Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
G Ital Nefrol ; 41(2)2024 Apr 29.
Artigo em Italiano | MEDLINE | ID: mdl-38695226

RESUMO

In patients on peritoneal dialysis, the cutaneous emergency (exit-site) represents a potential access route to the peritoneum; consequently, it can become a site for microbial infections. These infections, initially localized to the exit-site, may spread to the peritoneum causing peritonitis, which is the most common cause of drop-out from peritoneal dialysis and transition to hemodialysis. Peritoneal catheters have dacron caps which have the function of counteracting the traction of the catheter itself and at the same time acting as a barrier for microorganisms, preventing the spread towards the peritoneum. Despite this, the same dacron cap can represent a sort of nest for microorganisms to colonize and, with the formation of a biofilm that facilitates their proliferation, make the same organisms impervious to antibiotic therapy and even resistance to them. The most effective tool for monitoring the health status of the exit-site is represented by the objective examination. This examination, through the use of well-defined scales, helps to provide a pathological score of the exit, facilitating the implementation of necessary precautions. In the presence of recurrent exit-site infections, from both Gram positive and Gram negative bacteria, minimally invasive surgical therapy is a valid approach to break this vicious circle. It helps avoid subjecting the patient to the removal of the peritoneal catheter, temporary transition to hemodialysis with the insertion of a central venous catheter, and subsequent repositioning of another peritoneal catheter. We propose the case of a recurrent Staphylococcus Aureus infection resolved after cuff shaving of the exit-site.


Assuntos
Infecções Relacionadas a Cateter , Cateteres de Demora , Diálise Peritoneal , Recidiva , Humanos , Diálise Peritoneal/efeitos adversos , Diálise Peritoneal/instrumentação , Infecções Relacionadas a Cateter/microbiologia , Infecções Relacionadas a Cateter/prevenção & controle , Infecções Relacionadas a Cateter/etiologia , Cateteres de Demora/efeitos adversos , Cateteres de Demora/microbiologia , Peritonite/microbiologia , Peritonite/etiologia , Masculino
2.
G Ital Nefrol ; 40(3)2023 Jun 29.
Artigo em Italiano | MEDLINE | ID: mdl-37427906

RESUMO

Among the various problems associated with peritoneal dialysis, besides infectious causes, the risk of catheter malfunction plays a significant role in conditioning the continuation of the method, accounting for up to 15-18% of the total causes of dialysis drop-out. When non-invasive maneuvers, such as the use of laxatives to stimulate intestinal peristalsis or heparin and/or urokinase have no effect, videolaparoscopy is the only method that directly detects the precise causes of peritoneal catheter malfunction. Those found are, with decreasing frequency, the winding of the catheter between the intestinal loops and the omentum (wrapping), the dislocation of the catheter, the combination of wrapping and dislocation, the occlusion of the catheter by a fibrin plug, the adhesions between the intestine and abdominal wall, the occlusion of the catheter by epiploic appendages or adnexal tissue and, occasionally, the presence of a new formation of endoperitoneal tissue enveloping and obstructing the peritoneal catheter. We report the case of a young patient of African ethnicity who, only five days after catheter placement, experienced malfunction. A videolaparoscopy revealed wrapping with invagination of omental tissue inside the catheter. After omental debridement, a proper peritoneal cavity washout with heparin was resumed, and after a couple of weeks, APD was initiated. About a month later, a new malfunction without signs of coprostasis or problems with the abdominal radiogram was observed. However, a subsequent catheterography confirmed the blockage of drainage. This was followed by another catheterography and omentopexy, with definitive solution of the Tenckhoff malfunction.


Assuntos
Laparoscopia , Cavidade Peritoneal , Humanos , Cateterismo/métodos , Laparoscopia/métodos , Cateteres de Demora/efeitos adversos , Heparina
3.
Surg Endosc ; 35(12): 7142-7153, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33492508

RESUMO

BACKGROUND: Anastomotic leakage (AL) is one of the dreaded complications following surgery in the digestive tract. Near-infrared fluorescence (NIRF) imaging is a means to intraoperatively visualize anastomotic perfusion, facilitating fluorescence image-guided surgery (FIGS) with the purpose to reduce the incidence of AL. The aim of this study was to analyze the current practices and results of NIRF imaging of the anastomosis in digestive tract surgery through the EURO-FIGS registry. METHODS: Analysis of data prospectively collected by the registry members provided patient and procedural data along with the ICG dose, timing, and consequences of NIRF imaging. Among the included upper-GI, colorectal, and bariatric surgeries, subgroup analysis was performed to identify risk factors associated with complications. RESULTS: A total of 1240 patients were included in the study. The included patients, 74.8% of whom were operated on for cancer, originated from 8 European countries and 30 hospitals. A total of 54 surgeons performed the procedures. In 83.8% of cases, a pre-anastomotic ICG dose was administered, and in 60.1% of cases, a post-anastomotic ICG dose was administered. A significant difference (p < 0.001) was found in the ICG dose given in the four pathology groups registered (range: 0.013-0.89 mg/kg) and a significant (p < 0.001) negative correlation was found between the ICG dose and BMI. In 27.3% of the procedures, the choice of the anastomotic level was guided by means of NIRF imaging which means that in these cases NIRF imaging changed the level of anastomosis which was first decided based on visual findings in conventional white light imaging. In 98.7% of the procedures, the use of ICG partly or strongly provided a sense of confidence about the anastomosis. A total of 133 complications occurred, without any statistical significance in the incidence of complications in the anastomoses, whether they were ICG-guided or not. CONCLUSION: The EURO-FIGS registry provides an insight into the current clinical practice across Europe with respect to NIRF imaging of anastomotic perfusion during digestive tract surgery.


Assuntos
Verde de Indocianina , Cirurgia Assistida por Computador , Anastomose Cirúrgica/efeitos adversos , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/etiologia , Humanos , Perfusão , Sistema de Registros
4.
Chir Ital ; 54(1): 51-3, 2002.
Artigo em Italiano | MEDLINE | ID: mdl-11942009

RESUMO

The authors report on their experience with the treatment of 34 consecutive patients suffering from perforated peptic ulcer with peritonitis. All patients has been treated by the laparoscopic approach using sutures according to the Graham-Steele technique and omental plication. Irrigation, suction of the entire abdominal cavity with isotonic sodium chloride solution and drainage completed the procedure. In three cases, after an initial laparoscopic operation, we converted to laparotomy because of a large or unusually positioned ulcer. The morbidity rate was low and one patient died of myocardial infarction. The mean hospital stay was seven days. The method, which requires good laparoscopic experience, is simple, allows thorough toilette, has a low morbidity and is safe for the patient.


Assuntos
Úlcera Duodenal/complicações , Laparoscopia , Úlcera Péptica Perfurada/cirurgia , Úlcera Gástrica/complicações , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Laparotomia , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Omento/cirurgia , Técnicas de Sutura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA