Heart Lung Circ ; 31(8): 1054-1063, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35760743

RESUMO

Recognising the need for a national approach for the recommended best practice for the follow-up of implanted cardiac rhythm devices to ensure patient safety, this document has been produced by the Cardiac Society of Australia and New Zealand (CSANZ). It draws on accepted practice standards and guidelines of international electrophysiology bodies. It lays out methodology, frequency, and content of follow-up, including remote monitoring; personnel, including physician, allied health, nursing and industry; paediatric and adult congenital heart patients; and special considerations including magnetic resonance imaging scanning, perioperative management, and hazard alerts.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Adulto , Austrália , Criança , Eletrônica , Seguimentos , Humanos , Nova Zelândia
2.
Heart Asia ; 11(1): e011162, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31031836

RESUMO

OBJECTIVE: Data describing outcomes after implantable cardioverter-defibrillator (ICD) unit generator replacement in patients with heart failure (HF) with primary prevention devices are limited. METHOD: Data on patients with HF who underwent primary prevention ICD/cardiac resynchronisation therapy-defibrillator (CRT-D) implantation from 2007 until mid-2015 who subsequently received unit generator replacement were analysed. Outcomes assessed were mortality, appropriate ICD therapy and shock, and procedural complications. RESULTS: 61 of 385 patients with HF with primary prevention ICD/CRT-D undergoing unit generator replacement were identified. Follow-up period was 1.8±1.5 years after replacement. 43 (70.5%) patients had not received prior appropriate ICD therapy prior to unit replacement. The cumulative risks of appropriate ICD therapy at 1, 3 and 5 years after unit replacement in those without prior ICD therapy were 0%, 6.2% and 50% compared with 6.2%, 59.8% and 86.6%, respectively (p=0.005) in those with prior ICD therapies. No predictive factors associated with appropriate ICD therapy after replacement could be identified. 41 (32.8%) patients no longer met guideline indications at the time of unit replacement but risks of subsequent appropriate ICD interventions were not different compared with those who continued to meet primary prevention ICD indications.The 5-year mortality risk after unit replacement was 18.4% and there were high procedural complication rates (9.8%). CONCLUSION: No predictive marker successfully stratified patients no longer needing ICD support prospectively. Finding such a marker is important in decision-making about device replacement particularly given the concerns about the complication rates. These factors should be considered at the time of ICD unit replacement.

3.
J Arrhythm ; 35(1): 52-60, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30805044

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) has been shown to improve morbidity and mortality for heart failure (HF) patients. Little is known about the trends in CRT use and outcomes of these patients in New Zealand. METHOD: Mortality, hospitalization events and complications in HF patients in the Northern Region of New Zealand implanted with CRT devices from Jan-2007 to June-2015 were reviewed. RESULTS: Two-hundred patients underwent CRT implantation during the study period. There was a gradual increase in CRT-D implantation (n = 157) but the number remained static for CRT-P (n = 43). Patients who received CRT-P were older (mean age 65.9 ± 14.0 years vs 61.5 ± 10.2 years, P < 0.0007) but had a higher left ventricular ejection fraction (LVEF) (33.7 ± 10.5% vs 24.7 ± 6.1%, P < 0.0001) than those undergoing CRT-D implant procedures. During a median follow-up of 4 (2.8) years, 29 (14.5%) patients (14.7% in CRT-D vs 13.9% in CRT-P, P = 0.91) had died. HF was the cause of death in 73.9% of the patients. There was no difference in all-cause mortality between patients with CRT-D and CRT-P. CONCLUSIONS: Despite the proven benefits of CRT in selected HF patients, there continued to be under-utilization of these devices in HF patients in the Northern Region. Reasons for under-utilization of these devices need further exploration. These data should be useful for benchmarking individual patient management and national practice against wider experience in the country.

4.
J Arrhythm ; 34(1): 46-54, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29721113

RESUMO

BACKGROUND: Implantable cardioverter-defibrillator (ICD) therapy is indicated for selected heart failure patients for the primary prevention of sudden cardiac death. Little is known about the outcomes in patients selected for primary prevention device therapy in the northern region of New Zealand. METHOD: Heart failure patients with systolic dysfunction who underwent primary prevention ICD/cardiac resynchronization therapy-defibrillator (CRT-D) implantation between January 1, 2007, and June 1, 2015, were included. Complications, mortality, and hospitalization events were reviewed. RESULTS: Three hundred and eighty-five primary prevention devices were implanted (269 ICD, 116 CRT-D). Mean age at implant was 59.1 ± 11.4 years. Mean duration of follow-up was 3.64 ± 2.17 years. The commonest cause of death was heart failure (41.8%). Only 2 patients died from sudden arrhythmic death. The 5-year heart failure mortality rate was 6%, whereas the 5-year sudden arrhythmic death rate was 0.3%. Heart failure hospitalizations were commoner in those who received ICD than CRT-D (67.7% vs 25.8%, P < .001). Maori patients have low implant rates (14%) with relatively high rates of admissions with heart failure and ventricular arrhythmia admissions. CONCLUSIONS: Even in appropriately selected heart failure patients who received primary prevention devices, only a small percentage died as a result of sudden arrhythmic death. CRT-D should be the device of choice where appropriate in heart failure patients. Significant challenges remain to improve access to device therapy and maximize benefit to those who do get implanted.

5.
Heart Asia ; 10(1): e010985, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29422952

RESUMO

OBJECTIVE: Women have been under-represented in randomised clinical trials for primary prevention implantable cardioverter defibrillators (ICDs), and there are concerns about the efficacy of devices between genders. Our study aimed to investigate gender differences in the use of primary prevention ICD in patients with heart failure from the northern region of New Zealand. METHODS: Patients with heart failure with systolic dysfunction who received primary prevention ICD/cardiac resynchronisation therapy-defibrillator (CRT-D) in the northern region of New Zealand from 1 January 2007 to 1 June 2015 were included. Complications, mortality and hospitalisation events were reviewed. RESULTS: Of the 385 patients with heart failure implanted with ICD/CRT-D, women comprised 15.1% (n=58), and no change in utilisation of these devices was observed over the study period among women. Women were more likely to have non-ischaemic cardiomyopathy and have higher perioperative complications (8.6% vs 2.5%, P=0.02), with non-significant higher trend towards increased lead displacement (5.2% vs 1.8%, P=0.12). Women appeared to have lower all-cause (10.3% vs 18.7%, P=0.12), cardiovascular (5.2% vs 11.9%, P=0.13) and heart failure (3.5% vs 7.9%, P=0.22) mortalities but was not statistically significant. There were no gender differences in all-cause (70.7% vs 67%, P=0.58) or heart failure (19% vs 25%, P=0.32) readmissions. CONCLUSION: Perioperative complications were significantly more common in women referred for ICD/CRT-D. Although there has been a significant increase in ICD implantation rates, gender differences in the use of these devices still exist in New Zealand, in keeping with the demographics of ischaemic heart disease and systolic dysfunction between genders.

6.
PLoS One ; 12(3): e0171069, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28358801

RESUMO

BACKGROUND: Increased spatial QRS-T angle has been shown to predict appropriate implantable cardioverter defibrilIator (ICD) therapy in patients with left ventricular systolic dysfunction (LVSD). We performed a retrospective cohort study in patients with left ventricular ejection fraction (LVEF) 31-40% to assess the relationship between the spatial QRS-T angle and other advanced ECG (A-ECG) as well as echocardiographic metadata, with all-cause mortality or ICD implantation for secondary prevention. METHODS: 534 patients ≤75 years of age with LVEF 31-40% were identified through an echocardiography reporting database. Digital 12-lead ECGs were retrospectively matched to 295 of these patients, for whom echocardiographic and A-ECG metadata were then generated. Data mining was applied to discover novel ECG and echocardiographic markers of risk. Machine learning was used to develop a model to predict possible outcomes. RESULTS: 49 patients (17%) had events, defined as either mortality (n = 16) or ICD implantation for secondary prevention (n = 33). 72 parameters (58 A-ECG, 14 echocardiographic) were univariately different (p<0.05) in those with vs. without events. After adjustment for multiplicity, 24 A-ECG parameters and 3 echocardiographic parameters remained different (p<2x10-3). These included the posterior-to-leftward QRS loop ratio from the derived vectorcardiographic horizontal plane (previously associated with pulmonary artery pressure, p = 2x10-6); spatial mean QRS-T angle (134 vs. 112°, p = 1.6x10-4); various repolarisation vectors; and a previously described 5-parameter A-ECG score for LVSD (p = 4x10-6) that also correlated with echocardiographic global longitudinal strain (R2 = - 0.51, P < 0.0001). A spatial QRS-T angle >110° had an adjusted HR of 3.4 (95% CI 1.6 to 7.4) for secondary ICD implantation or all-cause death and adjusted HR of 4.1 (95% CI 1.2 to 13.9) for future heart failure admission. There was a loss of complexity between A-ECG and echocardiographic variables with an increasing degree of disease. CONCLUSION: Spatial QRS-T angle >110° was strongly associated with arrhythmic events and all-cause death. Deep analysis of global ECG and echocardiographic metadata revealed underlying relationships, which otherwise would not have been appreciated. Delivered at scale such techniques may prove useful in clinical decision making in the future.


Assuntos
Cardiomiopatias/fisiopatologia , Ecocardiografia , Insuficiência Cardíaca/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Cardiomiopatias/mortalidade , Cardiomiopatias/terapia , Mineração de Dados , Morte Súbita Cardíaca , Desfibriladores Implantáveis , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Humanos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/terapia