Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Open Dent J ; 11: 213-220, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28567145

RESUMO

INTRODUCTION: The Moyers' probability tables are used in mixed dentition analysis to estimate the extent of space required for the alignment of canines and premolars, by correlating the mesiodistal size of lower incisors with the size of permanent canines and premolars. OBJECTIVE: This study intended to evaluate the applicability of the Moyer's probability tables for predicting the mesiodistal space needed for the correct location of premolars and permanent canines non-erupted, in adolescents of the city of Cordoba, Argentina, who show different facial biotypes. MATERIALS AND METHODS: Models and tele-radiographies of 478 adolescents of both genders from 10 to 15 years of age were analyzed. The tele-radiographies were measured manually in order to determine the facial biotype. The models were scanned with a gauged scanner (HP 3670) and measured by using Image Pro Plus 4.5 software. RESULTS: According to this study, the comparison between the Moyer´s probability table, and the table created at the National University of Córdoba (UNC) (at 95%, 75%, and 50%) shows that, in both tables, a higher value of mesiodistal width of lower incisors corresponds to a bigger difference in the space needed for permanent canines and premolars; being the need for space for permanents canines and premolars bigger in the UNC´s table. On the other hand, when contrasting the values of mesiodistal space for permanent canines and premolars associated with each facial biotype, the discrepancies between groups were not statistically significant (P >0.05). However, we found differences in the size of the space required according to the mesiodistal width range of the lower incisors for each biotype: a) The comparison of lower-range values, with a mesialdistal width of lower incisors less than 22 mm, the space required for permanent canines and premolars resulted smaller in patients with dolichofacial biotype than in patients with mesofacial and braquifacial biotypes. The latter biotypes have meager differences between them. b) The comparison of mid-range values, with a mesialdistal width of lower incisors from 22 to 25 millimeters, shows that the values of required alignment space are similar in the three facial biotypes. c) Finally, the comparison of upper range values, with a mesialdistal width of lower incisors greater than 25 millimeters, indicates that the space required for dolichofacial biotypes tends to be higher than in mesofacial and brachyfacial biotypes. CONCLUSION: The Moyer´s probability tables should be created to meet the needs of the population under study, with no consideration of patients' facial biotypes.

2.
Claves odontol ; 23(75): 81-84, 2017. ilus
Artigo em Espanhol | LILACS | ID: biblio-972621

RESUMO

La filosofía de la bioadaptación transversal de los maxilares preconiza una nueva forma de generar crecimiento a nivel de los tejidos dento alveolares, a través de una mecánica ortodoncia biológicamente más segura a la hora de realizar expansión transversal. El principio básico de esta filosofía no es soloel uso de brackets autoligantes, ni marcas comerciales específicas, ya que puede utilizarse cualquiera de ellas; se trata de no generar daños colaterales denominados “costos biológicos”, frecuentemente ligados a fuerzas excesivas. Se pretende proporcionar una menor fricción entre bracket y arco, reduciendo así el uso de aparatos auxiliares y el tiempo de tratamiento, aprovechando los beneficios de cada componente. Para generar el crecimiento transversal del maxilar es fundamental el uso de gomas intermaxilares, teniendo como tutores a los segundos molares superiores que son los menos afectados por las disfunciones. Podemos decir que después del correcto estímulo de una fuerza que inicie el proceso de desequilibrio y consecuente respuesta tisular, las fuerzas naturales de la musculatura oral, más las existentes en el sistema de brackets, serán suficientes para definir la necesaria bioadaptación dentoalveolar individual del paciente.


The transverse bioadaptation philosophy of the jaws advocates a new way of generating growth at thelevel of dentoalveolar tissues, through a biologically safer orthodontic mechanics when carrying outtransversal expansion. The basic principle of this philosophy is not only the use of self-ligating bracketsor specific trademarks, since any of them can be used, but also not to generate collateral damagescalled "biological costs" frequently due to excessive forces. Aiming at providing less friction betweenbracket and bow, thus reducing the use of auxiliary appliances and treatment time, taking advantageof the benefits of each component. In order to generate maxilla transversal growth the use ofintermaxillary gums is fundamental, having as tutor the upper second molars that are the least affectedby the dysfunctions. It can be stated that after the correct stimulus of a force that initiates the process of imbalance and consequent tissue response, the natural forces of the oral musculature plus thoseexisting in the bracket system will be sufficient to define the necessary individual dento alveolar bioadaptation of the patient.


Assuntos
Feminino , Humanos , Adulto , Aparelhos de Tração Extrabucal/métodos , Braquetes Ortodônticos , Má Oclusão/classificação , Má Oclusão/terapia , Oclusão Dentária Traumática/terapia , Doenças Periodontais/terapia , Mobilidade Dentária/terapia
3.
Anal Methods ; 8(23): 4617-4631, 2016 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-38396386

RESUMO

In the present report, a chemometrics-assisted second-order kinetic-spectrophotometric method has been developed for determining reducing sugars, glucose, fructose and lactose, in food samples, based on the reaction with hexacyanoferrate, HCF, at 70 °C in alkaline medium. A suitable experimental design helped us to establish the conditions (pH, temperature, and HCF concentration) for optimal sensitivity and selectivity among analytes. Second order data were recorded by measuring the absorbance of unreacted HCF in the spectral range of 370 to 470 nm for five minutes using a diode array. A calibration set of samples was prepared according to a central composite design containing the three sugars for training the algorithms. Validation samples containing only the analytes were prepared for checking the reliability of the algorithms. In this particular system, identical profiles for sample components are obtained in the spèctral dimension corresponding to unreacted HCF. Moreover, two kinds of interferents may be present: sample components active in the spectral region at which HCF absorbs as well as potential reducing interferents, causing linear dependence, since they provide identical profiles in spectral dimension to those of the analytes of interest. In the present work, MCR-ALS in the spectral augmentation mode was the only algorithm that could successfully resolve linear dependence. Satisfactory results were obtained by applying MCR-ALS in the spectral augmentation mode in order to achieve a second order advantage for the determination of fructose and glucose in validation samples, in test samples containing the two kinds of interferents and in real food samples, providing LODs of 4.0 and 5.0 mg L-1, respectively. However, bad results were obtained for lactose which may be due to its low sensitivity in the augmented dimension. Good results were also obtained by applying U-PLS/RBL and N-PLS/RBL for determining simultaneously the three sugars in validation samples and in test samples containing only active spectral interferents. Finally, lactose and also, glucose and fructose, were successfully quantified in real milk samples, with LODmin = 1.0 mg L-1, 1.0 mg L-1 and 0.1 mg L-1 and LODmax = 3.5, 3.8 and 4.4 mg L-1, respectively, using UPLS/RBL, and LODmin of 1.3, 1.1 and 0.1 mg L-1 and LODmax of 4.0, 4.3 and 4.9 mg L-1 for lactose, glucose and fructose, respectively, for NPLS/RBL. Results for real samples in all cases were statistically comparable to those obtained by applying a reference method based on HPLC (High Performance Liquid Chromatography).

4.
J AOAC Int ; 97(1): 39-49, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24672858

RESUMO

This report reviews recent literature on the application of multivariate calibration techniques to both first- and second-order data, aimed at the analytical determination of analytes of interest or sample properties in a variety of industrial, pharmaceutical, food, and environmental samples, including examples of process control. The most used data processing tools are briefly described, with emphasis on the advantages that can be obtained by applying specific combinations of multivariate data and algorithms. The main focus is on works devoted to first-order data (i.e., spectra, chromatograms, etc.) combined with partial least-squares regression, which has become the standard for this type of analytical research. A brief discussion on recent work on second-order data and algorithms is also included, as this field is rapidly growing, although at present it does not show, the general applicability of the first-order counterparts.


Assuntos
Técnicas de Química Analítica/métodos , Algoritmos , Análise de Alimentos/métodos , Análise Multivariada
5.
Artigo em Inglês | MEDLINE | ID: mdl-22365532

RESUMO

Quantitative analytical works developed by processing second- and third-order chromatographic data are reviewed. The various modes in which data of complex structure can be measured are discussed, with chromatographic separation providing either one or two of the data dimensions. This produces second-order data (matrices from uni-dimensional chromatography with multivariate detection or from two-dimensional chromatography) or third-order data (three-dimensional data arrays from two-dimensional chromatography with multivariate detection). The available algorithms for processing these data are classified and discussed, regarding their ability to cope with the ubiquitous phenomenon of retention time shifts from run to run. A summary of relevant works applying this combination of techniques is presented, with focus on quantitative analytical results. Special attention is paid to works achieving the full potentiality of the multidimensional data, i.e., the second-order advantage.


Assuntos
Cromatografia/normas , Mineração de Dados/métodos , Algoritmos , Calibragem , Cromatografia/métodos , Análise Multivariada
6.
Talanta ; 85(3): 1526-34, 2011 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-21807218

RESUMO

A second-order multivariate calibration method based on a combination of unfolded partial least-squares (U-PLS) with residual bilinearization (RBL) has been applied to second-order data obtained from excitation-emission fluorescence matrices for determining atenolol in human urine, even in the presence of background interactions and fluorescence inner filter effects, which are both sample dependent. Atenolol is a cardioselective beta-blocker, which is considered a doping agent in shoot practice, so that its determination in urine can be required for monitoring the drug. Loss of trilinearity due to analyte-background interactions which may vary between samples, as well as inner filter effects, precludes the use of methods like parallel factor analysis (PARAFAC) that cannot handle trilinearity deviations, and justifies the employment of U-PLS. Successful analysis required to include the background in the calibration set. Unexpected components appear in new urine samples, different from those used in calibration set, requiring the second-order advantage which is obtained from a separate procedure known as residual bilinearization (RBL). Satisfactory results were obtained for artificially spiked urines, and also for real urine samples. They were statistically compared with those obtained applying a reference method based on high-performance liquid chromatography (HPLC).


Assuntos
Atenolol/urina , Cromatografia Líquida de Alta Pressão/métodos , Análise dos Mínimos Quadrados , Espectrometria de Fluorescência/métodos , Algoritmos , Atenolol/química , Calibragem , Monitoramento de Medicamentos/métodos , Fluorescência , Humanos , Reprodutibilidade dos Testes
7.
Talanta ; 83(4): 1173-80, 2011 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-21215852

RESUMO

Liquid chromatographic-diode array detection data recorded for aqueous mixtures of 11 pesticides show the combined presence of strongly coeluting peaks, distortions in the time dimension between experimental runs, and the presence of potential interferents not modeled by the calibration phase in certain test samples. Due to the complexity of these phenomena, data were processed by a second-order multivariate algorithm based on multivariate curve resolution and alternating least-squares, which allows one to successfully model both the spectral and retention time behavior for all sample constituents. This led to the accurate quantitation of all analytes in a set of validation samples: aldicarb sulfoxide, oxamyl, aldicarb sulfone, methomyl, 3-hydroxy-carbofuran, aldicarb, propoxur, carbofuran, carbaryl, 1-naphthol and methiocarb. Limits of detection in the range 0.1-2 µg mL(-1) were obtained. Additionally, the second-order advantage for several analytes was achieved in samples containing several uncalibrated interferences. The limits of detection for all analytes were decreased by solid phase pre-concentration to values compatible to those officially recommended, i.e., in the order of 5 ng mL(-1).


Assuntos
Cromatografia Líquida/métodos , Resíduos de Praguicidas/análise , Água/química , Calibragem , Cromatografia Líquida/instrumentação , Cromatografia Líquida/normas , Eletrodos , Análise Multivariada , Resíduos de Praguicidas/isolamento & purificação , Reprodutibilidade dos Testes , Extração em Fase Sólida , Fatores de Tempo
8.
Anal Chim Acta ; 677(2): 97-107, 2010 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-20837177

RESUMO

Four-way data were obtained by recording the kinetic evolution of excitation-emission fluorescence matrices for samples containing the analytes carbaryl and 1-naphthol, two widely employed pesticides, in the concentration ranges 0-363 µg L(-1) and 0-512 µg L(-1), respectively. The reaction followed was the alkaline hydrolysis of carbaryl to produce 1-naphthol, a fact which introduced strong linear dependencies and multi-linearity losses in the analyzed system. Data processing was performed with unfolded partial least-squares combined with residual trilinearization (U-PLS/RTL) and also with a suitably initialized and restricted parallel factor model (PARAFAC), combined with calibration based on multi-linear regression. U-PLS/RTL is shown to be significantly simpler in its implementation and to provide similar figures of merit. The applied chemometric strategy is able to successfully determine the analytes in water samples containing uncalibrated interferences, such as other commonly employed agrochemicals and also a naturally occurring background signal.


Assuntos
Algoritmos , Carbaril/análise , Naftóis/análise , Praguicidas/análise , Espectrometria de Fluorescência , Água/química , Agroquímicos/análise , Agroquímicos/química , Calibragem , Carbaril/química , Hidrólise , Cinética , Análise dos Mínimos Quadrados , Modelos Lineares , Naftóis/química , Praguicidas/química
9.
Claves odontol ; 16(63): 9-12, mayo 2009. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-532919

RESUMO

Este trabajo de investigación se realizó con el fin de evaluar el grado de movilidad lingual en pacientes con maloclusión y anquiloglosia, para lo cual previamente y mediante una prueba piloto, se obtuvo el promedio de apertura bucal máxima (ABM) en individuos de las tres denticiones. Se trabajó con una población de 369 pacientes con maloclusión entre 5 a 45 años de edad, de ambos sexos, en denticiones primaria, mixta y permanente, que concurrieron espontáneamente durante el período de un año (noviembre 2003-2004), a la Cátedra de Integral Niños área Ortodoncia A, a la Clínica Odontológica y a la Escuela de Graduados de la Facultad de Odontología de la UNC, República Argentina. La medición se realizó con un calibre de Boley sobre la línea media, valorando la distancia en mm que separa los bordes incisales de los incisivos centrales superiores e inferiores, estando el paciente en apertura bucal máxima (ABM), sin esfuerzo. Los resultados obtenidos fueron: de los 369 pacientes con maloclusión, la ABM en pacientes con dentición primaria (n=105) fue de 42,2 mm, en aquello individuos con dentición mixta (n=152) fue de 46,36mm y en los pacientes con dentición permanente (n=112) fue de 47,38mm.


Assuntos
Humanos , Masculino , Adolescente , Adulto , Pré-Escolar , Criança , Feminino , Dentição Mista , Dentição Permanente , Doenças da Língua/diagnóstico , Má Oclusão/diagnóstico , Má Oclusão/epidemiologia , Dente Decíduo , Argentina/epidemiologia , Faculdades de Odontologia , Freio Lingual , Músculos da Mastigação/fisiopatologia , Interpretação Estatística de Dados
10.
Talanta ; 78(1): 57-65, 2009 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-19174203

RESUMO

In the present work a chemometric-assisted molecularly imprinted polymer (MIP)-fluorescence optosensing system has been developed for determining monoamines naphthalene compounds in drinking waters. The use of chemometrics for processing flow injection analysis with MIP fluorescence optosensor data allowed the simultaneous determination of the principal monoamine naphthalene compounds 1-naphthylamine (1-NA) and 2-naphthylamine (2-NA) even in presence of potential interferent 1-naphthalenemethylamine (1-NMA). Classical chemometrics tools such as partial least-squares (PLS-1), as well as second-order algorithms like multiway PLS (N-PLS) and unfolded PLS (U-PLS), were successfully applied, assisting fluorescence emission spectra at a fixed excitation wavelength or excitation-emission fluorescence matrices (EEM), respectively, when interferents are considered in the calibration set. The combinations of both N-PLS and U-PLS with residual bilinearization (RBL), achieving the second-order advantage, were satisfactory applied for the simultaneous determination of the main monoamine naphthalene compounds in drinking water, in the presence of a potential interferent without sample pretreatment, even when the later is not modeled in calibration set. Predictive ability, accuracy, figures of merit, as well as advantages and disadvantages of the different strategies were discussed.


Assuntos
Naftalenos/análise , Espectrometria de Fluorescência/métodos , Abastecimento de Água/análise , Aminas/análise , Calibragem , Impressão Molecular
11.
Analyst ; 134(8): 1682-91, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20448938

RESUMO

Synchronous fluorescence spectra measured in a flow-injection system with double pH gradient modulation constitute a new second-order signal which is herein studied for the quantitative determination of three fluoroquinolone antibiotics in spiked human urine samples. Because calibration is done using aqueous solutions of each of the three analytes ciprofloxacin, norfloxacin and ofloxacin, the fluorescent urine background makes it necessary to achieve the second-order advantage. Several second-order multivariate calibration algorithms were evaluated for this purpose: parallel factor analysis, unfolded and multiway partial least-squares with residual bilinearization, and multivariate curve resolution-alternating least-squares. The best analytical figures of merit, a root mean square error of 4-6 mg L(-1) (corresponding to a relative error of 4-6% for a calibration range from 0 to 200 mg L(-1) for each analyte), and a limit of detection of 4 mg L(-1) were obtained using partial least-squares (in the specific unfolded version) combined with residual bilinearization. Reasons for the improved success of this latter technique are provided on the basis of the analysis of simulated second-order data.


Assuntos
Análise Fatorial , Análise de Injeção de Fluxo/métodos , Fluorescência , Fluoroquinolonas/química , Desnaturação de Ácido Nucleico/efeitos dos fármacos , Espectrometria de Fluorescência/métodos , Algoritmos , Antibacterianos/química , Antibacterianos/urina , Ciprofloxacina/química , Ciprofloxacina/urina , Técnicas de Laboratório Clínico , Fluoroquinolonas/urina , Humanos , Concentração de Íons de Hidrogênio , Análise dos Mínimos Quadrados , Norfloxacino/química
12.
Anal Chem ; 80(19): 7248-56, 2008 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-18752340

RESUMO

Four-way data were obtained by recording the kinetic evolution of excitation-emission fluorescence matrices for the product of the Hantzsch reaction between the analyte malonaldehyde and methylamine. The reaction product, 1,4-disubstituted-1,4-dihydropyridine-3,5-dicarbaldehyde, is a highly fluorescent compound. The nonlinear nature of the kinetic fluorescence data has been demonstrated, and therefore the four-way data were processed with parallel factor analysis combined with a nonlinear pseudounivariate regression, based on a quadratic polynomial fit, and also with a recently introduced neural network methodology, based on the combination of unfolded principal component analysis, residual trilinearization, and radial basis functions. The applied chemometric strategies are not only able to adequately model the nonlinear data but also to successfully determine malonaldehyde in olive oil samples. This is possible since the experimentally recorded four-way data, modeled with the above-mentioned advanced chemometric approaches, permit the achievement of the second-order advantage. This allows us to predict the analyte concentration in a complex background, in spite of the nonlinear behavior and in the presence of uncalibrated interferences. The present work is a new example of the use of higher-order data for the resolution of a complex nonlinear system, successfully employed in the context of food chemical analysis.


Assuntos
Malondialdeído/análise , Redes Neurais de Computação , Óleos de Plantas/análise , Espectrometria de Fluorescência/métodos , Algoritmos , Interpretação Estatística de Dados , Análise de Alimentos/métodos , Cinética , Malondialdeído/química , Metilaminas/análise , Metilaminas/química , Dinâmica não Linear , Azeite de Oliva , Óleos de Plantas/química
13.
Anal Chem ; 79(18): 6949-58, 2007 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-17688323

RESUMO

A new third-order multivariate calibration approach, based on the combination of multiway-partial least-squares with a separate procedure called residual trilinearization (N-PLS/RTL), is presented and applied to multicomponent analysis using third-order data. The proposed chemometric algorithm is able to predict analyte concentrations in the presence of unexpected sample components, which require strict adherence to the second-order advantage. Results for the determination of procaine and its metabolite p-aminobenzoic acid in equine serum are discussed, based on kinetic fluorescence excitation-emission four-way measurements and application of the newly developed multiway methodology. Since the analytes are also the reagent and product of the hydrolysis reaction followed by fast-scanning fluorescence spectroscopy, the classical approach based on parallel factor analysis is challenged by strong linear dependencies and multilinearity losses. In comparison, N-PLS/RTL appears an appealing genuine multiway alternative that avoids the latter complications, yielding analytical results that are statistically comparable to those rendered by related unfolded algorithms, which are also able to process four-way data. Prediction was made on validation samples with a qualitative composition similar to the calibration set and also on test samples containing unexpected equine serum components.


Assuntos
Ácido 4-Aminobenzoico/análise , Anestésicos Locais/análise , Modelos Químicos , Procaína/análise , Soro/química , Ácido 4-Aminobenzoico/química , Anestésicos Locais/metabolismo , Animais , Cavalos , Cinética , Análise dos Mínimos Quadrados , Procaína/metabolismo , Espectrometria de Fluorescência
14.
Analyst ; 132(7): 654-63, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17592584

RESUMO

Three different experimental systems have been studied regarding the determination of analytes in complex samples, using non-linear second-order instrumental data, which are intrinsically able to provide the second-order advantage. This permits the quantitation of calibrated analytes in the presence of unexpected sample components, although a suitable algorithm is required. The recently described combination of artificial neural networks with post-training residual bilinearization has been applied to the three data sets, with successful results concerning prediction accuracy and precision, as well as profile recovery for the potential interferents in test samples. The studies involve: (1) the determination of two pharmaceuticals in the presence of an unexpected excipient by absorbance-pH matrix measurements, (2) the quantitation of iron(II) by its catalytic effect on the kinetics of the bromate oxidation of a colorant in the presence of a second interfering organic dye, and (3) the analysis of the antibiotic amoxicillin by fluorescence excitation-emission matrices in the presence of a fluorescent anti-inflammatory. The prediction results were compared and shown to be significantly better than those yielded by the unfolded partial least-squares/residual bilinearization model, due to the non-linear nature of the studied data.


Assuntos
Interpretação Estatística de Dados , Redes Neurais de Computação , Análise Espectral , Amoxicilina/análise , Animais , Calibragem , Humanos , Ferro/análise
15.
Anal Chim Acta ; 588(2): 192-9, 2007 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-17386810

RESUMO

Fluorescence excitation-emission data recorded for amoxicillin after photo-activated reaction with periodate have been processed by a novel second-order multivariate method based on the combination of artificial neural networks and residual bilinearization (ANN/RBL), since the signals bear a strong non-linear relation with the analyte concentration. The selected chemometric methodology is employed for the first time to evaluate experimental non-linear second-order spectral information. Due to severe overlapping between the emission profiles for the analyte reaction product and for the urine background, calibration was done using different spiked urine samples. This allowed for the determination of amoxicillin in test spiked urines, other than those employed for calibration. When new urine samples containing a fluorescent anti-inflammatory were analyzed, accurate prediction in the presence of unexpected components required the achievement of the second-order advantage, which is provided by the post-training RBL procedure. Amoxicillin was also determined by ANN/RBL in a series of real urine samples, which allowed one to perform a comparison study with the reference high-performance liquid chromatographic technique.


Assuntos
Amoxicilina/urina , Antibacterianos/urina , Redes Neurais de Computação , Espectrometria de Fluorescência/métodos , Calibragem , Cromatografia Líquida de Alta Pressão , Humanos
16.
Claves odontol ; 14(59): 20-24, mar. 2007. ilus, graf
Artigo em Espanhol | LILACS | ID: lil-498236

RESUMO

El propósito de esta investigación surge a partir de la observación, cada vez más frecuente, de pacientes con maloclusiones, cuya causa principal es la anquiloglosia parcial o total. El objetivo fue determinar la cantidad de pacientes con maloclusión que presentaban anquiloglosia sobre una muestra de 282 pacientes de ambos sexos, correspondientes a las tres denticiones, quienes durante el período de un año (noviembre 2003-2004) concurrieron espontáneamente a la Facultad de Odontología de la UNC. En primer término, se evaluó la presencia de anquiloglosia, su frecuencia, y la maloclusión más frecuente en los pacientes con y sin anquiloglosia. Para categorizar los distintos tipos y grados de anquiloglosia, se aplicaron dos métodos de evaluación, considerándose 0 la norma en ambos grupos: (1) grado de movilidad lingual grados 0, 1, 2, 3, 4 (G), referido a la ubicación de la punta de la lengua y su relación con el paladar duro, por detrás de los incisivos superiores, estando el paciente en apertura bucal máxima (ABM); (2) longitud del frenillo lingual tipo 0, I, II, III, IV, medido con calibre de Boley, desde la inserción del frenillo hasta la punta de la lengua, considerándose clínicamente aceptable la lengua libre mayor de 16 mm. Los resultados obtenidos fueron: sobre 282 pacientes con maloclusión, 153 presentaron anquiloglosia, en los cuales la maloclusión más frecuente fue la Clase II, con 43,14 por ciento (n=66), siendo el grado de movilidad lingual G2 (n=92) con 60.13 por ciento y la longitud del frenillo lingual, Tipo II (n=65) con 42,50 por ciento, las más frecuentes.


Assuntos
Humanos , Masculino , Feminino , Doenças da Língua/classificação , Doenças da Língua/complicações , Doenças da Língua/diagnóstico , Freio Lingual/anormalidades , Má Oclusão Classe II de Angle/epidemiologia , Má Oclusão Classe II de Angle/etiologia , Argentina/epidemiologia , Doenças da Língua/epidemiologia , Língua/patologia , Interpretação Estatística de Dados
17.
Talanta ; 71(2): 806-15, 2007 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-19071378

RESUMO

The kinetic evolution of UV-visible absorption spectra of amoxicillin in the presence of copper(II) ions has been processed by the second-order multivariate methods parallel factor analysis (PARAFAC) and also by a novel approach based on partial least-squares with residual bilinearization (PLS/RBL). The latter one is employed for the first time to evaluate kinetic-spectral information. The mechanism of the analyte metal-catalyzed hydrolysis involves a reaction intermediate and a final reaction product, both with spectra which may allow for the determination of amoxicillin in human urine, even in the presence of unsuspected sample components. This is possible thanks to the second-order advantage exploited by the employed chemometric algorithms, among which PARAFAC and PLS/RBL gave the best results. Amoxicillin was determined in a series of spiked and real urine samples, which allowed to perform, respectively, a recovery study and a comparison with the reference high-performance liquid chromatographic technique. The best figures of merit were obtained with PLS/RBL, namely sensitivity, 0.5AUL mg(-1) (AU=absorbance units), analytical sensitivity, 500L mg(-1) and limit of detection, 6mg L(-1). Relative advantages and disadvantages of the employed algorithms are discussed.

18.
J Pharm Biomed Anal ; 36(3): 541-7, 2004 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-15522528

RESUMO

The simultaneous determination of levodopa and benserazide in pharmaceutical formulations is described, based on the application of multidimensional partial least-squares regression to the kinetic-spectrophotometric data provided by diode-array detection within a stopped-flow injection method where analytes react with periodate. Flow injection parameters were adequately optimized. Accurate analysis is performed with no sample pre-treatment steps, and with minimum experimental effort. Satisfactory recovery results were obtained on a number of synthetic and commercial samples, in the latter case including the comparison with liquid chromatography measurements.


Assuntos
Benserazida/análise , Levodopa/análise , Cromatografia Líquida de Alta Pressão/métodos , Análise de Injeção de Fluxo/métodos , Análise Multivariada , Espectrofotometria Ultravioleta/métodos
19.
Anal Chem ; 76(10): 2798-806, 2004 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-15144190

RESUMO

The analytical performances of two algorithms, the recently introduced bilinear least-squares (BLLS) and the popular parallel factor analysis (PARAFAC), are compared as regards second-order fluorescence data recorded for the determination of the fluoroquinolone antibiotic ciprofloxacin in human urine samples. The applied chemometric methodologies employ different strategies for exploiting the so-called second-order advantage, which allows one to obtain individual concentrations of calibrated analytes in the presence of any number of uncalibrated (urine) components. Analysis of a spiked urine test set (in the analyte concentration range 0-200 mg L(-1)) showed that BLLS provides results of slightly better quality than PARAFAC. Satisfactory results have been obtained on comparing the concentrations predicted for a series of real urine samples with those furnished by liquid chromatography. The limit of detection of the fluorescence-based methods is approximately 5 mg L(-1).


Assuntos
Antibacterianos/urina , Ciprofloxacina/urina , Espectrometria de Fluorescência/métodos , Calibragem , Ciprofloxacina/química , Análise Fatorial , Fluoroquinolonas/química , Humanos , Análise dos Mínimos Quadrados , Análise Multivariada
20.
Anal Bioanal Chem ; 376(7): 1141-6, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12838381

RESUMO

A rapid, selective, sensitive and simple fluorescence method was developed for the direct determination of celecoxib in capsules. The capsules were emptied, pulverized and dissolved in either ethanol or acetonitrile, sonicated and filtered. Direct fluorescence emission was measured at 355+/-5 nm (exciting at 272 nm). The method was fully validated and the recoveries were excellent, even in presence of excipients.


Assuntos
Anti-Inflamatórios não Esteroides/análise , Sulfonamidas/análise , Calibragem , Cápsulas , Celecoxib , Indicadores e Reagentes , Estrutura Molecular , Pirazóis , Reprodutibilidade dos Testes , Espectrometria de Fluorescência/métodos , Sulfonamidas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA