Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Cytometry B Clin Cytom ; 106(1): 25-34, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38217297

RESUMO

Since response to antigen-based immunotherapy relies upon the level of tumor antigen expression we developed an antigen quantification assay using ABC values. Antigen quantification as a clinical assay requires methods for quality control and for interlaboratory and inter-cytometer platform standardization. A single lot of Cytotrol™ Lyophilized Control Cells (Beckman Coulter) used for all studies. The variability in antigen quantification across 4 different instrument platforms in 2 separate laboratories was evaluated. The effect of the antibody clone utilized, importance of custom 1:1 molar ratio (fluorophore to protein, F/P) verses off-the-shelf antibodies, and QuantiBrite PE calibration verses linearity calibration combined with a single point scale transformation with CD4 as reference were determined. Use of single lot control cells allowed validation of reproducibility between flow cytometer platforms and laboratories and allowed assessment of different antibody lots, cocktail preparation, and different antibody clones. Off the shelf antibody preparations provide reproducible estimates of antigen density, however custom 1:1 unimolar antibody preparations should be utilized for definitive measurement of antigen expression.Geometric Mean fluorescent Intensity (GeoMFI) was not comparable across instruments and inter-laboratory. The use of CD4 as the reference marker can minimize variability in ABC values. Comparable antigen quantification is vital in managing patients receiving antigen-based immunotherapy. If this assay is to be utilized in a clinical setting, quality control methods have to be instituted to assure reproducibility and allow validation across laboratories. We have demonstrated that use of a lyophilized cell control is highly valuable in achieveing these goals.


Assuntos
Anticorpos , Antígenos , Humanos , Citometria de Fluxo/métodos , Reprodutibilidade dos Testes , Padrões de Referência
2.
Nanomaterials (Basel) ; 12(18)2022 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-36144906

RESUMO

The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques. Diameter values were also measured where possible. The diameter values were found to agree within 20%, but the number concentration values differed by as much as a factor of two. Accuracy and reproducibility related with the different techniques are discussed with the goal of using number concentration standards for instrument calibration. Three of the techniques were used to determine SI-traceable number concentration values, and the three independent values were averaged to give consensus values. This consensus approach is proposed as a protocol for certifying SI-traceable number concentration standards.

3.
Int J Radiat Oncol Biol Phys ; 112(5): 1269-1278, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34963556

RESUMO

PURPOSE: Tumor-treating fields (TTFields) are an antimitotic treatment modality that interfere with glioblastoma (GBM) cell division and organelle assembly by delivering low-intensity, alternating electric fields to the tumor. A previous analysis from the pivotal EF-14 trial demonstrated a clear correlation between TTFields dose density at the tumor bed and survival in patients treated with TTFields. This study tests the hypothesis that the antimitotic effects of TTFields result in measurable changes in the location and patterns of progression of newly diagnosed GBM. METHODS AND MATERIALS: Magnetic resonance images of 428 newly diagnosed GBM patients who participated in the pivotal EF-14 trial were reviewed, and the rates at which distant progression occurred in the TTFields treatment and control arm were compared. Realistic head models of 252 TTFields-treated patients were created, and TTFields intensity distributions were calculated using a finite element method. The TTFields dose was calculated within regions of the tumor bed and normal brain, and its relationship with progression was determined. RESULTS: Distant progression was frequently observed in the TTFields-treated arm, and distant lesions in the TTFields-treated arm appeared at greater distances from the primary lesion than in the control arm. Distant progression correlated with improved clinical outcome in the TTFields patients, with no such correlation observed in the controls. Areas of normal brain that remained normal were exposed to higher TTFields doses compared with normal brain that subsequently exhibited neoplastic progression. Additionally, the average dose to areas of the enhancing tumor that returned to normal was significantly higher than in the areas of the normal brain that progressed to enhancing tumor. CONCLUSIONS: There was a direct correlation between TTFields dose distribution and tumor response, confirming the therapeutic activity of TTFields and the rationale for optimizing array placement to maximize the TTFields dose in areas at highest risk of progression, as well as array layout adaptation after progression.


Assuntos
Antimitóticos , Neoplasias Encefálicas , Terapia por Estimulação Elétrica , Glioblastoma , Antimitóticos/uso terapêutico , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Terapia por Estimulação Elétrica/métodos , Glioblastoma/diagnóstico por imagem , Glioblastoma/radioterapia , Humanos , Imageamento por Ressonância Magnética
4.
Clin Chem ; 67(5): 763-771, 2021 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-33585916

RESUMO

BACKGROUND: Immunoassays for protein analytes measured in situ support a $2 billion laboratory testing industry that suffers from significant interlaboratory disparities, affecting patient treatment. The root cause is that immunohistochemical testing lacks the generally accepted tools for analytic standardization, including reference standards and traceable units of measure. Until now, the creation of these tools has represented an insoluble technical hurdle. METHODS: We address the need with a new concept in metrology-that is, linked traceability. Rather than calculating analyte concentration directly, which has proven too variable, we calculate concentration by measuring an attached fluorescein, traceable to NIST Standard Reference Material 1934, a fluorescein standard. RESULTS: For validation, newly developed estrogen receptor (ER) calibrators were deployed in tandem with an array of 80 breast cancer tissue sections in a national external quality assessment program. Laboratory performance was assessed using both the ER standards and the tissue array. Similar to previous studies, the tissue array revealed substantial discrepancies in ER test results among the participating laboratories. The new ER calibrators revealed a broad range of analytic sensitivity, with the lower limits of detection ranging from 7310 to 74 790 molecules of ER. The data demonstrate, for the first time, that the variable test results correlate with analytic sensitivity, which can now be measured quantitatively. CONCLUSIONS: The reference standard enables precise interlaboratory alignment of immunohistochemistry test sensitivity for measuring cellular proteins in situ. The introduction of a reference standard and traceable units of measure for protein expression marks an important milestone.


Assuntos
Receptores de Estrogênio , Fluoresceínas , Humanos , Imunoensaio , Imuno-Histoquímica , Padrões de Referência
5.
Materials (Basel) ; 13(18)2020 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-32947933

RESUMO

The National Institute of Standards and Technology (NIST), the National Institutes of Health (NIH) and other industry stakeholders have been working together to enable fluorescence intensities of flow cytometer calibration beads to be assigned quantitative equivalent reference fluorophore (ERF) values with high accuracy and precision. The ultimate goal of this effort is to accurately quantify the number of antibodies bound to individual living cells. The expansion of this effort to assign ERF values to more than 50 fluorescence channels and particles with diameters ranging from 10 µm down to 80 nm is reported here.

6.
Nanomedicine (Lond) ; 15(22): 2149-2170, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32885720

RESUMO

Extracellular vesicles (EVs), such as exosomes and microvesicles, are nonreplicating lipid bilayer particles shed by most cell types which have the potential to revolutionize the development and efficient delivery of clinical therapeutics. This article provides an introduction to the landscape of EV-based vectors under development for the delivery of protein- and nucleic acid-based therapeutics. We highlight some of the most pressing measurement and standardization challenges that limit the translation of EVs to the clinic. Current challenges limiting development of EVs for drug delivery are the lack of: standardized cell-based platforms for the production of EV-based therapeutics; EV reference materials that allow researchers/manufacturers to validate EV measurements and standardized measurement systems for determining the molecular composition of EVs.


Assuntos
Exossomos , Vesículas Extracelulares , Ácidos Nucleicos , Sistemas de Liberação de Medicamentos , Padrões de Referência
7.
Int J Mol Sci ; 21(17)2020 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-32846978

RESUMO

A stochastic reaction-diffusion model was developed to describe the binding of labeled monoclonal antibodies (mAbs) to CD4 receptors on the surface of T cells. The mAbs diffused to, adsorbed on, and underwent monovalent and bivalent binding to CD4 receptors on the cell surface. The model predicted the time-dependent nature of all populations involved in the labeling process. At large time, the populations reached equilibrium values, giving the number of antibodies bound to the T cell (ABC) defined as the sum of monovalently and bivalently bound mAbs. The predicted coefficient of variation (CV%) of the (ABC) values translated directly to a corresponding CV% of the measured mean fluorescence intensity (MFI). The predicted CV% was about 0.2% from the intrinsic fluctuations of the stochastic reaction process, about 5% after inclusion of the known fluctuations in the number of available CD4 receptors, and about 11% when fluctuations in bivalent binding affinity were included. The fluorescence detection process is expected to contribute approximately 7%. The abovementioned contributions to CV% sum up to approximately 13%. Work is underway to reconcile the predicted values and the measured values of 17% to 22%.


Assuntos
Anticorpos Monoclonais/metabolismo , Antígenos CD4/metabolismo , Modelos Teóricos , Linfócitos T/metabolismo , Afinidade de Anticorpos , Células Cultivadas , Difusão , Humanos , Ligação Proteica , Processos Estocásticos , Especificidade por Substrato
8.
Biotechniques ; 64(2): 59-68, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-29571283

RESUMO

We compared different methods (absorbance, fluorescent dye-binding, and digital PCR) for measuring the concentrations of human genomic DNA from cultured cells and absorbance measurements of a synthetic DNA oligonucleotide. NIST Standard Reference Material (SRM) 2082, a pathlength absorbance standard, was used to benchmark the absorbance measurements done with microvolume spectrophotometers and a microvolume plate reader. Control absorbance values were measured on a high accuracy spectrophotometer and a NIST calibrated pathlength cuvette. Measurements of the human genomic DNA sample were done with several types of fluorescent dye binding assays using different DNA calibrators. The fluorescent dye binding methods gave different results for genomic DNA depending upon the type of DNA calibrator and the fluorescent dye that was used. The human genomic DNA sample was also characterized by using six different droplet digital PCR assays (amplicons located on different chromosomes) to measure the average copy number. Conversion of the digital PCR data to copy numbers was sensitive to the droplet size used for calculations and conversion to mass concentration was dependent upon the molecular weight of the human genome used for the calculations. The results from the different methods were compared and the caveats for each measurement method were discussed.


Assuntos
DNA/análise , Oligonucleotídeos/análise , Fluorometria , Humanos , Reação em Cadeia da Polimerase , Espectrofotometria
9.
Anal Bioanal Chem ; 410(8): 2127-2139, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29411089

RESUMO

The NISTmAb Reference Material (RM) 8671 is intended to be an industry standard monoclonal antibody for pre-competitive harmonization of best practices and designing next generation characterization technologies for identity, quality, and stability testing. It must therefore embody the quality and characteristics of a typical biopharmaceutical product and be available long-term in a stable format with consistent product quality attributes. A stratified sampling and analysis plan using a series of qualified analytical and biophysical methods is described that assures RM 8671 meets these criteria. Results for the first three lots of RM 8671 highlight the consistency of material attributes with respect to size, charge, and identity. RM 8671 was verified to be homogeneous both within and between vialing lots, demonstrating the robustness of the lifecycle management plan. It was analyzed in concert with the in-house primary sample 8670 (PS 8670) to provide a historical link to this seminal material. RM 8671 was verified to be fit for its intended purpose as a technology innovation tool, external system suitability control, and cross-industry harmonization platform. Graphical abstract The NISTmAb Reference Material (RM) 8671 is intended to be an industry standard monoclonal antibody for pre-competitive harmonization of best practices and designing next generation characterization technologies for identity, quality, and stability testing.


Assuntos
Anticorpos Monoclonais/química , Imunoglobulina G/química , Animais , Medicamentos Biossimilares/química , Cromatografia em Gel/métodos , Cromatografia em Gel/normas , Estabilidade de Medicamentos , Difusão Dinâmica da Luz/métodos , Difusão Dinâmica da Luz/normas , Eletroforese Capilar/métodos , Eletroforese Capilar/normas , Humanos , Microscopia/métodos , Microscopia/normas , Modelos Moleculares , Mapeamento de Peptídeos/métodos , Mapeamento de Peptídeos/normas , Estabilidade Proteica , Controle de Qualidade , Padrões de Referência , Espectrofotometria Ultravioleta/métodos , Espectrofotometria Ultravioleta/normas , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas
10.
Artigo em Inglês | MEDLINE | ID: mdl-34877136

RESUMO

Accurate number concentrations of particles in liquid media are needed to assess the quality of water, pharmaceuticals, and other liquids, yet there are limited reference materials or calibration services available with clear traceability to the International System of Units. We describe two methods, based on very simple modifications of commercial particle counter instruments, that can provide traceable number concentration measurements. One method used a light obscuration counter. Fitting a model to the data enabled correction for timing and coincidence errors, and gravimetric calibration of the syringe pump gave a traceable determination of measured volume. Other potential biases were diagnosed by analysis of the particle size distribution. The other method used a dynamic imaging particle counter (a flow imaging microscope). The instrument was intentionally configured so that each particle passing through the flow cell was imaged multiple times. Following the particle image acquisition runs, runs with a rinse solution released and counted microspheres adsorbed to tubing or flow-cell walls. Software assembled the redundant particle images into tracks, and the total number of tracks was assigned as the number of particles counted. Both light obscuration and dynamic imaging methods, when applied to polystyrene microspheres of approximately 4 µm diameter, achieved expanded uncertainties (k = 2) of approximately 2 % of number concentration and agreed to within a difference of 1.1 %.

11.
Artigo em Inglês | MEDLINE | ID: mdl-34877142

RESUMO

The CD4 glycoprotein is a component of the T cell receptor complex which plays an important role in the human immune response. This manuscript describes the measurement and modeling of the binding of fluorescently labeled anti-human CD4 monoclonal antibodies (mAb; SK3 clone) to CD4 receptors on the surface of human peripheral blood mononuclear cells (PBMC). CD4 mAb fluorescein isothiocyanate (FITC) and CD4 mAb allophycoerythrin (APC) conjugates were obtained from commercial sources. Four binding conditions were performed, each with the same PBMC sample and different CD4 mAb conjugate. Each binding condition consisted of the PBMC sample incubated for 30 min in labeling solutions containing progressively larger concentrations of the CD4 mAb-label conjugate. After the incubation period, the cells were re-suspended in PBS-based buffer and analyzed using a flow cytometer to measure the mean fluorescence intensity (MFI) of the labeled cell populations. A model was developed to estimate the equilibrium concentration of bound CD4 mAb-label conjugates to CD4 receptors on PBMC. A set of parameters was obtained from the best fit of the model to the measured MFI data and the known number of CD4 receptors on PBMC surface. Divalent and monovalent binding had to be invoked for the APC and FITC CD4 mAb conjugates, respectively. This suggests that the mAb binding depends on the size of the label, which has significant implications for quantitative flow cytometry. The study supports the National Institute of Standards and Technology program to develop quantitative flow cytometry measurements.

12.
Biopharm Int ; 31(4): 22-34, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30996711

RESUMO

Ultraviolet (UV) absorbance measurements provide a rapid and reliable method to determine protein concentrations. the National Institute of standards and technology (NIST) has developed Standard Reference Material (SRM) 2082 as a pathlength standard for UV absorbance measurements for use with the new generation of microvolume spectrophotometers and short-pathlength cuvettes. short pathlengths are used with high-concentration targets to ensure that absorbance values are within the optimal range. the short-pathlength instruments and cuvettes also reduce the required volumes to conserve valuable samples. the authors compared the results obtained with high-quality dual-beam spectrophotometers and short-pathlength cuvettes to the results obtained from a microvolume spectrophotometer and a microvolume plate reader. SRM 2082 can be used to accurately calculate pathlength values, thereby increasing the accuracy in subsequent measurements using the short-pathlength cuvettes and microvolume absorbance instruments. RM 8671 (reference material, the NISTmAb) can then be used to ensure the accuracy and reproducibility of protein concentration measurements by providing an industrially relevant reference material, a well-characterized monoclonal antibody.

13.
Artigo em Inglês | MEDLINE | ID: mdl-34877099

RESUMO

New spectrophotometers and cuvettes have been designed to allow the measurement of absorbance values from samples using microliter volume sizes. These measurements are done using short pathlengths to decrease the sample volumes required. The major applications for these spectrophotometers and cuvettes are samples that are difficult to obtain in large amounts, such as proteins and nucleic acids that absorb light in the ultraviolet range. Existing ultraviolet absorbance standards have been designed for longer pathlength measurements. Standard Reference Material (SRM) 2082 was developed to validate the pathlengths of short-pathlength cuvettes and instruments using materials with absorbance spectra that are similar to the most commonly used samples. SRM 2082 consists of three individual components: a blank buffer solution, a solution of the amino acid tryptophan in the buffer, and a solution of the nucleobase uracil in the buffer. The tryptophan solution has an absorbance spectrum (peak at 280 nm) similar to proteins, and the uracil has an absorbance spectrum (peak at 260 nm) similar to nucleic acids. The absorbance values of these solutions were determined using a series of cuvettes with pathlengths from 0.1 mm to 2 mm. The pathlengths of the cuvettes used for the absorbance measurements were determined at the National Institute of Standards and Technology by physical and optical measurements. The effects of temperature and spectral bandwidth variations on the absorbance values of SRM 2082 were also investigated.

14.
J Res Natl Inst Stand Technol ; 121: 264-281, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-34434623

RESUMO

A procedure will be described to assign to each dyed microsphere a number called the Equivalent number of Reference Fluorophores (ERF). The ERF unit gives the number of reference fluorophores in solution which produce the same fluorescence signal as a single dyed microsphere. In the first step, fluorescence measurements were carried out on serial dilutions of a solution of reference fluorophores. The resulting fluorescence intensities and the corresponding concentrations were used to calibrate the response of the fluorometer. The calibration consisted of establishing a linear relation between the intensities and concentrations. In the second step, the fluorescence intensity from a suspension of microspheres was measured in order to determine the equivalent concentration of reference fluorophores which gave the same fluorescence intensity as the suspension of microspheres. This was performed by utilizing the calibration line obtained in the first step. In the third step, a flow cytometer and a light obscuration apparatus were used to measure the total concentration of microspheres in the suspensions used for the fluorescence measurements. In addition to the total microsphere concentration, the flow cytometer also enabled the measurement of the concentration of a sub population of microspheres which are used to calibrate the fluorescence scale of a flow cytometer. The fourth step utilized the data collected in steps one, two, and three to assign a value of ERF to individual microspheres. The set of microspheres with assigned ERF values will be used to establish a linear fluorescence scale in each channel of a flow cytometer. The discussion will emphasize the estimate of uncertainties in each step of the assignment process.

15.
Cytometry A ; 85(11): 978-85, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25132217

RESUMO

Widefield fluorescence microscopy is a highly used tool for visually assessing biological samples and for quantifying cell responses. Despite its widespread use in high content analysis and other imaging applications, few published methods exist for evaluating and benchmarking the analytical performance of a microscope. Easy-to-use benchmarking methods would facilitate the use of fluorescence imaging as a quantitative analytical tool in research applications, and would aid the determination of instrumental method validation for commercial product development applications. We describe and evaluate an automated method to characterize a fluorescence imaging system's performance by benchmarking the detection threshold, saturation, and linear dynamic range to a reference material. The benchmarking procedure is demonstrated using two different materials as the reference material, uranyl-ion-doped glass and Schott 475 GG filter glass. Both are suitable candidate reference materials that are homogeneously fluorescent and highly photostable, and the Schott 475 GG filter glass is currently commercially available. In addition to benchmarking the analytical performance, we also demonstrate that the reference materials provide for accurate day to day intensity calibration. Published 2014 Wiley Periodicals Inc.


Assuntos
Benchmarking , Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/métodos , Automação , Calibragem , Citometria de Fluxo
16.
J Res Natl Inst Stand Technol ; 119: 610-28, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-26601047

RESUMO

Measurements are presented of the absorbance, fluorescence emission, fluorescence quantum yield, and fluorescence lifetime of CdSe/ZnS nanocrystals, also known as quantum dots (QDs). The study included three groups of nanocrystals whose surfaces were either passivated with organic molecules, modified further with carboxyl groups, or conjugated with CD14 mouse anti-human antibodies. The surface modifications had observable effects on the optical properties of the nanocrystals. The oscillator strength (OS) of the band edge transition was about 1.0 for the nanocrystals emitting at 565 nm, 605 nm, and 655 nm. The OS could not be determined for QDs with emission at 700 nm and 800 nm. The fluorescence lifetimes varied from 26 ns for nanocrystals emitting near 600 nm to 150 ns for nanocrystals emitting near 800 nm. The quantum yield ranged between 0.4 and 0.9 for the nanocrystals in this study. A brightness index (BI) was used to evaluate the suitability of the nanocrystal labels for flow cytometer measurements. Most QD labels are at least as bright as fluorescein for applications in flow cytometer assays with 488 nm excitation. For optimal brightness the QDs should be excited with 405 nm light. We observed a strong dependence of the QD absorbance at 250 nm on the surface modification of the QD.

17.
PLoS One ; 8(9): e73701, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24019934

RESUMO

In this proof-of-concept study, we describe the use of the main red beet pigment betanin for the quantification of calcium dipicolinate in bacterial spores, including Bacillus anthracis. In the presence of europium(III) ions, betanin is converted to a water-soluble, non-luminescent orange 1∶1 complex with a stability constant of 1.4 × 10(5) L mol(-1). The addition of calcium dipicolinate, largely found in bacterial spores, changes the color of the aqueous solution of [Eu(Bn)(+)] from orange to magenta. The limit of detection (LOD) of calcium dipicolinate is around 2.0 × 10(-6) mol L(-1) and the LOD determined for both spores, B. cereus and B. anthracis, is (1.1 ± 0.3)× 10(6) spores mL(-1). This simple, green, fast and low cost colorimetric assay was selective for calcium dipicolinate when compared to several analogous compounds. The importance of this work relies on the potential use of betalains, raw natural pigments, as colorimetric sensors for biological applications.


Assuntos
Bacillus anthracis/fisiologia , Beta vulgaris/química , Colorimetria/instrumentação , Ácidos Picolínicos/análise , Raízes de Plantas/química , Esporos Bacterianos/química , Limite de Detecção
18.
Anal Chem ; 84(9): 3889-98, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22376085

RESUMO

The development of fluorescence applications in the life and material sciences has proceeded largely without sufficient concern for the measurement uncertainties related to the characterization of fluorescence instruments. In this first part of a two-part series on the state-of-the-art comparability of corrected emission spectra, four National Metrology Institutes active in high-precision steady-state fluorometry performed a first comparison of fluorescence measurement capabilities by evaluating physical transfer standard (PTS)-based and reference material (RM)-based calibration methods. To identify achievable comparability and sources of error in instrument calibration, the emission spectra of three test dyes in the wavelength region from 300 to 770 nm were corrected and compared using both calibration methods. The results, obtained for typical spectrofluorometric (0°/90° transmitting) and colorimetric (45°/0° front-face) measurement geometries, demonstrated a comparability of corrected emission spectra within a relative standard uncertainty of 4.2% for PTS- and 2.4% for RM-based spectral correction when measurements and calibrations were performed under identical conditions. Moreover, the emission spectra of RMs F001 to F005, certified by BAM, Federal Institute for Materials Research and Testing, were confirmed. These RMs were subsequently used for the assessment of the comparability of RM-based corrected emission spectra of field laboratories using common commercial spectrofluorometers and routine measurement conditions in part 2 of this series (subsequent paper in this issue).

19.
Anal Chem ; 84(9): 3899-907, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22376144

RESUMO

In the second part of this two-part series on the state-of-the-art comparability of corrected emission spectra, we have extended this assessment to the broader community of fluorescence spectroscopists by involving 12 field laboratories that were randomly selected on the basis of their fluorescence measuring equipment. These laboratories performed a reference material (RM)-based fluorometer calibration with commercially available spectral fluorescence standards following a standard operating procedure that involved routine measurement conditions and the data evaluation software LINKCORR developed and provided by the Federal Institute for Materials Research and Testing (BAM). This instrument-specific emission correction curve was subsequently used for the determination of the corrected emission spectra of three test dyes, X, QS, and Y, revealing an average accuracy of 6.8% for the corrected emission spectra. This compares well with the relative standard uncertainties of 4.2% for physical standard-based spectral corrections demonstrated in the first part of this study (previous paper in this issue) involving an international group of four expert laboratories. The excellent comparability of the measurements of the field laboratories also demonstrates the effectiveness of RM-based correction procedures.

20.
Am J Clin Oncol ; 34(6): 636-47, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22101389

RESUMO

PURPOSE: : External beam radiation therapy is a standard of care treatment for men who present with clinically localized (T1-T2) prostate cancer. The purpose of this review was to provide clarification on the appropriateness criteria and management considerations for the treatment of prostate cancer with external beam radiation therapy. METHODS: : A panel consisting of physicians with expertise on prostate cancer was assembled and provided with a number of clinical scenarios for consensus treatment and management guidelines. Prostate cancer patient vignettes were presented along with specific management recommendations based on an extensive review of the modern external beam radiotherapy literature. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed every 2 years by a multidisciplinary expert panel. The guideline development and review include an extensive analysis of current medical literature from peer reviewed journals and the application of a well established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances, where evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment. RESULTS: : Modern external beam radiation therapy series demonstrate favorable biochemical control rates for patients with localized prostate cancer. Morbidity profiles are also favorable and it is clear that this is enhanced by modern techniques like 3-dimensional conformal radiation therapy and intensity-modulated radiation therapy. An active area of investigation is evaluating the use of hypofractionated dosing. CONCLUSIONS: : Continued investigation to refine patient selection, external beam radiation technology application, and alternative dosing schedules should result in further improvements in biochemical outcome and decreased morbidity with external beam radiation treatment for localized prostate cancer.


Assuntos
Medicina Baseada em Evidências , Guias de Prática Clínica como Assunto , Neoplasias da Próstata/radioterapia , Radioterapia/métodos , Ensaios Clínicos como Assunto , Humanos , Masculino , Estadiamento de Neoplasias , Neoplasias da Próstata/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA