Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Am J Cardiol ; 208: 53-59, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37812867

RESUMO

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) use for circulatory support in cardiogenic shock results in increased left ventricular (LV) afterload. The use of concomitant Impella or intra-aortic balloon pump (IABP) have been proposed as adjunct devices for LV unloading. The authors sought to compare head-to-head efficacy and safety outcomes between the 2 LV unloading strategies. We conducted a search of Medline, EMBASE, and Cochrane databases to identify studies comparing the use of Impella to IABP in patients on VA-ECMO. The primary outcome of interest was in-hospital mortality. The secondary outcomes included transition to durable LV assist devices/cardiac transplantation, stroke, limb ischemia, need for continuous renal replacement therapy, major bleeding, and hemolysis. Pooled risk ratios (RRs) with 95% confidence interval and heterogeneity statistic I2 were calculated using a random-effects model. A total of 7 observational studies with 698 patients were included. Patients on VA-ECMO unloaded with Impella vs IABP had similar risk of short-term all-cause mortality, defined as either 30-day or in-hospital mortality- 60.8% vs 64.9% (RR 0.93 [0.71 to 1.21], I2 = 71%). No significant difference was observed in transition to durable LV assist devices/cardiac transplantation, continuous renal replacement therapy initiation, stroke, or limb ischemia between the 2 strategies. However, the use of VA-ECMO with Impella was associated with increased risk of major bleeding (57.2% vs 39.7%) (RR 1.66 [1.12 to 2.44], I2 = 82%) and hemolysis (31% vs 7%) (RR 4.61 [1.24 to 17.17], I2 = 66%) compared with VA-ECMO, along with IABP. In conclusion, in patients requiring VA-ECMO for circulatory support, the concomitant use of Impella or IABP had comparable short-term mortality. However, Impella use was associated with increased risk of major bleeding and hemolysis.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Acidente Vascular Cerebral , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Hemólise , Choque Cardiogênico , Balão Intra-Aórtico/métodos , Coração Auxiliar/efeitos adversos , Acidente Vascular Cerebral/etiologia , Hemorragia/etiologia , Resultado do Tratamento
2.
Front Cardiovasc Med ; 9: 929472, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35911530

RESUMO

Background: Aorto-ostial interventions are challenging due to the limitations of contemporary equipment, imprecise ostial demarcation, and problematic ostial lesion characteristics. Suboptimal stent placement is common and portends worse clinical outcomes. Procedural and long-term outcomes of the bumper wire technique with intravascular ultrasound (IVUS) assessment have not been investigated. Methods: A single-center retrospective study was conducted. Patients who underwent ostial lesion percutaneous coronary intervention (PCI) with the bumper wire technique between January 2019 and September 2020 were identified. The primary endpoint was to determine the geographic miss rate defined by inadequate ostial coverage or excess stent protrusion of > 2 mm by IVUS or angiography. The secondary endpoint was target lesion failure (TLF) at 6 months after PCI, defined as the composite of cardiovascular death, target vessel myocardial infarction (MI), and target lesion revascularization. Results: In total, 45 patients were identified. The average age was 71.7 years old, and 85.4% were men. Indication for PCI was acute coronary syndrome in about a third of patients. Twenty-six patients had left main ostial lesions and 19 patients had right coronary artery ostial lesions. Geographic miss was detected in two patients (4.4%): one patient (2.2%) had excess proximal stent protrusion and one patient (2.2%) had an ostial miss. Six patients were lost to follow-up. TLF, stroke, or major bleeding were not observed in any of the patients. Conclusion: The bumper wire technique is safe and efficient with low rates of geographic miss or adverse clinical outcomes. This is the first study to confirm precise aorto-ostial stent implantation with the bumper wire technique using IVUS confirmation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA