1.
Int J Biol Markers ; 10(2): 67-74, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7561241

RESUMO

Host development of human anti-mouse antibodies (HAMA) in response to administered antibodies has been reported as a problem for antibody imaging and therapy. However, radioimmunotherapy has been shown to be effective in patients with B-cell malignancies because their immunodeficient state precludes or delays development of a HAMA response to mouse antibodies. Baseline HAMA activity was assayed in 60 patients with B-lymphocytic non-Hodgkin's lymphoma or chronic lymphocytic leukemia and sequentially in 43 patients who were subsequently treated with radiolabeled Lym-1 antibody. Pre-existing "HAMA" activity was found in 3 (5%) of the 60 patients screened for treatment consideration. The incidence of development of HAMA in the 43 patients treated with multiple doses of radiolabeled Lym-1 antibody was 12 (28%). There was no evidence for an anaphylactoid or related response in the HAMA positive patients. HAMA activity interrupted therapy in 14% of the patients (6 of 43) but did not preclude therapeutic responses to radiolabeled Lym-1 therapy. Medial survival for the HAMA positive patients was longer (18 months) than for those who did not develop HAMA activity (9 months).


Assuntos
Anticorpos Anti-Idiotípicos/biossíntese , Anticorpos Monoclonais/imunologia , Anticorpos Antineoplásicos/imunologia , Leucemia Linfocítica Crônica de Células B/imunologia , Linfoma de Células B/imunologia , Camundongos/imunologia , Radioimunoterapia/efeitos adversos , Adulto , Idoso , Animais , Anticorpos Anti-Idiotípicos/imunologia , Anticorpos Monoclonais/uso terapêutico , Anticorpos Antineoplásicos/uso terapêutico , Linfócitos B/imunologia , Feminino , Humanos , Imunização , Radioisótopos do Iodo/administração & dosagem , Radioisótopos do Iodo/uso terapêutico , Leucemia Linfocítica Crônica de Células B/mortalidade , Leucemia Linfocítica Crônica de Células B/radioterapia , Linfoma de Células B/mortalidade , Linfoma de Células B/radioterapia , Masculino , Pessoa de Meia-Idade , Especificidade da Espécie , Análise de Sobrevida , Resultado do Tratamento
2.
Semin Nucl Med ; 19(3): 221-37, 1989 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-2669130

RESUMO

This review describes the use of monoclonal antibodies (MoAbs) for immunoscintigraphic detection of thrombosis and thromboembolism. Two major groups of MoAbs have been tested: Antibodies directed against platelets and antibodies directed against fibrin. Several antiplatelet antibodies have been developed that are directed against either the platelet membrane glycoprotein complex, IIb/IIIa, which binds fibrinogen, or against two different proteins, alpha granule membrane protein GMP-140 and thrombospondin (TSP) that are expressed during platelet activation. Platelets labeled with radioactive antibody or antibody fragments have characteristics similar to platelets labeled in vitro with lipophilic complexes. Studies in animal models indicate that antiplatelet antibody and antiactivated platelet factor antibody imaging have a high sensitivity for clots less than 24 hours old and that images can be positive as early as one to two hours after antibody administration. A limited number of antiplatelet antibody studies have been performed in patients. This technique appears to yield accurate results provided that active platelet deposition is occurring at the time of the study. Several antifibrin MoAbs, specific for fibrin monomers, have been developed. Compared with antiplatelet antibodies, antifibrin antibodies and antibody fragments appear to be capable of detecting older experimental clots (up to five days old). Images in experimental thrombosis models are routinely positive within two hours of antibody administration. Recently reported clinical trials indicate a high sensitivity in all anatomic locations within the extremities whether or not patients were receiving heparin.


Assuntos
Anticorpos Monoclonais , Tromboembolia/diagnóstico por imagem , Trombose/diagnóstico por imagem , Animais , Plaquetas/imunologia , Fibrina/imunologia , Humanos , Radioisótopos de Índio , Radioisótopos do Iodo , Marcação por Isótopo , Cintilografia , Tecnécio
3.
Int J Biol Markers ; 3(1): 1-9, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-3249042

RESUMO

In patients or mice with cancer the pharmacokinetic behavior of radioiodinated and radiometal chelated antibodies has been observed to be different. Rapid clearance from the tissues and excretion into the urine can occur after injection of radioiodinated antibodies. These observations have been interpreted to reflect in vivo dehalogenation of the antibody. This publication describes a variety of other mechanisms that can underlie these phenomena. These mechanisms include receptor uptake and catabolism of antibody and instability of the labeled antibody due to the labeling conditions. Specifically, the relative masses of chloramine-T and antibody in the iodination reaction mixture, the level of iodination of the antibody, and the amount of antibody administered to the recipient are all factors which can influence the clearance of radioiodinated antibody from the recipient. The final determinant for the different behavior of radioiodinated and In-111 metal chelated antibody relate to the different biologic pathways of indium when compared to iodine.


Assuntos
Anticorpos Monoclonais/urina , Radioisótopos do Iodo/urina , Marcação por Isótopo/métodos , Compostos de Tosil , Animais , Anticorpos Monoclonais/administração & dosagem , Cloraminas/farmacologia , Cromatografia Líquida de Alta Pressão , Eletroforese em Acetato de Celulose , Humanos , Linfoma/urina , Camundongos , Distribuição Tecidual