTS) rate in patients who underwent CT-based robotic-assisted unicompartmental knee arthroplasty (RA-UKA) and to evaluate the clinical performance and the assocition between patients' sport activity levels and Patient Reported Outcome Measures after surgery. MATERIALS AND METHODS: This retrospective study included 218 patients undergoing medial RA-UKA with fixed-bearing implants, performed at a single center between 2014 and 2019. Patients were allocated into two groups based on sport's practice and were administered the University of California, Los Angeles (UCLA) activity scale, Forgotten Joint Score-12 (FJS-12), Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS-JR) and the 5-Level Likert Scale. RESULTS: A total of 136 patients were included for assessment. The overall RTS rate after surgery was 93.1%. Six subjects who did not practice sport preoperatively, were able to start sport activities after surgery and all patients performing sports preoperatively, returned to same activity level. The mean UCLA and FJS-12 scores in the group of patients practicing sports were significantly higher than in the no-sport group (p < 0.001 and p < 0.05, respectively). Patients who practiced sports were more likely to attain higher FJS-12 and UCLA scores than those who were not performing physical activity. CONCLUSIONS: Patients undergoing RA-UKA showed a 93.1% RTS rate after surgery. Differences were detected in terms of postoperative UCLA and FJS-12 scores between patients who performed and who did not practice sport activities after surgery. High levels of postoperative UCLA scores were associated with higher KOOS-JR and patients' satisfaction.

3.
Acta Biomed ; 94(S1): e2023134, 2023 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-37272625

RESUMO

In cruciate-retaining (CR) total knee arthroplasty (TKA) the preservation of the posterior cruciate ligament (PCL) provides joint stability and drives knee kinematics. No previous studies described in-vivo knee kinematics of PCL-deficient CR TKA. In the present case report it's described the in-vivo kinematic pattern change in a patient with post-operative PCL failure before and after insert replacement to a cruciate substituting (CS) design. In-vivo fluoroscopic analysis showed that PCL-deficient TKA showed more anterior translation of the lateral femoral condyle with respect to a cohort  of patients operated of CR-TKA with intact PCL, undergoing fluoroscopic analysis. The replacement to a CS design provided more external rotation of the femoral component and less anterior motion of the lateral condyle. The antero-posterior translation of the medial condyle was similar in PCL-deficient knee, CS TKA and controls. TKA with PCL deficiency showed more antero-posterior motion compared to TKAs with intact PCL and this can be source the of instability and a potential factor for patient's dissatisfaction. For this reason surgeons should attentively verify PCL integrity when performing a cruciate-sparing TKA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Ligamento Cruzado Posterior , Humanos , Ligamento Cruzado Posterior/cirurgia , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia
4.
Int Orthop ; 47(3): 711-717, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36648533

RESUMO

PURPOSE: To compare the clinical outcomes of subjects undergoing primary robotic-assisted total knee arthroplasty (RA-TKA), following functional alignment (FA) principles, with cruciate-retaining (CR) or posterior-stabilized (PS) bearing designs, at a minimum of 24 months of follow-up. METHODS: This observational, retrospective study included 167 consecutive patients undergoing RA-TKA with cemented PS and cementless CR implants performed with a CT-base robotic-arm assisted system (Mako, Stryker), following FA principles, between 2017 and 2020. Patients were followed up with a clinical and radiographic assessment and were administered the Forgotten Joint Score-12 (FJS-12), Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS-JR), and the 5-level Likert scale (5-LLS). RESULTS: Three TKA revisions were performed (2 PS, 1 CR); therefore, a total of 164 knees with a mean age of 71.7 years (SD 8.9) were considered (80 cemented PS; 84 cementless CR). No statistically significant differences were recorded between study groups relative to FJS-12, KOOS-JR, and 5-LLS at a minimum of two year follow-up (FJS-12 89.3 ± 9.2 vs 87.5 ± 12.8, p-value 0.46; KOOS-JR 88.8 ± 10.0 vs 86.7 ± 14.0, p-value 0.31; 5-LLS 4.5 ± 0.7 vs 4.5 ± 0.8, p-value 0.34). CONCLUSION: No significant outcome differences were reported between patients undergoing PS and CR RA-TKA at a minimum of two year follow-up. RA-TKA achieves excellent clinical results and high satisfaction scores, regardless of the implant design used.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Idoso , Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Amplitude de Movimento Articular , Osteoartrite do Joelho/cirurgia
5.
J Arthroplasty ; 36(11): 3650-3655, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34294481

RESUMO

BACKGROUND: This retrospective observational study was designed to investigate the association between radiographic Ahlbäck osteoarthritis (OA) grade and postoperative joint perception in a cohort of patients undergoing medial robotic arm-assisted unicompartmental knee arthroplasty (RA-UKA), using the Forgotten Joint Status and Patient Acceptable Symptom State (PASS) as outcomes. METHODS: Between January 2014 and May 2019, 660 patients (719 knees) underwent medial RA-UKA at 2 centers. Ahlbäck OA grade was measured on preoperative knee radiographs. Postoperatively, patients were administered the Forgotten Joint Score-12 (FJS-12) and 5-level Likert scale to assess patients' satisfaction. Correlations were described among FJS-12, satisfaction, and Ahlbäck OA grade by means of logistic regression models. RESULTS: A total of 547 patients (602 knees) were assessed at a mean follow-up of 3.5 years (standard deviation 1.4). A total of 293 cases were graded as Ahlbäck 1 (Group A) and 309 knees were graded as Ahlbäck>1 (Group B). Statistically significant difference was detected in mean FJS-12 (P < .001), but not in the postoperative satisfaction level (P = .06) between the 2 groups. Patients in Group B had a significantly higher probability of attaining a "forgotten knee" after the operation, compared to Group A (P < .05). Cases in Group A had a significantly lower probability of achieving the PASS (P < .01). CONCLUSION: Patients with higher grades of OA (Ahlbäck>1) were more likely to attain a "forgotten knee," while patients with less severe OA (Ahlbäck 1) were less likely to achieve the PASS after RA-UKA. Although patients with less severe OA reported fairly good outcome, cases in which the results will be poorer are currently difficult to predict.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Artroplastia do Joelho/efeitos adversos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Resultado do Tratamento
6.
Knee Surg Sports Traumatol Arthrosc ; 29(10): 3316-3322, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32737526

RESUMO

PURPOSE: Robotic arm-assisted unicompartmental knee arthroplasty (RA-UKA) has been shown to improve component placement, reduce intraoperative variability, increase patient satisfaction and improve short-term survivorship results. The aim of this retrospective study was to determine the incidence of revision and the clinical performance at a minimum of 5-year follow-up for a cohort of patients who received a medial RA-UKA. METHODS: Between April 2011 and July 2013, a total of 254 patients underwent medial RA-UKA at a single centre. Clinical performance was investigated using the Forgotten Joint Score-12 (FJS-12) and a 5-level Likert scale made of five items to assess joint perception and patient satisfaction. Kaplan-Meier implant survivorship was calculated and reasons for revision were collected. The effect of age, gender and body mass index (BMI) on the probability of reporting high FJS-12 and satisfaction were assessed. RESULTS: After considering exclusion criteria and loss to follow-up, a total of 216 patients (224 medial RA-UKAs) were assessed at a mean 5.9 years of follow-up. Five RA-UKAs underwent implant revision, resulting in an overall Kaplan-Meier survivorship of 97.8%. Unexplained knee pain (0.9%) was the most common reason for RA-UKA revision. Good-to-excellent FJS-12 scores and high satisfaction levels were reported at mid-term follow-up. Male patients had higher probability of having FJS-12 > 90 (p < 0.05) and high satisfaction levels (p < 0.05). CONCLUSIONS: RA-UKAs demonstrated high survivorship and good-to-excellent patient-reported outcome measures and satisfaction levels at minimum 5-year follow-up. Results for male patients had improved clinical performance when compared to female subjects. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Feminino , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Masculino , Osteoartrite do Joelho/cirurgia , Reoperação , Estudos Retrospectivos , Sobrevivência , Resultado do Tratamento
7.
Knee Surg Sports Traumatol Arthrosc ; 29(3): 966-974, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32415361

RESUMO

PURPOSE: To investigate the femoral component alignment in patients undergoing soft tissue-guided, navigated total knee arthroplasty (TKA). It was hypothesized that with a mechanically aligned tibial component, the soft tissues tensioned and symmetric medial and lateral gaps in flexion/extension, the femoral component would be aligned to the preoperative distal femoral joint line, as measured on knee radiographs. METHODS: Between 2015 and 2017, 77 patients (78 knees) underwent navigated soft tissue-guided TKA at a single centre. Pre and postoperative radiographs were collected and varus knees were taken into account. The tibial cut was performed with navigation in neutral alignment. The femoral cuts were adjusted based on tensioned soft tissues, aiming for equal medial and lateral gaps in flexion and extension. The Knee Injury and Osteoarthritis Outcome Score (KOOS) and Knee Society Score (KSS) were collected pre and postoperatively as a secondary outcome measure. RESULTS: A total of 58 TKAs on varus knees were assessed. On average, the femoral component was placed at 1.7° (SD 1.7) varus in the coronal plane. The comparison between the radiographic native distal femoral alignment and the orientation of the femoral component coronal cut demonstrated a statistically significant (p < 0.0001), linear inverse relationship (r = 0.5). Satisfactory knee function and excellent pain remission were demonstrated by KOOS and KSS scores at a mean of 2.8 years (SD 0.5) follow-up. One TKA was revised, resulting in a 98.3% survivorship at three years. CONCLUSION: The proposed soft tissue-guided, navigated technique, aiming to preserve the integrity of the ligaments and a neutrally aligned tibial cut, provided a joint line respecting femoral coronal cut and encouraging short-term clinical results. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho/métodos , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Feminino , Fêmur/diagnóstico por imagem , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/fisiopatologia , Osteoartrite do Joelho/cirurgia , Radiografia , Amplitude de Movimento Articular , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA