Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 355
Filtrar
1.
Int J Surg ; 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38833328

RESUMO

BACKGROUND: Venous thromboembolism (VTE) significantly affects the prognosis of surgical patients with inguinal hernia. The complex Caprini score, commonly used for postoperative VTE risk assessment, poses practical challenges for surgeons in clinical settings. METHODS: The CHAT-3 trial, a prospective, multicenter, randomized controlled trial, compared a simple three-factor model to assess VTE risk against routine practices in post-inguinal hernia surgery (IHS) patients. The patients were randomly assigned (1:1) to the intervention or control arm. The intervention group used the three-factor model to identify patients at moderate or high risk of VTE for subsequent prophylaxis according to clinical guidelines. Both groups were followed for four weeks, with randomization implemented using computer-generated sequences. The primary outcome measured was the rate of VTE prophylaxis. Secondary outcomes included time spent on VTE risk assessment (surgeon self-reported), postoperative D-dimer trends, perioperative VTE occurrence, bleeding events, and the net clinical benefit. RESULTS: Of the 1,109 participants, 508 in the experimental group and 601 in the control group completed follow-up. The three-factor model showed higher VTE prophylaxis rates in all patients (pharmacologic prophylaxis: 26.2% vs. 6.00%, P<0.001) and particularly in those at high risk (pharmacologic prophylaxis: 57.3% vs. 9.50%, P<0.001). The experimental group significantly reduced VTE risk assessment time compared to the Caprini score (1.39±0.55 min vs. 5.73±1.35 min, P<0.001). The experimental group had lower D-dimer levels (0.26±0.73 mg/L vs. 0.35±0.55 mg/L, P=0.028). In the experimental group, the patients did not experience an increased risk of VTE (0% vs. 1.66%, P=0.268) and bleeding (1.18% vs. 0.67%, P=0.558) compared to the controls. There was no significant difference in net clinical benefit, which combined VTE and bleeding events, between the experimental and control groups (1.18% vs. 0.83%, P=0.559). CONCLUSION: Applying the simple three-factor model in perioperative VTE management could quickly identify the patient with a high risk of VTE and improve the prophylaxis rate of perioperative VTE. TRIAL REGISTRATION: XXX. TRIAL REGISTRATION: ChiCTR2000033769.

2.
Asian J Surg ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38834458
3.
Expert Rev Anticancer Ther ; : 1-10, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38761169

RESUMO

INTRODUCTION: This study aimed to estimate the toxicities of PARP inhibitors (PARPis), based on randomized controlled trials (RCTs) and the FDA Adverse Event Reporting System (FAERS) database. METHODS: Four electronic databases were searched from inception to 16 April 2024, for RCTs of approved PARPis. The primary and secondary outcomes were grade 3-5 adverse events (AEs) and grade 3-5 hematological AE, respectively. We conducted network meta-analyses to calculate the relative risks (RRs) and 95% confidence intervals (CIs) of outcomes. A disproportionality analysis was conducted to estimate the signals of hematological AEs associated with PARPis from the FAERS database. RESULTS: Overall, 27 RCTs involving 11,067 patients with cancer were included. Olaparib had the best safety profile for any grade 3-5 AEs and hematological AEs among four approved PARPis. Olaparib did not increase the risk of thrombocytopenia (RR: 1.48; 95%CI: 0.64-3.39), but other PARPis did. Furthermore 14,780 hematological AE reports associated with PARPis were identified in the FAERS database, and all PARPis were associated with strong hematological AE signals. Hematological AEs mainly occurred within the first 3 months (80.84%) after PARPi initiation. CONCLUSION: Olaparib had the best safety profile among five PARPis. PARPi-associated hematological AEs mainly occurred within the first 3 months. REGISTRATION: PROSPERO (CRD42022385274).

4.
Artigo em Inglês | MEDLINE | ID: mdl-38808470

RESUMO

Objectives: We aimed to compare the value of the semiquantitative parameters of 68Ga-labeled FAP inhibitor (68Ga-FAPI)-04 positron emission tomography/computed tomography (PET/CT) and 18F-fluorodeoxyglucose (18F-FDG) in diagnosing primary malignant and benign diseases. Materials and Methods: 18F-FDG and 68Ga-FAPI-04 PET/CT images of 80 patients were compared. Semiquantitative parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), peak SUV by lean body mass (SULpeak), metabolic tumor volume (or tumor volume of FAPI; FAPI-TV), and TLG (or total lesion activity of FAPI; FAPI-TLA), were automatically obtained using the IntelliSpace Portal image processing workstation with a threshold of 40% SUVmax. The liver blood pool was measured as the background, and the tumor-to-background ratio (TBRliver) was calculated. Results: In all malignant lesions, FAPI-TV and FAPI-TLA were higher in 68Ga-FAPI-04 PET/CT than in 18F-FDG. In the subgroup analysis, 68Ga-FAPI-04 had higher FAPI-TV and FAPI-TLA and lower SUVmax than 18F-FDG had in group A, including gynecological tumor, esophageal, and colorectal cancers. However, six semiquantitative parameters were higher in group B (the other malignant tumors). For the benign diseases, SUVmax, SUVmean, SUVpeak, and SULpeak were lower in 68Ga-FAPI-04 PET/CT than in 18F-FDG. 68Ga-FAPI-04 PET/CT showed a lower liver background and a higher TBRliver than 18F-FDG did. 68Ga-FAPI-04 PET/CT had higher accuracy, sensitivity, and specificity than 18F-FDG had. Conclusion: More accurate semiquantitative parameters and lower abdominal background in 68Ga-FAPI-04 PET/CT make it more competitive in the differential diagnosis of malignant and benign diseases than in 18F-FDG.

5.
Heliyon ; 10(10): e31532, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38807874

RESUMO

Background: Restoration of blood supply is a desired goal for the treatment of acute ischemic stroke. However, the restoration often leads to cerebral ischemia-reperfusion injury (CIR/I), which greatly increases the risk of non-neural organ damage. In particular, the acute kidney injury might be one of the most common complications. Aims: The study aimed to understand the damage occurred and the potential molecular mechanisms. Methods: The study was explored on the CIR/I rats generated by performing middle cerebral artery occlusion/reperfusion (MCAO/Reperfusion). The rats were evaluated with injury on the brains, followed by the non-neural organs including kidneys, livers, colons and stomachs. They were examined further with histopathological changes, and gene expression alterations by using RT-qPCR of ten aquaporins (Aqps) subtypes including Aqp1~Aqp9 and Aqp11. Furthermore, the Aqps expression profiles were constructed for each organ and analyzed by performing Principle Component Analysis. In addition, immunohistochemistry was explored to look at the protein expression of Aqp1, Aqp2, Aqp3 and Aqp4 in the rat kidneys. Results: There was a prominent down-regulation profile in the MCAO/Reperfusion rat kidneys. The protein expression of Aqp1, Aqp2, Aqp3 and Aqp4 was decreased in the kidneys of the MCAO/Reperfusion rats. We suggested that the kidney was in the highest risk to be damaged following the CIR/I. Down-regulation of Aqp2, Aqp3 and Aqp4 was involved in the acute kidney injury induced by the CIR/I.

6.
Am J Clin Nutr ; 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38729573

RESUMO

BACKGROUND: Long-chain free fatty acids (FFAs) are associated with risk of incident diabetes. However, a comprehensive assessment of the associations in normoglycemic populations is lacking. OBJECTIVES: Our study aimed to comprehensively investigate the prospective associations and patterns of FFA profiles with diabetes risk among normoglycemic Chinese adults. METHODS: This is a prospective nested case-control study from the China Cardiometabolic Disease and Cancer Cohort (4C) study. We quantitatively measured 53 serum FFAs using a targeted metabolomics approach in 1707 incident diabetes subjects and 1707 propensity score-matched normoglycemic controls. Conditional logistic regression models were employed to estimate odds ratios (ORs) for associations. Least Absolute Shrinkage and Selection Operator (LASSO) penalty regression and quantile g-computation (qg-comp) analyses were implemented to estimate the association between multi-FFA exposures and incident diabetes. RESULTS: The majority of odd-chain FFAs exhibited an inverse association with incident diabetes, wherein the ORs per SD increment of all 7 saturated fatty acids (SFAs), monounsaturated fatty acid (MUFA) 15:1, and polyunsaturated fatty acid (PUFA) 25:2 were ranging from 0.79 to 0.88 (95% CIs ranging between 0.71 and 0.97). Even-chain FFAs comprised 99.3% of total FFAs and displayed heterogeneity with incident diabetes. SFAs with 18-26 carbon atoms are inversely linked to incident diabetes, with ORs ranging from 0.81 to 0.86 (95% CIs ranging between 0.73 and 0.94). MUFAs 26:1 (OR: 0.85; 95% CI: 0.76, 0.94), PUFAs 20:4 (OR: 0.84; 95% CI: 0.75, 0.94), and 24:2 (OR: 0.87; 95% CI: 0.78, 0.97) demonstrated significant associations. In multi-FFA exposure model, 24 FFAs were significantly associated with incident diabetes, most of which were consistent with univariate results. The mixture OR was 0.78 (95% CI: 0.61, 0.99; P = 0.04159). Differential correlation network analysis revealed pre-existing perturbations in intraclass and interclass FFA coregulation before diabetes onset. CONCLUSIONS: These findings underscore the variations in diabetes risk associated with FFAs across chain length and unsaturation degree, highlighting the importance of recognizing FFA subtypes in the pathogenesis of diabetes.

8.
Front Physiol ; 15: 1352391, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38562620

RESUMO

For patients with chronic obstructive pulmonary disease (COPD), the assessment of the treatment efficacy during hospitalization is of importance to the optimization of clinical treatments. Conventional spirometry might not be sensitive enough to capture the regional lung function development. The study aimed to evaluate the feasibility of using electrical impedance tomography (EIT) as an objective bedside evaluation tool for the treatment of acute exacerbation of COPD (AECOPD). Consecutive patients who required hospitalization due to AECOPD were included prospectively. EIT measurements were conducted at the time of admission and before the discharge simultaneously when a forced vital capacity maneuver was conducted. EIT-based heterogeneity measures of regional lung function were calculated based on the impedance changes over time. Surveys for attending doctors and patients were designed to evaluate the ease of use, feasibility, and overall satisfaction level to understand the acceptability of EIT measurements. Patient-reported outcome assessments were conducted. User's acceptance of EIT technology was investigated with a five-dimension survey. A total of 32 patients were included, and 8 patients were excluded due to the FVC maneuver not meeting the ATS criteria. Spirometry-based lung function was improved during hospitalization but not significantly different (FEV1 %pred.: 35.8% ± 6.7% vs. 45.3% ± 8.8% at admission vs. discharge; p = 0.11. FVC %pred.: 67.8% ± 0.4% vs. 82.6% ± 5.0%; p = 0.15. FEV1/FVC: 0.41 ± 0.09 vs. 0.42 ± 0.07, p = 0.71). The symptoms of COPD were significantly improved, but the correlations between the improvement of symptoms and spirometry FEV1 and FEV1/FVC were low (R = 0.1 and -0.01, respectively). The differences in blood gasses and blood tests were insignificant. All but one EIT-based regional lung function parameter were significantly improved after hospitalization. The results highly correlated with the patient-reported outcome assessment (R > 0.6, p < 0.001). The overall acceptability score of EIT measurement for both attending physicians and patients was high (4.1 ± 0.8 for physicians, 4.5 ± 0.5 for patients out of 5). These results demonstrated that it was feasible and acceptable to use EIT as an objective bedside evaluation tool for COPD treatment efficacy.

9.
Physiol Meas ; 45(4)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38479002

RESUMO

Objective. This study aims to explore the possibility of using electrical impedance tomography (EIT) to assess pursed lips breathing (PLB) performance of patients with chronic obstructive pulmonary disease (COPD).Methods. 32 patients with COPD were assigned equally to either the conventional group or the EIT guided group. All patients were taught to perform PLB by a physiotherapist without EIT in the conventional group or with EIT in the EIT guided group for 10 min. The ventilation of all patients in the final test were continuously monitored using EIT and the PLB performances were rated by another physiotherapist before and after reviewing EIT. The global and regional ventilation between two groups as well as between quite breathing (QB) and PLB were compared and rating scores with and without EIT were also compared.Results.For global ventilation, the inspiratory depth and the ratio of expiratory-to-inspiratory time during PLB was significantly larger than those during QB for both group (P< 0.001). The inspiratory depth and the ratio of expiratory-to-inspiratory time during PLB in the EIT guided group were higher compared to those in the conventional group (P< 0.001), as well as expiratory flow expiratory uniformity and respiratory stability were better (P< 0.001). For regional ventilation, center of ventilation significantly decreased during PLB (P< 0.05). The expiratory time constant during PLB in the EIT guided group was greater than that in the conventional group (P< 0.001). Additionally, Bland-Altman plots analysis suggested a high concordance between subjective rating and rating with the help of EIT, but the score rated after EIT observation significantly lower than that rated subjectively in both groups (score drop of -2.68 ± 1.1 in the conventional group and -1.19 ± 0.72 in the EIT guided group,P< 0.01).Conclusion.EIT could capture the details of PLB maneuver, which might be a potential tool to quantitatively evaluate PLB performance and thus assist physiotherapists to teach PLB maneuver to patients.


Assuntos
Lábio , Doença Pulmonar Obstrutiva Crônica , Humanos , Impedância Elétrica , Respiração , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Tomografia
10.
Huan Jing Ke Xue ; 45(3): 1512-1524, 2024 Mar 08.
Artigo em Chinês | MEDLINE | ID: mdl-38471866

RESUMO

It is important to explore the relationship between land use types and water quality to improve the surface water environment. Based on monthly water quality monitoring data from 16 nationally controlled surface water quality monitoring stations in Tianjin and land use data in 2021, GIS spatial analysis and mathematical and statistical methods were used to study the influence of land use types on surface water quality in buffer zones at different scales. The results showed that:① the land use types in the study area were mainly construction land, farmland, and water areas, which had significant effects on river water quality. Except for water temperature (WT) and pH, the farmland, construction land, and water areas were negatively correlated with each water quality indicator; forest land and grassland were positively correlated with dissolved oxygen (DO) and total nitrogen (TN) and negatively correlated with other water quality indicators. ② The water quality indicators showed obvious spatial differences in different seasons. The pH, DO and TN concentrations were higher in the dry season, whereas the permanganate index, ammonia nitrogen (NH4+-N), and total phosphorus (TP) concentrations were higher in the rainy season. ③ The results of the RDA analysis showed that the 800 m buffer zone land use had the greatest explanatory power for water quality changes in the dry season (50.4%), whereas the 3 000 m buffer zone land use could explain the water quality changes in the rainy season to the greatest extent (49.6%); from the average explanation rate of the dry and rainy seasons, the 3 000 m buffer zone was the best impact scale (50.0%) on water quality indicators in Tianjin. ④ The partial least squares regression (PLSR) analysis showed that the most important variables affecting surface water quality changes were construction land, farmland, and water areas. The predictive ability of the PLSR model of most water quality indicators was stronger in the dry season than that in the rainy season. In the dry season, all water quality indicators, except WT and pH, were most influenced by farmland. In the rainy season, construction land had the greatest influence on WT and NH4+-N concentrations, and the most important influencing factor for the remaining water quality indicators was still farmland. This study showed that the rational planning of land use types within 3 000 m of rivers or lakes was beneficial to improving the water quality of surface water.

11.
Phytomedicine ; 127: 155487, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38490078

RESUMO

AIM: To extend and form the "Grading of Recommendations Assessment, Development and Evaluation in Traditional Chinese Medicine" (GRADE-TCM). METHODS: Methodologies were systematically reviewed and analyzed concerning evidence-based TCM guidelines worldwide. A survey questionnaire was developed based on the literature review and open-end expert interviews. Then, we performed expert consensus, discussion meeting, opinion collection, external examination, and the GRADE-TCM was formed eventually. RESULTS: 265 Chinese and English TCM guidelines were included and analyzed. Five experts completed the open-end interviews. Ten methodological entries were summarized, screened and selected. One round of consensus was conducted, including a total of 22 experts and 220 valid questionnaire entries, concerning 1) selection of the GRADE, 2) GRADE-TCM upgrading criteria, 3) GRADE-TCM evaluation standard, 4) principles of consensus and recommendation, and 5) presentation of the GRADE-TCM and recommendation. Finally, consensus was reached on the above 10 entries, and the results were of high importance (with voting percentages ranging from 50 % to 81.82 % for "very important" rating) and strong reliability (with the Cr ranging from 0.93 to 0.99). Expert discussion meeting (with 40 experts), opinion collection (in two online platforms) and external examination (with 14 third-party experts) were conducted, and the GRADE-TCM was established eventually. CONCLUSION: GRADE-TCM provides a new extended evidence-based evaluation standard for TCM guidelines. In GRADE-TCM, international evidence-based norms, characteristics of TCM intervention, and inheritance of TCM culture were combined organically and followed. This is helpful for localization of the GRADE in TCM and internationalization of TCM guidelines.


Assuntos
Medicina Baseada em Evidências , Medicina Tradicional Chinesa , Medicina Tradicional Chinesa/métodos , Reprodutibilidade dos Testes , Inquéritos e Questionários
12.
Diabetes Obes Metab ; 26(6): 2176-2187, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38419419

RESUMO

AIMS: To assess the excess risk of cardiovascular disease (CVD) associated with different criteria for metabolic health, and the interplay of body size, insulin sensitivity and metabolic health with CVD risk. MATERIALS AND METHODS: We conducted a prospective study involving 115 638 participants from the China Cardiometabolic Disease and Cancer Cohort (4C) Study. Metabolic health was defined using three different definitions: (1) insulin sensitivity defined by homeostatic model assessment of insulin resistance index; (2) absence of metabolic syndrome according to the National Cholesterol Education Program Adult Treatment Panel III criteria; and (3) simultaneous absence of metabolic abnormalities (diabetes, hypertension, dyslipidaemia). The primary endpoint was a composite of incident CVD events comprising the first occurrence of myocardial infarction, stroke, heart failure, or cardiovascular death. RESULTS: During a mean 3.61-year follow-up period, obese individuals with insulin sensitivity (multivariable-adjusted hazard ratio [HR] 1.69, 95% confidence interval [CI] 1.37-2.08), or without metabolic syndrome (HR 1.46, 95% CI 1.13-1.89) still exhibited increased CVD risks, when compared to their normal-weight counterparts. Otherwise, those with obesity but simultaneous absence of metabolic abnormalities demonstrated similar CVD risk compared to normal-weight individuals (HR 0.91, 95% CI 0.53-1.59). CVD risk increased with the number of abnormalities across body mass index categories, regardless of insulin sensitivity. CONCLUSIONS: This study emphasizes the need for refined definitions of metabolic health and advocates for meticulous screening for metabolic abnormalities to reduce cardiovascular risks, even in individuals with normal weight and insulin sensitivity.


Assuntos
Tamanho Corporal , Doenças Cardiovasculares , Resistência à Insulina , Síndrome Metabólica , Obesidade , Humanos , Masculino , Feminino , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/etiologia , China/epidemiologia , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto , Síndrome Metabólica/epidemiologia , Síndrome Metabólica/complicações , Obesidade/complicações , Obesidade/epidemiologia , Fatores de Risco , Idoso , Neoplasias/epidemiologia , Estudos de Coortes , Seguimentos , População do Leste Asiático
13.
Heliyon ; 10(3): e25405, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38352735

RESUMO

Pneumothorax is an emergency in thoracic surgeries and respiratory medicine. A technique is warranted for real-time monitoring of pneumothorax at the bedside so that rapid diagnosis and timely intervention can be achieved. We report herein a case in which electrical impedance tomography (EIT) was employed at the bedside to monitor lung ventilation of a patient with spontaneous pneumothorax during treatment. It was found that the affected side/healthy side ventilation ratio and global inhomogeneity were strongly correlated with the severity of pneumothorax. The use of EIT allowed intuitive observation of the effect of pneumothorax on ventilation, which helped the doctors make immediate diagnosis and intervention. After timely and successful treatment, the patient was discharged. This is the first case reporting a complete therapeutic course of spontaneous pneumothorax assessed with EIT. Our case demonstrated that EIT could monitor regional ventilation loss of the affected side of pneumothorax patients at the bedside, and dynamically assess the treatment effect of pneumothorax, which provides an important imaging basis for clinical pneumothorax treatment.

14.
Physiol Meas ; 45(2)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38266301

RESUMO

Objective.Wearable electrical impedance tomography (EIT) can be used to monitor regional lung ventilation and perfusion at the bedside. Due to its special system architecture, the amplitude of the injected current is usually limited compared to stationary EIT system. This study aims to evaluate the performance of current injection patterns with various low-amplitude currents in healthy volunteers.Approach.A total of 96 test sets of EIT measurement was recorded in 12 healthy subjects by employing adjacent and opposite current injection patterns with four amplitudes of small current (i.e. 1 mA, 500 uA, 250 uA and 125 uA). The performance of the two injection patterns with various currents was evaluated in terms of signal-to-noise ratio (SNR) of thorax impedance, EIT image metrics and EIT-based clinical parameters.Main results.Compared with adjacent injection, opposite injection had higher SNR (p< 0.01), less inverse artifacts (p< 0.01), and less boundary artifacts (p< 0.01) with the same current amplitude. In addition, opposite injection exhibited more stable EIT-based clinical parameters (p< 0.01) across the current range. For adjacent injection, significant differences were found for three EIT image metrics (p< 0.05) and four EIT-based clinical parameters (p< 0.01) between the group of 125 uA and the other groups.Significance.For better performance of wearable pulmonary EIT, currents greater than 250 uA should be used in opposite injection, 500 uA in adjacent one, to ensure a high level of SNR, a high quality of reconstructed image as well as a high reliability of clinical parameters.


Assuntos
Pulmão , Dispositivos Eletrônicos Vestíveis , Humanos , Impedância Elétrica , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Tomografia/métodos
15.
Physiol Meas ; 45(1)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38176102

RESUMO

Objective.The aim of the present study was to evaluate the influence of one-sided pulmonary nodule and tumour on ventilation distribution pre- and post- partial lung resection.Approach.A total of 40 consecutive patients scheduled for laparoscopic lung parenchymal resection were included. Ventilation distribution was measured with electrical impedance tomography (EIT) in supine and surgery lateral positions 72 h before surgery (T1) and 48 h after extubation (T2). Left lung to global ventilation ratio (Fl), the global inhomogeneity index (GI), standard deviation of regional ventilation delay (RVDSD) and pendelluft amplitude (Apendelluft) were calculated to assess the spatial and temporal ventilation distribution.Main results.After surgery (T2), ventilation at the operated chest sides generally deteriorated compared to T1 as expected. For right-side resection, the differences were significant at both supine and left lateral positions (p< 0.001). The change of RVDSDwas in general more heterogeneous. For left-side resection, RVDSDwas worse at T2 compared to T1 at left lateral position (p= 0.002). The other EIT-based parameters showed no significant differences between the two time points. No significant differences were observed between supine and lateral positions for the same time points respectively.Significance.In the present study, we found that the surgery side influenced the ventilation distribution. When the resection was performed on the right lung, the postoperative ipsilateral ventilation was reduced and the right lung ratio fell significantly. When the resection was on the left lung, the ventilation delay was significantly increased.


Assuntos
Laparoscopia , Tomografia , Humanos , Tomografia/métodos , Respiração , Pulmão/cirurgia , Tomografia Computadorizada por Raios X , Impedância Elétrica , Ventilação Pulmonar
16.
J Sci Food Agric ; 104(6): 3749-3756, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38234140

RESUMO

BACKGROUND: Laboratory scale experiments have shown that curdlan and gellan gum gelled together as curdlan/gellan gum (CG) hybrid gels showed better gel properties than the individual curdlan and gellan gum. In this study, CG and black wolfberry anthocyanin (BWA), CG and maltitol (ML) hybrid gels were constructed using CG hybrid gel as matrix. The effects of BWA or ML on the gel properties and microstructure of CG hybrid gels were investigated and a confectionery gel was developed. RESULTS: The presence of BWA increased the storage modulus (G') value of CG at 0.1 Hz, whereas ML had little effect on the G' value of CG. The addition of BWA (5 g L-1 ) and ML (0.3 mol L-1 ) increased the melting and gelling temperatures of CG hybrid gels to 42.4 °C and 34.1 °C and 44.2 °C and 33.2 °C, respectively. Meanwhile, the relaxation time T22 in CG-ML and CG-BWA hybrid gels was reduced to 91.96 and 410.27 ms, indicating the strong binding between BWA and CG, ML and CG. The hydrogen bond interaction between BWA or ML and CG was confirmed by the shift in the hydroxyl stretching vibration peak. Moreover, the microstructures of CG-ML and CG-BWA hybrid gels were denser than that of CG. In addition, confectionery gel containing CG-BWA-ML has good chewing properties. CONCLUSION: These results indicated that the incorporation of BWA or ML could improve the structure of CG hybrid gels and assign a sustainability potential for the development of confectionery gels based on CG complex. © 2024 Society of Chemical Industry.


Assuntos
Lycium , Maltose/análogos & derivados , Álcoois Açúcares , beta-Glucanas , Antocianinas , Polissacarídeos Bacterianos/química , Géis/química , Reologia
17.
Environ Technol ; 45(11): 2196-2204, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36606665

RESUMO

This study aims to explore the influence mechanism of ammonium nitrate produced by ozone denitrification on the crystallisation of ammonium sulfate, a by-product of ammonia desulfurisation. The laser method was used to study the influence of ammonium nitrate on the solubility and metastable zone width of ammonium sulfate. An experiment on the influence of ammonium nitrate on the particle size of ammonium sulfate was designed, and the influence mechanism was explored through scanning electron microscopy and X-ray diffraction. The findings showed that the addition of ammonium nitrate increased the size and aspect ratio of ammonium sulfate crystals. The addition of ammonium nitrate inhibited the dissolution of ammonium sulfate and widened its metastable zone. The addition of ammonium nitrate covered the active sites of crystal nucleus growth, which inhibited the formation of crystal nuclei to a certain extent, and crystal growth dominated the crystallisation process. Moreover, the addition of ammonium nitrate induced the preferred orientation of the specific crystal plane of ammonium sulfate, and the addition of a small concentration of ammonium nitrate decreased the crystallinity of ammonium sulfate. The research results can provide a reference for crystallisation optimisation and quality improvement of ammonium sulfate in the ammonia desulfurisation process.


Assuntos
Amônia , Compostos de Amônio , Sulfato de Amônio , Cristalização , Nitratos/química , Compostos de Amônio/química
18.
Dysphagia ; 39(2): 255-266, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37584721

RESUMO

To assess the severity and timing of penetration and aspiration (PA) of severe dysphagia after lateral medullary syndrome (LMS) and its association with temporal characteristics. We performed videofluoroscopic swallowing studies (VFSS) in 48 patients with LMS and severe dysphagia and 26 sex- and age-matched healthy subjects. The following temporal measures were compared between groups: velopharyngeal closure duration (VCD); hyoid bone movement duration (HMD); laryngeal vestibular closure duration (LCD); upper esophageal sphincter (UES) opening duration (UOD); stage transition duration (STD) and the interval between laryngeal vestibular closure and UES opening (LC-UESop). The association between temporal measures and Penetration-Aspiration Scale (PAS) scores was analyzed. Differences in timing measures were compared between subgroups (safe swallows, and swallows with PA events during and after the swallow). PAS scores ≥ 3 were seen in 48% of swallows (4% occuring before, 35% occurred during and 61% after the swallow) from the LMS patients. Significantly longer STD and LC-UESop were found in the patients compared to the healthy subjects (p < 0.05). Significant negative correlations with PA severity were found for HMD, LCD, and UOD. Short UOD was the strongest predictor with an area under the receiver-operating-characteristic curve of 0.66. UOD was also significantly shorter in cases of PA after the swallow (p < 0.01). Patients with LMS involving severe dysphagia exhibit a high frequency of PA (mostly during and after swallowing). PA events were associated with shorter UOD, HMD, and LCD. Notably, shortened UOD appears to be strongly associated with PA.


Assuntos
Transtornos de Deglutição , Síndrome Medular Lateral , Humanos , Transtornos de Deglutição/etiologia , Síndrome Medular Lateral/complicações , Deglutição , Aspiração Respiratória/etiologia , Fluoroscopia
19.
J Gene Med ; 26(1): e3592, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37726168

RESUMO

BACKGROUND: Plakophilin 2 gene (PKP2) has been revealed to be differentially expressed in various cancer types and is correlated with prognosis. However, the role of PKP2 in colon adenocarcinoma remains indistinct. METHODS: Differences in transcriptional expression of PKP2 between colon adenocarcinoma tissues and normal adjacent tissues were acquired from the publicly available dataset-the Cancer Genome Atlas. A receiver operating curve (ROC) was constructed to differentiate colon adenocarcinoma tissues from adjacent normal tissues. The Kaplan-Meier plot method was performed to evaluate the effect of PKP2 on survival. The correlation between mRNA expression of PKP2 and immune infiltrating was determined by the Tumor Immune Estimation Resource and Tumor-Immune System Interaction databases. RESULTS: The expression of PKP2 in colon adenocarcinoma tissues was significantly downregulated compared with corresponding adjacent normal tissues. Decreased PKP2 mRNA expression was associated with lymph node metastases and advanced pathological stage. The ROC curve analysis indicated that with a cutoff value of 6.034, the sensitivity and specificity for PKP2 differentiating the colon adenocarcinoma tissues from the adjacent normal tissues were 90.2 and 66.5% respectively. Kaplan-Meier plot survival analysis revealed that colon adenocarcinoma patients with low-PKP2 had a worse prognosis than those with high-PKP2 (68.2 vs. 101.4 months, p = 0.028). Correlation analysis showed that mRNA expression of PKP2 was correlative with immune infiltrates. CONCLUSIONS: Downregulated PKP2 is significantly correlated with unfavorable immune infiltrating and survival in colon adenocarcinoma. This research indicates that PKP2 can be selected as a novel biomarker of potential immunotherapy targets and unfavorable prognosis in colon adenocarcinoma.


Assuntos
Adenocarcinoma , Neoplasias do Colo , Humanos , Adenocarcinoma/genética , Neoplasias do Colo/diagnóstico , Neoplasias do Colo/genética , Imunoterapia , Placofilinas/genética , RNA Mensageiro/genética
20.
Cancer Biother Radiopharm ; 39(1): 55-63, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37883659

RESUMO

Objective: The objective of this study was to investigate the feasibility of 1-d 68Ga-DOTA-FAPI-04 and 18F-FDG (2-deoxy-2[18F]fluoro-d-glucose) positron emission tomography/computed tomography (PET/CT) for detecting ovarian cancer recurrence and metastasis. Materials and Methods: Fifty-two patients who underwent 18F-FDG and 68Ga-DOTA-FAPI-04 PET/CT were divided into 1- and 2-d groups. Image acquisition, injection time, and total waiting time were compared. For the 68Ga-DOTA-FAPI-04 PET/CT scans, low-dose CT scans and low injection dosages were employed, and total radiation dose was assessed for both protocols. The comparative analysis included assessment of patient-based detection rates and lesion-based diagnostic efficacy. Results: The total waiting time was significantly shorter in the 1-d group than in the 2-d group (p = 0.000). The radiation doses stemming from internal radiation and external radiation between the groups showed no differences (p = 0.151 vs. 0.716). In the patient-based analysis, the detection rates for local recurrence, peritoneal, lymph node, and other metastases were not significantly different in both protocols (p ∈ [0.351, 1.000]). For the lesion-based analysis, no differences were noted in terms of sensitivity, specificity, positive predictive value, negative predictive value, and accuracy (p ∈ [0.371, 1.000]). Conclusions: The 1-d PET/CT protocol reduced waiting time and exhibited equivalent detectability compared with the 2-d protocol, suggesting its clinical value.


Assuntos
Compostos Heterocíclicos com 1 Anel , Neoplasias Ovarianas , Quinolinas , Humanos , Feminino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Radioisótopos de Gálio , Estudos de Viabilidade , Neoplasias Ovarianas/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA