Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
EuroIntervention ; 19(7): 580-588, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37565470

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in non-calcified aortic regurgitation (NCAR) is an off-label procedure. The balloon-expandable Myval includes extra-large sizes (30.5 mm and 32 mm) of interest in this setting. AIMS: We aimed to evaluate the safety and feasibility of Myval in NCAR. METHODS: This was an international, multicentre, observational study that enrolled all consecutive patients with symptomatic severe NCAR undergoing TAVR with the Myval device. The images were centrally analysed. RESULTS: A total of 113 patients were recruited, 64.6% were men, the mean age was 78.4±7.5 years, and the Society of Thoracic Surgeons score was 2.7±1.7%. Aortic root dilatation was present in 59.3% of patients, 7.1% were bicuspid, and the mean annular area was 638.6±106.0 mm2. The annular area was beyond the recommended range for extra-large sizes in 2.6% of cases, and additional volume was added in 92% (median 4 cc, up to 9 cc). The extra-large sizes were used in 95 patients (84.1%), and the mean oversizing was 17.9±11.0%. The technical success rate was 94.7%; the rate of residual ≥moderate aortic regurgitation was 8.9%, and the pacemaker rate was 22.2%. There were no cases of annular rupture, cardiac tamponade, or aortic dissection, but in 4 patients (3.5%) valve embolisation occurred (1 antegrade and 3 ventricular), all in cases with a tapered left ventricle outflow tract (p=0.007). Thirty-day and 1-year mortality were 5.3% and 9.7%, respectively. Technical success was associated with better survival (97.1% vs 72.7%; p=0.012), and valve embolisation was the main determinant of mortality (p=0.047). CONCLUSIONS: Myval is a feasible and safe option for selected non-operable patients with NCAR and demonstrated good midterm outcomes and lack of impact of oversizing on device durability.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese
2.
Circ Cardiovasc Interv ; 11(11): e006927, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30571207

RESUMO

BACKGROUND: The impact of preexisting left bundle branch block (LBBB) in transcatheter aortic valve replacement (TAVR) recipients is unknown. The aim of this study was to determine the impact of preexisting LBBB on clinical outcomes after TAVR. METHODS AND RESULTS: This multicenter study evaluated 3404 TAVR candidates according to the presence or absence of LBBB on baseline ECG. TAVR complications and causes of death were defined according to Valve Academic Research Consortium-2 definitions. Follow-up outpatient visits or telephone interviews were conducted at 30 days, 12 months, and yearly thereafter. Echocardiography examinations were performed at baseline, at hospital discharge, and at 1-year follow-up. Preexisting LBBB was present in 398 patients (11.7%) and was associated with an increased risk of permanent pacemaker implantation (PPI; 21.1% versus 14.8%; adjusted odds ratio, 1.51; 95% CI, 1.12-2.04) but not death (7.3% versus 5.5%; adjusted odds ratio, 1.33; 95% CI, 0.84-2.12) at 30 days. At a mean follow-up of 22±21 months, there were no differences between patients with and without preexisting LBBB in overall mortality (adjusted hazard ratio, 0.94; 95% CI, 0.75-1.18) and cardiovascular mortality (adjusted hazard ratio, 0.90; 95% CI, 0.68-1.21). In a subanalysis of 2421 patients without PPI at 30 days and with complete follow-up about the PPI, preexisting LBBB was not associated with an increased risk of PPI or sudden cardiac death. Patients with preexisting LBBB had a lower left ventricular ejection fraction (LVEF) at baseline and at 1-year follow-up ( P <0.001 for both), but those with low LVEF exhibited a similar increase in LVEF over time after TAVR compared with patients with no preexisting LBBB ( P=0.327). CONCLUSIONS: Preexisting LBBB significantly increased the risk of early (but not late) PPI after TAVR, without any significant effect on overall mortality or cardiovascular mortality. Preexisting LBBB was associated with lower LVEF pre-TAVR but did not prevent an increase in LVEF post-TAVR similar to patients without LBBB.


Assuntos
Valva Aórtica/cirurgia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Doenças das Valvas Cardíacas/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Brasil/epidemiologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/mortalidade , Bloqueio de Ramo/fisiopatologia , Canadá/epidemiologia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/mortalidade , Ecocardiografia , Eletrocardiografia , Europa (Continente)/epidemiologia , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Marca-Passo Artificial , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
3.
Circ., cariovasc. interv. (Print) ; 11(11): 006927, Nov. 2018. tab, graf
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1223598

RESUMO

BACKGROUND: The impact of preexisting left bundle branch block (LBBB) in transcatheter aortic valve replacement (TAVR) recipients is unknown. The aim of this study was to determine the impact of preexisting LBBB on clinical outcomes after TAVR. METHODS AND RESULTS: This multicenter study evaluated 3404 TAVR candidates according to the presence or absence of LBBB on baseline ECG. TAVR complications and causes of death were defined according to Valve Academic Research Consortium-2 definitions. Follow-up outpatient visits or telephone interviews were conducted at 30 days, 12 months, and yearly thereafter. Echocardiography examinations were performed at baseline, at hospital discharge, and at 1-year follow-up. Preexisting LBBB was present in 398 patients (11.7%) and was associated with an increased risk of permanent pacemaker implantation (PPI; 21.1% versus 14.8%; adjusted odds ratio, 1.51; 95% CI, 1.12­2.04) but not death (7.3% versus 5.5%; adjusted odds ratio, 1.33; 95% CI, 0.84­2.12) at 30 days. At a mean follow-up of 22±21 months, there were no differences between patients with and without preexisting LBBB in overall mortality (adjusted hazard ratio, 0.94; 95% CI, 0.75­1.18) and cardiovascular mortality (adjusted hazard ratio, 0.90; 95% CI, 0.68­1.21). In a subanalysis of 2421 patients without PPI at 30 days and with complete follow-up about the PPI, preexisting LBBB was not associated with an increased risk of PPI or sudden cardiac death. Patients with preexisting LBBB had a lower left ventricular ejection fraction (LVEF) at baseline and at 1-year follow-up (P <0.001 for both), but those with low LVEF exhibited a similar increase in LVEF over time after TAVR compared with patients with no preexisting LBBB (P=0.327). CONCLUSIONS: Preexisting LBBB significantly increased the risk of early (but not late) PPI after TAVR, without any significant effect on overall mortality or cardiovascular mortality. Preexisting LBBB was associated with lower LVEF pre-TAVR but did not prevent an increase in LVEF post-TAVR similar to patients without LBBB.


Assuntos
Bloqueio de Ramo , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos
4.
JACC Cardiovasc Interv ; 11(17): 1669-1679, 2018 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-30190058

RESUMO

OBJECTIVES: The authors aimed to determine the procedural learning curve and minimum annual institutional volumes associated with optimum clinical outcomes for transcatheter aortic valve replacement (TAVR). BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a complex procedure requiring significant training and experience for successful outcome. Despite increasing use of TAVR across institutions, limited information is available for its learning curve characteristics and minimum annual volumes required to optimize clinical outcomes. METHODS: The study collected data for patients at 16 centers participating in the international TAVR registry since initiation of the respective TAVR program. All cases were chronologically ordered into initial (1 to 75), early (76 to 150), intermediate (151 to 225), high (226 to 300), and very high (>300) experience operators for TAVR learning curve characterization. In addition, participating institutions were stratified by annual TAVR case volume into low-volume (<50), moderate-volume (50 to 100), and high-volume (>100) groups for comparative analysis. Procedural and 30-day clinical outcomes were collected and multivariate regression analysis performed for 30-day mortality and the early safety endpoint. RESULTS: A total of 3,403 patients comprised the study population. On multivariate analysis, all-cause mortality was significantly higher for initial (odds ratio [OR]: 3.83; 95% confidence interval [CI]: 1.93 to 7.60), early (OR: 2.41; 95% CI: 1.51 to 5.03), and intermediate (OR: 2.53; 95% CI: 1.19 to 5.40) experience groups compared with the very high experience operators. In addition, the early safety endpoint was significantly worse for all experience groups compared with the very high experience operators. Low annual volume (<50) TAVR institutions had significantly higher all-cause 30-day mortality (OR: 2.70; 95% CI: 1.44 to 5.07) and worse early safety endpoint (OR: 1.60; 95% CI: 1.17 to 2.17) compared with the moderate- and high-volume groups. There was no difference in patient outcomes between intermediate and high annual volume groups. CONCLUSIONS: TAVR procedures display important learning curve characteristics with both greater procedural safety and a lower mortality when performed by experienced operators. In addition, TAVR performed at low annual volume (<50 procedures) institutions is associated with decreased procedural safety and higher patient mortality. These findings have important implications for operator training and patient care at centers performing TAVR.


Assuntos
Competência Clínica/normas , Hospitais com Alto Volume de Atendimentos/normas , Hospitais com Baixo Volume de Atendimentos/normas , Curva de Aprendizado , Avaliação de Processos e Resultados em Cuidados de Saúde/normas , Cirurgiões/normas , Substituição da Valva Aórtica Transcateter/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Segurança do Paciente/normas , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Carga de Trabalho/normas
5.
JACC cardiovasc. interv ; 11(17): 1669-1679, Sept. 2018. graf, tab
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1247793

RESUMO

OBJECTIVES: The authors aimed to determine the procedural learning curve and minimum annual institutional volumes associated with optimum clinical outcomes for transcatheter aortic valve replacement (TAVR).BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a complex procedure requiring significant training and experience for successful outcome. Despite increasing use of TAVR across institutions, limited information is available for its learning curve characteristics and minimum annual volumes required to optimize clinical outcomes. METHODS: The study collected data for patients at 16 centers participating in the international TAVR registry since initiation of the respective TAVR program. All cases were chronologically ordered into initial (1 to 75), early (76 to 150), intermediate (151 to 225), high (226 to 300), and very high (>300) experience operators for TAVR learning curve characterization. In addition, participating institutions were stratified by annual TAVR case volume into low-volume (<50), moderate-volume (50 to 100), and high-volume (>100) groups for comparative analysis. Procedural and 30-day clinical outcomes were collected and multivariate regression analysis performed for 30-day mortality and the early safety endpoint. RESULTS: A total of 3,403 patients comprised the study population. On multivariate analysis, all-cause mortality was significantly higher for initial (odds ratio [OR]: 3.83; 95% confidence interval [CI]: 1.93 to 7.60), early (OR: 2.41; 95%CI: 1.51 to 5.03), and intermediate (OR: 2.53; 95% CI: 1.19 to 5.40) experience groups compared with the very high experience operators. In addition, the early safety endpoint was significantly worse for all experience groups compared with the very high experience operators. Low annual volume (<50) TAVR institutions had significantly higher all-cause30-day mortality (OR: 2.70; 95% CI: 1.44 to 5.07) and worse early safety endpoint (OR: 1.60; 95% CI: 1.17 to 2.17) compared with the moderate- and high-volume groups. There was no difference in patient outcomes between intermediate and high annual volume groups. CONCLUSIONS: TAVR procedures display important learning curve characteristics with both greater procedural safety and a lower mortality when performed by experienced operators. In addition, TAVR performed at low annual volume (<50 procedures) institutions is associated with decreased procedural safety and higher patient mortality. These findings have important implications for operator training and patient care at centers performing TAVR.


Assuntos
Humanos , Feminino , Idoso de 80 Anos ou mais , Curva de Aprendizado , Substituição da Valva Aórtica Transcateter/efeitos adversos
6.
Int J Cardiol ; 245: 222-227, 2017 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-28760395

RESUMO

BACKGROUND: Despite rapidly increasing use of TAVR across institutions, limited data is available for the effect of procedural experience on TAVR outcomes. We investigate the relationship between institutional experience and TAVR outcomes. METHODS: 1953 patients undergoing TAVR at 8 international sites were grouped into chronological quantiles (Q) to assess temporal changes on procedural and clinical outcomes and multivariate logistic regression performed to determine predictors of device success, early safety and all-cause mortality. RESULTS: The mean age of patients was 81±7years and 991 (51%) were female. The quantiles comprised of first 62 cases for Q1, 63-133 for Q2, 134 to 242 for Q3 and 243 to 476 for Q4. Device success increased from Q1 to Q4 (78% vs 89%, p<0.001) with significant improvement in the early safety endpoint (19% vs 10%, p<0.001). All cause mortality reduced by half in Q4 compared to Q1 (8% vs 4%, p=0.01) and rates of major vascular complications, major bleeding and valve embolization decreased with increasing experience. The multivariate analysis identified TAVR in Q3 and Q4 to be independently associated with higher device success and lower risk of complications. TAVR in Q4 was independently associated with lower mortality (OR 0.36 95% CI 0.19-0.70, p=0.002). CONCLUSIONS: Greater institutional experience with TAVR procedures improves device success and clinical outcomes. An experience of >242 cases is independently associated with lower mortality. These findings have important implications for defining minimum volume criteria for institutions and training standards for TAVR procedure.


Assuntos
Internacionalidade , Complicações Pós-Operatórias/mortalidade , Sistema de Registros , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/tendências , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Mortalidade/tendências , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Prospectivos , Resultado do Tratamento
7.
JACC Cardiovasc Interv ; 10(15): 1564-1574, 2017 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-28734885

RESUMO

OBJECTIVES: This study sought to assess the influence of baseline right bundle branch block (RBBB) on all-cause and cardiovascular mortality as well as sudden cardiac death (SCD) among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Few data exist regarding the late clinical impact of pre-existing RBBB in TAVR recipients. METHODS: A total of 3,527 patients (mean age 82 ± 8 years, 50.1% men) were evaluated according to the presence of RBBB on baseline electrocardiography. Intraventricular conduction abnormalities were classified according to the American Heart Association, American College of Cardiology Foundation, and Heart Rhythm Society recommendations for standardization and interpretation of the electrocardiogram. TAVR complications and causes of death were defined according to Valve Academic Research Consortium 2 definitions. RESULTS: RBBB was present on baseline electrocardiography in 362 patients (10.3%) and associated with higher 30-day rates of permanent pacemaker implantation (PPI) (40.1% vs. 13.5%; p < 0.001) and death (10.2% vs. 6.9%; p = 0.024). At a mean follow-up of 20 ± 18 months, pre-existing RBBB was independently associated with all-cause mortality (hazard ratio [HR]: 1.31; 95% confidence interval [CI]: 1.06 to 1.63; p = 0.014) and cardiovascular mortality (HR: 1.45; 95% CI: 1.11 to 1.89; p = 0.006) but not with SCD (HR: 0.71; 95% CI: 0.22 to 2.32; p = 0.57). Patients with pre-existing RBBB and without PPI at discharge from the index hospitalization had the highest 2-year risk for cardiovascular death (27.8%; 95% CI: 20.9% to 36.1%; log-rank p = 0.007). In a subanalysis of 1,245 patients without PPI at discharge from the index hospitalization and with complete follow-up regarding the need for PPI, pre-existing RBBB was independently associated with the composite of SCD and PPI (HR: 2.68; 95% CI: 1.16 to 6.17; p = 0.023). CONCLUSIONS: Pre-existing RBBB was found in 10% of TAVR recipients and was associated with poorer clinical outcomes. Patients with baseline RBBB without permanent pacemakers at hospital discharge may be at especially high risk for high-degree atrioventricular block and/or SCD during follow-up. Future studies should evaluate strategies aimed at the early detection of patients at risk for late development of high-degree atrioventricular block.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bloqueio de Ramo/mortalidade , Morte Súbita Cardíaca/epidemiologia , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Brasil/epidemiologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Canadá/epidemiologia , Causas de Morte , Ecocardiografia , Eletrocardiografia , Europa (Continente)/epidemiologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Modelos de Riscos Proporcionais , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
JACC cardiovasc. interv ; 10(15): 1564-1574, 2017. tab, graf
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1064046

RESUMO

This study sought to assess the influence of baseline right bundle branch block (RBBB) on all-cause and cardiovascular mortality as well as sudden cardiac death (SCD) among patients undergoing transcatheter aortic valve replacement (TAVR). Few data exist regarding the late clinical impact of pre-existing RBBB in TAVR recipients. A total of 3,527 patients (mean age 82 8 years, 50.1% men) were evaluated according to the presence of RBBB on baseline electrocardiography. Intraventricular conduction abnormalities were classified according to the American Heart Association, American College of Cardiology Foundation, and Heart Rhythm Society recommendations for standardization and interpretation of the electrocardiogram. TAVR complications and causes of death were defined according to Valve Academic Research Consortium 2 definitions. RBBB was present on baseline electrocardiography in 362 patients (10.3%) and associated with higher 30-day rates of permanent pacemaker implantation (PPI) (40.1% vs. 13.5%; p < 0.001) and death (10.2% vs. 6.9%; p » 0.024). At a mean follow-up of 20 18 months, pre-existing RBBB was independently associated with all-cause mortality (hazard ratio [HR]: 1.31; 95% confidence interval [CI]: 1.06 to 1.63; p » 0.014) and cardiovascular mortality (HR: 1.45; 95% CI: 1.11 to 1.89; p » 0.006) but not with SCD (HR: 0.71; 95% CI: 0.22 to 2.32; p » 0.57). Patients with pre-existing RBBB and without PPI at discharge from the index hospitalization had the highest 2-year risk for cardiovascular death (27.8%; 95% CI: 20.9% to 36.1%; log-rank p » 0.007). In a subanalysis of 1,245 patients without PPI at discharge from the index hospitalization and with complete follow-up regarding the need for PPI, pre-existing RBBB was independently associated with the composite of SCD and PPI (HR: 2.68; 95% CI: 1.16 to 6.17; p » 0.023)


Assuntos
Bloqueio de Ramo , Implante de Prótese de Valva Cardíaca , Morte Súbita Cardíaca
9.
J Am Coll Cardiol ; 65(5): 437-48, 2015 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-25660921

RESUMO

BACKGROUND: Little evidence exists of the burden and predictors of cardiac death after transcatheter aortic valve replacement (TAVR). OBJECTIVES: The purpose of this study was to assess the incidence and predictors of cardiac death from advanced heart failure (HF) and sudden cardiac death (SCD) in a large patient cohort undergoing TAVR. METHODS: The study included a total of 3,726 patients who underwent TAVR using balloon (57%) or self-expandable (43%) valves. Causes of death were defined according to the Valve Academic Research Consortium-2. RESULTS: At a mean follow-up of 22 ± 18 months, 155 patients had died due to advanced HF (15.2% of total deaths, 46.1% of deaths from cardiac causes) and 57 had died due to SCD (5.6% of deaths, 16.9% of cardiac deaths). Baseline comorbidities (chronic obstructive pulmonary disease, atrial fibrillation, left ventricular ejection fraction ≤40%, lower mean transaortic gradient, pulmonary artery systolic pressure >60 mm Hg; p < 0.05 for all) and 2 procedural factors (transapical approach, hazard ratio [HR]: 2.38, 95% confidence interval [CI]: 1.60 to 3.54; p < 0.001; presence of moderate or severe aortic regurgitation after TAVR, HR: 2.79, 95% CI: 1.82 to 4.27; p < 0.001) independently predicted death from advanced HF. Left ventricular ejection fraction ≤40% (HR: 1.93, 95% CI: 1.05 to 3.55; p = 0.033) and new-onset persistent left bundle-branch block following TAVR (HR: 2.26, 95% CI: 1.23 to 4.14; p = 0.009) were independently associated with an increased risk of SCD. Patients with new-onset persistent left bundle-branch block and a QRS duration >160 ms had a greater SCD risk (HR: 4.78, 95% CI: 1.56 to 14.63; p = 0.006). CONCLUSIONS: Advanced HF and SCD accounted for two-thirds of cardiac deaths in patients after TAVR. Potentially modifiable or treatable factors leading to increased risk of mortality for HF and SCD were identified. Future studies should determine whether targeting these factors decreases the risk of cardiac death.


Assuntos
Morte Súbita Cardíaca/epidemiologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Insuficiência Cardíaca/epidemiologia , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/epidemiologia , Valor Preditivo dos Testes , Resultado do Tratamento
10.
J. Am. Coll. Cardiol ; 65(05): 437-448, 2015. ilus
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063741

RESUMO

BACKGROUND Little evidence exists of the burden and predictors of cardiac death after transcatheter aortic valvereplacement (TAVR).OBJECTIVES The purpose of this study was to assess the incidence and predictors of cardiac death from advancedheart failure (HF) and sudden cardiac death (SCD) in a large patient cohort undergoing TAVR.METHODS The study included a total of 3,726 patients who underwent TAVR using balloon (57%) or self-expandable(43%) valves. Causes of death were defined according to the Valve Academic Research Consortium–2.RESULTS At a mean follow-up of 22 18 months, 155 patients had died due to advanced HF (15.2% of total deaths,46.1% of deaths from cardiac causes) and 57 had died due to SCD (5.6% of deaths, 16.9% of cardiac deaths). Baselinecomorbidities (chronic obstructive pulmonary disease, atrial fibrillation, left ventricular ejection fraction #40%, lowermean transaortic gradient, pulmonary artery systolic pressure >60 mm Hg; p 160 ms had a greater SCD risk (HR: 4.78, 95% CI: 1.56 to 14.63; p » 0.006).CONCLUSIONS Advanced HF and SCD accounted for two-thirds of cardiac deaths in patients after TAVR.Potentially modifiable or treatable factors leading to increased risk of mortality for HF and SCD were identified. Future.


Assuntos
Insuficiência Cardíaca , Morte Súbita , Substituição da Valva Aórtica Transcateter
11.
JACC Cardiovasc Interv ; 7(9): 1022-32, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25234675

RESUMO

OBJECTIVES: The aim of this study was to determine the impact of the degree of residual aortic regurgitation (AR) and acuteness of presentation of AR after transcatheter aortic valve replacement (TAVR) on outcomes. BACKGROUND: The degree of residual AR after TAVR leading to excess mortality remains controversial, and little evidence exists on the impact of the acuteness of presentation of AR. METHODS: A total of 1,735 patients undergoing TAVR with balloon-expandable or self-expanding valves were included. The presence and degree of AR were evaluated by transthoracic echocardiography; acute AR was defined as an increase in AR severity of ≥1 degree compared with pre-procedural echocardiography. RESULTS: Residual AR was classified as mild in 761 patients (43.9%) and moderate to severe in 247 patients (14.2%). The presence of moderate to severe AR was an independent predictor of mortality at a mean follow-up of 21 ± 17 months compared with none to trace (adjusted hazard ratio [HR]: 1.81, 95% confidence interval [CI]: 1.32 to 2.48; p < 0.001) and mild AR (adjusted HR: 1.68, 95% CI: 1.27 to 2.24; p < 0.001) groups. There was no increased risk in patients with mild AR compared with those with none to trace AR (p = 0.393). In patients with moderate to severe AR, acute AR was observed in 161 patients (65%) and chronic AR in 86 patients (35%). Acute moderate to severe AR was independently associated with increased risk of mortality compared with none/trace/mild AR (adjusted HR: 2.37, 95% CI: 1.53 to 3.66; p < 0.001) and chronic moderate to severe AR (adjusted HR: 2.24, 95% CI: 1.17 to 4.30; p = 0.015) [corrected]. No differences in survival rate were observed between patients with chronic moderate to severe and none/trace/mild AR (p > 0.50). CONCLUSIONS: AR occurred very frequently after TAVR, but an increased risk of mortality at ∼2-year follow-up was observed only in patients with acute moderate to severe AR.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/terapia , Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Canadá , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Modelos de Riscos Proporcionais , Desenho de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Espanha , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia , Função Ventricular Esquerda
12.
Eur Heart J ; 35(38): 2685-96, 2014 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-24796337

RESUMO

AIM: The aim of this study was to determine the effects of advanced chronic kidney disease (CKD) on early and late outcomes after transcatheter aortic valve implantation (TAVI), and to evaluate the predictive factors of poorer outcomes in such patients. METHODS AND RESULTS: This was a multicentre study including a total of 2075 consecutive patients who had undergone TAVI. Patients were grouped according the estimated glomerular filtration rate as follows: CKD stage 1-2 (≥60 mL/min/1.73 m(2); n = 950), stage 3 (30-59 mL/min/1.73 m(2); n = 924), stage 4 (15-29 mL/min/1.73 m(2); n = 134) and stage 5 (<15 mL/min/1.73 m² or dialysis; n = 67). Clinical outcomes were evaluated at 30-days and at follow-up (median of 15 [6-29] months) and defined according to the VARC criteria. Advanced CKD (stage 4-5) was an independent predictor of 30-day major/life-threatening bleeding (P = 0.001) and mortality (P = 0.027), and late overall, cardiovascular and non-cardiovascular mortality (P < 0.01 for all). Pre-existing atrial fibrillation (HR: 2.29, 95% CI: 1.47-3.58, P = 0.001) and dialysis therapy (HR: 1.86, 95% CI: 1.17-2.97, P = 0.009) were the predictors of mortality in advanced CKD patients, with a mortality rate as high as 71% at 1-year follow-up in those patients with these 2 factors. Advanced CKD patients who had survived at 1-year follow-up exhibited both a significant improvement in NYHA class (P < 0.001) and no deterioration in valve hemodynamics (P = NS for changes in mean gradient and valve area over time). CONCLUSIONS: Advanced CKD was associated with a higher rate of early and late mortality and bleeding events following TAVI, with AF and dialysis therapy determining a higher risk in these patients. The mortality rate of patients with both factors was unacceptably high and this should be taken into account in the clinical decision-making process in this challenging group of patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Insuficiência Renal Crônica/complicações , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Feminino , Hemodinâmica/fisiologia , Humanos , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/mortalidade , Prognóstico , Insuficiência Renal Crônica/mortalidade , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
13.
Circulation ; 129(11): 1233-43, 2014 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-24370552

RESUMO

BACKGROUND: Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. METHODS AND RESULTS: A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74-1.30; P=0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56-1.17; P=0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77-1.30; P=0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11-0.85; P=0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time (P=0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, -2.26; 95% confidence interval, -4.07 to -0.44; P=0.013; R(2)=0.121). CONCLUSIONS: The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.


Assuntos
Valva Aórtica/cirurgia , Cateterismo Cardíaco/tendências , Implante de Prótese de Valva Cardíaca/tendências , Marca-Passo Artificial/tendências , Função Ventricular Esquerda/fisiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/patologia , Cateterismo Cardíaco/mortalidade , Estudos de Coortes , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
14.
Circ Cardiovasc Interv ; 6(6): 625-34, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24280965

RESUMO

BACKGROUND: There is scant information on the prevalence and factors associated with preoperative anemia in patients undergoing transcatheter aortic valve implantation (TAVI) and whether it is associated with mortality. We sought to determine the prevalence and factors associated with preoperative anemia in addition to the prognostic effects of the various levels of preoperative hemoglobin level on mortality in patients undergoing TAVI. METHODS AND RESULTS: Ten-center observational study encompassing 1696 patients with aortic stenosis who underwent TAVI was conducted. Anemia was defined by the World Health Organization criteria (hemoglobin <12.0 g/dL in women and <13.0 g/dL in men). The prevalence of preoperative anemia was 57%. Patient-related factors associated with preoperative anemia were (descending order of odds ratio [95% confidence interval]) as follows: anemia-related medication (4.90 [3.08-7.80]), history of heart failure (1.77 [1.43-2.20]), male sex (1.69 [1.32-2.16]), mitral regurgitation grade ≥III (1.61 [1.15-2.25]), history of malignancy (1.44 [1.03-2.09]), and peripheral vascular disease (1.33 [1.04-1.70]). The creatinine clearance was inversely associated with preoperative anemia (odds ratio, 0.92 [0.87-0.97]). In multivariable analyses, preoperative anemia was not associated with 30-day mortality (1.72 [0.96-3.12]; P=0.073) but showed the strongest association with 1-year mortality with a hazard ratio (95% confidence interval) of 2.78 (1.60-4.82) in patients with hemoglobin <10 g/dL. Patients with anemia received ≥1 blood transfusion 2× more often, but the indication of transfusion was unrelated to overt bleeding in 60%. Blood transfusion was associated with mortality at 30 days (odds ratio, 1.25 [95% confidence interval, 1.08-3.67]) and during follow-up (hazard ratio, 1.09 [95% confidence interval, 1.03-1.14]). CONCLUSIONS: Preoperative anemia is prevalent in >50% of patients undergoing TAVI. Various baseline factors were related to anemia, which in turn was associated with 1-year mortality. Patients with anemia received more transfusions but mostly for indications unrelated to overt bleeding, whereas transfusion was independently associated with both early and 1-year mortality. These findings indicate that optimization of baseline factors related to preoperative anemia, in addition to more strict criteria of the use of blood products, may improve outcome after TAVI.


Assuntos
Anemia/complicações , Anemia/epidemiologia , Cateterismo Cardíaco/mortalidade , Implante de Prótese de Valva Cardíaca/mortalidade , Próteses Valvulares Cardíacas , Valvas Cardíacas/cirurgia , Período Pré-Operatório , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Transfusão de Sangue , Feminino , Seguimentos , Humanos , Masculino , Prevalência , Prognóstico , Estudos Retrospectivos , Fatores Sexuais , Taxa de Sobrevida , Fatores de Tempo
15.
Tex Heart Inst J ; 40(3): 323-5, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23914032

RESUMO

Transcatheter aortic valve implantation for aortic stenosis has evolved as an alternative treatment for patients who are at high or excessive surgical risk. We report the case of an 84-year-old man with a degenerated surgically implanted valve in a subaortic position (9 mm below the native annulus) who underwent "valve-in-valve" transcatheter aortic valve implantation with use of a Medtronic CoreValve system. We planned to deploy the CoreValve at a conventional depth in the left ventricular outflow tract; we realized that this might result in paravalvular regurgitation, but it would also afford a "deep" landing site for a second valve, if necessary. Ultimately, we implanted a second CoreValve deep in the left ventricular outflow tract to seal a paravalvular leak. The frame of the first valve--positioned at the conventional depth--enabled secure anchoring of the second valve in a deeper position, which in turn effected successful treatment of the failing subaortic surgical prosthesis without paravalvular regurgitation.


Assuntos
Insuficiência da Valva Aórtica/terapia , Estenose da Valva Aórtica/cirurgia , Bioprótese , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Falha de Prótese , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/etiologia , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Radiografia Intervencionista , Resultado do Tratamento
16.
J Am Coll Cardiol ; 62(17): 1552-62, 2013 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-23954337

RESUMO

OBJECTIVES: This study sought to evaluate the main baseline and procedural characteristics, management, and clinical outcomes of patients from a large cohort of patients undergoing transcatheter aortic valve implantation (TAVI) who suffered coronary obstruction (CO). BACKGROUND: Very little data exist on CO following TAVI. METHODS: This multicenter registry included 44 patients who suffered symptomatic CO following TAVI of 6,688 patients (0.66%). Pre-TAVI computed tomography data was available in 28 CO patients and in a control group of 345 patients (comparisons were performed including all patients and a cohort matched 1:1 by age, sex, previous coronary artery bypass graft, transcatheter valve type, and size). RESULTS: Baseline and procedural variables associated with CO were older age (p < 0.001), female sex (p < 0.001), no previous coronary artery bypass graft (p = 0.043), the use of a balloon-expandable valve (p = 0.023), and previous surgical aortic bioprosthesis (p = 0.045). The left coronary artery was the most commonly involved (88.6%). The mean left coronary artery ostia height and sinus of Valsalva diameters were lower in patients with obstruction than in control subjects (10.6 ± 2.1 mm vs. 13.4 ± 2.1 mm, p < 0.001; 28.1 ± 3.8 mm vs. 31.9 ± 4.1 mm, p < 0.001). Differences between groups remained significant after the case-matched analysis (p < 0.001 for coronary height; p = 0.01 for sinus of Valsalva diameter). Most patients presented with persistent severe hypotension (68.2%) and electrocardiographic changes (56.8%). Percutaneous coronary intervention was attempted in 75% of the cases and was successful in 81.8%. Thirty-day mortality was 40.9%. After a median follow-up of 12 (2 to 18) months, the cumulative mortality rate was 45.5%, and there were no cases of stent thrombosis or reintervention. CONCLUSIONS: Symptomatic CO following TAVI was a rare but life-threatening complication that occurred more frequently in women, in patients receiving a balloon-expandable valve, and in those with a previous surgical bioprosthesis. Lower-lying coronary ostium and shallow sinus of Valsalva were associated anatomic factors, and despite successful treatment, acute and late mortality remained very high, highlighting the importance of anticipating and preventing the occurrence of this complication.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Oclusão Coronária/diagnóstico , Cardiopatias Congênitas/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Sistema de Registros , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Estudos de Coortes , Oclusão Coronária/mortalidade , Oclusão Coronária/terapia , Gerenciamento Clínico , Feminino , Cardiopatias Congênitas/mortalidade , Doenças das Valvas Cardíacas/mortalidade , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do Tratamento
17.
Am J Cardiol ; 112(1): 104-10, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-23566540

RESUMO

In-hospital infection (IHI) after transcatheter aortic valve implantation (TAVI) has received little attention, although it may have a significant effect on outcomes and costs because of prolonged hospital stay. Therefore, the aim of this study was to determine the incidence, type, predictors, and prognostic effects of IHI after TAVI. This study included 298 consecutive patients from 2 centers who underwent TAVI from November 2005 to November 2011. IHI during the hospital stay was defined on the basis of symptoms and signs assessed by the attending physician in the cardiac care unit or medium care unit in combination with all technical examinations performed to confirm infection. IHI after TAVI was observed in 58 patients (19.5%): urinary tract infections in 25 patients (43.1%), pneumonia in 12 patients (20.7%), and access-site infections in 7 patients (12.1%). In 12 patients (20.7%), the site of infection could not be determined, and 2 patients (3.4%) had multiple infection sites. Multivariate analysis revealed that surgical access through the femoral artery was the most important determinant of infection (odds ratio [OR] 4.18, 95% confidence interval [CI] 1.02 to 17.19), followed by perioperative major stroke (OR 3.21, 95% CI 1.01 to 9.52) and overweight (body mass index ≥25 kg/m²; OR 2.27, 95% CI 1.12 to 4.59). The length of hospital stay in patients with IHIs was 15.0 days (interquartile range 8.0 to 22.0) compared with 7.0 days (interquartile range 4.0 to 10.0) in patients without infections (p <0.0001). Kaplan-Meier estimates of survival at 1 year were 76.6% and 74.4% (log-rank, p = 0.61), respectively. Unadjusted and adjusted OR analysis revealed that IHI did not predict mortality at 30 days (OR 1.27, 95% CI 0.49 to 3.30) or at 1 year (hazard ratio 1.24, 95% CI 0.68 to 2.25). In conclusion, IHI occurred in 19.5% of the patients. Patient-related and, more important, procedure-related variables play a role in the occurrence of infection, indicating that improvements in the execution of TAVI may lead to a reduction of this complication.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Infecção Hospitalar/epidemiologia , Implante de Prótese de Valva Cardíaca/métodos , Complicações Pós-Operatórias/epidemiologia , Infecções Relacionadas à Prótese/epidemiologia , Infecção da Ferida Cirúrgica/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Antibioticoprofilaxia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Incidência , Masculino , Países Baixos/epidemiologia , Prognóstico , Estudos Prospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
18.
Circulation ; 126(25): 3041-53, 2012 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-23149669

RESUMO

BACKGROUND: The objective of this study was to evaluate the timing, predictive factors, and prognostic value of cerebrovascular events (CVEs) after transcatheter aortic valve implantation. METHODS AND RESULTS: The study included 1061 consecutive patients who underwent transcatheter aortic valve implantation with a balloon-expandable (64%) or self-expandable (36%) valve. CVEs were classified as acute (≤24 hours), subacute (1-30 days), or late (>30 days). CVEs occurred in 54 patients (5.1%; stroke, 4.2%) within 30 days after transcatheter aortic valve implantation (acute in 54% of cases). The predictors of acute CVEs were balloon postdilation of the valve prosthesis (odds ratio, 2.46; 95% confidence interval,1.07-5.67) and valve dislodgment/embolization (odds ratio, 4.36; 95% CI, 1.21-15.69); new-onset atrial fibrillation (odds ratio, 2.76; 95% CI, 1.11-6.83) was a predictor of subacute CVEs. Late CVEs occurred in 35 patients (3.3%; stroke, 2.1%) at a median follow-up of 12 months (3-23 months). The predictors of late CVEs were chronic atrial fibrillation (2.84; 95% CI, 1.46-5.53), peripheral vascular disease (hazard ratio, 2.02; 95% CI, 1.02-3.97), and prior cerebrovascular disease (hazard ratio, 2.04; 95% CI, 1.01-4.15). Major stroke was associated with 30-day (odds ratio, 7.43; 95% CI, 2.45-22.53) and late (hazard ratio, 1.75; 95% CI, 1.01-3.04) mortality. CONCLUSIONS: In a large cohort of patients undergoing transcatheter aortic valve implantation, the rates of acute and subacute CVEs were 2.7% and 2.4%, respectively. While balloon postdilation and valve dislodgment/embolization were the predictors of acute CVEs, new-onset atrial fibrillation determined a higher risk for subacute events. Late events were determined mainly by a history of chronic atrial fibrillation and peripheral and cerebrovascular disease. The occurrence of major stroke was associated with increased early and late mortality. These results provide important insights for the implementation of preventive measures for CVEs after transcatheter aortic valve implantation.


Assuntos
Valva Aórtica/cirurgia , Transtornos Cerebrovasculares/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Complicações Pós-Operatórias/etiologia , Idoso , Idoso de 80 Anos ou mais , Transtornos Cerebrovasculares/mortalidade , Estudos de Coortes , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Prognóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo
19.
Circ Cardiovasc Interv ; 5(5): 680-8, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23048055

RESUMO

BACKGROUND: Blood transfusion is associated with acute kidney injury (AKI) after transcatheter aortic valve implantation (TAVI). We sought to elucidate in more detail the relation between blood transfusion and AKI and its effects on short- and long-term mortality. METHODS AND RESULTS: Nine hundred ninety-five patients with aortic stenosis underwent TAVI with the Medtronic CoreValve or the Edwards Valve in 7 centers. AKI was defined by the Valve Academic Research Consortium (absolute increase in serum creatinine ≥0.3 mg/dL [≥26.4 µmol/L] or ≥50% increase ≤72 hours). Logistic and Cox regression was used for predictor and survival analysis. AKI occurred in 20.7% (n=206). The number of units of blood transfusion ≤24 hours was the strongest predictor of AKI (≥5 units, OR, 4.81 [1.45-15.95], 3-4 units, OR, 3.05 [1.24-7.53], 1-2 units, OR, 1.47 [0.98-2.22]) followed by peripheral vascular disease (OR, 1.48 [1.05-2.10]), history of heart failure (OR, 1.43 [1.01-2.03]), leucocyte count ≤72 hours after TAVI (OR, 1.05 [1.02-1.09]) and European System for Cardiac Operative Risk Evaluation (EuroSCORE; OR, 1.02 [1.00-1.03]). Potential triggers of blood transfusion such as baseline anemia, bleeding-vascular complications, and perioperative blood loss were not identified as predictors. AKI and life-threatening bleeding were independent predictors of 30-day mortality (OR, 3.15 [1.56-6.38], OR, 6.65 [2.28-19.44], respectively), whereas transfusion (≥3 units), baseline anemia, and AKI predicted mortality beyond 30 days. CONCLUSIONS: AKI occurred in 21% of the patients after TAVI. The number of blood transfusions but not the indication of transfusion predicted AKI. AKI was a predictor of both short- and long-term mortality, whereas blood transfusion predicted long-term mortality. These findings indicate that outcome of TAVI may be improved by more restrictive use of blood transfusions.


Assuntos
Injúria Renal Aguda/etiologia , Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Reação Transfusional , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/mortalidade , Injúria Renal Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Transfusão de Sangue/mortalidade , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Colômbia , Comorbidade , Europa (Continente) , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Razão de Chances , Modelos de Riscos Proporcionais , Quebeque , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
Tex Heart Inst J ; 39(3): 351-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22719143

RESUMO

At our institutions, increasing numbers of aortic stenosis patients were not candidates for surgical aortic valve replacement. Accordingly, we initiated the Cali Colombian Transcatheter Aortic Valve Implantation (TAVI) program. From March 2008 through January 2011, 53 consecutive patients (mean age, 79 ± 6 yr; men, 58%) underwent TAVI with the Medtronic CoreValve System, and data were prospectively collected. Our study's endpoints conformed with Valve Academic Research Consortium recommendations. We report our clinical results.Predicted mortality rates were 25% (interquartile range, 17%-34%) according to logistic EuroSCORE and 6% (interquartile range, 3%-8%) according to the Society of Thoracic Surgeons score. The 30-day mortality rate was 9% (3 intraprocedural deaths, 5 total). The combined 30-day safety endpoint was 30% (major vascular sequelae, 23%; life-threatening bleeding, 12%; myocardial infarction, 4%; major stroke, 4%; and acute kidney injury [stage 3], 2%). Eight patients (15%) required post-implantation balloon dilation and 2 (4%) required valve-in-valve implantation, for a technical device success rate of 77%. Mean peak transvalvular gradient decreased from 74 ± 29 to 17 ± 8 mmHg and mean transvalvular gradient from 40 ± 17 to 8 ± 4 mmHg (both P=0.001). Moderate or severe aortic regurgitation decreased from 32% to 18% (P=0.12) and mitral regurgitation from 32% to 13% (P=0.002). The 1-year survival rate was 81%.We found that TAVI with the CoreValve prosthesis was safe and feasible, with sustained long-term results, for treating aortic stenosis in patients at excessive surgical risk; nonetheless, serious adverse events occurred in 30% of the patients.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Colômbia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA