Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-35742510

RESUMO

The development of an environmentally friendly analytical technique for simultaneous measurement of medicines with large concentration differences is difficult yet critical for environmental protection. Hence, in this work, new manipulated UV-spectroscopic methods with high scaling factors were established for concurrent quantification of telmisartan (TEL) and benidipine (BEN) in fixed-dose combinations. Two different methods were developed and established by calculation of peak height at zero crossing point of second derivative and the ratio of first derivative spectra with a scaling factor of 200 and 100, respectively. The absorption difference between the peaks and troughs of the ratio spectra, as well as continuous subtraction from ratio spectra, were established as additional methods. In addition, new procedures were validated using ICH recommendations. The proposed methods' linearity curves were constructed in the range of 0.5-10 µg mL-1 and 1-30 µg mL-1 for BEN and TEL, respectively, under optimized conditions. Furthermore, both the detection (0.088-0.139 µg mL-1 for BEN and 0.256-0.288 µg mL-1 for TEL) and quantification limits (0.293-0.465 µg mL-1 for BEN and 0.801-0.962 µg mL-1 for TEL) were adequate for quantifying both analytes in the formulation ratios. The accuracy and precision were confirmed by the good recovery percent (98.37%-100.6%), with low percent relative error (0.67%-1.70%) and less than 2 percent relative standard deviation, respectively. The specificity of the methods was proven by accurate and precise outcomes from the standard addition method and analysis of laboratory mixed solutions with large differences in concentrations of both analytes. Finally, the BEN and TEL content of the formulations was determined simultaneously without prior separation using these first ever reported spectroscopic methods. Furthermore, developed UV derivative spectroscopic methods demonstrated high greenness and whiteness when compared to the reported HPLC methods. These findings show that the projected methods were effective, practical, and environmentally acceptable for quality control of BEN and TEL in multicomponent formulations.


Assuntos
Cromatografia Líquida de Alta Pressão , Cromatografia Líquida de Alta Pressão/métodos , Di-Hidropiridinas , Controle de Qualidade , Espectrofotometria/métodos , Telmisartan
2.
Molecules ; 27(10)2022 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-35630608

RESUMO

A rapid and reproducible hydrophilic liquid chromatography (HILIC) process was established for concomitant determination of remogliflozin etabonate (RE), vildagliptin (VD), and metformin (MF) in a formulation. A face-centered central composite experimental design was employed to optimize and predict the chromatographic condition by statistically studying the surface response model and design space with desirability close to one. A HILIC column with a simple mobile phase of acetonitrile (65% v/v) and 20 mM phosphate buffer (35% v/v, pH 6, controlled with orthophosphoric acid) was used to separate RE, VD, and MF. RE, VD, and MF were separated in 3.6 min using an isocratic mode mobile phase flow at a flow rate of 1.4 mL at room temperature, and the analytes were examined by recording the absorption at 210 nm. The developed HILIC method was thoroughly validated for all parameters recommended by ICH, and linearity was observed in the ranges 20−150 µg/mL, 10−75 µg/mL, and 50−750 µg/mL for RE, VD, and MF, respectively, along with excellent regression coefficients (r2 > 0.999). The calculated percentage relative deviation and relative error ascertained the precision and accuracy of the method. The selectivity and accuracy were further confirmed by the high percentage recovery of added standard drugs to the formulation using the standard addition technique. The robustness of the HILIC processes was confirmed by developing a half-normal probability plot and Pareto chart, as the slight variation of a single factor had no significant influence on the assay outcomes. Utilization of the optimized HILIC procedure for concurrent quantification of RE, VD, and MF in solid dosage forms showed accurate and reproducible results. Hence, the fast HILIC method can be regularly employed for the quality assurance of pharmaceutical preparations comprising RE, VD, and MF.


Assuntos
Hipoglicemiantes , Metformina , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Metformina/química , Controle de Qualidade , Projetos de Pesquisa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA