Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Circulation ; 146(5): 383-397, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35722876

RESUMO

BACKGROUND: Cerebral microbleeds (CMBs) have been observed in healthy elderly people undergoing systematic brain magnetic resonance imaging. The potential role of acute triggers on the appearance of CMBs remains unknown. We aimed to describe the incidence of new CMBs after transcatheter aortic valve replacement (TAVR) and to identify clinical and procedural factors associated with new CMBs including hemostatic measures and anticoagulation management. METHODS: We evaluated a prospective cohort of patients with symptomatic aortic stenosis referred for TAVR for CMBs (METHYSTROKE [Identification of Epigenetic Risk Factors for Ischemic Complication During the TAVR Procedure in the Elderly]). Standardized neurologic assessment, brain magnetic resonance imaging, and analysis of hemostatic measures including von Willebrand factor were performed before and after TAVR. Numbers and location of microbleeds on preprocedural magnetic resonance imaging and of new microbleeds on postprocedural magnetic resonance imaging were reported by 2 independent neuroradiologists blinded to clinical data. Measures associated with new microbleeds and postprocedural outcome including neurologic functional outcome at 6 months were also examined. RESULTS: A total of 84 patients (47% men, 80.9±5.7 years of age) were included. On preprocedural magnetic resonance imaging, 22 patients (26% [95% CI, 17%-37%]) had at least 1 microbleed. After TAVR, new microbleeds were observed in 19 (23% [95% CI, 14%-33%]) patients. The occurrence of new microbleeds was independent of the presence of microbleeds at baseline and of diffusion-weighted imaging hypersignals. In univariable analysis, a previous history of bleeding (P=0.01), a higher total dose of heparin (P=0.02), a prolonged procedure (P=0.03), absence of protamine reversion (P=0.04), higher final activated partial thromboplastin time (P=0.05), lower final von Willebrand factor high-molecular-weight:multimer ratio (P=0.007), and lower final closure time with adenosine-diphosphate (P=0.02) were associated with the occurrence of new postprocedural microbleeds. In multivariable analysis, a prolonged procedure (odds ratio, 1.22 [95% CI, 1.03-1.73] for every 5 minutes of fluoroscopy time; P=0.02) and postprocedural acquired von Willebrand factor defect (odds ratio, 1.42 [95% CI, 1.08-1.89] for every lower 0.1 unit of high-molecular-weight:multimer ratio; P=0.004) were independently associated with the occurrence of new postprocedural microbleeds. New CMBs were not associated with changes in neurologic functional outcome or quality of life at 6 months. CONCLUSIONS: One out of 4 patients undergoing TAVR has CMBs before the procedure and 1 out of 4 patients develops new CMBs. Procedural or antithrombotic management and persistence of acquired von Willebrand factor defect were associated with the occurrence of new CMBs. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02972008.


Assuntos
Hemorragia Cerebral , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/epidemiologia , Hemorragia Cerebral/etiologia , Feminino , Fluoroscopia , Hemostáticos , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Qualidade de Vida , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Fator de von Willebrand
2.
EuroIntervention ; 17(8): e680-e687, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34105511

RESUMO

BACKGROUND: Balloon aortic valvuloplasty (BAV) has been proposed as a therapeutic option in patients suffering from severe aortic stenosis (SAS) who need urgent non-cardiac surgery (NCS). Whether this strategy is better than medical therapy in this very specific population is unknown. AIMS: We aimed to evaluate the clinical benefit of an invasive strategy (IS) with preoperative BAV in patients with SAS requiring urgent NCS. METHODS: From 2011 to 2019, a registry conducted in two centres included 133 patients with SAS undergoing urgent NCS, of whom 93 underwent preoperative BAV (IS) and 40 a conservative strategy (CS) without BAV. All analyses were adjusted for confounding using inverse probability of treatment weighting (IPTW) (10 clinical and anatomical variables). RESULTS: The primary outcome was MACE at one-month follow-up after NCS including mortality, heart failure, and other cardiovascular outcomes. In patients managed conservatively, occurrence of MACE was 20.0% (n=8) and death was 10.0% (n=4) at 1 month. In patients undergoing BAV, the occurrence of MACE was 20.4% (n=19) and death was 5.4% (n=5) at 1 month. Among patients undergoing conservative management, all events were observed after NCS while, in patients undergoing BAV, 12.9% (n=12) had events between BAV and NCS including 3 deaths, and 7.5% (n=7) had events after NCS including 2 deaths. In IPTW propensity analyses, the incidence of the primary outcome (20.4% vs 20.0%; OR 0.93, 95% CI: 0.38-2.29) and three-month survival (89.2% vs 90.0%; IPTW-adjusted HR 0.90, 95% CI: 0.31-2.60) were similar in both groups. CONCLUSIONS: Patients with SAS managed conservatively before urgent NCS are at high risk of events. A systematic invasive strategy using BAV does not provide a significant improvement in clinical outcome.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Lancet Reg Health Eur ; 2: 100030, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34173627

RESUMO

BACKGROUND: A reduction of admission for MI has been reported in most countries affected by COVID-19. No clear explanation has been provided. METHODS: To report the incidence of myocardial infarction (MI) admission during COVID-19 pandemic and in particular during national lockdown in two unequally affected French provinces (10-million inhabitants) with a different media strategy, and to describe the magnitude of MI incidence changes relative to the incidence of COVID-19-related deaths. A longitudinal study to collect all MIs from January 1 until May 17, 2020 (study period) and from the identical time period in 2019 (control period) was conducted in all centers with PCI-facilities in northern "Hauts-de-France" province and western "Pays-de-la-Loire" Province. The incidence of COVID-19 fatalities was also collected. FINDINGS: In "Hauts-de-France", during lockdown (March 18-May 10), 1500 COVID-19-related deaths were observed. A 23% decrease in MI-IR (IRR=0.77;95%CI:0.71-0.84, p<0.001) was observed for a loss of 272 MIs (95%CI:-363,-181), representing 18% of COVID-19-related deaths. In "Pays-de-la-Loire", 382 COVID-19-related deaths were observed. A 19% decrease in MI-IR (IRR=0.81; 95%CI=0.73-0.90, p<0.001) was observed for a loss of 138 MIs (95%CI:-210,-66), representing 36% of COVID-19-related deaths. While in "Hauts-de-France" the MI decline started before lockdown and recovered 3 weeks before its end, in "Pays-de-la-Loire", it started after lockdown and recovered only by its end. In-hospital mortality of MI patients was increased during lockdown in both provinces (5.0% vs 3.4%, p=0.02). INTERPRETATION: It highlights one of the potential collateral damages of COVID-19 outbreak on cardiovascular health with a dramatic reduction of MI incidence. It advocates for a careful and weighted communication strategy in pandemic crises. FUNDING: The study was conducted without external funding.

4.
Arch Cardiovasc Dis ; 114(8-9): 537-549, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33895105

RESUMO

BACKGROUND: Transfemoral percutaneous transcatheter aortic valve implantation (TF-TAVI) is a safe, reproducible and established procedure, mainly performed under local anaesthesia, which is mostly administered and monitored by a dedicated anaesthesia team (regular approach). Our centre has developed a standardized pathway of care, and eligible patients are selected for a minimalist TF-TAVI, entirely managed by operators without the presence of the anaesthesia team in the operating room, like most interventional coronary procedures ("percutaneous coronary intervention-like" approach [PCI approach]). AIM: To compare the safety and efficacy of TF-TAVI performed with the PCI approach versus the regular approach. METHODS: The analysis population comprised all patients who underwent TF-TAVI with the PCI or regular approach in our institution from November 2016 to July 2019. The two co-primary endpoints were early safety composite and early efficacy composite at 30days as defined by the Valve Academic Research Consortium-2. The PCI (n=137) and Regular (n=221) approaches were compared using the propensity score based method of inverse probability of treatment weighting. RESULTS: No differences were observed after comparison of TAVI performed with the PCI or regular approach regarding the composite safety endpoint (7.3% vs. 11.3%; odds ratio 0.63, 95% confidence interval 0.37 to 1.07; P=0.086) or the composite efficacy endpoint (4.4% vs. 6.3%; odds ratio 0.78, 95% confidence interval 0.41 to 1.49; P=0.45). CONCLUSIONS: This study suggests that the efficacy and safety of TF-TAVI entirely managed by a PCI approach for selected patients are not different to those when TF-TAVI is performed with the attendance of a full anaesthesia care team. The PCI approach appears to be a safe and efficient clinical pathway, providing an appropriate and rational utilization of anaesthesiology resources, and could be used for the majority of TF-TAVI procedures.


Assuntos
Estenose da Valva Aórtica , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Fluoroscopia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Circulation ; 143(10): 1043-1061, 2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33683945

RESUMO

After 15 years of successive randomized, controlled trials, indications for transcatheter aortic valve replacement (TAVR) are rapidly expanding. In the coming years, this procedure could become the first line treatment for patients with a symptomatic severe aortic stenosis and a tricuspid aortic valve anatomy. However, randomized, controlled trials have excluded bicuspid aortic valve (BAV), which is the most frequent congenital heart disease occurring in 1% to 2% of the total population and representing at least 25% of patients 80 years of age or older referred for aortic valve replacement. The use of a less invasive transcatheter therapy in this elderly population became rapidly attractive, and approximately 10% of patients currently undergoing TAVR have a BAV. The U.S. Food and Drug Administration and the "European Conformity" have approved TAVR for low-risk patients regardless of the aortic valve anatomy whereas international guidelines recommend surgical replacement in BAV populations. Given this progressive expansion of TAVR toward younger and lower-risk patients, heart teams are encountering BAV patients more frequently, while the ability of this therapy to treat such a challenging anatomy remains uncertain. This review will address the singularity of BAV anatomy and associated technical challenges for the TAVR procedure. We will examine and summarize available clinical evidence and highlight critical knowledge gaps regarding TAVR utilization in BAV patients. We will provide a comprehensive overview of the role of computed tomography scans in the diagnosis, and classification of BAV and TAVR procedure planning. Overall, we will offer an integrated framework for understanding the current role of TAVR in the treatment of bicuspid aortic stenosis and for guiding physicians in clinical decision-making.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino
6.
EuroIntervention ; 17(1): 23-31, 2021 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-32624457

RESUMO

The proposed 2020 Core Curriculum for Percutaneous Cardiovascular Interventions aims to provide an updated European consensus that defines the level of experience and knowledge in the field of percutaneous cardiovascular intervention (PCI). It promotes homogenous education and training programmes among countries, and is the cornerstone of the new EAPCI certification, designed to support the recognition of competencies at the European level and the free movement of certified specialists in the European Community. It is based on a thorough review of the ESC guidelines and of the EAPCI textbook on percutaneous interventional cardiovascular medicine. The structure of the current core curriculum evolved from previous EAPCI core curricula and from the "2013 core curriculum of the general cardiologist" to follow the current ESC recommendations for core curricula. In most subject areas, there was a wide - if not unanimous - consensus among the task force members on the training required for the interventional cardiologist of the future. The document recommends that acquisition of competence in interventional cardiology requires at least two years of postgraduate training, in addition to four years devoted to cardiology. The first part of the curriculum covers general aspects of training and is followed by a comprehensive description of the specific components in 54 chapters. Each of the chapters includes statements of the objectives, and is further subdivided into the required knowledge, skills, behaviours, and attitudes.


Assuntos
Cardiologia , Intervenção Coronária Percutânea , Cardiologia/educação , Consenso , Currículo , Europa (Continente) , Humanos
8.
J Am Soc Echocardiogr ; 33(12): 1454-1464, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32919856

RESUMO

BACKGROUND: Impaired left ventricular (LV) speckle-tracking-derived global longitudinal strain (GLS) magnitude (GLS worse than 14.7%) has been associated with poor outcome in patients with severe aortic stenosis (AS) and preserved LV ejection fraction (EF). OBJECTIVES: To test the hypothesis that GLS magnitude ≤ 15% obtained with vendor-independent speckle-tracking strain software may be able to identify patients with severe AS who are at higher risk of death, despite preserved LVEF and no or mild symptoms. METHODS: GLS was retrospectively obtained in 332 patients with severe AS (aortic valve area indexed [AVAi] < 0.6 cm2/m2), no or mild symptoms, and LVEF ≥ 50%. Absolute values of GLS were collected. Survival analyses were carried out to study the impact of GLS magnitude on all-cause mortality. RESULTS: During a median follow-up period of 42 (37-46) months, 105 patients died. On multivariate analysis, and after adjustment of known clinical and/or echocardiographic predictors of outcome and aortic valve replacement as a time-dependent covariate, GLS magnitude ≤ 15% was independently associated with mortality during follow-up (all P < .01). Adding GLS magnitude ≤ 15% (adjusted hazard ratio = 1.99 [1.17-3.38], P = .011) to a multivariate model including clinical and echocardiographic variables of prognostic importance (aortic valve replacement, aortic valve area, LV stroke volume index < 30 mL/m2, and LVEF<60%) improved the predictive performance with improved global model fit, reclassification, and better discrimination. After propensity score matching (n = 196), increased risk of mortality persisted among patients with GLS magnitude ≤ 15% compared with those with GLS > 15% (hazard ratio = 2.10; 95% confidence interval, 1.20-3.68; P = .009). CONCLUSIONS: In this series of patients with severe AS, no or mild symptoms, and LVEF ≥ 50%, GLS obtained with vendor-independent speckle-tracking strain software was an effective tool to identify patients with a poor outcome. Detection of myocardial dysfunction by identifying GLS magnitude < 15% in patients with severe AS, no or mild symptoms, and LVEF ≥ 50%, can aid in risk assessment.


Assuntos
Estenose da Valva Aórtica , Disfunção Ventricular Esquerda , Estenose da Valva Aórtica/diagnóstico por imagem , Humanos , Prognóstico , Estudos Retrospectivos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda
10.
EuroIntervention ; 16(10): 842-849, 2020 11 20.
Artigo em Inglês | MEDLINE | ID: mdl-32310129

RESUMO

AIMS: No randomised study comparing the outcomes of transcarotid (TC) and transaxillary (TAx) TAVR has been conducted to date. The purpose of this study was to understand which approach should be the preferred alternative by comparing their outcomes using a propensity-matched comparison in a French multicentre registry. METHODS AND RESULTS: From 2010 to 2018, a French multicentre prospective registry included 502 patients, with 374 undergoing TC-TAVR and 128 TAx-TAVR for symptomatic aortic stenosis. Patients treated through TAx access were matched 1:2 with patients treated through the TC route by using a propensity score (20 clinical, anatomical and procedural variables) and by date of the procedure. The first outcome was mortality at one-month follow-up. The second outcome was one-month stroke/transient ischaemic attack (TIA). In propensity-matched analyses, the incidence of the primary outcome was similar in the TAx and TC groups (TAx 5.5% vs TC 4.5%, OR 1.23, 95% CI: 0.40-3.70). The secondary outcome was similar in TAx (3.2%) and TC (6.8%, OR 0.52, 95% CI: 0.14-1.84). Minor bleeding (2.7% vs 9.3%, OR 0.26, 95% CI: 0.07-0.92) and main access haematoma (3.6% vs 10.3%, OR 0.034, 95% CI: 0.09-0.92) were significantly more frequent with the TC access. One-month clinical efficacy and safety and one-year mortality did not differ according to the different routes. CONCLUSIONS: One-month mortality, one-month stroke/TIA and one-year mortality are similar with TAx-TAVR and TC-TAVR. However, TC-TAVR is accompanied by more minor bleeding and main access haematoma compared with the transaxillary route.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
J Am Heart Assoc ; 9(6): e014916, 2020 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-32172643

RESUMO

Background Ultrasound (US) guidance provides the unique opportunity to control the puncture zone of the artery during transfemoral transcatheter aortic valve replacement and may decrease major vascular complications (VC) and life-threatening or major bleeding complications. This study aimed to evaluate the clinical impact of US guidance using a propensity score-matched comparison. Methods and Results US guidance was implemented as the default approach for all transfemoral transcatheter aortic valve replacement cases in our institution in June 2013. We defined 3 groups of consecutive patients according to the method of puncture (fluoroscopic/US guidance) and the use of a transcatheter heart valve. Patients in the US-guided second-generation group (Sapien XT [Edwards Lifesciences, Irvine, CA], Corevalve [Medtronic, Dublin, Ireland]) were successfully 1:1 matched with patients in the fluoroscope-guided second-generation group (n=95) with propensity score matching. In a second analysis we described the consecutive patients of the US-guided third-generation group (Evolut-R [Medtronic], Sapien 3 [Edwards Lifesciences], n=308). All vascular and bleeding complications were reduced in the US-guided second-generation group compared with the fluoroscope-guided second-generation group: VC (16.8% versus 6.3%; P=0.023); life-threatening or major bleeding (22.1% versus 6%; P=0.004); and VC related to vascular access (12.6% versus 4.2%; P=0.052). In the US-guided third-generation group the rates of major VC and life-threatening or major bleeding were 3.2% (95% CI, 1.6% to 5.9%) and 3.6% (95% CI, 1.8% to 6.3%). In the overall population (n=546), life-threatening or major bleeding was associated with a 1.7-fold increased mortality risk (P=0.02). Conclusions We demonstrated that US guidance effectively reduced VC and bleeding complications for transfemoral transcatheter aortic valve replacement and should be considered the standard puncture method. Registration URL: http://www.clinicaltrials.gov. Unique identifier: NCT02628509.


Assuntos
Cateterismo Periférico , Artéria Femoral/diagnóstico por imagem , Hemorragia Pós-Operatória/prevenção & controle , Radiografia Intervencionista , Substituição da Valva Aórtica Transcateter , Ultrassonografia de Intervenção , Lesões do Sistema Vascular/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Feminino , Artéria Femoral/lesões , Fluoroscopia , Humanos , Masculino , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/mortalidade , Pontuação de Propensão , Punções , Radiografia Intervencionista/efeitos adversos , Radiografia Intervencionista/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Ultrassonografia de Intervenção/efeitos adversos , Ultrassonografia de Intervenção/mortalidade , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/mortalidade
12.
Circulation ; 141(4): 243-259, 2020 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-31736356

RESUMO

BACKGROUND: No randomized study powered to compare balloon expandable (BE) with self expanding (SE) transcatheter heart valves (THVs) on individual end points after transcatheter aortic valve replacement has been conducted to date. METHODS: From January 2013 to December 2015, the FRANCE-TAVI nationwide registry (Registry of Aortic Valve Bioprostheses Established by Catheter) included 12 141 patients undergoing BE-THV (Edwards, n=8038) or SE-THV (Medtronic, n=4103) for treatment of native aortic stenosis. Long term mortality status was available in all patients (median 20 months; interquartile range, 14 to 30). Patients treated with BE-THV (n=3910) were successfully matched 1:1 with 3910 patients treated with SE-THV by using propensity score (25 clinical, anatomical, and procedural variables) and by date of the procedure (within 3 months). The first coprimary outcome was ≥ moderate occurrence of paravalvular regurgitation or in-hospital mortality, or both. The second coprimary outcome was 2-year all-cause mortality. RESULTS: In propensity-matched analyses, the incidence of the first coprimary outcome was higher with SE-THV (19.8%) compared with BE-THV (11.9%; relative risk, 1.68 [95% CI, 1.46-1.91]; P<0.0001). Each component of the outcome was also higher in patients receiving SE-THV: ≥ moderate paravalvular regurgitation (15.5% versus 8.3%; relative risk, 1.90 [95% CI, 1.63-2.22]; P<0.0001) and in hospital mortality (5.6% versus 4.2%; relative risk, 1.34 [95% CI, 1.07-1.66]; P=0.01). During follow up, all cause mortality occurred in 899 patients treated with SE-THV (2-year mortality, 29.8%) and in 801 patients treated with BE-THV (2-year mortality, 26.6%; hazard ratio, 1.17 [95% CI, 1.06-1.29]; P=0.003). Similar results were found using inverse probability of treatment weighting using propensity score analysis. CONCLUSION: The present study suggests that use of SE-THV was associated with a higher risk of paravalvular regurgitation and higher in-hospital and 2-year mortality compared with use of BE-THV. These data strongly support the need for a randomized trial sufficiently powered to compare the latest generation of SE-THV and BE-THV. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov. Unique identifier: NCT01777828.


Assuntos
Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Intervalo Livre de Doença , Feminino , Seguimentos , França/epidemiologia , Humanos , Masculino , Taxa de Sobrevida
13.
J Am Coll Cardiol ; 73(9): 1078-1088, 2019 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-30846101

RESUMO

For decades, numerous observations have shown an intimate relationship between von Willebrand factor (VWF) multimer profile and heart valve diseases (HVD). The current knowledge of the unique biophysical properties of VWF helps us to understand the longstanding observations concerning the bleeding complications in patients with severe HVD. Not only does the analysis of the VWF multimer profile provide an excellent evaluation of HVD severity, it is also a strong predictor of clinical events. Also of importance, VWF responds within minutes to any significant change in hemodynamic valve status, making it an accurate marker of the quality of surgical and transcatheter therapeutic interventions. The authors provide in this review a practical, comprehensive, and evidence-based framework of the concept of VWF as a biomarker in HVD, advocating for its implementation into the clinical decision-making process besides usual clinical and imaging evaluation. They also delineate critical knowledge gaps and research priorities to definitely validate this concept.


Assuntos
Tomada de Decisão Clínica , Gerenciamento Clínico , Doenças das Valvas Cardíacas/sangue , Implante de Prótese de Valva Cardíaca/métodos , Fator de von Willebrand/metabolismo , Biomarcadores/sangue , Doenças das Valvas Cardíacas/cirurgia , Humanos , Índice de Gravidade de Doença
14.
Arch Cardiovasc Dis ; 111(11): 686-701, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29861294

RESUMO

BACKGROUND: Coronary artery disease (CAD) is the leading cause of systolic heart failure (HF). Cardiac magnetic resonance imaging (CMR) is a non-invasive technique that detects a myocardial infarction scar as subendocardial or transmural late gadolinium enhancement (st-LGE). AIM: We sought to evaluate whether a lack of st-LGE could rule out CAD in new-onset systolic HF of unknown aetiology. METHODS: We included 232 consecutive patients with new-onset HF and left ventricular ejection fraction ≤35% who underwent both coronary angiography and CMR to assess HF aetiology. CAD was defined as the presence of coronary artery stenosis≥50% on a coronary angiogram. We assessed sensitivity, specificity, and positive and negative likelihood ratios (PLR and NLR) of the presence of st-LGE to detect underlying CAD. A complementary meta-analysis of 11 studies (including ours) was also performed. RESULTS: In our study, 49 (21.1%) patients had CAD. The sensitivity and specificity of the presence of st-LGE to detect CAD were 69 and 92%, respectively. PLR and NLR were 8.47 and 0.33, respectively. In the meta-analysis, 1227 patients were included, and the prevalence of CAD ranged from 19.2 to 68.3%. Sensitivity, specificity, PLR and NLR were 87% (95% confidence interval [CI] 0.80-0.92), 93% (95% CI 0.89-0.96), 12.91 (95% CI 7.70-21.64) and 0.14 (95% CI 0.09-0.22), respectively. Altogether, 55 patients presented CAD with no st-LGE; inversely, 75 patients presented st-LGE with no CAD. CONCLUSION: With a CMR specificity of 93%, the absence of st-LGE rules out significant underlying CAD in patients with systolic HF of unknown aetiology in most cases.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Insuficiência Cardíaca Sistólica/etiologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Meios de Contraste/administração & dosagem , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/complicações , Estenose Coronária/fisiopatologia , Feminino , Insuficiência Cardíaca Sistólica/diagnóstico , Insuficiência Cardíaca Sistólica/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros , Reprodutibilidade dos Testes , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Função Ventricular Esquerda
16.
EuroIntervention ; 14(5): e519-e525, 2018 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-29741481

RESUMO

AIMS: The aim of the study was to assess the outcomes of balloon aortic valvuloplasty (BAV) as a rescue therapy in patients with cardiogenic shock (CS) related to severe aortic stenosis (AS). METHODS AND RESULTS: Forty-four consecutive patients, n=31 with hypotensive CS (HCS) and n=13 with non-hypotensive CS (NHCS) due to acutely decompensated severe AS, from two centres were treated with urgent BAV. The composite primary endpoint was mortality or recurrent CS at one-year follow-up. These patients (77.3±8.1 years old; 75% male) had a mean EuroSCORE II of 41.6±13.7%. One-month mortality was 47%. Twelve patients (27%) had either a staged TAVR (n=10) or surgical aortic valve replacement (SAVR) (n=2) with a median delay of 79 days after BAV: n=6 (19%) in the HCS subgroup and n=6 (46%) in the NHCS population (p=0.06). At one year, the rate of composite all-cause death or recurrent CS was 75% and significantly higher in the HCS subgroup (83% vs. 53%; p=0.03). Overall one-year mortality was 70% (n=31) with a trend for a better prognosis in NHCS patients (54% vs. 77%; p=0.09). Univariate predictive factors of the primary endpoint included preoperative dose of dobutamine >5 microg/kg/min (100% vs. 57%; p=0.001) and delayed BAV >48 hrs (90% vs. 59%; p=0.01). CONCLUSIONS: Despite the initial success of urgent BAV, morbidity and mortality of CS related to severe AS remain high and directly related to the time of the valvuloplasty. Performing BAV before or within 48 hours of starting inotropic agents appears to be key to survival.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Choque Cardiogênico/etiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
J Am Coll Cardiol ; 71(19): 2106-2118, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29747831

RESUMO

BACKGROUND: The main risk factor for bleeding in patients with continuous-flow mechanical circulatory support (CF-MCS) is the acquired von Willebrand factor (VWF) defect related to the high shear-stress forces developed by these devices. Although a higher bleeding rate has been reported in CF-MCS recipients who had reduced pulsatility, the relation between pulsatility and the VWF defect has never been studied. OBJECTIVES: The purpose of this study was to investigate the relation between pulsatility and VWF under CF-MCS. METHODS: We assessed the effect of 2 CF-MCS on VWF multimer degradation in a mock circulatory loop (model 1). Using these devices, we investigated in a dose-effect model (model 2) 3 levels of pulsatility in 3 groups of swine. In a cross-over model (model 3), we studied the effects of sequential changes of pulsatility on VWF. We reported the evolution of VWF multimerization in a patient undergoing serial CF-MCS and/or pulsatile-MCS. RESULTS: We demonstrated the proteolytic degradation of VWF multimers by high shear CF-MCS in a circulatory loop without pulsatility. We observed both in swine models and in a patient that the magnitude of the VWF degradation is modulated by the pulsatility level in the high shear-stress level condition, and that the restoration of pulsatility is a trigger for the endothelial release of VWF. CONCLUSIONS: We demonstrated that the VWF defect reflects the balance between degradation induced by the shear stress and the endothelial release of new VWF triggered by the pulsatility. This modulation of VWF levels could explain the relationship between pulsatility and bleeding observed in CF-MCS recipients. Preservation of pulsatility may be a new target to improve clinical outcomes of patients.


Assuntos
Pressão Arterial/fisiologia , Circulação Extracorpórea/tendências , Coração Auxiliar/tendências , Fluxo Pulsátil/fisiologia , Choque Cardiogênico/terapia , Fator de von Willebrand/metabolismo , Animais , Biomarcadores/sangue , Circulação Extracorpórea/efeitos adversos , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Choque Cardiogênico/sangue , Choque Cardiogênico/fisiopatologia , Estresse Mecânico , Suínos
18.
JACC Cardiovasc Interv ; 11(4): 354-365, 2018 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-29471949

RESUMO

OBJECTIVES: This study sought to prospectively assess the impact of routine invasive physiology at the time of angiography on reclassification of therapeutic management of multivessel disease (MVD) patients, and to assess how implementation of instantaneous wave-free ratio (iFR) alters the process. BACKGROUND: Routine invasive physiology in intermediate coronary lesions at the time of diagnostic angiography, primarily in patients with single-vessel disease and using fractional flow reserve (FFR), reclassifies coronary revascularization management in 26% to 44% of patients. The role of invasive physiology in patients with MVD is unclear. METHODS: In 18 centers, 484 patients undergoing diagnostic angiography disclosing MVD with lesions >40% by visual assessment were included. Investigators were asked to prospectively define their initial management strategy based on angiography and clinical information. Invasive physiology (FFR or iFR driven) was then performed and final strategy defined. Initial and final vessel, patient, procedural, and overall management were described. Reclassification was defined as the difference between initial and final strategy. RESULTS: The majority of patients were clinically stable (82.2%). Two- and 3-vessel disease was present in 73.3% and 26.7% of patients, respectively. Lesions investigated were "intermediate" with median percent stenosis, median FFR, and median iFR at 60% (interquartile range [IQR]: 50% to 70%), 0.84 (IQR: 0.78 to 0.90), and 0.92 (IQR: 0.85 to 0.96), respectively. Vessel management was reclassified by physiology in 30.0% (249 of 828) of vessels. Patient and overall management were reclassified in 26.9% (130 of 484) and 45.7% (211 of 484) of patients, respectively. Reclassification rates were high irrespective of initial management (optimal medical therapy, percutaneous coronary intervention, or coronary artery bypass grafting), and performance and results of pre-procedural noninvasive tests. Reclassification of overall management in particular increased with the number of vessels investigated (1 vessel: 37.3%; 2 vessels: 45.0%; 3 vessels: 66.7%; p = 0.002). Incorporating iFR in the decision process was associated with investigation of more vessels (p = 0.04) and higher reclassification (p = 0.0001). CONCLUSIONS: In patients with MVD and intermediate coronary lesions, invasive physiology at time of angiography reclassifies revascularization strategy in a large proportion of cases (26.9%) and investigation of more vessels is associated with higher reclassification rates.


Assuntos
Cateterismo Cardíaco , Tomada de Decisão Clínica , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Técnicas de Apoio para a Decisão , Reserva Fracionada de Fluxo Miocárdico , Revascularização Miocárdica/classificação , Idoso , Doença da Artéria Coronariana/classificação , Doença da Artéria Coronariana/terapia , Estenose Coronária/classificação , Estenose Coronária/terapia , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Prospectivos
19.
Am J Cardiol ; 120(11): 2025-2030, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28965713

RESUMO

Advanced chronic kidney disease (CKD) is an independent predictor of mortality in patients undergoing transcatheter aortic valve implantation (TAVI). We aimed to identify predictors of 1-year mortality in patients after TAVI stratified by the presence or absence of advanced CKD (defined as estimated glomerular filtration rate ≤30 ml/min/1.73 m2 or permanent renal replacement therapy). Patients (n = 1204) from 10 centers in Europe, Japan, and Israel were included: 464 with and 740 without advanced CKD. Advanced CKD was associated with a 2-fold increase in the adjusted risk of 1-year all-cause death (p <0.001), and a 1.9-fold increase in cardiovascular death (p = 0.016). Interaction-term analysis was used to identify and compare independent predictors of 1-year mortality in both groups. Impaired left ventricular ejection fraction and poor functional class were predictive of death in the advanced CKD group (odds ratio [OR] 2.27, p = 0.002 and OR 3.87, p = 0.003, respectively) but not in patients without advanced CKD (p for interaction = 0.035 and 0.039, respectively), whereas bleeding was a predictor of mortality in the nonadvanced CKD group (OR 3.2, p = 0.005) but not in advanced CKD (p for interaction = 0.006). Atrial fibrillation was associated with a 2.2-fold increase (p = 0.032) in the risk of cardiovascular death in the advanced CKD group but not in the absence of advanced CKD (p for interaction = 0.022). In conclusion, the coexistence of advanced CKD and either reduced left ventricular ejection fraction or poor functional class has an incremental effect on the risk of death after TAVI. In contrast, bleeding had a greater effect on risk of death in patients without advanced CKD.


Assuntos
Estenose da Valva Aórtica/cirurgia , Insuficiência Renal Crônica/complicações , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda/etiologia , Idoso de 80 Anos ou mais , Animais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Causas de Morte/tendências , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Taxa de Filtração Glomerular , Humanos , Masculino , Prognóstico , Insuficiência Renal Crônica/mortalidade , Insuficiência Renal Crônica/fisiopatologia , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Taxa de Sobrevida/tendências , Fatores de Tempo , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia
20.
EuroIntervention ; 13(10): 1149-1156, 2017 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-28760721

RESUMO

AIMS: Transcatheter aortic valve implantation for a failing surgical bioprosthesis (TAV-in-SAV) has become an alternative for patients at high risk for redo surgical aortic valve replacement (redo-SAVR). Comparisons between these approaches are non-existent. This study aimed to compare clinical and echocardiographic outcomes of patients undergoing TAV-in-SAV versus redo-SAVR after accounting for baseline differences by propensity score matching. METHODS AND RESULTS: Patients from seven centres in Europe and Canada who had undergone either TAV-in-SAV (n=79) or redo-SAVR (n=126) were identified. Significant independent predictors used for propensity scoring were age, NYHA functional class, number of prior cardiac surgeries, urgent procedure, pulmonary hypertension, and COPD grade. Using a calliper range of ±0.05, a total of 78 well-matched patient pairs were found. All-cause mortality was similar between groups at 30 days (6.4% redo-SAVR vs. 3.9% TAV-in-SAV; p=0.49) and one year (13.1% redo-SAVR vs. 12.3% TAV-in-SAV; p=0.80). Both groups also showed similar incidences of stroke (0% redo-SAVR vs. 1.3% TAV-in-SAV; p=1.0) and new pacemaker implantation (10.3% redo-SAVR vs. 10.3% TAV-in-SAV; p=1.0). The incidence of acute kidney injury requiring dialysis was numerically lower in the TAV-in-SAV group (11.5% redo-SAVR vs. 3.8% TAV-in-SAV; p=0.13). The TAV-in-SAV group had a significantly shorter median total hospital stay (12 days redo-SAVR vs. 9 days TAV-in-SAV; p=0.001). CONCLUSIONS: Patients with aortic bioprosthesis failure treated with either redo-SAVR or TAV-in-SAV have similar 30-day and one-year clinical outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adulto , Idoso , Idoso de 80 Anos ou mais , Bioprótese , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA