Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Int J Orthop Trauma Nurs ; 54: 101100, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38626558

RESUMO

PURPOSE: Investigate efficacy of reduced compression bandage for the control of pain after total knee arthroplasty. PATIENTS & METHODS: Prospective, single-centre, randomised controlled trial involving data for 56 out of 94 consented patients; 29 standard care versus 27 Andoflex TLC Calamine Lite. Comparison of standard care (non-compression bandage applied for up to one day) versus Andoflex TLC Calamine Lite (25-30 mmHg) two-layer compression bandage worn for five days. Outcomes measured with validated pain (McGill, 10-cm visual scale) and functionality (KOOS) tools. RESULTS: At day 5 post-surgery, the median pain level was 3.0 cm vs 4.0 cm (p-value 0.47, Mann-Whitney U test) respectively. Generic pain levels, pain types, and knee functionality did not differ between the interventions at days 3/5/12 and week 6 post-surgery. An exception was the degree of 'tender' pain at day 12, which was significantly lower in the Andoflex TLC Calamine Lite arm (p-value 0.041, Mann-Whitney U test). Binary logistic regression analysis showed that application of Andoflex TLC Calamine Lite, administration of oxycodone, and male sex were all significantly associated with less 'tender' pain. CONCLUSION: Reduced compression bandaging does not affect overall pain levels post knee arthroplasty surgery, but may alleviate pain experienced as 'tender', highlighting the different types of pain that may be experienced. Patients' need for, and the use of, opioid medication (oxycodone) is a significant confounding variable when assessing adjuvant therapy to control pain. The applicability of reduced compression bandaging may therefore be limited and is less efficient than medical pain control.


Assuntos
Artroplastia do Joelho , Bandagens Compressivas , Medição da Dor , Dor Pós-Operatória , Humanos , Artroplastia do Joelho/efeitos adversos , Masculino , Feminino , Dor Pós-Operatória/prevenção & controle , Idoso , Pessoa de Meia-Idade , Estudos Prospectivos , Manejo da Dor/métodos , Resultado do Tratamento , Idoso de 80 Anos ou mais
2.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 1000-1007, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38469916

RESUMO

PURPOSE: Current evidence around the management of osteotomy-related infection is insufficient to robustly underpin the expert statements formulated by a recent European consensus statement. We present a review of a large case series in a high-volume osteotomy practice to contribute to the understanding of the incidence, management and outcome of infection in this subspecialty area. METHODS: Analyses of two prospectively collected databases for all osteotomy around the knee and infections related to osteotomy were performed, along with a review of hospital readmission data to capture all osteotomy-related infections. Clinical notes were reviewed to assess patient demographics, incidence of infection, how infection was managed and clinical outcome. RESULTS: In a series of 822 osteotomies in 755 patients, there were 21 (2.8%) cases of suspected infection. Twelve (1.6%) were contemporaneously deemed 'superficial' and nine confirmed 'deep' infections (1.2%). Deep infections were all successfully managed with wound debridement, with or without plate removal, depending on union and time from initial surgery. One of these infections was noted during a revision procedure, but no revision was carried out as a direct result of infection, no external fixation was required and no infected nonunions were experienced. CONCLUSION: All of the cases in this series were managed successfully with debridement ± removal of the plate, without the need for revision or external fixation. Any potential signs of infection around an osteotomy, especially in the case of medial high tibial osteotomy, should raise awareness for deep infection and the need for further surgery due to the limited overlying soft tissue cover. This evidence supports the recent European Society of Sports Traumatology, Knee Surgery and Arthroscopy algorithm. LEVEL OF EVIDENCE: Level IV, case series.


Assuntos
Osteoartrite do Joelho , Tíbia , Humanos , Incidência , Tíbia/cirurgia , Articulação do Joelho/cirurgia , Joelho , Osteoartrite do Joelho/cirurgia , Osteotomia/efeitos adversos , Osteotomia/métodos , Estudos Retrospectivos , Resultado do Tratamento
3.
Commun Biol ; 6(1): 846, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37582968

RESUMO

A biological understanding of the apparent sex bias in autism is lacking. Here we have identified Cntnap2 KO mice as a model system to help better understand this dimorphism. Using this model, we observed social deficits in juvenile male KO mice only. These male-specific social deficits correlated with reduced spine densities of Layer 2/3 and Layer 5 pyramidal neurons in the Anterior Cingulate Cortex, a forebrain region prominently associated with the control of social behaviour. Furthermore, in male KO mice, microglia showed an increased activated morphology and phagocytosis of synaptic structures compared to WT mice, whereas no differences were seen in female KO and WT mice. Our data suggest that sexually dimorphic microglial activity may be involved in the aetiology of ASD, disrupting the development of neural circuits that control social behaviour by overpruning synapses at a developmentally critical period.


Assuntos
Microglia , Caracteres Sexuais , Camundongos , Masculino , Feminino , Animais , Giro do Cíngulo , Camundongos Knockout , Comportamento Social
5.
Knee ; 33: 73-83, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34562741

RESUMO

BACKGROUND: There are significant deficiencies in the evidence base of modern-day osteotomy which result in significant variation in practice between surgeons. The purpose of this statement was to develop a consensus statement on the practice of osteotomy so that a more standardized approach to the indications, surgical technique, and postoperative care could be outlined. The article is also intended to educate and inform the practice of individuals who are early in their experience and/or clinical practice. METHOD: A group of 29 specialist knee surgeons who regularly perform osteotomy was convened to form the Knee Osteotomy consensus Group (KOG). Consensus was determined utilizing the consensus group technique described by List. A total of 37 questions were asked covering all aspects of clinical practice. RESULTS: 20 statements were generated and debated until a criterion level of 70% was met. CONCLUSIONS: Consensus was achieved regarding 20 statements concerning Indications for surgery, decision making, surgical planning, technique, post-operative assessment and recovery.


Assuntos
Osteotomia , Tíbia , Consenso , Humanos , Articulação do Joelho/cirurgia , Reino Unido
6.
Indian J Orthop ; 55(4): 967-973, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34194655

RESUMO

PURPOSE: Assessing surgical accuracy and patient-recorded outcome measures for patients fitted with either the OPTY-LINE intramedullary realignment system or the Tomofix plate for medial opening wedge high tibial osteotomy (HTO). PATIENTS AND METHODS: Two matched case series of patients with symptomatic medial compartment osteoarthritis without other significant knee pathology. One group comprised of 19 patients receiving the Tomofix plate, whereas another comprised of 12 patients receiving the OPTY-LINE intramedullary nail. Patella-centred long leg alignment radiographs were assessed to calculate surgical accuracy in all cases. Patients completed knee injury osteoarthritis outcome scores (KOOS) and osteotomy surgery patient satisfaction questionnaires pre-operatively and at 24 months post-surgery. RESULTS: Absolute surgical accuracy at 2 years post-surgery was a mean 4.2 [standard deviation 3.7] for OPTY-LINE versus 9.2 [SD 7.8] for Tomofix (p = 0.11, Mann-Whitney U test). On average, patients in either the OPTY-LINE or Tomofix cohort reported at least a minimal perceptible clinical improvement-minimum average improvement of 15-for all five KOOS themes. No significant difference in change of KOOS scores over time or patient satisfaction levels were observed between the two cohorts. CONCLUSION: The OPTY-LINE device for HTO performs to a similar level as the Tomofix device. Surgical accuracy data are promising for OPTY-LINE, but does not seem to readily translate into difference in patient-reported outcomes compared to Tomofix. Even longer follow-up periods, to measure survival rates, and true randomised trials on larger samples can elucidate if there is a benefit for using one device over the other.

7.
Int J Orthop Trauma Nurs ; 42: 100833, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33531268

RESUMO

PURPOSE: To assess if application of dual-layer compression bandage to osteotomy patients post-surgery can positively influence levels of post-operative pain and swelling. PATIENTS & METHODS: Prospective, single-centre, randomised controlled trial comparing standard care, non-compression bandaging, versus Coban™ 2 (3M). Seven day application of the latter to index leg of osteotomy patients. RESULTS: Primary outcome data was available for 36 out of 49 study subjects (18 standard care versus 18 Coban™ 2 subjects). Median 10-cm scale pain levels showed a statistically non-significant difference at day 5 and day 12 post-surgery between standard care and Coban™ 2 respectively: 5.5 cm vs 2.5 cm (p-value 0.068) and 4.0 cm vs 2.3 cm (p-value 0.39). However, on day 12 (p-value 0.029) and week 6 (p-value 0.027), 'throbbing pain' was significantly higher for Coban™ 2 patients. Changes in limb swelling measures, comparing before and after the surgical procedure, did not differ between treatment arms. Compression led to more patients reporting bandage-related discomfort (6% standard care versus 63% Coban™ 2 patients). CONCLUSION: Compression bandaging changes the post-surgery pain profile in osteotomy patients, but does not reduce leg swelling. Any subsequent leg compression trials must take into account patient comfort and titrate intervention length and compression rates.


Assuntos
Bandagens Compressivas , Dor Pós-Operatória , Humanos , Osteotomia , Dor Pós-Operatória/prevenção & controle , Estudos Prospectivos , Resultado do Tratamento
8.
J Orthop Surg (Hong Kong) ; 27(3): 2309499019864721, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31379259

RESUMO

PURPOSE: The objective was to evaluate the clinical and patient-related short- to medium-term performance of the OPTY-LINE nail device for high tibial osteotomy (HTO), comparing a case series of the said device to the established Tomofix fixed-plate device. PATIENTS AND METHODS: Males with symptomatic medial compartmental osteoarthritis and no serious (co-morbid) knee pathology were followed up, five Tomofix and six OPTY-LINE patients. Patients underwent computed tomography assessment and completed Knee Injury and Osteoarthritis Outcome score (KOOS) and osteotomy surgery patient satisfaction questionnaires, 3 and 6 months post-surgery. A radiologist impression score and a quantitative digital bone density analysis were performed by two independent radiologists. Mann-Whitney U test was applied for inferential statistical tests. RESULTS: At 6 months post-surgery, for Tomofix, the median radiologists' healing impression score was 'progressive healing' versus 'union virtually complete' for the OPTY-LINE nail; bone healing quotient was 1.30 (standard deviation (SD) 1.74) versus 1.78 (SD 1.58), p = 0.18. The post-operative absolute surgical accuracy was a mean 12 (7.5) for Tomofix versus 4.1 (2.3) for OPTY-LINE, p = 0.052. At baseline, however, Tomofix patients had more knee symptoms, as determined by KOOS symptom sub-score, when compared to the OPTY-LINE cohort (p = 0.009). CONCLUSION: This initial, non-randomized, comparative evaluation of the OPTY-LINE device for HTO has produced similar outcomes to patients treated with the established Tomofix device. In particular, the rate of post-surgical bone regeneration and surgical accuracy achieved with the OPTY-LINE device are encouraging. Large-scale randomized controlled studies with longer follow-up are indicated to further evaluate the clinical and patient-related outcome performance for OPTY-LINE.


Assuntos
Placas Ósseas , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Osteotomia/métodos , Cirurgia Assistida por Computador/instrumentação , Tíbia/cirurgia , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Período Pós-Operatório , Estudos Prospectivos , Tomografia Computadorizada por Raios X
11.
Acad Emerg Med ; 21(11): 1297-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25377415

RESUMO

OBJECTIVES: The objective of this study was to determine the feasibility of telementored instruction in bedside ultrasonography (US) using Google Glass. The authors sought to examine whether first-time US users could obtain adequate parasternal long axis (PSLA) views to approximate ejection fraction (EF) using Google Glass telementoring. METHODS: This was a prospective, randomized, single-blinded study. Eighteen second-year medical students were randomized into three groups and tasked with obtaining PSLA cardiac imaging. Group A received real-time telementored education through Google Glass via Google Hangout from a remotely located expert. Group B received bedside education from the same expert. Group C represented the control and received no instruction. Each subject was given 3 minutes to obtain a best PSLA cardiac imaging using a portable GE Vscan. Image clips obtained by each subject were stored. A second expert, blinded to instructional mode, evaluated images for adequacy and assigned an image quality rating on a 0 to 10 scale. RESULTS: Group A was able to obtain adequate images six out of six times (100%) with a median image quality rating of 7.5 (interquartile range [IQR] = 6 to 10) out of 10. Group B was also able to obtain adequate views six out of six times (100%), with a median image quality rating of 8 (IQR = 7 to 9). Group C was able to obtain adequate views one out of six times (17%), with a median image quality of 0 (IQR = 0 to 2). There were no statistically significant differences between Group A and Group B in the achievement of adequate images for E-point septal separation measurement or in image quality. CONCLUSIONS: In this pilot/feasibility study, novice US users were able to obtain adequate imaging to determine a healthy patient's EF through telementored education using Google Glass. These preliminary data suggest telementoring as an adequate means of medical education in bedside US. This conclusion will need to be validated with larger, more powerful studies including evaluation of pathologic findings and varying body habitus among models.


Assuntos
Cardiologia/educação , Ecocardiografia , Educação Médica/métodos , Cardiopatias/diagnóstico por imagem , Internet/instrumentação , Avaliação Educacional , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Projetos Piloto , Estudos Prospectivos , Reprodutibilidade dos Testes , Método Simples-Cego
12.
Orthopedics ; 35(11): e1668-72, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23127463

RESUMO

Chronic patellar dislocation is a rare condition where the patella remains dislocated throughout knee range of motion during flexion and extension. In adults, the delayed presentation of this condition is often due to symptoms caused by the onset of severe secondary osteoarthritis. To the authors' knowledge, all of the cases reported in the literature have been treated by patellofemoral or total knee replacements depending on patient age and the extent of the arthritis. This article describes a rare case of a 22-year-old woman who sustained a traumatic chronic patellar dislocation for 5 months. Clinical examination revealed a valgus deformity of the left leg secondary to childhood injury and that the patella lay lateral to the lateral femoral condyle throughout flexion and extension. Radiographs of the knee revealed patellar dislocation. Long-leg radiographs of the left leg showed an anatomic tibiofemoral angle of 17° valgus. The anatomical (74°) and mechanical (80°) lateral distal femoral angles were abnormal, whereas the medial proximal tibial angle (87°) was normal, confirming that the valgus deformity was due to the abnormal distal femur. The authors performed a distal femoral osteotomy to correct the valgus deformity. Medial patellofemoral ligament reconstruction using a hamstring autograft was performed to stabilize the patella.


Assuntos
Fêmur/cirurgia , Osteotomia/métodos , Luxação Patelar/cirurgia , Ligamento Patelar/cirurgia , Articulação Patelofemoral/lesões , Articulação Patelofemoral/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Feminino , Humanos , Resultado do Tratamento , Adulto Jovem
13.
Int J Emerg Med ; 3(4): 265-9, 2010 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-21373291

RESUMO

BACKGROUND: Because of the Accreditation Council for Graduate Medical Education (ACGME) and the Residency Review Committee (RRC) approval timelines, new residency programs cannot use Electronic Residency Application Service (ERAS) during their first year of applicants. AIM: We sought to identify differences between program directors' subjective ratings of applicants from an emergency medicine (EM) residency program's first year (in which ERAS was not used) to their ratings of applicants the following year in which ERAS was used. METHOD: The University of Utah Emergency Medicine Residency Program received approval from the ACGME in 2004. Applicants for the entering class of 2005 (year 1) did not use ERAS, submitting a separate application, while those applying for the following year (year 2) used ERAS. Residency program directors rated applicants using subjective components of their applications, assigning scores on scales from 0-10 or 0-5 (10 or 5 = highest score) for select components of the application. We retrospectively reviewed and compared these ratings between the 2 years of applicants. RESULTS: A total of 130 and 458 prospective residents applied during year 1 and year 2, respectively. Applicants were similar in average scores for research (1.65 vs. 1.81, scale 0-5, p = 0.329) and volunteer work (5.31 vs. 5.56, scale 0-10, p = 0.357). Year 1 applicants received higher scores for their personal statement (3.21 vs. 2.22, scale 0-5, p < 0.001), letters of recommendation (7.0 vs. 5.94, scale 0-10, p < 0.001), dean's letter (3.5 vs. 2.7, scale 1-5, p < 0.001), and in their potential contribution to class characteristics (4.64 vs. 3.34, scale 0-10, p < 0.001). CONCLUSION: While the number of applicants increased, the use of ERAS in a new residency program did not improve the overall subjective ratings of residency applicants. Year 1 applicants received higher scores for the written components of their applications and in their potential contributions to class characteristics.

14.
Ann R Coll Surg Engl ; 90(6): 483-7, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18765028

RESUMO

INTRODUCTION: Ankle fractures are common and 'stable' ankle fractures comprise 40-75% of this group. Studies show that these injuries can be managed successfully in a functional brace, with no need for further radiographs and minimal out-patient follow-up. We aimed to audit current practice and introduce change in order to improve treatment and produce financial savings. PATIENTS AND METHODS: A retrospective 6-month audit was carried out to establish practice. Guidelines were then drawn up and widely distributed in the accident and emergency (A&E) and orthopaedic departments. These included criteria for diagnosis of stable ankle fractures, a management protocol for treatment of these injuries in a brace and also a follow-up algorithm in the out-patient clinic. A prospective 6-month audit was then carried out to assess the effectiveness of the guidelines. RESULTS: Of patients presenting in the second 6-month period, 91% were managed in a functional brace. The mean number of out-patient follow-up appointments, weeks until discharge and repeat radiographs all decreased significantly (P < 0.05) after the implementation of the guidelines. The cost of treating a patient with a stable ankle fracture dropped from 310.75 pounds to 129.80 pounds. CONCLUSIONS: Previous studies have shown that stable ankle fractures are more effectively treated in a functional brace than a plaster cast, do not displace and, therefore, do not need repeat radiographs. A previous audit demonstrated that 60% of patients with stable fractures could be treated in a brace. We have shown that, with effective and persistent education of colleagues, the vast majority (91%) of patients can be managed in this way and this results in a significant cost saving. We have also shown that an evidence-based treatment protocol can produce significant improvements in management for patients and savings for healthcare organisations.


Assuntos
Traumatismos do Tornozelo/terapia , Fraturas Ósseas/terapia , Traumatismos do Tornozelo/economia , Auditoria Clínica , Análise Custo-Benefício , Feminino , Fraturas Ósseas/economia , Humanos , Masculino , Pessoa de Meia-Idade , Aparelhos Ortopédicos/economia , Estudos Prospectivos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA