Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Rapid Commun Mass Spectrom ; 29(21): 1938-46, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26443391

RESUMO

RATIONALE: Brazil is the largest producer of sugar cane bioethanol in the world. Isotope ratio mass spectrometry (IRMS) is the technique of choice to certify the origin/raw materials for ethanol production, but the lack of certified reference materials (CRMs) for accurate measurements of δ(13) C values traceable to Vienna Pee Dee Belemnite (VPDB), the international zero point for (13) C/(12) C measurements, certified and compatible with gas chromatography (GC)/IRMS instruments may compromise the accuracy of δ(13) C determinations. METHODS: We evaluated the influence of methods for the calibration and normalization of raw δ(13) C values of ethanol samples. Samples were analyzed by GC/C/IRMS using two different GC columns. Different substances were used as isotopic standards for the working gas calibration. The δ(13) C values obtained with the three methods of normalization were statistically compared with those obtained with elemental analyzer (EA)/IRMS, since the δ(13) C results obtained using EA are traceable to VPDB via the NBS 22 reference material. RESULTS: It was observed that both the isotopic reference material for CO2 calibration and the GC column have a major effect on the δ(13) C measurements, leading to a bias of almost 2-3 ‰ in the δ(13) C values. All three methods of normalization were equivalent in performance, enabling an improvement in the GC/C/IRMS accuracy, compared with the EA/IRMS reference values for the samples. CONCLUSIONS: All the methods of CO2 calibration, chromatography and normalization presented in this work demonstrated several sources of traceability and accuracy loss for the determination of δ(13) C values in ethanol fuel samples by GC/C/IRMS. This work has also shown the importance of using proper CRMs traceable to VPBD that should be compatible and certified using GC/C/IRMS, ideally in a wide range of δ(13) C values. This is important not only for bioethanol fuel samples, but also for many analytes commonly analyzed by IRMS.

2.
Anal Bioanal Chem ; 407(13): 3799-816, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25801382

RESUMO

Direct methods based on (1)H NMR spectroscopic techniques have been developed for the determination of neutral lipids (triglycerides and free fatty acids) and polar lipids (glyceroglycolipids/phospholipids) in the solvent extracts of oleaginous microalgal biomasses cultivated on a laboratory scale with two species in different media. The chemical shift assignments observed in the (1)H and (13)C NMR spectra corresponding to unsaturated (C18:N, N = 1-3, C20:3, C20:5, C22:6, epoxy) and saturated (C14-C18) fatty acid ester components in a complex matrix involving overlapped resonances have been unambiguously confirmed by the application of 2D NMR spectroscopy (total correlation spectroscopy and heteronuclear single quantum coherence-total correlation spectroscopy). The study of the effect of a polar lipid matrix on the determination of neutral lipids by an internal reference blending process by a systematic designed experimental protocol has provided absolute quantification. The fatty acid composition of algal extracts was found to be similar to that of vegetable oils containing saturated (C16-C18:0) and unsaturated (C18:N, N = 1-3, C20:N, N = 3-4, C22:6) fatty acids as confirmed by NMR spectroscopy and gas chromatography-mass spectrometry analyses. The NMR methods developed offer great potential for rapid screening of algal strains for generation of algal biomass with the desired lipid content, quality, and potential for biodiesel and value-added polyunsaturated fatty acids in view of the cost economics of the overall cost of generation of the biomass.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Lipídeos/análise , Microalgas/química , Espectroscopia de Prótons por Ressonância Magnética/métodos , Biomassa
3.
J Mass Spectrom ; 48(9): 989-97, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24078238

RESUMO

We have studied the behavior of isomers and analogues by traveling wave ion mobility mass spectrometry (TWIM-MS) using drift-gases with varying masses and polarizabilities. Despite the reduced length of the cell (18 cm), a pair of constitutional isomers, N-butylaniline and para-butylaniline, with theoretical collision cross-section values in helium (ΩHe ) differing by as little as 1.2 Å(2) (1.5%) but possessing contrasting charge distribution, showed baseline peak-to-peak resolution (Rp-p ) for their protonated molecules, using carbon dioxide (CO2), nitrous oxide (N2O) and ethene (C2H4 ) as the TWIM drift-gas. Near baseline Rp-p was also obtained in CO2 for a group of protonated haloanilines (para-chloroaniline, para-bromoaniline and para-iodoaniline) which display contrasting masses and theoretical ΩHe , which differ by as much as 15.7 Å(2) (19.5%) but similar charge distributions. The deprotonated isomeric pair of trans-oleic acid and cis-oleic acid possessing nearly identical theoretical ΩHe and ΩN2 as well as similar charge distributions, remained unresolved. Interestingly, an inversion of drift-times were observed for the 1,3-dialkylimidazolium ions when comparing He, N2 and N2O. Using density functional theory as a means of examining the ions electronic structure, and He and N2-based trajectory method algorithm, we discuss the effect of the long-range charge induced dipole attractive and short-range Van der Waals forces involved in the TWIM separation in drift-gases of differing polarizabilities. We therefore propose that examining the electronic structure of the ions under investigation may potentially indicate whether the use of more polarizable drift-gases could improve separation and the overall success of TWIM-MS analysis.

4.
J Chromatogr A ; 1310: 133-7, 2013 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-23992881

RESUMO

Ion mobility mass spectrometry performed in a compact traveling wave cell (TWIM-MS) is shown to provide a reliable, fast and repeatable method to separate derivatized steroid isomers. Three steroid isomer pairs were analyzed in their native form and as their p-toluenesulfonyl isocyanate derivatives. The native steroids were separated from each other, but no separation could be attained for the isomers. The derivatized steroid isomers were, however, properly separated by TWIM-MS with peak-to-peak resolutions close to or as high as baseline resolution (Rp-p=0.77-1.08).


Assuntos
Espectrometria de Massas/métodos , Esteroides/isolamento & purificação , Isomerismo , Limite de Detecção , Reprodutibilidade dos Testes , Esteroides/análise , Esteroides/química
5.
Org Biomol Chem ; 10(42): 8396-402, 2012 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-22971962

RESUMO

Corrole and four of its isomers with subtle structural changes promoted by exchange of nitrogen and carbon atoms in the corrole ring have been studied by traveling wave ion mobility mass spectrometry and collision induced dissociation experiments. Significant differences in shapes and charge distributions for their protonated molecules were found to lead to contrasting gas phase mobilities, most particularly for corrorin, the most "confused" isomer. Accordingly, corrorin was predicted by B3LYP/6-31g(d,p) and collisional cross section calculations to display the most compact tri-dimensional structure, whereas NCC4 and corrole were found to be the most planar isomers. Better resolution between the corrole isomers was achieved using the more polarizable and massive CO(2) as the drift gas. Sequential losses of HF molecules were found to dominate the dissociation chemistry of the protonated molecules of these corrole isomers, but their unique structures caused contrasting labilities towards CID, whereas NCC4 showed a peculiar and structurally diagnostic loss of NH(3), allowing its prompt differentiation from the other isomers.

6.
J Mass Spectrom ; 47(6): 712-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22707163

RESUMO

Travelling wave ion mobility mass spectrometry (TWIM-MS) with post-TWIM and pre-TWIM collision-induced dissociation (CID) experiments were used to form, separate and characterize protomers sampled directly from solutions or generated in the gas phase via CID. When in solution equilibria, these species were transferred to the gas phase via electrospray ionization, and then separated by TWIM-MS. CID performed after TWIM separation (post-TWIM) allowed the characterization of both protomers via structurally diagnostic fragments. Protonated aniline (1) sampled from solution was found to be constituted of a ca. 5:1 mixture of two gaseous protomers, that is, the N-protonated (1a) and ring protonated (1b) molecules, respectively. When dissociated, 1a nearly exclusively loses NH(3) , whereas 1b displays a much diverse set of fragments. When formed via CID, varying populations of 1a and 1b were detected. Two co-existing protomers of two isomeric porphyrins were also separated and characterized via post-TWIM CID. A deprotonated porphyrin sampled from a basic methanolic solution was found to be constituted predominantly of the protomer arising from deprotonation at the carboxyl group, which dissociates promptly by CO(2) loss, but a CID-resistant protomer arising from deprotonation at a porphyrinic ring NH was also detected and characterized. The doubly deprotonated porphyrin was found to be constituted predominantly of a single protomer arising from deprotonation of two carboxyl groups.

7.
J Mass Spectrom ; 47(1): 1-6, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22282083

RESUMO

Venturi easy ambient sonic spray ionization mass spectrometry in both its liquid (V(L) -EASI-MS) and solid sample modes (V(S) -EASI-MS) is shown to provide nearly immediate and secure typification of woods, as demonstrated for Mahogany, an endangered and most valuable type of tropical wood. This reddish wood displays unique phytochemical markers (phragmalin-type limonoids) which are rapidly detected from the wood surface by V(S) -EASI-MS or from a simple methanol extract of a tiny wood chip by V(L) -EASI-MS. Unique profiles were obtained for Mahogany (Swietenia macrophylla) whereas genuine samples of six other similar types of woods, which are commonly falsified by artificial coloring and commercialized as Mahogany, display also typical but dissimilar pythochemical profiles as compared to that of the authentic wood. Variable and atypical chemical profiles were observed for artificially colored woods. Secure chemical characterization via V(S) -EASI-MS or V(s) -EASI-MS fingerprints of Mahogany and other types of woods with similar appearance should help to control the illegal logging and trade of this and other endangered woods and their falsification, and to create certified standards.


Assuntos
Meliaceae/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Madeira/classificação , Fracionamento Químico , Espécies em Perigo de Extinção , Limoninas/análise , Metanol , Árvores , Madeira/análise , Madeira/química
8.
Rapid Commun Mass Spectrom ; 26(3): 263-8, 2012 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-22223311

RESUMO

The ability of travelling wave ion mobility mass spectrometry (TWIM-MS) to resolve cationic meta/para and cis/trans isomers of mono-, di-, tri- and tetra-ruthenated supramolecular porphyrins was investigated. All meta isomers were found to be more compact than the para isomers and therefore mixtures of all isomeric pairs could be properly resolved with baseline or close to baseline peak-to-peak resolution (R(p-p)). Di-substituted cis/trans isomers were found, however, to present very similar drift times and could not be resolved. N(2) and CO(2) were tested as the drift gas, and similar α but considerably better values of R(p) and R(p-p) were always observed for CO(2).


Assuntos
Espectrometria de Massas/métodos , Porfirinas/química , Rutênio/química , Dióxido de Carbono , Isomerismo , Modelos Moleculares , Nitrogênio
9.
J Mass Spectrom ; 47(12): 1643-7, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23280753

RESUMO

The use of CO(2) as a massive and polarizable drift gas is shown to greatly improve peak-to-peak resolution (R(p-p) ), as compared with N(2) , for the separation of disaccharides in a Synapt G2 traveling wave ion mobility cell. Near or baseline R(p-p) was achieved for three pairs of sodiated molecules of disaccharide isomers, that is, cellobiose and sucrose (R(p-p) = 0.76), maltose and sucrose (R(p-p) = 1.04), and maltose and lactose (R(p-p) = 0.74). Ion mobility mass spectrometry using CO(2) as the drift gas offers therefore an attractive alternative for fast and efficient separation of isomeric disaccharides.


Assuntos
Dióxido de Carbono/química , Dissacarídeos/isolamento & purificação , Espectrometria de Massas/métodos , Dissacarídeos/análise , Dissacarídeos/química
10.
Anal Bioanal Chem ; 400(9): 3053-64, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21475947

RESUMO

Meta-chlorophenylpiperazine (m-CPP) is a new illicit drug that has been sold as ecstasy tablets. Easy ambient sonic-spray ionization mass spectrometry (EASI-MS) and X-ray fluorescence spectrometry (XRF) are shown to provide relatively simple and selective screening tools to distinguish m-CPP tablets from tablets containing amphetamines (mainly 3,4-methylenedioxymethamphetamine (MDMA)). EASI-MS detects the active ingredients in their protonated forms: [m-CPP + H](+) of m/z 197, [MDMA + H](+) of m/z 194, and [2MDMA + HCl + H](+) of m/z 423 and other ions from excipients directly on the tablet surface, providing distinct chemical fingerprints. XRF identifies Cl, K, Ca, Fe, and Cu as inorganic ingredients present in the m-CPP tablets. In contrast, higher Cl concentrations and a more diverse set of elements (P, Cl, Ca, Fe, Cu, Zn, Pt, V, Hf, Ti, Pt, and Zr) were found in MDMA tablets. Principal component analysis applied to XRF data arranged samples in three groups: m-CPP tablets (four samples), MDMA tablets (twenty three samples), and tablets with no active ingredients (three samples). The EASI-MS and XRF techniques were also evaluated to quantify m-CPP in ecstasy tablets, with concentrations ranging from 4 to 40 mg of m-CPP per tablets. The m-CPP could only be differentiated from its isomers (o-CPP and for the three isomers p-CPP) by traveling wave ion mobility mass spectrometry and NMR measurements.

11.
Chemphyschem ; 12(8): 1444-7, 2011 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-21370379

RESUMO

Travelling-wave ion mobility mass spectrometry was used to measure the intrinsic mobility of a series of gaseous supra-cation and supra-anion aggregates of several ionic liquids. Close mobilities were observed in a T-wave cell filled with helium at ca. 0.8 mbar for [(DAI)(n+1)(X)(n)](+) (DAI is the 1,3-dialkylimidazolium cation and X is the anion) as compared to the respective anions [(DAI)(n)(X)(n+1)](-) for n=0 to 9. The anomalous behavior reported before in the condensed phase seems therefore to be related to the unique structural organization of pure ionic liquids that provides both polar and non-polar regions with directionality in which the anionic species are more retained than the cationic species in the salt network.

12.
Anal Chim Acta ; 659(1-2): 15-22, 2010 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-20103102

RESUMO

The desorption and ionization of analytes directly from surfaces or natural matrices under ambient conditions has greatly simplified chemical analysis by mass spectrometry. Among the currently available set of such techniques, easy ambient sonic-spray ionization (EASI) is one of the simplest and most easily implemented. Fuels are among the most important and most complex classes of chemical mixtures and a challenge for fast and comprehensive chemical analysis. This review summarizes the applications of EASI-MS for fast, simple and nearly sample-preparation-free analysis of various fuels, focusing in typification, adulteration and quality control.

13.
Analyst ; 134(8): 1652-7, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20448934

RESUMO

High performance thin layer chromatography (HPTLC) combined with on-spot detection and characterization via easy ambient sonic-spray ionization mass spectrometry (EASI-MS) is applied to the analysis of biodiesel (B100) and biodiesel-petrodiesel blends (BX). HPTLC provides chromatographic resolution of major components whereas EASI-MS allows on-spot characterization performed directly on the HPTLC surface at ambient conditions. Constituents (M) are detected by EASI-MS in a one component-one ion fashion as either [M + Na](+) or [M + H](+). For both B100 and BX samples, typical profiles of fatty acid methyl esters (FAME) detected as [FAME + Na](+) ions allow biodiesel typification. The spectrum of the petrodiesel spot displays a homologous series of protonated alkyl pyridines which are characteristic for petrofuels (natural markers). The spectrum for residual or admixture oil spots is characterized by sodiated triglycerides [TAG + Na](+). The application of HPTLC to analyze B100 and BX samples and its combination with EASI-MS for on-spot characterization and quality control is demonstrated.


Assuntos
Biocombustíveis/análise , Cromatografia em Camada Fina/métodos , Espectrometria de Massas/métodos , Fontes de Energia Bioelétrica/classificação , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas/instrumentação , Preparações Farmacêuticas/análise , Espectrometria de Massas por Ionização por Electrospray
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA