Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sci Transl Med ; 14(627): eabg3684, 2022 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-35020407

RESUMO

Positron emission tomography (PET) ligands play an important role in the development of therapeutics by serving as target engagement or pharmacodynamic biomarkers. Here, we describe the discovery and translation of the PET tracer [11C]MK-6884 from rhesus monkeys to patients with Alzheimer's disease (AD). [3H]MK-6884/[11C]MK-6884 binds with high binding affinity and good selectivity to an allosteric site on M4 muscarinic cholinergic receptors (M4Rs) in vitro and shows a regional distribution in the brain consistent with M4R localization in vivo. The tracer demonstrates target engagement of positive allosteric modulators of the M4R (M4 PAMs) through competitive binding interactions. [11C]MK-6884 binding is enhanced in vitro by the orthosteric M4R agonist carbachol and indirectly in vivo by the acetylcholinesterase inhibitor donepezil in rhesus monkeys and healthy volunteers, consistent with its pharmacology as a highly cooperative M4 PAM. PET imaging of [11C]MK-6884 in patients with AD identified substantial regional differences quantified as nondisplaceable binding potential (BPND) of [11C]MK-6884. These results suggest that [11C]MK-6884 is a useful target engagement biomarker for M4 PAMs but may also act as a sensitive probe of neuropathological changes in the brains of patients with AD.


Assuntos
Doença de Alzheimer , Acetilcolinesterase , Doença de Alzheimer/diagnóstico por imagem , Animais , Humanos , Macaca mulatta , Tomografia por Emissão de Pósitrons/métodos , Receptores Muscarínicos
2.
Mol Imaging Biol ; 22(1): 173-180, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31111397

RESUMO

PURPOSE: [18F]MK-6240 is a selective, high-affinity positron emission tomography tracer for imaging neurofibrillary tangles, a key pathological signature that correlates with cognitive decline in Alzheimer disease. This report provides safety information from preclinical toxicology studies and first-in-human whole-body biodistribution and dosimetry studies of [18F]MK-6240 for its potential application in human brain imaging studies. PROCEDURES: MK-6240 was administered intravenously (IV) in a 7-day rat toxicity study at × 50, × 100, and × 1000 dose margins relative to projected highest clinical dose of 0.333 µg/kg. The IV formulation of MK-6240 for clinical use and the formulation used in the 7-day rat toxicity study was tested for hemolysis potential in human and Wistar rat whole blood. Sequential whole-body positron emission tomography scans were performed in three healthy young subjects after IV bolus injection of 180 ± 0.3 MBq [18F]MK-6240 to characterize organ biodistribution and estimate whole-body radiation exposure (effective dose). RESULTS: MK-6240 administered IV in a 7-day rat toxicity study did not show any test article-related changes. The no-observed-adverse-effect level in rats was ≥ 333 µg/kg/day which provides a margin 1000-fold over an anticipated maximum clinical dose of 0.333 µg/kg. Additionally, the MK-6240 formulation was not hemolytic in human or Wistar rat blood. [18F]MK-6240 activity was widely distributed to the brain and the rest of the body, with organ absorbed doses largest for the gall bladder (202 µGy/MBq). The average (±SD) effective dose was 29.4 ± 0.6 µSv/MBq, which is in the typical range for F-18 radiolabeled ligands. CONCLUSIONS: Microdoses of [18F]MK-6240 are safe for clinical positron emission tomography imaging studies. Single IV administration of 185 MBq (5 mCi) [18F]MK-6240 is anticipated to result in a total human effective dose of 5.4 mSv and thus allows multiple positron emission tomography scans of the same subject per year.


Assuntos
Doença de Alzheimer/patologia , Radioisótopos de Flúor/farmacocinética , Isoquinolinas/farmacocinética , Emaranhados Neurofibrilares/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Radiometria/métodos , Imagem Corporal Total/métodos , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/metabolismo , Animais , Feminino , Voluntários Saudáveis , Humanos , Masculino , Emaranhados Neurofibrilares/metabolismo , Segurança do Paciente , Compostos Radiofarmacêuticos/farmacocinética , Ratos , Ratos Wistar , Distribuição Tecidual
3.
J Nucl Med ; 60(1): 107-114, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29880509

RESUMO

18F-MK-6240 (18F-labeled 6-(fluoro)-3-(1H-pyrrolo[2,3-c]pyridin-1-yl)isoquinolin-5-amine) is a highly selective, subnanomolar-affinity PET tracer for imaging neurofibrillary tangles (NFTs). Plasma kinetics, brain uptake, and preliminary quantitative analysis of 18F-MK-6240 in healthy elderly (HE) subjects, subjects with clinically probable Alzheimer disease (AD), and subjects with amnestic mild cognitive impairment were characterized in a study that is, to our knowledge, the first to be performed on humans. Methods: Dynamic PET scans of up to 150 min were performed on 4 cognitively normal HE subjects, 4 AD subjects, and 2 amnestic mild cognitive impairment subjects after a bolus injection of 152-169 MBq of 18F-MK-6240 to evaluate tracer kinetics and distribution in brain. Regional SUV ratio (SUVR) and distribution volume ratio were determined using the cerebellar cortex as a reference region. Total distribution volume was assessed by compartmental modeling using radiometabolite-corrected input function in a subgroup of 6 subjects. Results:18F-MK-6240 had rapid brain uptake with a peak SUV of 3-5, followed by a uniformly quick washout from all brain regions in HE subjects; slower clearance was observed in regions commonly associated with NFT deposition in AD subjects. In AD subjects, SUVR between 60 and 90 min after injection was high (approximately 2-4) in regions associated with NFT deposition, whereas in HE subjects, SUVR was approximately 1 across all brain regions, suggesting high tracer selectivity for binding NFTs in vivo. 18F-MK-6240 total distribution volume was approximately 2- to 3-fold higher in neocortical and medial temporal brain regions of AD subjects than in HE subjects and stabilized by 60 min in both groups. Distribution volume ratio estimated by the Logan reference tissue model or compartmental modeling correlated well (R2 > 0.9) to SUVR from 60 to 90 min for AD subjects. Conclusion:18F-MK-6240 exhibited favorable kinetics and high binding levels to brain regions with a plausible pattern for NFT deposition in AD subjects. In comparison, negligible tracer binding was observed in HE subjects. This pilot study suggests that simplified ratio methods such as SUVR can be used to quantify NFT binding. These results support further clinical development of 18F-MK-6240 for potential application in longitudinal studies.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/patologia , Encéfalo/patologia , Radioisótopos de Flúor , Isoquinolinas/metabolismo , Emaranhados Neurofibrilares/metabolismo , Tomografia por Emissão de Pósitrons , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Estudos de Casos e Controles , Feminino , Humanos , Isoquinolinas/sangue , Cinética , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Traçadores Radioativos
4.
J Nucl Med ; 56(10): 1520-6, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26229142

RESUMO

UNLABELLED: The quantification and variability of skeletal muscle glucose utilization (SMGU) in healthy subjects under basal (low insulin) conditions are poorly known. This information is essential early in clinical drug development to effectively interrogate novel pharmacologic interventions that modulate glucose uptake. The aim of this study was to determine test-retest characteristics and variability of SMGU within and between healthy subjects under basal conditions. Furthermore, different kinetic modeling strategies were evaluated to find the best-fitting model to assess SMGU studied by 18F-FDG. METHODS: Six healthy male volunteers underwent 2 dynamic 18F-FDG PET/CT scans with an interval of 24 h. Subjects were admitted to the clinical unit to minimize variability in daily activities and food intake and restrict physical activity. 18F-FDG PET/CT scans of gluteal and quadriceps muscle area were obtained with arterial input. Regions of interest were drawn over the muscle area to obtain time-activity curves and standardized uptake values (SUVs) between 60 and 90 min. Spectral analysis of the data and kinetic modeling was performed using 2-tissue-irreversible (2T3K), 2-tissue-reversible, and 3-tissue-sequential-irreversible (3T5KS) models. Reproducibility was assessed by intraclass correlation coefficients (ICCs) and within-subject coefficient of variation (WSCV). RESULTS: SUVs in gluteal and quadriceps areas were 0.56±0.09 and 0.64±0.07. ICCs (with 90% confidence intervals in parentheses) were 0.88 (0.64-0.96) and 0.96 (0.82-0.99), respectively, for gluteal and quadriceps muscles, and WSCV for gluteal and quadriceps muscles was 2.2% and 3.6%, respectively. The rate of glucose uptake into muscle was 0.0016±0.0004 mL/mL⋅min, with an ICC of 0.94 (0.93-0.95) and WSCV of 6.6% for the 3T5KS model, whereas an ICC of 0.98 (0.92-1.00) and WSCV of 2.8% was obtained for the 2T3K model. 3T5KS demonstrated the best fit to the measured experimental points. CONCLUSION: Minimal variability in skeletal muscle glucose uptake was observed under basal conditions in healthy subjects. SUV measurements and rate of glucose uptake values were reproducible, with an average WSCV of less than 5%. Compared with SUV, the 3-tissue model adds information about kinetics between blood, intra- and intercellular compartments, and phosphorylation that may highlight the exact mechanisms of metabolic changes after pharmacologic intervention.


Assuntos
Fluordesoxiglucose F18/farmacocinética , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes
5.
J Pharmacol Exp Ther ; 347(2): 478-86, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23975906

RESUMO

Calcitonin gene-related peptide (CGRP) is a potent neuropeptide whose agonist interaction with the CGRP receptor (CGRP-R) in the periphery promotes vasodilation, neurogenic inflammation and trigeminovascular sensory activation. This process is implicated in the cause of migraine headaches, and CGRP-R antagonists in clinical development have proven effective in treating migraine-related pain in humans. CGRP-R is expressed on blood vessel smooth muscle and sensory trigeminal neurons and fibers in the periphery as well as in the central nervous system. However, it is not clear what role the inhibition of central CGRP-R plays in migraine pain relief. To this end, the CGRP-R positron emission tomography (PET) tracer [(11)C]MK-4232 (2-[(8R)-8-(3,5-difluorophenyl)-6,8-[6-(11)C]dimethyl-10-oxo-6,9-diazaspiro[4.5]decan-9-yl]-N-[(2R)-2'-oxospiro[1,3-dihydroindene-2,3'-1H-pyrrolo[2,3-b]pyridine]-5-yl]acetamide) was discovered and developed for use in clinical PET studies. In rhesus monkeys and humans, [(11)C]MK-4232 displayed rapid brain uptake and a regional brain distribution consistent with the known distribution of CGRP-R. Monkey PET studies with [(11)C]MK-4232 after intravenous dosing with CGRP-R antagonists validated the ability of [(11)C]MK-4232 to detect changes in CGRP-R occupancy in proportion to drug plasma concentration. Application of [(11)C]MK-4232 in human PET studies revealed that telcagepant achieved only low receptor occupancy at an efficacious dose (140 mg PO). Therefore, it is unlikely that antagonism of central CGRP-R is required for migraine efficacy. However, it is not known whether high central CGRP-R antagonism may provide additional therapeutic benefit.


Assuntos
Acetanilidas/farmacocinética , Analgésicos/farmacocinética , Azepinas/farmacocinética , Encéfalo/metabolismo , Antagonistas do Receptor do Peptídeo Relacionado ao Gene de Calcitonina , Imidazóis/farmacocinética , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacocinética , Compostos de Espiro/farmacocinética , Acetanilidas/química , Adulto , Analgésicos/uso terapêutico , Animais , Azepinas/uso terapêutico , Encéfalo/diagnóstico por imagem , Radioisótopos de Carbono , Feminino , Humanos , Imidazóis/uso terapêutico , Macaca mulatta , Masculino , Pessoa de Meia-Idade , Transtornos de Enxaqueca/tratamento farmacológico , Transtornos de Enxaqueca/metabolismo , Estrutura Molecular , Ligação Proteica , Compostos Radiofarmacêuticos/química , Especificidade da Espécie , Compostos de Espiro/química , Distribuição Tecidual , Adulto Jovem
6.
J Am Chem Soc ; 124(6): 928-33, 2002 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-11829600

RESUMO

A huge variety of chemically modified oligonucleotide derivatives has been synthesized for possible antisense applications. One such derivative, hexitol nucleic acid (HNA), is a DNA analogue containing the standard nucleoside bases, but with a phosphorylated 1',5'-anhydrohexitol backbone. Hexitol nucleic acids are some of the strongest hybridizing antisense compounds presently known, but HNA duplexes are even more stable. We present here the first high-resolution structure of a double helical nucleic acid with all sugars being hexitols. Although designed to have a restricted conformational flexibility, the hexitol oligomer h(GTGTACAC) is able to crystallize in two different double helical conformations. Both structures display a high x-displacement, normal Watson-Crick base pairing, similar base stacking patterns, and a very deep major groove together with a minor groove with increased hydrophobicity. One of the conformations displays a major groove which is wide enough to accommodate a second HNA double helix resulting in the formation of a double helix of HNA double helices. Both structures show most similarities with the A-type helical structure, the anhydrohexitol chair conformation thereby acting as a good mimic for the furanose C3'-endo conformation observed in RNA. As compared to the quasi-linear structure of homo-DNA, the axial position of the base in HNA allows efficient base stacking and hence double helix formation.


Assuntos
Hexosefosfatos/química , DNA/química , Modelos Moleculares , Conformação de Ácido Nucleico , Ácidos Nucleicos/química , RNA/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA