Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Clin Neuroradiol ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39023541

RESUMO

BACKGROUND: The comparative efficacy and safety of first-generation flow diverters (FDs), Pipeline Embolization Device (PED) (Medtronic, Irvine, California), Silk (Balt Extrusion, Montmorency, France), Flow Re-direction Endoluminal Device (FRED) (Microvention, Tustin, California), and Surpass Streamline (Stryker Neurovascular, Fremont, California), is not directly established and largely inferred. PURPOSE: This study aimed to compare the efficacy of different FDs in treating sidewall ICA intracranial aneurysms. METHODS: We conducted a retrospective review of prospectively maintained databases from eighteen academic institutions from 2009-2016, comprising 444 patients treated with one of four devices for sidewall ICA aneurysms. Data on demographics, aneurysm characteristics, treatment outcomes, and complications were analyzed. Angiographic and clinical outcomes were assessed using various imaging modalities and modified Rankin Scale (mRS). Propensity score weighting was employed to balance confounding variables. The data analysis used Kaplan-Meier curves, logistic regression, and Cox proportional-hazards regression. RESULTS: While there were no significant differences in retreatment rates, functional outcomes (mRS 0-1), and thromboembolic complications between the four devices, the probability of achieving adequate occlusion at the last follow-up was highest in Surpass device (HR: 4.59; CI: 2.75-7.66, p < 0.001), followed by FRED (HR: 2.23; CI: 1.44-3.46, p < 0.001), PED (HR: 1.72; CI: 1.10-2.70, p = 0.018), and Silk (HR: 1.0 ref. standard). The only hemorrhagic complications were with Surpass (1%). CONCLUSION: All the first-generation devices achieved good clinical outcomes and retreatment rates in treating ICA sidewall aneurysms. Prospective studies are needed to explore the nuanced differences between these devices in the long term.

2.
Surg Neurol Int ; 14: 105, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37025535

RESUMO

Background: The ophthalmic segment of the internal carotid artery (ICA) represents a common site for cerebral aneurysms. However, aneurysms of the ophthalmic artery (OphA) itself represent rare lesions and have been associated with trauma and flow-related lesions such as arteriovenous fistulas or malformations. Here, we explore clinical and radiological features of four patients managed for five proper ophthalmic artery aneurysms (POAAs). Methods: Patients undergoing diagnostic cerebral angiogram (DCA) between January 2018 and November 2021 with newly or previously identified POAA were retrospectively reviewed. Clinical and radiological data were analyzed to identify common and unique features. Results: Four patients with identification of five POAA were identified. Three patients suffered traumatic brain injury with subsequent identification of POAA on DCA. Patient 1 presented with a traumatic carotid-cavernous-sinus fistula requiring transvenous coil embolization and second stage flow diversion of the ICA. Patient 2 suffered a gunshot wound with ICA compromise, ethmoidal dural arteriovenous fistula (dAVF) development with rapid growth of two POAAs eventually requiring Onyx embolization. Patient 3 was assaulted and DCA showed a POAA without any other cerebrovascular pathology. Patient 4 had undergone N-butyl cyanoacrylate embolization of an ethmoidal dAVF 13 years ago with the feeding OphA carrying a large POAA. Re-DCADCA was performed for a newly developed and unrelated transverse-sigmoid-sinus dAVF. Conclusion: Management of POAAs poses a challenge to neurovascular surgeons since POAAs inherit a risk for visual deterioration or hemorrhage. DCA facilitates identification of coexisting cerebrovascular pathology. If clinically silent and not accompanied by cerebrovascular disease, observation appears reasonable.

3.
J Neurointerv Surg ; 15(e2): e277-e281, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36414389

RESUMO

BACKGROUND: Tenecteplase (TNK) is a genetically modified variant of alteplase (TPA) and has been established as a non-inferior alternative to TPA in acute ischemic stroke (AIS). Whether TNK exerts distinct benefits in large vessel occlusion (LVO) AIS is still being investigated. OBJECTIVE: To describe our first-year experience after a healthcare system-wide transition from TPA to TNK as the primary thrombolytic. METHODS: Patients with AIS who received intravenous thrombolytics between January 2020 and August 2022 were retrospectively reviewed. All patients with LVO considered for mechanical thrombectomy (MT) were included in this analysis. Spontaneous recanalization (SR) after TNK/TPA was a composite variable of reperfusion >50% of the target vessel territory on cerebral angiography or rapid, significant neurological recovery averting MT. Propensity score matching (PSM) was performed to compare SR rates between TNK and TPA. RESULTS: A total of 148 patients were identified; 51/148 (34.5%) received TNK and 97/148 (65.5%) TPA. The middle cerebral arteries M1 (60.8%) and M2 (29.7%) were the most frequent occlusion sites. Baseline demographics were comparable between TNK and TPA groups. Spontaneous recanalization was significantly more frequently observed in the TNK than in the TPA groups (unmatched: 23.5% vs 10.3%, P=0.032). PSM substantiated the observed SR rates (20% vs 10%). Symptomatic intracranial hemorrhage, 90-day mortality, and functional outcomes were similar. CONCLUSIONS: The preliminary experience from a real-world setting demonstrates the effectiveness and safety of TNK before MT. The higher spontaneous recanalization rates with TNK are striking. Additional studies are required to investigate whether TNK is superior to TPA in LVO AIS.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Ativador de Plasminogênio Tecidual/uso terapêutico , Tenecteplase/uso terapêutico , AVC Isquêmico/tratamento farmacológico , Estudos Retrospectivos , Fibrinolíticos/uso terapêutico , Trombectomia , Atenção à Saúde , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/cirurgia , Resultado do Tratamento , Terapia Trombolítica , Isquemia Encefálica/tratamento farmacológico , Isquemia Encefálica/cirurgia
4.
Surg Neurol Int ; 13: 364, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36128125

RESUMO

Background: With the drastically aging population in the U.S., chronic subdural hematomas (cSDHs) are projected to represent the most common neurosurgical diagnosis requiring treatment within the next two decades. There is lack of contemporary outcome data in patients treated for nontraumatic and nonacute subdural hematoma. We aim to portray current mortality rates, complication rates, length of stay, and costs associated with inpatient cSDH care. Methods: The Premier Health-care Database, Premier Inc., Charlotte/NC was queried for encounters October 2016-December 2020 with the ICD-10 diagnoses of nontraumatic nonacute subdural hematoma as the principal diagnosis among patients age ≥40 years. Per database in-hospital mortality is defined as mortality in an inpatient who is not discharged. Complications represent medical conditions not present on admission that affects mortality, length of stay, and costs within the database. Results: The query identified 14,136 inpatient encounters. Between October 2016 and December 2020, in-hospital mortality rates averaged 10.9% in the medical group (MG) and 3.6% in the surgical group (SG) (P < 0.001). Complication rates averaged between 8.9 % in the MG and 19.9% in the SG (P < 0.001). LOS averaged 3.0 days in the MG and 5.7 days in the SG (P < 0.001). Total costs averaged $ 10,233 in the MG and $ 26,658 in the SG. Conclusion: The standardized outcomes presented represent an objective benchmark of contemporary cSDH treatment outcomes in the U.S. With the projected substantial increase of cSDH cases within the next decades, new treatment strategies such as middle meningeal embolization need to be explored and outperform current outcome metrics.

5.
J Neurointerv Surg ; 14(7): 709-717, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34686574

RESUMO

INTRODUCTION: The Walrus balloon guide catheter (BGC) is a new generation of BGC, designed to eliminate conventional limitations during mechanical thrombectomy. OBJECTIVE: To report a multi-institutional experience using this BGC for proximal flow control (PFC) in the setting of carotid artery angioplasty/stenting (CAS) in elective (eCAS) and tandem strokes (tCAS). METHODS: Prospectively maintained databases at 8 North American centers were queried to identify patients with cervical carotid disease undergoing eCAS/tCAS with a Walrus BGC. RESULTS: 110 patients (median age 68, 64.6% male), 80 (72.7%) undergoing eCAS and 30 (27.3%) tCAS procedures, were included (median cervical carotid stenosis 90%; 46 (41.8%) with contralateral stenosis). Using a proximal flow-arrest technique in 95 (87.2%) and flow-reversal in 14 (12.8%) procedures, the Walrus was navigated into the common carotid artery successfully in all cases despite challenging arch anatomy (31, 28.2%), with preferred femoral access (103, 93.6%) and in monitored anesthesia care (90, 81.8%). Angioplasty and distal embolic protection devices (EPDs) were used in 91 (83.7%) and 58 (52.7%) procedures, respectively. tCAS led to a modified Thrombolysis in Cerebral Infarction 2b/3 in all cases. Periprocedural ischemic stroke (up to 30 days postoperatively) rate was 0.9% (n=1) and remote complications occurred in 2 (1.8%) cases. Last follow-up modified Rankin Scale score of 0-2 was seen in 95.3% of eCAS cohort, with no differences in complications in the eCAS subgroup between PFC only versus PFC and distal EPD (median follow-up 4.1 months). CONCLUSION: Walrus BGC for proximal flow control is safe and effective during eCAS and tCAS. Procedural success was achieved in all cases, with favorable safety and functional outcomes on short-term follow-up.


Assuntos
Estenose das Carótidas , Acidente Vascular Cerebral , Animais , Artéria Carótida Primitiva , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Catéteres/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Retrospectivos , Stents/efeitos adversos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia , Resultado do Tratamento , Morsas
6.
World Neurosurg ; 153: e195-e203, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34182180

RESUMO

BACKGROUND: Blood pressure monitoring is crucial during neuroendovascular procedures. Intraoperative hemodynamic instability is associated with complications, which underscores the importance of continuous monitoring. Although direct measurement with an intra-arterial catheter is the gold standard for determining arterial pressure, it is costly, time-consuming, and associated with complications. The novel ClearSight system offers a noninvasive technique for monitoring arterial pressure via a finger cuff. This study compared noninvasive arterial pressure measurements with the gold standard method. METHODS: Simultaneous recording of noninvasive and invasive arterial pressure was performed in patients undergoing neuroendovascular interventions. Both techniques were compared employing linear regression, Lin's correlation coefficient, Bland-Altman, and error grid analysis. RESULTS: The study enrolled 24 consecutive patients. The concordance correlation coefficient between both methods was 0.3526 (95% confidence interval [0.3134, 0.3906]) for mean arterial pressure and 0.4680 (95% confidence interval [0.4353, 0.4995]) and for systolic arterial pressure. The mean (SD) of the differences was 0.81 (17.86) mm Hg (95% limits of agreement [-52.52, 54.14]) for mean arterial pressure and 5.38 (14.64) mm Hg (95% limits of agreement [-45.12, 56.08]) for systolic arterial pressure. Error grid analysis demonstrated that the majority of measurements lie in regions with no or low risk for patients (mean arterial pressure, 71.0% and 24.4%; systolic arterial pressure, 59.2% and 25.8%). CONCLUSIONS: The ClearSight system provided accurate measurements of arterial blood pressure compared with invasive methods and within safe clinical parameters. This method may serve as a safe and reliable alternative for invasive blood pressure monitoring during neuroendovascular procedures.


Assuntos
Pressão Arterial , Monitores de Pressão Arterial , Procedimentos Endovasculares , Monitorização Hemodinâmica/métodos , Monitorização Intraoperatória/métodos , Procedimentos Neurocirúrgicos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Dedos , Monitorização Hemodinâmica/instrumentação , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação , Adulto Jovem
7.
Med J Armed Forces India ; 77(Suppl 1): S49-S56, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33612932

RESUMO

BACKGROUND: The explicit declaration of Entrustable Professional Activities (EPA) and milestones are an essential component of a competency based medical education curricula. The present study attempts to develop a portfolio framework to document them for adaptation in any healthcare professional education curriculum development. METHODS: A modified e-Delphi method was used after incorporation of a study group of medical education experts (MEDEX-G). Consensus was defined as 75% agreement. Both qualitative and quantitative data was collected and analysed to conduct three rounds of the Delphi. RESULTS: The draft template was prepared by the core faculty of medical education centre. The final template was approved by the experts after 03 iterations of anonymous online voting and presentation of summary results by the moderator. The final template lists out the milestones of each EPA separately with provision for expected expertise and level, suggestive teaching learning activities and assessments, reflections by the students and feedback by facilitator for each EPA. CONCLUSION: The MEDEX-G consensus template is an important development to encourage the adoption of portfolios in a competency based medical education curriculum. It can be freely adopted by various healthcare professional education bodies in various disciplines.

8.
J Neurointerv Surg ; 13(1): 91-95, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32487766

RESUMO

BACKGROUND: Currently, there are no large-scale studies in the neurointerventional literature comparing safety between transradial (TRA) and transfemoral (TFA) approaches for flow diversion procedures. This study aims to assess complication rates in a large multicenter registry for TRA versus TFA flow diversion. METHODS: We retrospectively analyzed flow diversion cases for cerebral aneurysms from 14 institutions from 2010 to 2019. Pooled analysis of proportions was calculated using weighted analysis with 95% CI to account for results from multiple centers. Access site complication rate and overall complication rate were compared between the two approaches. RESULTS: A total of 2,285 patients who underwent flow diversion were analyzed, with 134 (5.86%) treated with TRA and 2151 (94.14%) via TFA. The two groups shared similar patient and aneurysm characteristics. Crossover from TRA to TFA was documented in 12 (8.63%) patients. There were no access site complications in the TRA group. There was a significantly higher access site complication rate in the TFA cohort as compared with TRA (2.48%, 95% CI 2.40% to 2.57%, vs 0%; p=0.039). One death resulted from a femoral access site complication. The overall complications rate was also higher in the TFA group (9.02%, 95% CI 8.15% to 9.89%) compared with the TRA group (3.73%, 95% CI 3.13% to 4.28%; p=0.035). CONCLUSION: TRA may be a safer approach for flow diversion to treat cerebral aneurysms at a wide range of locations. Both access site complication rate and overall complication rate were lower for TRA flow diversion compared with TFA in this large series.


Assuntos
Procedimentos Endovasculares/tendências , Artéria Femoral/cirurgia , Aneurisma Intracraniano/cirurgia , Complicações Pós-Operatórias , Artéria Radial/cirurgia , Stents Metálicos Autoexpansíveis/tendências , Adulto , Idoso , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Cateterismo Periférico/tendências , Estudos de Coortes , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Artéria Radial/diagnóstico por imagem , Sistema de Registros , Estudos Retrospectivos , Stents Metálicos Autoexpansíveis/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
9.
J Neurointerv Surg ; 13(2): 153-158, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32611622

RESUMO

BACKGROUND: Flow diversion is a common endovascular treatment for cerebral aneurysms, but studies comparing different types of flow diverters are scarce. OBJECTIVE: To perform a propensity score matched cohort study comparing the Pipeline Embolization Device (PED) and Flow Redirection Intraluminal Device (FRED) for posterior circulation aneurysms. METHODS: Consecutive aneurysms of the posterior circulation treated at 25 neurovascular centers with either PED or FRED were collected. Propensity score matching was used to control for age, duration of follow-up imaging, adjunctive coiling, and aneurysm location, size, and morphology; previously ruptured aneurysms were excluded. The two devices were compared for the following outcomes: procedural complications, aneurysm occlusion, and functional outcome. RESULTS: A total of 375 aneurysms of the posterior circulation were treated in 369 patients. The PED was used in 285 (77.2%) and FRED in 84 (22.8%) procedures. Aneurysms treated with the PED were more commonly fusiform and larger than those treated with FRED. To account for these important differences, propensity score matching was performed resulting in 33 PED and FRED unruptured aneurysm pairs. No differences were found in occlusion status and neurologic thromboembolic or hemorrhagic complications between the two devices. The proportion of patients with favorable functional outcome was higher with FRED (100% vs 87.9%, p=0.04). CONCLUSION: Comparative analysis of PED and FRED for the treatment of unruptured posterior circulation aneurysms did not identify significant differences in aneurysm occlusion or neurologic complications. Variations in functional outcomes warrant additional investigations.


Assuntos
Aneurisma Roto/terapia , Prótese Vascular/normas , Embolização Terapêutica/normas , Aneurisma Intracraniano/terapia , Pontuação de Propensão , Stents Metálicos Autoexpansíveis/normas , Adulto , Idoso , Aneurisma Roto/diagnóstico por imagem , Estudos de Coortes , Embolização Terapêutica/métodos , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
10.
World Neurosurg ; 142: e445-e452, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32688033

RESUMO

BACKGROUND: Dual antiplatelet therapy consisting of aspirin and clopidogrel is the standard of care for neurointerventional stenting and flow diversion. Platelet function testing has been increasingly performed to identify patients with a hypo- or hyper-response to clopidogrel. Ticagrelor has been a popular alternative antiplatelet agent for such patients. We assessed the role of platelet function testing in patients receiving ticagrelor and undergoing stenting or flow diversion. METHODS: The data from patients who had undergone stent-assisted coiling or Pipeline flow diversion of a cerebral aneurysm with ticagrelor therapy at any point during their treatment course from May 2017 to August 2019 at a single academic institution in the United States were retrospectively reviewed. Platelet function testing was used to determine the P2Y12 reactive units (PRUs), and the results were correlated with the procedural complications. RESULTS: A total of 28 patients with 29 aneurysms were treated while receiving ticagrelor. Of the 29 aneurysms, 16 (55.2%) were treated with flow diversion and 13 (44.8%) with stent-assisted coiling. Four thromboembolic complications (13.8%) and no hemorrhagic complications developed. Of the 8 patients with ≥1 PRU value >100, 4 (50%) had experienced a thromboembolic complication. The patients without a PRU value >100 did not experience any complications. CONCLUSION: A risk of thromboembolic complications exists for patients receiving ticagrelor, which correlated with the PRUs in the present preliminary study. The findings from the present study suggest that the safe PRU range for patients receiving ticagrelor should be shifted to 0-100, which is lower than that of clopidogrel, thought to be 60-210. Further validation of the optimal PRU range for patients receiving ticagrelor is necessary.


Assuntos
Aneurisma Intracraniano/tratamento farmacológico , Aneurisma Intracraniano/cirurgia , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Receptores Purinérgicos P2Y12 , Stents Metálicos Autoexpansíveis/tendências , Ticagrelor/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
Neurosurgery ; 87(6): 1252-1261, 2020 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-32629474

RESUMO

BACKGROUND: The Pipeline Embolization Device (PED; Medtronic) has been used off-label for the treatment of challenging posterior circulation aneurysms. Data on this modality are primarily limited to small retrospective single-center series. OBJECTIVE: To assess safety and efficacy of this treatment by establishing an international, multicenter collaboration. METHODS: Consecutive posterior circulation aneurysms treated with the PED from 2012 to 2019 across 11 neurovascular centers were retrospectively reviewed. Baseline demographics, aneurysm and treatment characteristics, complications, occlusion status, and functional outcome were assessed. RESULTS: There were 149 posterior circulation aneurysms treated with PED in 146 patients. A total of 24 (16.4%) patients presented with subarachnoid hemorrhage. Most aneurysms were dissecting/blister (36.2%) in morphology, followed by saccular (35.6%) and fusiform (28.2%). The most common locations were the vertebral (51.7%) and basilar arteries (22.8%). Complete or near-complete occlusion (>90%) was achieved in 90.9% of aneurysms at a median follow-up of 12 mo. Dissecting/blister aneurysms were most likely to occlude (P = .06). Symptomatic neurologic complications occurred in 9.4% of aneurysms, associated with larger size, ruptured presentation, presentations with brain stem compression, cranial nerve palsy, or stroke. Favorable functional outcome (modified Rankin Score 0-2) was achieved in 86.2% of patients. There were 6 fatalities of which 4 occurred in aneurysmal subarachnoid hemorrhage patients. CONCLUSION: This multicenter study shows that PED for the treatment of posterior circulation is preferentially used for the treatment of fusiform and dissecting/blister aneurysm morphologies. Despite the challenges presented by these less-common morphologies, flow diversion may be performed with a neurologic complication rate of about 10% and favorable long-term aneurysm occlusion rates.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Estudos de Coortes , Embolização Terapêutica/efeitos adversos , Seguimentos , Humanos , Aneurisma Intracraniano/epidemiologia , Aneurisma Intracraniano/terapia , Estudos Retrospectivos , Resultado do Tratamento
12.
World Neurosurg ; 141: e736-e742, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32535054

RESUMO

OBJECTIVE: Intraoperative imaging is critical in cerebrovascular surgery to assess the technical success of the operation. This case series aimed to evaluate the safety and efficacy of 3-dimensional rotational angiogram (3D-RA) in addition to 2-dimensional intraoperative angiography (2D-IOA) during cerebrovascular surgery in the hybrid operating room. METHODS: All consecutive patients who underwent open cerebrovascular surgery and intraoperative 2D-IOA with 3D-RA in a hybrid operating room at 2 academic centers between August 2018 and December 2019 were identified from a prospectively maintained institutional database. Medical charts and operative videos including intraoperative angiography were reviewed, and clinical and angiographic outcomes assessed. RESULTS: A total of 40 cerebrovascular surgeries in 39 patients (mean age, 53 ± 13 years; 51% female) were carried out with the addition of 3D-RA to 2D-IOA in the hybrid operating room. After 3D-RA in addition to 2D-IOA, 1 (2.5%) surgical alteration occurred in an aneurysm clipping. Other procedures were not altered with the addition of 3D-RA to 2D-IOA. There were no complications from the addition of 3D-RA to 2D-IOA. CONCLUSIONS: Using a combination of 3D-RA and 2D-IOA in the hybrid operating room may enhance the likelihood of achieving an optimal result when employing microsurgical cerebrovascular surgery and avoid unanticipated incomplete outcomes, complications, and returns to the operating room. Whereas the addition of 3D-RA elucidated residual aneurysm not otherwise visualized on the 2D-IOA, in other cerebrovascular procedures studied, there was no additional value of the 3D-RA over the 2D-IOA.


Assuntos
Angiografia Cerebral/métodos , Transtornos Cerebrovasculares/diagnóstico por imagem , Transtornos Cerebrovasculares/cirurgia , Imageamento Tridimensional/métodos , Monitorização Neurofisiológica Intraoperatória/métodos , Procedimentos Neurocirúrgicos/métodos , Adulto , Idoso , Angiografia Digital/métodos , Feminino , Humanos , Masculino , Microcirurgia/métodos , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos
13.
Clin Neurol Neurosurg ; 194: 105842, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32325400

RESUMO

OBJECTIVE: Digital subtraction angiography is the gold standard for diagnosis of vascular pathology. The value of angiography of non-target vessels following mechanical thrombectomy for the treatment of acute ischemic stroke (AIS) is unknown. PATIENTS AND METHODS: Consecutive patients treated with mechanical thrombectomy for AIS due to large vessel occlusion (LVO) at an academic institution between February 2016 and December 2018 were retrospectively reviewed. Demographic information, clinical data, and procedure details were recorded. Descriptive statistics were used to evaluate the utility of non-target vessel angiography. RESULTS: One hundred and fifty-six patients presenting with AIS due to LVO were treated with 159 mechanical thrombectomy procedures. Median age was 71.5 years. Ninety-one (57.2%) procedures were followed with a diagnostic cerebral angiogram of non-target vessels. Previously unknown findings were identified in 4 (4.4%) procedures. Management change due to the non-target vessel angiogram finding occurred in 3 (3.3%) cases and included one contralateral mechanical thrombectomy. No complications occurred as a result of the non-target vessel angiogram. CONCLUSION: Angiographic imaging of non-target vessels following mechanical thrombectomy identified previously unknown vascular pathology in 4.4% of procedures and resulted in a clinical management change in 3.3% of cases.


Assuntos
Angiografia Cerebral , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/cirurgia , Procedimentos Neurocirúrgicos/métodos , Trombectomia/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Achados Incidentais , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
14.
Interv Neuroradiol ; 26(3): 275-282, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31856647

RESUMO

BACKGROUND: Thromboembolic complications are the primary risks of stent-coiling of cerebral aneurysms. The utility of platelet function testing in stent-assisted aneurysm coiling remains controversial. This study aimed to assess a pharmacy-mediated antiplatelet management protocol for stent-assisted coiling. METHODS: Stent-coiled aneurysms at an academic institution in the United States between 2015 and 2018 were retrospectively reviewed. All patients were managed using a pharmacy-mediated antiplatelet protocol, which required repeated platelet function testing and subsequent dose adjustments. Medication dosage, number of adjustments, aspirin reaction units (ARU) and P2Y12 reaction units (PRU), as well as complication rates, angiographic and functional outcome were analyzed. RESULTS: A total of 56 aneurysms (median size 5 mm, range 2.6-14.0 mm) in 54 patients (median age 58.5 years) were treated with stent-assisted coil embolization. Most aneurysms were located at the basilar tip (28.6%). Median pre-procedure ARU and PRU were 442.5 (range 363-594) and 123.5 (range 1-252), respectively. Approximately two-thirds of all procedures required at least one aspirin dose adjustment and 88.5% of procedures required at least one clopidogrel dose adjustment. There were two (3.6%) thromboembolic complications. One of the thromboembolic complications occurred in a patient where the pharmacy-mediated protocol was violated. There were no hemorrhagic complications. Last imaging follow-up demonstrated complete aneurysm occlusion in 83.9%. CONCLUSION: In patients where the pharmacy-mediated antiplatelet protocol was followed, the thromboembolic complication rate was 1.8%. This complication rate compares favorably to those reported in large contemporary series. Nevertheless, the pharmacy-mediated protocol places a significant burden on both the patient and healthcare system.


Assuntos
Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Inibidores da Agregação Plaquetária/administração & dosagem , Testes de Função Plaquetária , Stents , Angiografia Cerebral , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
J Neurosurg ; 134(1): 115-121, 2019 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-31860816

RESUMO

OBJECTIVE: Mechanical thrombectomy is the established treatment for acute ischemic stroke due to large vessel occlusion (LVO). The authors sought to identify early predictors of a favorable outcome in stroke patients treated with mechanical thrombectomy. METHODS: Consecutive patients with ischemic stroke due to LVO who underwent mechanical thrombectomy at a Comprehensive Stroke Center in the US between 2016 and 2018 were retrospectively reviewed. Demographics, stroke and treatment characteristics, as well as functional outcome at 90 days were collected. Clinical predictors of 90-day functional outcome were assessed and compared to existing indices for prompt neurological improvement. Analyses of area under the receiver operating characteristic curve were performed to estimate the optimal thresholds for absolute 24-hour and delta (change in) National Institutes of Health Stroke Scale (NIHSS) scores for functional outcome prediction. RESULTS: A total of 156 patients (median age 71.5 years) underwent 159 mechanical thrombectomies. The M1 segment of the middle cerebral artery was the most frequent site of occlusion (57.2%). The median NIHSS score before thrombectomy was 18 (IQR 14-24). A postthrombectomy Thrombolysis in Cerebral Infarction score of 2B or 3 was achieved in 147 procedures (92.4%). The median NIHSS score 24 hours after thrombectomy was 14 (IQR 6-22). Good functional outcome at 90 days (modified Rankin Scale score 0-2) was achieved in 37 thrombectomies (23.9%). An absolute 24-hour NIHSS score ≤ 10 (OR 25.929, 95% CI 8.448-79.582, p < 0.001) and a delta NIHSS score ≥ 8 between baseline and 24 hours (OR 4.929, 95% CI 2.245-10.818, p < 0.001) were associated with good functional outcome at 90 days. The 24-hour NIHSS score cutoff of 10 outperformed existing indices for prompt neurological improvement in the ability to predict 90-day functional outcome. CONCLUSIONS: An NIHSS score ≤ 10 at 24 hours after mechanical thrombectomy was independently associated with good functional outcome at 90 days.

18.
Neurosurgery ; 85(suppl_1): S52-S57, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31197334

RESUMO

BACKGROUND: Acute ischemic stroke (AIS) remains a significant source of morbidity and mortality worldwide. Multiple recent randomized clinical trials for AIS patients presenting with large vessel occlusion have demonstrated radical improvement in outcomes with mechanical thrombectomy (MT), which is now recognized as the new standard of care for patients presenting up to 24 hr. OBJECTIVE: To provide a perspective on training and credentialing requirements for practitioners in this field. METHODS: Relevant articles were systematically searched and analyzed. Standards for Reporting Qualitative Research guidelines were utilized. RESULTS: : The Committee for Advanced Subspecialty Training (CAST) brings together the principal specialties of Radiology, Neurology, and Neurosurgery. Their training standards document the most recent consensus on training for neuroendovascular surgery (NES) and include the endovascular treatment of AIS as a part of the field of NES. This unified consensus represents a significant landmark in the evolution of stroke therapy. Presently, training at most centers follows an apprenticeship type model. Simulation methods and objective performance metrics have not been widely incorporated. Maintenance of proficiency has not been conclusively addressed reflecting the overall developing nature of the field. CONCLUSION: The evolution of the standard of care interventional therapy for large vessel AIS utilizing MT raises concerns regarding work force needs, training standards, competency, and credentialing requirements for practitioners. The CAST framework represents the most modern and flexible approach for both individuals and training programs. Methods based on objective performance metrics utilizing simulation as primary vehicle may be the logical next steps in the evolution of NES.


Assuntos
Credenciamento/normas , Neurocirurgia/educação , Neurocirurgia/normas , Procedimentos Neurocirúrgicos/educação , Acidente Vascular Cerebral/cirurgia , Isquemia Encefálica/cirurgia , Procedimentos Endovasculares/educação , Procedimentos Endovasculares/métodos , Humanos , Procedimentos Neurocirúrgicos/métodos
20.
World Neurosurg ; 124: 373-377, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30660878

RESUMO

BACKGROUND: Infectious intracranial aneurysms are rare but encountered when associated with rupture or detected on screening of high-risk patients. The time course of the development of these aneurysms is unknown. Ultimately, the data published on mycotic aneurysms are in the form of case series, retrospective studies, with one recent systematic review, all of which have difficulty defining specifics regarding aneurysmal formation in these patients. We present a case that may help define the time frame of mycotic aneurysm growth. CASE DESCRIPTION: A patient with endocarditis, first identified to have a distal middle cerebral artery aneurysm treated with Onyx embolization, and an otherwise-unremarkable cerebral angiogram experienced significant subarachnoid hemorrhage 5 days later. Within that short time frame on appropriate antibiotic therapy, she developed and ruptured a basilar tip aneurysm, which was subsequently treated with coil embolization. CONCLSUSIONS: The time course of infectious intracranial aneurysm development is not known and difficult to define. This case illustrates an example of the development of a new infectious intracranial aneurysm and subsequent rupture over the course of 5 days, showing that these types of aneurysms and subsequent neurologic sequelae can happen acutely.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA